Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 21(8): 1783-93, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22714976

RESUMO

PURPOSE: Although most in vitro studies indicate that collagen is a suitable biomaterial for tendon and ligament tissue engineering, in vivo studies of implanted collagen for regeneration of these tissues are still lacking. The objectives of this study were the following: (1) to investigate the regeneration of the central third of the ovine patellar tendon using implants made of an open array of collagen fibres (reconstituted, extruded bovine collagen); and (2) to compare two collagen crosslinking chemistries: carbodiimide and carbodiimide associated with ethyleneglycoldiglycidylether. METHODS: Forty-eight Welsh Mountain sheep were operated on their right hind leg. The central third of patellar tendon was removed and substituted with carbodiimide (n = 16) and carbodiimide-ethyleneglycoldiglycidylether-crosslinked implants (n = 16). In the control group the defect was left empty (n = 16). The central third of contralateral unoperated tendons was used as positive controls. Half of the sheep in each group were killed at 3- and 6-month time points. After proper dissection, tendon sub-units (medial, central and lateral) were tested to failure (n = 6 for each group), whilst 2 non-dissected samples were used for histology. RESULTS: Both the implants had significantly lower stress to failure and modulus with respect to native tendon at both 3- and at 6-month time points. The implants did not statistically differ in stress to failure, whilst carbodiimide-crosslinked implants had significantly higher modulus than carbodiimide-ethyleneglycoldiglycidylether-crosslinked implants both at 3 and at 6 months. Histology showed carbodiimide-crosslinked implants to have a better integration with the native tendon than carbodiimide-ethyleneglycoldiglycidylether-crosslinked implants. Carbodiimide-crosslinked implants appeared partially resorbed and showed increased tissue ingrowth with respect to carbodiimide-ethyleneglycoldiglycidylether-crosslinked implants. CONCLUSIONS: To deliver collagen implants as an open array of fibres allows optimal tendon-implant integration and good ingrowth of regenerated tissue. In the present study the resorption rate of both the examined implants was too low due to the high level of crosslinking. This led to only minor substitution of the implant with regenerated tissue, which in turn produced a low-strength implanted region. Further studies are needed to find the right balance between strength and resorption rate of collagen fibres.


Assuntos
Ligamento Patelar/fisiologia , Ligamento Patelar/cirurgia , Próteses e Implantes , Regeneração/fisiologia , Engenharia Tecidual/métodos , Animais , Carbodi-Imidas/química , Colágenos Fibrilares/química , Teste de Materiais , Modelos Animais , Ligamento Patelar/lesões , Ovinos , Joelho de Quadrúpedes/cirurgia , Estresse Mecânico
2.
Biotechnol Prog ; 20(3): 841-50, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15176890

RESUMO

The development of a protein-mediated dual functional affinity adsorption of plasmid DNA is described in this work. The affinity ligand for the plasmid DNA comprises a fusion protein with glutathione-S-transferase (GST) as the fusion partner with a zinc finger protein. The protein ligand is first bound to the adsorbent by affinity interaction between the GST moeity and gluthathione that is covalently immobilized to the base matrix. The plasmid binding is then enabled via the zinc finger protein and a specific nucleotide sequence inserted into the DNA. At lower loadings, the binding of the DNA onto the Fractogel, Sepharose, and Streamline matrices was 0.0078 +/- 0.0013, 0.0095 +/- 0.0016, and 0.0080 +/- 0.0006 mg, respectively, to 50 microL of adsorbent. At a higher DNA challenge, the corresponding amounts were 0.0179 +/- 0.0043, 0.0219 +/- 0.0035, and 0.0190 +/- 0.0041 mg, respectively. The relatively constant amounts bound to the three adsorbents indicated that the large DNA molecule was unable to utilize the available zinc finger sites that were located in the internal pores and binding was largely a surface adsorption phenomenon. Utilization of the zinc finger binding sites was shown to be highest for the Fractogel adsorbent. The adsorbed material was eluted with reduced glutathione, and the eluted efficiency for the DNA was between 23% and 27%. The protein elution profile appeared to match the adsorption profiles with significantly higher recoveries of bound GST-zinc finger protein.


Assuntos
Cromatografia de Afinidade/métodos , Cromatografia em Gel/métodos , Proteínas de Ligação a DNA/química , Glutationa/química , Plasmídeos/química , Plasmídeos/isolamento & purificação , Adsorção , Ligação Proteica , Proteínas Recombinantes de Fusão/química , Dedos de Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA