Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Heart Valve Dis ; 25(4): 475-482, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-28009952

RESUMO

BACKGROUND: Functional mitral regurgitation (FMR) is common in patients with advanced heart failure and impaired left ventricular function. The study aim was to examine functional and hemodynamic effects at three months after MitraClip® implantation in high-risk surgical patients with FMR. METHODS: A group of 93 patients was rejected for surgical treatment by heart-team decisions due to an inacceptable risk for conventional mitral valve surgery. Between October 2011 and May 2015, 89 of these patients (96%) were treated successfully with MitraClip implantation. A subsequent complete follow up was performed over three months in 32 patients with FMR, including pro-brain natriuretic peptide (pro-BNP) measurements, six-minute walk test, echocardiography, and right heart catheterization. RESULTS: The patients (mean age 73 ± 7 years) presented with a mean left ventricular ejection fraction (LVEF) of 32 ± 13%, and mitral regurgitation (MR) grade ≥3 in 30 of 32 cases (93%). All patients suffered from severe FMR and were highly symptomatic (NYHA functional class III or IV). The mean logistic EuroSCORE was 33%. MitraClip implantation resulted in a significant clinical improvement and reverse cardiac remodelling with a decrease in LV end-diastolic and LV endsystolic diameters, while LVEF was unchanged. In addition, a statistically relevant reduction of systolic, diastolic and mean pulmonary artery pressures (PAPsystolic -7.2 mmHg, p = 0.011; PAPdiastolic -4.5 mmHg, p = 0.003; and PAPmean -5.3 mmHg, p = 0.007) were measured, while the cardiac index (+0.3 l/min/m2, p <0.001) and cardiac output (+0.5 l/min, p <0.001) were increased significantly. The 30-day mortality was 8.6% (n = 8). CONCLUSIONS: Among the study population, MitraClip implantation led to clinical improvement, reverse cardiac remodeling, and a sustained hemodynamic benefit during the three-month follow up period.


Assuntos
Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Insuficiência da Valva Mitral/etiologia , Instrumentos Cirúrgicos , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular
2.
Am Heart J ; 158(5): 822-828.e3, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19853704

RESUMO

BACKGROUND: The choice of radiographic contrast media for use in patients at increased risk of contrast-induced nephropathy (CIN) is of ongoing interest. METHODS: The current study is a prospective, multicenter, randomized, double-blind design comparing the renal effects of the non-ionic, iso-osmolal agent, iodixanol, versus the non-ionic, low-osmolal agent, iopamidol, in 526 subjects with impaired baseline renal function (chronic kidney disease) and diabetes mellitus undergoing diagnostic and/or therapeutic coronary angiographic procedures. The co-primary end points were the peak increase in serum creatinine (SCr) and the incidence of CIN (increase > or =0.5 mg/dL) in SCr from baseline within 3 days of receiving contrast media. RESULTS: In 418 evaluable subjects with complete postcontrast media SCr data, the median peak increase in SCr in the iodixanol arm was 0.10 mg/dL, whereas in the iopamidol arm, the median peak increase was 0.09 mg/dL (P = .13). The overall CIN incidence was 10.5% (11.2% % in the iodixanol arm and 9.8% in the iopamidol arm, P = .7). The volume of contrast media, volume of saline administered, frequency of coronary interventional procedures, and severity of baseline kidney disease and of diabetes mellitus were similar between treatments. CONCLUSIONS: In the present study, the overall rate of CIN in patients with chronic kidney disease and DM undergoing coronary angiographic procedures was 10.5%. There was no significant difference between iodixanol and iopamidol in either peak increase in SCr or risk of CIN.


Assuntos
Meios de Contraste/toxicidade , Angiografia Coronária/efeitos adversos , Iopamidol/toxicidade , Ácidos Tri-Iodobenzoicos/toxicidade , Idoso , Creatinina/sangue , Nefropatias Diabéticas/sangue , Método Duplo-Cego , Feminino , Humanos , Falência Renal Crônica/sangue , Masculino
3.
J Interv Cardiol ; 21(2): 158-66, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18248356

RESUMO

AIMS: Percutaneous coronary intervention (PCI) has been broadly established and often includes highly complex stenoses that require difficult navigation. The purpose of this study is to assess the feasibility of a new magnetic navigation system (MNS) to enable intracoronary guidewire deployment and PCI in daily clinical practice and to compare the 2D guidance to the virtual 3D angioscopy feature. METHODS AND RESULTS: We included 30 consecutive patients (pt) in whom 36 coronary arteries were PCI targets. Patients were randomized to guidewire steering by either 2D guidance or virtual 3D angioscopy (33%). In 31/36 (86%) interventions the MNS guidewire successfully passed the culprit stenosis and the procedure was accomplished by PCI. In 5/30 pt an MNS multivessel intervention was performed. Three of 5 unsuccessful procedures failed due to an unsuccessful recanalization of a subtotal chronic occlusion including 1 pt who required surgical intervention. In 2/36 procedures the magnetic guided intervention was performed effectively after prior conventional failure related to complex anatomy. The contrast medium amount needed to position the magnetic guidewire was 60 +/- 101 mL in 2D accomplished interventions vs. 14 +/- 15 mL in 3D procedures (p < 0.05). In 3 pt the MNS did not harm the implanted pacemaker or defibrillator system. CONCLUSION: Magnetic guided PCI is useful in selected patients. In our experience, success is less likely in evidence of a subtotal occlusion.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioscopia , Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/terapia , Vasos Coronários/cirurgia , Interface Usuário-Computador , Idoso , Meios de Contraste , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Estudos de Viabilidade , Feminino , Humanos , Masculino
4.
Eur Radiol ; 15(6): 1110-21, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15756551

RESUMO

The objective of this study is to evaluate multidetector CT (MDCT) in detecting and characterizing anomalous coronary arteries. Forty-four patients with anomalies of the coronaries were selected from a total of 1758 individuals examined with ECG-gated 4- and 16-row MDCT including thinMIP, MPR and VRT post-processing. Twenty-eight patients showed origin and course anomalies of the central coronary segments, and in this subgroup 13 were judged as "malignant" because of interarterial courses between the aortic root and the pulmonary trunk, either of the right coronary artery (n=11) or the left coronary artery (n=2). Twelve non-hemodynamic anomalies were found, affecting the coronary origins only (n=10) or the peripheral vessels courses (n=2). Four arteriovenous fistulas were present, all of them with complex arterial feeders. Regardless of vessel anatomy, coronary opacification was always possible by means of the systemic contrast agent, and the aberrant coronary arteries were visualized synoptically in direct relation to the great mediastinal vessels. In contrast to MDCT, selective cannulation and final diagnosis was possible in only 11 of the 20 catheter angiograms performed (accuracy of 55.0%). In conclusion, its non-invasiveness and precise visualization makes MDCT the standard of reference for evaluating anomalous coronary arteries.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Angiografia Coronária , Anomalias dos Vasos Coronários/epidemiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Incidência , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA