Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Med Phys ; 2020 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-33179276

RESUMO

When interacting with colleagues, patients, and members of the public, medical physicists are frequently asked questions about radiation doses, clinical benefits, and biological risks of medical imaging. This book collects some of the latest data and understanding on these subjects into a single concise and well-organized volume and makes it accessible to a wide variety of potential readers. The editors and many of the chapter authors are from Memorial Sloan Kettering Cancer Center. Despite the variety of authors, the content is well-organized and fits together seamlessly.

4.
J Vasc Interv Radiol ; 27(4): 593-600, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26948994

RESUMO

PURPOSE: To investigate changes in radiation dose and image quality using phantoms and hepatic embolization procedures performed with a new image processing technology (ClarityIQ) for a single-plane flat-detector-based interventional fluoroscopy system. MATERIALS AND METHODS: Phantom study was performed using acrylic sheets simulating different patient sizes. Air kerma rates (AKRs) were compared for different fluoroscopy modes and magnification modes without and with ClarityIQ. Repeat hepatic embolization procedures performed on the same lobe of the liver in the same patient by the same interventional radiologist between January 2013 and July 2014 without and with ClarityIQ were evaluated retrospectively. This included treatment of 33 hepatic lobes in 26 patients. Cumulative air kerma (CAK), kerma-area product (KAP), and factors affecting radiation dose were extracted from study metadata and compared. Blinded randomized image quality review was performed on arteriograms using a five-point scale. RESULTS: The phantom study revealed a significantly lower AKR (P < .005) with ClarityIQ. Repeated-measures analysis revealed a significant effect of ClarityIQ (P ≤ .001) on CAK and KAP, with reductions ranging between 9% and 85% (median, 67%) and between 5% and 89% (median, 75%), respectively, on a case-by-case basis. Mean reductions in CAK and KAP were 279 mGy and 134,030 mGy·cm(2), respectively. Image quality review scores were significantly lower (P ≤ .001) with ClarityIQ, effecting visualization of tumor vasculature and appearance of noise texture. CONCLUSIONS: ClarityIQ resulted in radiation dose reduction in the phantom study and in the hepatic embolization procedures, but with a decrease in subjective perceptions of image quality.


Assuntos
Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Melanoma/terapia , Imagens de Fantasmas , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista/instrumentação , Radiografia Intervencionista/métodos , Neoplasias Uveais/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Masculino , Melanoma/diagnóstico por imagem , Melanoma/secundário , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Software , Resultado do Tratamento
5.
Acad Radiol ; 21(6): 805-11, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24809321

RESUMO

RATIONALE AND OBJECTIVES: To evaluate knowledge-based iterative model reconstruction (IMR) to improve image quality and reduce radiation dose in coronary computed tomography angiography (cCTA). MATERIALS AND METHODS: We evaluated 45 consecutive cCTA studies, including 25 studies performed with an 80% systolic dose reduction using tube current modulation (TCM). Each study was reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (iDose(4)), and IMR in a diastolic phase. Additional systolic phase reconstructions were obtained for TCM studies. Mean pixel attenuation value and standard deviation (SD) were measured in the left ventricle and left main coronary artery. Subjective scores were obtained by two independent reviewers on a 5-point scale for definitions of contours of small coronary arteries (<3 mm), coronary calcifications, noncalcified plaque, and overall diagnostic confidence for the presence/absence of stenosis. RESULTS: There was no significant difference in pixel intensity among FBP, iDose(4), and IMR (P > .8). For diastolic phase images, noise amplitude in the left main coronary artery was reduced by a factor of 1.3 from FBP to iDose(4) (SD = 99 vs. 74; P = .005) and by a factor of 2.6 from iDose(4) to IMR (SD = 74 vs. 28; P < .001). For systolic phase TCM images, noise amplitude in the left main coronary artery was reduced by a factor of 2.3 from FBP to iDose(4) (SD = 322 vs. 142; P < .001) and by a factor of 3.0 from iDose(4) to IMR (SD = 142 vs. 48; P < .001). All four subjective image quality scores were significantly better with IMR compared to iDose(4) and FBP (P < .001). The reduction in image noise amplitude and improvement in image quality scores were greatest among obese patients. CONCLUSIONS: IMR reduces intravascular noise on cCTA by 86%-88% compared to FBP, and improves image quality at radiation exposure levels 80% below our standard technique.


Assuntos
Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Calcinose/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Ácidos Tri-Iodobenzoicos
6.
J Neurointerv Surg ; 6(4): 291-5, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23709582

RESUMO

BACKGROUND AND OBJECTIVE: Flow diverters are increasingly used for treatment of complex intracranial aneurysms. The purpose of this study was to compare the pipeline embolization device (PED) and traditional embolization strategies in terms of fluoroscopy and procedure time. MATERIAL AND METHODS: Fluoroscopy and procedure times (in minutes) were retrospectively analyzed and compared between 127 patients treated with the PED, 86 patients treated with single stage stent assisted coiling (SAC), and 16 patients treated with Onyx HD 500 at our institution. A multivariate logistic regression analysis was performed to determine independent predictors of fluoroscopy and procedure time. RESULTS: The three groups were comparable with respect to patient age, gender, and ruptured/unruptured aneurysm status. Aneurysms treated with the PED were significantly larger than stent coiled aneurysms, and aneurysm location distribution differed significantly between the three groups. Mean fluoroscopy time was significantly increased in the SAC (55±31 min, p<0.001) and Onyx HD 500 (91±36 min, p<0.001) groups relative to the PED group (34±23 min). Likewise, mean procedure time was significantly longer in SAC (155±50 min, p<0.001) and Onyx HD 500 (176±65 min, p<0.001) patients compared with PED patients (131±36 min). In multivariate analysis, SAC/Onyx HD 500 versus PED independently predicted longer procedure and fluoroscopy times. CONCLUSIONS: PED treatment requires significantly shorter fluoroscopy and procedure times compared with SAC and Onyx HD 500. The results of this study may be used by advocates of flow diverters as an additional argument for using this treatment modality to treat intracranial aneurysms.


Assuntos
Prótese Vascular , Embolização Terapêutica/métodos , Fluoroscopia/métodos , Aneurisma Intracraniano/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/estatística & dados numéricos , Embolização Terapêutica/instrumentação , Embolização Terapêutica/estatística & dados numéricos , Feminino , Fluoroscopia/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Fatores de Tempo , Adulto Jovem
7.
AJR Am J Roentgenol ; 202(1): 124-35, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24370137

RESUMO

OBJECTIVE: The costs of an ultrasound-CT protocol and a CT-only protocol for an appendicitis evaluation are compared. For the ultrasound-CT protocol, patients with right lower quadrant abdominal pain undergo an ultrasound examination. If it is positive for appendicitis, they are sent directly to surgery, avoiding CT. MATERIALS AND METHODS: A comparative effectiveness research study was conducted. The costs of imaging tests, excess surgeries, and excess surgical deaths for the ultrasound-CT protocol and the costs of imaging tests and excess cancer deaths in the CT-only protocol were estimated. Data sources were Centers for Medicare & Medicaid Services (CMS) datasets, national hospital discharge surveys, radiology information system cases, and U.S. Census Bureau life tables. A meta-analysis and sensitivity analyses were also conducted. RESULTS: The meta-analysis showed a positive predictive value of 92.5% for CT and 91.0% for ultrasound. Analysis of CMS files showed that utilization of CT was almost exactly 2.0 examinations (one abdominal and one pelvic) per patient and for ultrasound was almost nil. The cost of this imaging protocol was $547 per patient, whereas the cost of a limited ultrasound study would be $88 per patient. For the total U.S. population, the cost savings in imaging minus the cost of extra surgeries and extra surgical deaths is $24.9 million per year. Following model VII proposed by the Committee on the Biological Effects of Ionizing Radiation (BEIR), which is known as "BEIR VII," the avoidance of a 12.4-mSv exposure for 262,500 persons would prevent 180 excess cancer deaths. The value of the years of life lost would be $339.5 million. The sensitivity analyses indicate that the cost savings are robust. CONCLUSION: An ultrasound-CT protocol for appendicitis evaluation offers potentially large savings over the standard CT-only protocol. There are moderate savings from using a less expensive imaging technique despite extra surgeries and large savings from radiation exposure avoided.


Assuntos
Apendicite/diagnóstico por imagem , Redução de Custos , Proteção Radiológica/economia , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/economia , Ultrassonografia/economia , Algoritmos , Pesquisa Comparativa da Efetividade , Humanos , Doses de Radiação
8.
Acad Radiol ; 16(8): 951-6, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19375949

RESUMO

RATIONALE AND OBJECTIVES: To determine whether angled gantry acquisition might be used to image the heart with a shorter scan length and reduced breast exposure during coronary computed tomography angiography. MATERIALS AND METHODS: One hundred consecutive coronary computed tomography angiography examinations of female patients were retrospectively evaluated to define the angle between the long axis of the left heart and the axial imaging plane. The scan length required to image the entire left ventricle along with the coronary arteries was measured for an axial scan plane as well as for a scan plane parallel to the long axis of the left heart. The overlap between these imaging volumes and the lower portion of the breast was measured. RESULTS: The long axis of the left heart varied from 7 degrees to 54 degrees off the axial plane (mean 32 degrees +/- 7 degrees ). The required scan length to include the entire left ventricle and coronary arteries ranged from 8.2 to 12.4 cm (mean, 10.0 +/- 0.9 cm) for the axial scan plane and 5.6-10.1 cm (mean, 7.5 +/- 0.8 cm) for a scan plane parallel to the long axis of the heart (P < .001). cCTA in the axial plane required a 7.4 +/- 1.6 cm overlap with the lower breast, whereas cCTA in the long axis of the heart reduced the overlap to 4.5 +/- 1.8 cm (P < .001). CONCLUSIONS: Using an angled gantry approach, the coronary arteries can be fully imaged in a plane along the long axis of the left heart with a single 10-cm acquisition and with substantial reduction in amount of breast tissue within the irradiated field.


Assuntos
Carga Corporal (Radioterapia) , Mama , Angiografia Coronária/métodos , Proteção Radiológica/métodos , Radiometria , Tomografia Computadorizada por Raios X/métodos , Doenças Mamárias/etiologia , Doenças Mamárias/prevenção & controle , Angiografia Coronária/efeitos adversos , Feminino , Humanos , Doses de Radiação , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/efeitos adversos
9.
AJR Am J Roentgenol ; 192(4): 866-72, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19304688

RESUMO

OBJECTIVE: "Triple rule-out" coronary CT angiography (CTA) using 64-MDCT technology is a new approach for evaluating emergency department patients presenting with symptoms suggestive of acute coronary syndrome (ACS). Our objective was to evaluate the reduction in effective radiation dose through the use of tube current modulation in patients who underwent a triple rule-out coronary CTA evaluation and to document how effective radiation dose was impacted by patient age, sex, and body mass index (BMI). MATERIALS AND METHODS: A retrospective analysis of triple rule-out coronary CTA examinations performed on a 64-MDCT scanner was ordered on a prospective cohort of 267 consecutive low- to moderate-risk emergency department patients with suspected ACS from a single university hospital between October 2006 and March 2008. Tube current modulation was generally used in patients with heart rates below 65 beats per minute during the second half of the study period as a way to reduce radiation exposure. We calculated effective radiation exposure using actual patient coronary CTA scanning parameters by age, sex, and BMI. RESULTS: Among the 172 patients evaluated without tube current modulation, effective dose averaged (+/- SD) 18.0 +/- 5.6 mSv (range, 9.9-31.3 mSv). Of the 95 patients who underwent CTA examination with tube current modulation, effective dose was significantly lower at 8.75 +/- 2.64 mSv (range, 5.4-16.6 mSv; p < 0.0001) and image quality was better (p < 0.0001) as compared with examinations without tube current modulation. There were no significant radiation differences by patient age, but tube current modulation decreased radiation exposure by at least half. Among the studies in which tube current modulation was not used, women received less radiation than men (17.0 vs 19.5 mSv, respectively; p < 0.001). For the studies with tube current modulation, there were no radiation differences by sex. Obese patients received significantly more radiation than overweight and normal-weight patients in the non-tube current modulation groups (20.9 mSv vs 15.0 and 14.9 mSv, respectively; p < 0.0001) and in the tube current modulation groups (10.3 mSv vs 7.6 and 7.1 mSv, p < 0.0001). CONCLUSION: The overall effective radiation dose for triple rule-out coronary CTA was reduced by more than 50% with ECG-based tube current modulation without loss of image quality. Tube current modulation should be used for triple rule-out coronary CTA examinations whenever possible.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Angiografia Coronária/métodos , Eletrocardiografia , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA