Ophthalmic Surg Lasers Imaging Retina ; 48(2): 170-174, 2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28195621

RESUMO

The purpose of this study was to report on a case of Terson's syndrome (TS) using a novel instrument and technique to harvest posterior pole pathology from a postmortem eye. A modified ocular clamp was used to remove the posterior pole from the postmortem enucleated eye. Gross photographs were taken and an ocular sample of the posterior pole was sent to The New York Eye and Ear Pathology Laboratory. TS was identified from gross pathology and histologic examinations. The case history was consistent with that diagnosis. The authors concluded that high-quality gross and histopathologic examination of the posterior pole can be obtained with this novel instrument and technique. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:170-174.].


Assuntos
Biópsia/métodos , Hemorragias Intracranianas/complicações , Segmento Posterior do Olho/patologia , Retina/patologia , Hemorragia Retiniana/patologia , Corpo Vítreo/patologia , Hemorragia Vítrea/patologia , Cadáver , Humanos , Hemorragias Intracranianas/diagnóstico , Masculino , Pessoa de Meia-Idade , Hemorragia Retiniana/etiologia , Síndrome , Tomografia Computadorizada por Raios X , Hemorragia Vítrea/etiologia