Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 30(Pt 4): 662-670, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37163304

RESUMO

Transmission measurements of the soft X-ray beamline to the Small Quantum Systems (SQS) scientific instrument at the SASE3 undulator of European XFEL are presented. Measurements are reported for a wide range of photon energies (650 eV to 2400 eV), using X-ray gas monitors as well as a bolometric radiometer. The results are in good agreement with simulations for the beam transport and show a transmission of up to 80% over the whole photon energy range. The contribution of second- and third-harmonic radiation of the soft X-ray undulator is determined at selected photon energies by performing transmission measurements using a gas absorber to provide variable attenuation of the incoming photon flux. A comparison of the results with semi-analytic calculations for the generation of free-electron laser pulses in the SASE3 undulator reveals an influence of apertures along the beam transport on the exact harmonic content to be accounted for at the experiment. The second-harmonic content is measured to be in the range of 0.1% to 0.3%, while the third-harmonic contributed a few percent to the SASE3 emission. For experiments at the SQS instrument, these numbers can be reduced through specific selections of the mirror reflection angles.


Assuntos
Lasers , Síncrotrons , Raios X , Radiografia , Fótons
2.
J Synchrotron Radiat ; 28(Pt 3): 769-777, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33949985

RESUMO

A scheme to generate wide-bandwidth radiation using a step-wise tapered undulator with a segmented structure is proposed. This magnetic field configuration allows to broaden the undulator harmonic spectrum by two orders of magnitude, providing 1 keV bandwidth with spectral flux density exceeding 1016 photons s-1 mm-2 (0.1% bandwidth)-1 at 5 keV on the sample. Such a magnetic setup is applicable to superconducting devices where magnetic tapering cannot be arranged mechanically. The resulting radiation with broadband spectrum and flat-top shape may be exploited at a multipurpose beamline for scanning over the spectrum at time scales of 10-100 ms. The radiation from a segmented undulator is described analytically and derivations with numerical simulations are verified. In addition, a start-to-end simulation of an optical beamline is performed and issues related to the longitudinally distributed radiation source and its image upon focusing on the sample are addressed.

3.
J Synchrotron Radiat ; 22(2): 288-316, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25723931

RESUMO

The maximum of the Wigner distribution (WD) of synchrotron radiation (SR) fields is considered as a possible definition of SR source brightness. Such a figure of merit was originally introduced in the SR community by Kim [(1986), Nucl. Instrum. Methods Phys. Res. A, 246, 71-76]. The brightness defined in this way is always positive and, in the geometrical optics limit, can be interpreted as the maximum density of photon flux in phase space. For undulator and bending magnet radiation from a single electron, the WD function can be explicitly calculated. In the case of an electron beam with a finite emittance the brightness is given by the maximum of the convolution of a single electron WD function and the probability distribution of the electrons in phase space. In the particular case when both electron beam size and electron beam divergence dominate over the diffraction size and the diffraction angle, one can use a geometrical optics approach. However, there are intermediate regimes when only the electron beam size or the electron beam divergence dominate. In these asymptotic cases the geometrical optics approach is still applicable, and the brightness definition used here yields back once more to the maximum photon flux density in phase space. In these intermediate regimes a significant numerical disagreement is found between exact calculations and the approximation for undulator brightness currently used in the literature. The WD formalism is extended to a satisfactory theory for the brightness of a bending magnet. It is found that in the intermediate regimes the usually accepted approximation for bending magnet brightness turns out to be inconsistent even parametrically.

4.
Phys Rev E Stat Nonlin Soft Matter Phys ; 65(6 Pt 2): 066504, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12188843

RESUMO

Coherent synchrotron radiation (CSR) is a well known phenomenon that originates from coherent superposition of electromagnetic waves by ultrarelativistic electrons. CSR longitudinal effects during the passage of a Gaussian beam from a straight to a circular path have often been studied in a regime in which they are energy independent. Nevertheless, the approximations used in such a regime may fail in several practical situations, as in the case of low-energy injectors or for small-wavelength structures within the bunch distribution in CSR-related instability problems. These situations demand a deeper investigation of longitudinal transient effects in the region where the approximations above are no longer valid: a strong gamma dependence is found, and described in this paper, in the rate of energy change induced by CSR during the transient of a Gaussian bunch between a straight and a circular path, which was studied with the help of the authors' previous work. Results show that the overall CSR longitudinal effects, in this case, are reduced. One of the outcomes of previous work by Saldin et al. was extended to this situation and very good agreement between the two studies was found.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA