Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Platelets ; 29(1): 21-26, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28643541

RESUMO

The 2013 ISTH-SSC guidelines for the standardization of light transmission aggregometry (LTA) were largely based on expert consensus, as studies directly comparing LTA methodologies were lacking. We experimentally tested the cogency of ISTH-SSC recommendations pertaining to use of anticoagulant, in particular whether: (1) buffered citrate (BC) is preferable to unbuffered citrate (C); (2) the two recommended concentrations of sodium citrate (109 and 129 mM) are equivalent in terms of platelet aggregation (PA). Blood from 16 healthy volunteers was collected into BC and C (109 and 129 mM). PA was measured by LTA in platelet-rich plasma (PRP) stimulated by adenosine diphosphate (ADP) (2 µM) immediately after PRP preparation and up to 4 hr after blood collection; pH and platelet counts in PRP were measured in parallel. pH in PRP increased with time up to about 8 for all anticoagulants, although it was lower in BC than in C at all times. In BC, PA was lower at 45 min, but equivalent at all other times. PA was higher and more stable in sodium citrate 109 mM than in 129 mM at all times. The extent of PA did not change for up to 2 hr after blood collection, and subsequently dramatically decreased. In contrast with ISTH-SSC recommendations, (1) BC does not show advantages compared to C; (2) 109 mM citrate is preferable to 129 mM, because it better supports PA; and (3) LTA studies should be completed within 2 hr of blood collection, instead of the recommended 4 hr.


Assuntos
Difosfato de Adenosina/farmacologia , Anticoagulantes/farmacologia , Plaquetas/efeitos dos fármacos , Plaquetas/fisiologia , Citratos/farmacologia , Concentração de Íons de Hidrogênio , Agregação Plaquetária/efeitos dos fármacos , Testes de Função Plaquetária , Adulto , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Testes de Função Plaquetária/métodos , Plasma Rico em Plaquetas/efeitos dos fármacos , Citrato de Sódio , Adulto Jovem
2.
Thromb Res ; 133(2): 254-6, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24331208

RESUMO

INTRODUCTION: The platelet function analyzer (PFA)-100 is used in clinical practice to screen patients with bleeding diathesis and suspected defects of primary hemostasis. A new cartridge, INNOVANCE PFA P2Y, has been specifically developed to monitor patients' response to drugs inhibiting the platelet P2Y12 receptor for ADP. In this study, we compared the ability of INNOVANCE PFA P2Y to detect congenital defects of the platelet P2Y12 receptor to that of standard cartridge formulations currently in clinical use. MATERIALS AND METHODS: We studied two patients with severe P2Y12 deficiency, one patient with heterozygous P2Y12 deficiency and one with dysfunctional P2Y12 receptor. Closure times were measured using 3 cartridges: collagen/ADP, collagen/epinephrine, and INNOVANCE PFA P2Y. The results obtained in the four patients with P2Y12 defects were compared to those obtained for 20 healthy controls. RESULTS: In 2 patients with severe P2Y12 deficiency, closure times of INNOVANCE PFA P2Y and collagen/ADP cartridges were >300 s, while those of collagen/epinephrine cartridge were variable (186s and >300 s). In the patient with dysfunctional P2Y12, closure time of INNOVANCE PFA P2Y was >300 s, while closure times of collagen/ADP and collagen/epinephrine were normal. Closure times of all cartridges were normal in the patient with heterozygous P2Y12 deficiency. CONCLUSION: Our study provides the first evidence that INNOVANCE PFA P2Y cartridge is sensitive to congenital severe and moderate defects of the platelet P2Y12 receptors.


Assuntos
Plaquetas/metabolismo , Testes de Função Plaquetária/instrumentação , Receptores Purinérgicos P2Y12/metabolismo , Difosfato de Adenosina/metabolismo , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA