Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Cancers (Basel) ; 13(24)2021 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-34944816

RESUMO

Facial muscle corticobulbar motor evoked potentials (FMcoMEPs) are used to monitor facial nerve integrity during vestibular schwannoma resections to increase maximal safe tumor resection. Established warning criteria, based on ipsilateral amplitude reduction, have the limitation that the rate of false positive alarms is high, in part because FMcoMEP changes occur on both sides, e.g., due to brain shift or pneumocephalus. We retrospectively compared the predictive value of ipsilateral-only warning criteria and actual intraoperative warnings with a novel candidate warning criterion, based on "ipsilateral versus contralateral difference in relative stimulation threshold increase, from baseline to end of resection" (BilatMT ≥ 20%), combined with an optimistic approach in which a warning would be triggered only if all facial muscles on the affected side deteriorated. We included 60 patients who underwent resection of vestibular schwannoma. The outcome variable was postoperative facial muscle function. Retrospectively applying BilatMT, with the optimistic approach, was found to have a significantly better false positive rate, which was much lower (9% at day 90) than the traditionally used ipsilateral warning criteria (>20%) and was also lower than actual intraoperative warnings. This is the first report combining the threshold method with an optimistic approach in a bilateral multi-facial muscle setup. This method could substantially reduce the rate of false positive alarms in FMcoMEP monitoring.

2.
Clin Neuroradiol ; 31(4): 1149-1157, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33313974

RESUMO

PURPOSE: Intracranial lateral dural arteriovenous fistula (LDAVF) represents a specific subtype of cerebrovascular fistulae, harboring a potentially life-threatening risk of brain hemorrhage. Fluoroscopically guided endovascular embolization is the therapeutic gold standard. We provide detailed dosimetry data to suggest novel diagnostic reference levels (DRL). METHODS: Retrospective single-center study of LDAVFs treated between January 2014 and December 2019. Regarding dosimetry, the dose area product (DAP) and fluoroscopy time were analyzed for the following variables: Cognard scale grade, endovascular technique, angiographic outcome, and digital subtraction angiography (DSA) protocol. RESULTS: A total of 70 patients (19 female, median age 65 years) were included. Total median values for DAP and fluoroscopy time were 325 Gy cm2 (25%/75% percentile: 245/414 Gy cm2) and 110 min (68/142min), respectively. Neither median DAP nor fluoroscopy time were significantly different when comparing low-grade with high-grade LDAVF (Cognard I + IIa versus IIb-V; p > 0.05, each). Transvenous coil embolization yielded the lowest dosimetry values, with significantly lower median values when compared to a combined transarterial/transvenous technique (DAP 290 Gy cm2 versus 388 Gy cm2, p = 0.031; fluoroscopy time 85 min versus 170 min, p = 0.016). A significant positive correlation was found between number of arterial feeders treated by liquid embolization and both DAP (rs = 0.367; p = 0.010) and fluoroscopy time (rs = 0.295; p = 0.040). Complete LDAVF occlusion was associated with transvenous coiling (p = 0.001). A low-dose DSA protocol yielded a 20% reduction of DAP (p = 0.021). CONCLUSION: This LDAVF study suggests several local DRLs which varied substantially dependent on the endovascular technique and DSA protocol.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Embolização Terapêutica , Procedimentos Endovasculares , Idoso , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/terapia , Feminino , Fluoroscopia , Humanos , Doses de Radiação , Estudos Retrospectivos
3.
Eur Radiol ; 29(6): 2859-2867, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30635759

RESUMO

OBJECTIVES: Intraoperative CT (iCT) angiography of the brain with stereotactic frames is an integral part of navigated neurosurgery. Validated data regarding radiation dose and image quality in these special examinations are not available. We therefore investigated two iCT protocols in this IRB-approved study. METHODS: Retrospective analysis of patients, who received a cerebral stereotactic iCT angiography on a 128 slice CT scanner between February 2016 and December 2017. In group A, automated tube current modulation (ATCM; reference value 410 mAs) and automated tube voltage selection (reference value 120 kV) were enabled, and only examinations with a selected voltage of 120 kV were included. In group B, fixed parameters were applied (300 mAs, 120 kV). Radiation dose was measured by assessing the volumetric CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED). Signal-to-noise ratio (SNR) and image noise were assessed for objective image quality, visibility of arteries and grey-white differentiation for subjective image quality. RESULTS: Two hundred patients (n = 100 in each group) were included. In group A, median selected tube current was 643 mAs (group B, 300 mAs; p < 0.001). Median values of CTDIvol, DLP and ED were 91.54 mGy, 1561 mGy cm and 2.97 mSv in group A, and 43.15 mGy, 769 mGy cm and 1.46 mSv in group B (p < 0.001). Image quality did not significantly differ between groups (p > 0.05). CONCLUSIONS: ATCM yielded disproportionally high radiation dose due to substantial tube current increase at the frame level, while image quality did not improve. Thus, ATCM should preferentially be disabled. KEY POINTS: • Automated tube current modulation (ATCM) yields disproportionally high radiation dose in intraoperative CT angiography of the brain with stereotactic head frames. • ATCM does not improve overall image quality in these special examinations. • ATCM is not yet optimised for CT angiography of the brain with major extracorporeal foreign materials within the scan range.


Assuntos
Neoplasias Encefálicas/diagnóstico , Encéfalo/diagnóstico por imagem , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Imageamento Tridimensional , Procedimentos Neurocirúrgicos/métodos , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Encéfalo/efeitos da radiação , Neoplasias Encefálicas/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Adulto Jovem
4.
Acad Radiol ; 22(9): 1138-46, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26094116

RESUMO

RATIONALE AND OBJECTIVES: To investigate the diagnostic performance of a comprehensive computed tomography (CT) protocol for both cardiac and aortoiliac evaluation of patients considered for transcatheter aortic valve replacement (TAVR) using a single, low-volume contrast medium (CM) injection. MATERIALS AND METHODS: Forty-four TAVR candidates were retrospectively analyzed. All underwent retrospectively electrocardiogram-gated cardiac CT followed by high-pitch CT angiography of the aortoiliac vasculature using one of two single injection protocols of 320 mgI/mL iodine CM: group A (n = 22), iodine delivery rate-based (1.28 gI/s), 60-mL CM volume, 4.0 mL/s flow rate; group B (n = 22), clinical routine protocol, 100-mL CM volume, 4.0 mL/s flow rate. Mean arterial attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was assessed. RESULTS: Aortic root and iliofemoral dimensions could be analyzed in all cases. Patient characteristics showed no significant differences. Mean attenuation at the levels of the aortic root (285.8 ± 83.0 HU vs 327.5 ± 70.8 HU, P = .080) and the iliofemoral access route (256.8 ± 88.5 HU vs 307.5 ± 93.2 HU, P = .071), as well as SNR and CNR were nonsignificantly lower in group A compared to group B. Subjective image quality was equivalent. CONCLUSIONS: In multimorbid TAVR patients, the performance of a combined CT protocol using a single low-volume CM bolus is feasible with maintained image quality compared to a standard protocol.


Assuntos
Aortografia/métodos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Coração/diagnóstico por imagem , Artéria Ilíaca/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Planejamento de Assistência ao Paciente , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Ácidos Tri-Iodobenzoicos/administração & dosagem
5.
J Clin Endocrinol Metab ; 100(4): 1300-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25546155

RESUMO

CONTEXT: Successful tumor resection in endogenous Cushing's syndrome (CS) results in tertiary adrenal insufficiency requiring hydrocortisone replacement therapy. OBJECTIVE: The aim was to analyze the postsurgical duration of adrenal insufficiency of patients with Cushing's disease (CD), adrenal CS, and ectopic CS. DESIGN: We performed a retrospective analysis based on the case records of 230 patients with CS in our tertiary referral center treated from 1983-2014. The mean follow-up time was 8 years. PATIENTS: We included 91 patients of the three subtypes of CS undergoing curative intended surgery and documented followup after excluding cases with persistent disease, pituitary radiation, concurrent adrenostatic or somatostatin analog treatment, and malignant adrenal disease. RESULTS: The probability of recovering adrenal function within a 5 years followup differed significantly between subtypes (P = .001). It was 82% in ectopic CS, 58% in CD and 38% in adrenal CS. In the total cohort with restored adrenal function (n = 52) the median time to recovery differed between subtypes: 0.6 years (interquartile range [IQR], 0.03-1.1 y) in ectopic CS, 1.4 years (IQR, 0.9-3.4 y) in CD, and 2.5 years (IQR, 1.6-5.4 y) in adrenal CS (P = .002). In CD the Cox proportional-hazards model showed that the probability of recovery was associated with younger age (hazard ratio, 0.896; 95% confidence interval, 0.822-0.976; P = .012), independently of sex, body mass index, duration of symptoms, and basal ACTH and cortisol levels. There was no correlation with length and extend of hypercortisolism or postoperative glucocorticoid replacement doses. CONCLUSIONS: Time to recovery of adrenal function is dependent on the underlying etiology of CS.


Assuntos
Glândulas Suprarrenais/fisiologia , Síndrome de Cushing/etiologia , Síndrome de Cushing/reabilitação , Recuperação de Função Fisiológica , Adenoma Hipofisário Secretor de ACT/reabilitação , Adenoma Hipofisário Secretor de ACT/cirurgia , Adenoma/complicações , Adenoma/reabilitação , Adenoma/cirurgia , Insuficiência Adrenal/etiologia , Insuficiência Adrenal/reabilitação , Insuficiência Adrenal/cirurgia , Adulto , Síndrome de Cushing/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Tempo
6.
Eur Radiol ; 24(11): 2677-84, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25052076

RESUMO

OBJECTIVES: To evaluate the effect of automated tube voltage selection on radiation dose and image quality at cardiovascular CT angiography (CTA). METHODS: We retrospectively analysed paired studies in 72 patients (41 male, 60.5 ± 16.5 years), who had undergone CTA acquisitions of the heart or aorta both before and after the implementation of an automated x-ray tube voltage selection algorithm (ATVS). All other parameters were kept identical between the two acquisitions. Subjective image quality (IQ) was rated and objective IQ was measured by image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM). Image quality parameters and effective dose were compared between acquisitions. RESULTS: Overall subjective image quality improved with the percentage of cases scored as adequate or higher increasing from 79 % to 92 % after implementation of ATVS (P = 0.03). SNR (14.1 ± 5.9, 15.7 ± 6.1, P = 0.009), CNR (11.6 ± 5.3, 13.2 ± 5.6, P = 0.011), and FOM (19.9 ± 23.3, 43.8 ± 51.1, P < 0.001) were significantly higher after implementation of ATVS. Mean image noise (24.1 ± 8.4 HU, 22.7 ± 7.1 HU, P = 0.048) and mean effective dose (10.6 ± 5.9 mSv, 8.8 ± 5.0 mSv, P = 0.003) were significantly lower after implementation of ATVS. CONCLUSIONS: Automated tube voltage selection can operator-independently optimize cardiovascular CTA image acquisition parameters with improved image quality at reduced dose. KEY POINTS: • Automatic tube voltage selection optimizes tube voltage for each individual patient. • In this population, overall radiation dose decreased while image quality improved. • This tool may become valuable for improving dose/quality ratio.


Assuntos
Algoritmos , Angiografia/métodos , Aumento da Imagem/métodos , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Radiology ; 271(2): 574-84, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24475853

RESUMO

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.


Assuntos
Algoritmos , Angiografia/métodos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Imagens de Fantasmas , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Stents , Trombose/diagnóstico por imagem , Trombose/etiologia , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
8.
Forensic Sci Med Pathol ; 10(2): 170-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24443143

RESUMO

PURPOSE: To compare low-dose computed tomography (CT) with standard CT and conventional radiography (CR) regarding delineation of body packs and radiation dose. METHODS: Nine samples of illicit drugs including cocaine, heroin, and hashish were positioned in the rectum of a 121.5 kg pig cadaver. Each sample was scanned on a 64-row MDCT with 120 kV: one standard modulated pelvic protocol (STD), and without modulation at 80 mA (LD80), 30 mA (LD30), and 10 mA (LD10). Additionally, conventional abdominal anterior-posterior radiographs (77 kV and 106 ± 13 mA) were taken. Body pack characteristics (wrapping, content, shape) were rated independently by two radiologists and summarized to a delineation score from 0 to 9 with scores ≥6 representing sufficient delineation. Mean delineation scores were calculated for CR and CT protocols. These were additionally differentiated for readings in soft tissue (S), lung (L), user defined, variable window settings (V), and in cumulative window evaluation including all the other window settings (SLV). Effective doses were calculated (mSv). RESULTS: The CR delineation score was insufficient (3.1 ± 2.5; 2.4 ± 0.3 mSv). For CT, the SLV window setting performed best (p < 0.01). Its score significantly (p < 0.01) declined with decreasing effective radiation doses: STD (8.8 ± 0.5; 10.6 mSv), LD80 (8.2 ± 0.7; 2.6 mSv), LD30 (6.8 ± 1.3; 1.0 mSv), and LD10 (4.6 ± 1.9; 0.3 mSv). Thus, LD30 was the protocol using the lowest but sufficient dose. Moreover, for LD30 further differentiation between the particular window settings resulted in scores of 6.4 ± 1.3 (L), 6.3 ± 1.2 (V), and 3.1 ± 1.0 (S). CONCLUSIONS: With appropriate window settings, low-dose CT at 30 mA allowed for sufficient body-pack delineation below the dose of CR, which itself performed insufficient.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Drogas Ilícitas , Tomografia Computadorizada Multidetectores/métodos , Doses de Radiação , Animais , Crime , Modelos Animais , Pelve/diagnóstico por imagem , Radiografia Abdominal , Suínos , Viagem
9.
Eur Radiol ; 24(2): 519-26, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24192980

RESUMO

OBJECTIVES: This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). METHODS: cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFVM segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFVA calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. RESULTS: The final EFVA (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P < 0.001). A mean of 3.9 ± 1.9 manual border edits were performed to optimize the automated process. The software prototype required significantly less time to perform the measurements (135.6 ± 24.6 s vs. 314.3 ± 76.3 s, P < 0.001) and showed high reliability (ICC > 0.9). CONCLUSIONS: Automated EFVA quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. KEY POINTS: • Manual epicardial fat volume quantification correlates with risk factors but is time-consuming. • The novel software prototype automates measurement of epicardial fat volume with good accuracy. • This novel approach is less time-consuming and could be incorporated into clinical workflow.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Design de Software
10.
Expert Rev Cardiovasc Ther ; 11(4): 403-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23570353

RESUMO

Iterative techniques are a valuable computed tomography image reconstruction alternative to filtered back projection. In repetitive cycles, iterative algorithms reduce image noise virtually independently of spatial resolution. In light of substantially decreased image noise, tube voltage or current reductions are enabled, resulting in significant radiation dose savings while preserving image quality. Moreover, iterative reconstruction techniques have the advantage of minimizing calcium blooming and metal artifacts. Iterative reconstruction may therefore lead to more exact coronary artery evaluation at constant x-ray tube settings and appears beneficial in clinically challenging scenarios such as overly obese patients, calcified coronary arteries and presence of iatrogenic hardware. For cardiac computed tomography, iterative reconstruction represents a promising and readily available tool.


Assuntos
Artefatos , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Lesões por Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/métodos , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA