Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Glaucoma ; 26(4): 311-314, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26859357

RESUMO

PURPOSE: To compare sequential glaucoma drainage device (GDD) implantation with transscleral diode cyclophotocoagulation (CPC) following failure of a primary GDD. MATERIALS AND METHODS: A retrospective review of all patients who underwent GDD implantation at a single institution over 10 years. Patients who required an additional GDD and/or CPC were analyzed. Success was defined as absence of loss of light perception, reoperation for glaucoma, and intraocular pressure (IOP) >21 or <6 at 2 consecutive visits after an initial 3-month period. RESULTS: Thirty-two patients received sequential GDD. Twenty-one underwent CPC. Cohorts were statistically similar in regards to age, sex, race, and number of previous surgeries. Preoperatively, the GDD cohort had a lower IOP and better visual acuity. The mean length of follow-up was 37.9 months for the GDD group and 46.3 months for CPC. Both procedures significantly reduced IOP; however, CPC led to a greater reduction (P=0.0172). Survival analysis found the 5-year probability of surgical success to be 65.3% for sequential GDD and 58.0% for CPC (P=0.8678). No cases of phthisis occurred in either group. There were 2 cases of endophthalmitis (6.3%) in the GDD group, and none in the CPC group. In eyes without preexisting corneal edema, estimated corneal decompensation probability at 3 years was 31.6% for GDD and 6.7% for CPC (P=0.0828). CONCLUSIONS: Sequential GDD and CPC are both effective at reducing IOP following the failure of a primary GDD. CPC after GDD failure warrants further investigation as it led to a greater reduction in IOP with fewer serious adverse events.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Fotocoagulação , Implantação de Prótese/métodos , Idoso , Corpo Ciliar/cirurgia , Edema da Córnea , Endoftalmite , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Hipotensão Ocular/cirurgia , Reoperação/métodos , Estudos Retrospectivos , Falha de Tratamento , Acuidade Visual/fisiologia
2.
Ophthalmology ; 122(4): 748-54, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25542521

RESUMO

OBJECTIVE: To examine the associations of provider-patient communication, glaucoma medication adherence self-efficacy, and outcome expectations with glaucoma medication adherence. DESIGN: Prospective, observational cohort study. PARTICIPANTS: Two hundred seventy-nine patients with glaucoma who were newly prescribed or taking glaucoma medications were recruited at 6 ophthalmology clinics. METHODS: Patients' visits were video recorded and communication variables were coded using a detailed coding tool developed by the authors. Adherence was measured using Medication Event Monitoring Systems for 60 days after their visits. MAIN OUTCOME MEASURES: The following adherence variables were measured for the 60-day period after their visits: whether the patient took 80% or more of the prescribed doses, percentage of the correct number of prescribed doses taken each day, and percentage of the prescribed doses taken on time. RESULTS: Higher glaucoma medication adherence self-efficacy was associated positively with better adherence with all 3 measures. Black race was associated negatively with percentage of the correct number of doses taken each day (ß = -0.16; P < 0.05) and whether the patient took 80% or more of the prescribed doses (odds ratio, 0.37; 95% confidence interval, 0.16-0.86). Physician education about how to administer drops was associated positively with percentage of the correct number of doses taken each day (ß = 0.18; P < 0.01) and percentage of the prescribed doses taken on time (ß = 0.15; P < 0.05). CONCLUSIONS: These findings indicate that provider education about how to administer glaucoma drops and patient glaucoma medication adherence self-efficacy are associated positively with adherence.


Assuntos
Anti-Hipertensivos/administração & dosagem , Glaucoma/tratamento farmacológico , Comunicação em Saúde , Adesão à Medicação/estatística & dados numéricos , Oftalmologia , Educação de Pacientes como Assunto , Relações Médico-Paciente , Autoeficácia , Administração Tópica , Adulto , Idoso , Idoso de 80 Anos ou mais , Monitoramento de Medicamentos , Feminino , Glaucoma/psicologia , Conhecimentos, Atitudes e Prática em Saúde , Pessoal de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Estudos Prospectivos , Inquéritos e Questionários , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA