1.
Cancers (Basel) ; 15(9)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37174128

RESUMO

Intraoperative differentiation of tumorous from non-tumorous tissue can help in the assessment of resection margins in breast cancer and its response to therapy and, potentially, reduce the incidence of tumor recurrence. In this study, the calculation of the attenuation coefficient and its color-coded 2D distribution was performed for different breast cancer subtypes using spectral-domain CP OCT. A total of 68 freshly excised human breast specimens containing tumorous and surrounding non-tumorous tissues after BCS was studied. Immediately after obtaining structural 3D CP OCT images, en face color-coded attenuation coefficient maps were built in co-(Att(co)) and cross-(Att(cross)) polarization channels using a depth-resolved approach to calculating the values in each A-scan. We determined spatially localized signal attenuation in both channels and reported ranges of attenuation coefficients to five selected breast tissue regions (adipose tissue, non-tumorous fibrous connective tissue, hyalinized tumor stroma, low-density tumor cells in the fibrotic tumor stroma and high-density clusters of tumor cells). The Att(cross) coefficient exhibited a stronger gain contrast of studied tissues compared to the Att(co) coefficient (i.e., conventional attenuation coefficient) and, therefore, allowed improved differentiation of all breast tissue types. It has been shown that color-coded attenuation coefficient maps may be used to detect inter- and intra-tumor heterogeneity of various breast cancer subtypes as well as to assess the effectiveness of therapy. For the first time, the optimal threshold values of the attenuation coefficients to differentiate tumorous from non-tumorous breast tissues were determined. Diagnostic testing values for Att(cross) coefficient were higher for differentiation of tumor cell areas and tumor stroma from non-tumorous fibrous connective tissue: diagnostic accuracy was 91-99%, sensitivity-96-98%, and specificity-87-99%. Att(co) coefficient is more suitable for the differentiation of tumor cell areas from adipose tissue: diagnostic accuracy was 83%, sensitivity-84%, and specificity-84%. Therefore, the present study provides a new diagnostic approach to the differentiation of breast cancer tissue types based on the assessment of the attenuation coefficient from real-time CP OCT data and has the potential to be used for further rapid and accurate intraoperative assessment of the resection margins during BCS.

2.
Front Oncol ; 13: 1133074, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36937429

RESUMO

Introduction: To improve the quality of brain tumor resections, it is important to differentiate zones with myelinated fibers destruction from tumor tissue and normal white matter. Optical coherence tomography (OCT) is a promising tool for brain tissue visualization and in the present study, we demonstrate the ability of cross-polarization (CP) OCT to detect damaged white matter and differentiate it from normal and tumor tissues. Materials and methods: The study was performed on 215 samples of brain tissue obtained from 57 patients with brain tumors. The analysis of the obtained OCT data included three stages: 1) visual analysis of structural OCT images; 2) quantitative assessment based on attenuation coefficients estimation in co- and cross-polarizations; 3) building of color-coded maps with subsequent visual analysis. The defining characteristics of structural CP OCT images and color-coded maps were determined for each studied tissue type, and then two classification tests were passed by 8 blinded respondents after a training. Results: Visual assessment of structural CP OCT images allows detecting white matter areas with damaged myelinated fibers and differentiate them from normal white matter and tumor tissue. Attenuation coefficients also allow distinguishing all studied brain tissue types, while it was found that damage to myelinated fibers leads to a statistically significant decrease in the values of attenuation coefficients compared to normal white matter. Nevertheless, the use of color-coded optical maps looks more promising as it combines the objectivity of optical coefficient and clarity of the visual assessment, which leads to the increase of the diagnostic accuracy of the method compared to visual analysis of structural OCT images. Conclusions: Alteration of myelinated fibers causes changes in the scattering properties of the white matter, which gets reflected in the nature of the received CP OCT signal. Visual assessment of structural CP OCT images and color-coded maps allows differentiating studied tissue types from each other, while usage of color-coded maps demonstrates higher diagnostic accuracy values in comparison with structural images (F-score = 0.85-0.86 and 0.81, respectively). Thus, the results of the study confirm the potential of using OCT as a neuronavigation tool during resections of brain tumors.

3.
Diagnostics (Basel) ; 11(4)2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33920827

RESUMO

INTRODUCTION: Despite the introduction of increasingly multifaceted diagnostic techniques and the general advances in emergency abdominal and vascular surgery, the outcome of treatment of patients with acute impaired intestinal circulation remains unsatisfactory. The non-invasive and high-resolution technique of optical coherence tomography (OCT) can be used intraoperatively to assess intestine viability and associated conditions that frequently emerge under conditions of impaired blood circulation. This study aims to demonstrate the effectiveness of multimodal (MM) OCT for intraoperative diagnostics of both the microstructure (cross-polarization OCT mode) and microcirculation (OCT angiography mode) of the small intestine wall in patients with acute mesenteric ischemia (AMI). METHODS AND PARTICIPANTS: A total of 18 patients were enrolled in the study. Nine of them suffered from AMI in segments II-III of the superior mesenteric artery (AMI group), whereby the ischemic segments of the intestine were examined. Nine others were operated on for adenocarcinoma of the colon (control group), thus allowing areas of their normal small intestine to be examined for comparison. Data on the microstructure and microcirculation in the walls of the small intestine were obtained intraoperatively from the side of the serous membrane using the MM OCT system (IAP RAS, Russia) before bowel resection. The MM OCT data were compared with the results of histological examination. RESULTS: The study finds that MM OCT visualized the damage to serosa, muscularis externa, and blood vessels localized in these layers in 100% of AMI cases. It also visualized the submucosa in 33.3% of AMI cases. The MM OCT images of non-ischemic (control group), viable ischemic, and necrotic small intestines (AMI group) differed significantly across stratification of the distinguishable layers, the severity of intermuscular fluid accumulations, and the type and density of the vasculature. CONCLUSION: The MM OCT diagnostic procedure optimally meets the requirements of emergency surgery. Data on the microstructure and microcirculation of the intestinal wall can be obtained simultaneously in real time without requiring contrast agent injections. The depth of visualization of the intestinal wall from the side of the serous membrane is sufficient to assess the volume of the affected tissues. However, the methodology for obtaining MM OCT data needs to be improved to minimize the motion artefacts generated in actual clinical conditions.

4.
Neurophotonics ; 6(3): 035003, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31312669

RESUMO

The methods used for digital processing of optical coherence tomography (OCT) and crosspolarization (CP) OCT images are focused on improving the contrast ratio of native structural OCT images. Such advances are particularly important for the intraoperative detection of glioma margins where the visual assessment of OCT images can be difficult and lead to errors. The aim of the study was to investigate the application of optical coefficients obtained from CP OCT data for the differentiation of glial tumorous tissue from a normal brain. Pseudocolor en-face OCT maps based on two optical coefficients (the commonly used rate of attenuation in the cochannel, and in addition, the interchannel attenuation difference) were constructed for normal rat brain coronal cross sections and for brains with a 101.8 rat glioblastoma model. It was shown that the use of optical coefficients significantly increased the available information from the OCT data in comparison with unprocessed images. As a result, this allowed contrasting of the white matter from the gray matter and tumorous tissue ex vivo, and for this purpose, the interchannel attenuation difference worked better. The interchannel attenuation difference values of white matter were at least seven and two times higher than corresponding values of the cortex and tumorous tissue, whereas the same parameter for cochannel attenuation coefficient values of white matter are about 4 and 1.4. However, quantitative analysis shows that both coefficients are suitable for the purpose of glioblastoma detection from normal brain tissue regardless of whether a necrotic component was present (in all compared groups p < 0.001 ).

5.
J Biomed Opt ; 24(6): 1-15, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31222989

RESUMO

We report a compact rigid instrument capable of delivering en-face optical coherence tomography (OCT) images alongside (epi)-fluorescence endomicroscopy (FEM) images by means of a robotic scanning device. Two working imaging channels are included: one for a one-dimensional scanning, forward-viewing OCT probe and another for a fiber bundle used for the FEM system. The robotic scanning system provides the second axis of scanning for the OCT channel while allowing the field of view (FoV) of the FEM channel to be increased by mosaicking. The OCT channel has resolutions of 25 / 60 µm (axial/lateral) and can provide en-face images with an FoV of 1.6 × 2.7 mm2. The FEM channel has a lateral resolution of better than 8 µm and can generate an FoV of 0.53 × 3.25 mm2 through mosaicking. The reproducibility of the scanning was determined using phantoms to be better than the lateral resolution of the OCT channel. Combined OCT and FEM imaging were validated with ex-vivo ovine and porcine tissues, with the instrument mounted on an arm to ensure constant contact of the probe with the tissue. The OCT imaging system alone was validated for in-vivo human dermal imaging with the handheld instrument. In both cases, the instrument was capable of resolving fine features such as the sweat glands in human dermal tissue and the alveoli in porcine lung tissue.


Assuntos
Derme/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Microscopia de Fluorescência/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Tomografia de Coerência Óptica/métodos , Animais , Humanos , Alvéolos Pulmonares/diagnóstico por imagem , Reprodutibilidade dos Testes , Glândulas Sudoríparas/diagnóstico por imagem , Suínos
6.
Front Oncol ; 9: 201, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31001471

RESUMO

This paper considers valuable visual assessment criteria for distinguishing between tumorous and non-tumorous tissues, intraoperatively, using cross-polarization OCT (CP OCT)-OCT with a functional extension, that enables detection of the polarization properties of the tissues in addition to their conventional light scattering. Materials and Methods: The study was performed on 176 ex vivo human specimens obtained from 30 glioma patients. To measure the degree to which the typical parameters of CP OCT images can be matched to the actual histology, 100 images of tumors and white matter were selected for visual analysis to be undertaken by three "single-blinded" investigators. An evaluation of the inter-rater reliability between the investigators was performed. Application of the identified visual CP OCT criteria for intraoperative use was performed during brain tumor resection in 17 patients. Results: The CP OCT image parameters that can typically be used for visual assessment were separated: (1) signal intensity; (2) homogeneity of intensity; (3) attenuation rate; (4) uniformity of attenuation. The degree of match between the CP OCT images and the histology of the specimens was significant for the parameters "signal intensity" in both polarizations, and "homogeneity of intensity" as well as the "uniformity of attenuation" in co-polarization. A test based on the identified criteria showed a diagnostic accuracy of 87-88%. Intraoperative in vivo CP OCT images of white matter and tumors have similar signals to ex vivo ones, whereas the cortex in vivo is characterized by indicative vertical striations arising from the "shadows" of the blood vessels; these are not seen in ex vivo images or in the case of tumor invasion. Conclusion: Visual assessment of CP OCT images enables tumorous and non-tumorous tissues to be distinguished. The most powerful aspect of CP OCT images that can be used as a criterion for differentiation between tumorous tissue and white matter is the signal intensity. In distinguishing white matter from tumors the diagnostic accuracy using the identified visual CP OCT criteria was 87-88%. As the CP OCT data is easily associated with intraoperative neurophysiological and neuronavigation findings this can provide valuable complementary information for the neurosurgeon tumor resection.

7.
Sci Rep ; 9(1): 2024, 2019 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-30765763

RESUMO

Optical coherence tomography (OCT) is a promising method for detecting cancer margins during tumor resection. This study focused on differentiating tumorous from nontumorous tissues in human brain tissues using cross-polarization OCT (CP OCT). The study was performed on fresh ex vivo human brain tissues from 30 patients with high- and low-grade gliomas. Different tissue types that neurosurgeons should clearly distinguish during surgery, such as the cortex, white matter, necrosis and tumorous tissue, were separately analyzed. Based on volumetric CP OCT data, tumorous and normal brain tissue were differentiated using two optical coefficients - attenuation and forward cross-scattering. Compared with white matter, tumorous tissue without necrotic areas had significantly lower optical attenuation and forward cross-scattering values. The presence of particular morphological patterns, such as necrosis and injured myelinated fibers, can lead to dramatic changes in coefficient values and create some difficulties in differentiating between tissues. Color-coded CP OCT maps based on optical coefficients provided a visual assessment of the tissue. This study demonstrated the high translational potential of CP OCT in differentiating tumorous tissue from white matter. The clinical use of CP OCT during surgery in patients with gliomas could increase the extent of tumor resection and improve overall and progression-free survival.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Encéfalo/diagnóstico por imagem , Tomografia de Coerência Óptica , Encéfalo/citologia , Encéfalo/patologia , Feminino , Glioma/diagnóstico por imagem , Glioma/patologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Curva ROC
8.
J Biophotonics ; 11(4): e201700072, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28853237

RESUMO

A novel machine-learning method to distinguish between tumor and normal tissue in optical coherence tomography (OCT) has been developed. Pre-clinical murine ear model implanted with mouse colon carcinoma CT-26 was used. Structural-image-based feature sets were defined for each pixel and machine learning classifiers were trained using "ground truth" OCT images manually segmented by comparison with histology. The accuracy of the OCT tumor segmentation method was then quantified by comparing with fluorescence imaging of tumors expressing genetically encoded fluorescent protein KillerRed that clearly delineates tumor borders. Because the resultant 3D tumor/normal structural maps are inherently co-registered with OCT derived maps of tissue microvasculature, the latter can be color coded as belonging to either tumor or normal tissue. Applications to radiomics-based multimodal OCT analysis are envisioned.


Assuntos
Algoritmos , Angiografia , Imageamento Tridimensional/métodos , Tomografia de Coerência Óptica , Animais , Linhagem Celular Tumoral , Camundongos , Camundongos Endogâmicos BALB C , Microvasos
9.
Biomed Opt Express ; 3(12): 3346-56, 2012 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-23243583

RESUMO

A dual instrument is assembled to investigate the usefulness of optical coherence tomography (OCT) imaging in an ear, nose and throat (ENT) department. Instrument 1 is dedicated to in vivo laryngeal investigation, based on an endoscope probe head assembled by compounding a miniature transversal flying spot scanning probe with a commercial fiber bundle endoscope. This dual probe head is used to implement a dual channel nasolaryngeal endoscopy-OCT system. The two probe heads are used to provide simultaneously OCT cross section images and en face fiber bundle endoscopic images. Instrument 2 is dedicated to either in vivo imaging of accessible surface skin and mucosal lesions of the scalp, face, neck and oral cavity or ex vivo imaging of the same excised tissues, based on a single OCT channel. This uses a better interface optics in a hand held probe. The two instruments share sequentially, the swept source at 1300 nm, the photo-detector unit and the imaging PC. An aiming red laser is permanently connected to the two instruments. This projects visible light collinearly with the 1300 nm beam and allows pixel correspondence between the en face endoscopy image and the cross section OCT image in Instrument 1, as well as surface guidance in Instrument 2 for the operator. The dual channel instrument was initially tested on phantom models and then on patients with suspect laryngeal lesions in a busy ENT practice. This feasibility study demonstrates the OCT potential of the dual imaging instrument as a useful tool in the testing and translation of OCT technology from the lab to the clinic. Instrument 1 is under investigation as a possible endoscopic screening tool for early laryngeal cancer. Larger size and better quality cross-section OCT images produced by Instrument 2 provide a reference base for comparison and continuing research on imaging freshly excised tissue, as well as in vivo interrogation of more superficial skin and mucosal lesions in the head and neck patient.

10.
J Biophotonics ; 4(7-8): 519-32, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21780300

RESUMO

The capabilities of cross-polarization optical coherence tomography (CP OCT) for early bladder-cancer detection are assessed in statistical study and compared with the traditional OCT. Unlike the traditional OCT that demonstrates images only in copolarization, CP OCT acquires images in cross-polarization and copolarization simultaneously. 116 patients with localized flat suspicious lesions in the bladder were enrolled, 360 CP OCT images were obtained and analyzed. CP OCT demonstrated sensitivity 93.7% (vs. 81.2%, <0.0001), specificity 84% (vs. 70.0%, <0.001) and accuracy 85.3% (vs. 71.5%, <0.001) in detecting flat malignant bladder lesions, which is significantly better than with the traditional OCT. Higher diagnostic efficacy of CP OCT in detecting early bladder cancer is associated with the ability to detect changes in epithelium and connective tissues.


Assuntos
Detecção Precoce de Câncer/métodos , Tomografia de Coerência Óptica/métodos , Neoplasias da Bexiga Urinária/diagnóstico , Reações Falso-Positivas , Humanos , Valor Preditivo dos Testes , Neoplasias da Bexiga Urinária/patologia
11.
J Biomed Opt ; 7(4): 633-42, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12421132

RESUMO

OBJECTIVE: To improve the precision of refractive surgery, a new approach for determination of the removed corneal thickness profile in situ with laser ablation by optical coherence tomography (OCT) is developed. STUDY DESIGN/MATERIALS AND METHODS: The traditional method for precision (less than 10 microm) measurements of intraocular distances is based on the use of the reflected component of probing radiation. This component is characterized by a small range of operating angles between a probing beam and a normal to the surface under study. To enhance this range of operating angles we suggest using a light component backscattered from a biological object. This will enable precision measurements over the entire surface of the cornea without any changes in the orientation between a probing beam and the eye, a necessary condition for in situ monitoring of laser refraction correction in the eye. We suggest a specially developed algorithm of OCT signal processing to measure the corneal thickness by the backscattered light component for a single longitudinal scan (A scan). The corneal thickness profile is obtained by a series of such A scans acquired by successively scanning a probing beam along the corneal surface. The thickness profile of removed layer is determined by changes in the corneal thickness profile in the process of ablation. When the cornea is ablated by a beam with a fixed transverse profile, we propose using integral characteristics of the ablated layer profile, for example, the maximum ablation depth, as criteria of changes in refractive power of the eye. The measurement precision by these characteristics is considerably higher than by a single A scan. Since the cornea is a poorly scattering medium, the Fourier filtering is employed to increase reliability and precision of the method. Model experiments on monitoring the ablation process in a lavsan film and ex vivo human cornea are described. Preliminary experiments on in vivo measurements of human corneal thickness are performed. RESULTS: In model experiments the precision of measurement of laser ablation depth by one A scan was 5-20 microm, depending on the signal-to-noise ratio (SNR), whereas the precision of measurement of laser ablation depth as the integral characteristic of the ablated layer profile was 0.3-5 microm. The experimental results showed that at small SNR Fourier filtering might considerably increase reliability and precision of measurements. When SNR is high, the measurement precision does not change. The precision of measurements of the corneal thickness in preliminary in vivo experiments was higher than in ex vivo experiments. This factor is very promising for application of the method suggested herein in refractive surgery.


Assuntos
Tecnologia de Fibra Óptica/métodos , Terapia a Laser , Tomografia/métodos , Tecnologia de Fibra Óptica/instrumentação , Tecnologia de Fibra Óptica/estatística & dados numéricos , Análise de Fourier , Humanos , Técnicas In Vitro , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/estatística & dados numéricos , Procedimentos Cirúrgicos Refrativos , Tomografia/instrumentação , Tomografia/estatística & dados numéricos
12.
J Urol ; 167(3): 1492-6, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11832776

RESUMO

PURPOSE: Optical coherence tomography is a new imaging modality capable of imaging luminal surface of biological tissue in the near infrared range with a spatial resolution close to the cellular level. We identified characteristic optical coherence tomography patterns for nonproliferative and proliferative inflammation, and malignant alterations of the bladder. MATERIALS AND METHODS: Optical coherence tomography was performed to image the bladder of 66 patients. The probe passed through the operating channel of a cystoscope and was pressed onto the mucosal site of interest. A mucosal biopsy of the image site was obtained. Optical coherence tomography was used to construct 680 images of the bladder and the images were compared with histology slides. RESULTS: Optical coherence tomography images of normal bladder showed 3 layers, namely the mucosa or transitional epithelium, submucosa and smooth muscle. In exudative processes there were poor light scattering areas in the connective tissue layer. Images of bladders with proliferative cystitis revealed nonuniform thickening of the epithelium or hyperplasia. Squamous metaplasia appeared as thicker and less transparent epithelium with a jagged boundary. Images of transitional cell carcinoma were characterized by the complete loss of a regular layered structure of the bladder wall and the penetration depth of optical imaging was slight. CONCLUSIONS: This study provides the characteristic optical coherence tomography pattern of nonproliferative and proliferative inflammation, and the characteristic appearance of severe dysplasia and transitional cell carcinoma. This technique may be useful as a guide for biopsy and for assisting in establishing resection margins.


Assuntos
Cistite/diagnóstico , Tomografia/métodos , Neoplasias da Bexiga Urinária/diagnóstico , Bexiga Urinária/patologia , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células de Transição/diagnóstico , Doença Crônica , Estudos de Viabilidade , Humanos , Raios Infravermelhos , Óptica e Fotônica , Bexiga Urinária/anatomia & histologia