Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Am Heart J ; 151(1): 192-7, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16368317

RESUMO

BACKGROUND: Recent studies have shown that autologous bone marrow mononuclear cell (aBM-MNC) transplantation can be effectively performed in human beings either by the coronary route or by endoventricular injections. However, scanty data are available for patients undergoing coronary artery bypass grafting (CABG). Accordingly, the aim of this study was to evaluate the feasibility and safety of aBM-MNC transplantation in patients with recent myocardial infarction undergoing CABG. METHODS AND RESULTS: The study population included 36 consecutive patients with recent myocardial infarction (< 6 months) undergoing CABG. Eighteen patients (17 men, mean age 64 years) underwent CABG plus aBM-MNC transplantation, whereas 18 subjects undergoing conventional CABG (17 men, mean age 67 years) served as control subjects. Cell transplantation was performed by direct injections in the border zone of the recently infarcted area. An average number of 292 +/- 232 x 10(6) aBM-MNCs was injected in each patient. When compared with control subjects, transplanted patients showed higher values of troponin I peak after CABG (median values of 1.65 ng/mL vs 0.64 ng/mL, P < .001). No major transplant-related adverse event could be detected. During follow-up, transplanted patients had an improvement in left ventricular ejection fraction (from 0.46 to 0.51, P < .05) and wall motion score index (from 1.71 to 1.42, P < .01). The incidence of arrhythmias immediately after CABG and during follow-up was similar in the 2 groups. CONCLUSIONS: Our data support the idea that direct injection of aBM-MNCs in the myocardium during CABG is feasible and safe. Larger studies are needed to assess the efficacy of such an approach in patients undergoing CABG.


Assuntos
Transplante de Medula Óssea , Ponte de Artéria Coronária , Infarto do Miocárdio/cirurgia , Idoso , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
4.
J Interv Card Electrophysiol ; 10(1): 37-45, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14739748

RESUMO

BACKGROUND: In patients with biventricular pacing (BIV), triple-site pacing (TSP), i.e. standard biventricular cathodal pacing of the right and the left ventricle plus additional anodal capture of the right ventricle, is sometimes present. AIMS: To evaluate the incidence of TSP phenomenon, to examine TSP-related QRS changes, and to assess the effect of TSP on intraventricular resynchronization by means of tissue Doppler imaging (TDI). METHODS AND RESULTS: 23 patients with a first generation biventricular device (Medtronic 8040) and 16 patients with a new generation device (Medtronic 8042) were evaluated to look for the presence of TSP. TSP was found in 6 patients (26%) with the Medtronic 8040 (group I) and in 13 patients (81%) with the Medtronic 8042 device (group II). QRS duration decreased by 10 to 20 ms and QRS amplitude of leads I and aVL increased in almost all patients in group I during TSP modality. In group II, QRS morphology, duration and amplitude did not change as obviously. TDI analysis of the left ventricular (LV) basal segments showed significant shortening of the systole, together with a corresponding prolongation of the diastole, at the inferior wall of the LV, during TSP compared to standard BIV in all patients ( p < 0.01). Other LV segments did not show any change. Qualitative TDI electro-mechanical activation pattern of all LV segments improved in 22%, while it remained unchanged in 72%. CONCLUSIONS: TSP phenomenon can be identified in approximately a quarter of patients with the first-generation biventricular devices on the basis of the QRS morphology changes. In the second-generation biventricular pacemakers it can be demonstrated in the vast majority of patients. TSP may increase the effectiveness of cardiac resynchronization therapy by counteracting the regional activation delay located at the inferior wall of the LV.


Assuntos
Estimulação Cardíaca Artificial/métodos , Idoso , Ecocardiografia Doppler , Eletrocardiografia , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Contração Miocárdica , Marca-Passo Artificial , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA