Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Radiol Case Rep ; 14(6): 723-728, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30988864

RESUMO

Visceral artery aneurysms are very rare and aneurysms of the celiac trunk are the rarest ones: they are in most cases asymptomatic and their detection is frequently incidental. In this article we report the case of a man affected by severe abdominal pain with a huge aneurysm of the celiac trunk, first successfully treated with coil embolization, but, after 10 months, another endovascular embolization was required for deployment of the metallic coils previously released, ahead into the fund of the sac with recanalization of the aneurysm. A second endovascular treatment was performed with other coils and Amplatzer-Plug. The high risk of rupture makes treatment of such aneurysms mandatory and surgery is still considered the gold standard therapy of VAA, but, due to its high morbidity and mortality risks, in the last years, it has been widely replaced by endovascular embolization. An effective endovascular embolization requires not only the complete filling of the aneurysmal sac, but also the complete vascular exclusion of its in-flow and out-flow tracts, to reduce the risk of its anterograde or retrograde reperfusion.

2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 5794-5797, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441652

RESUMO

Today clinicians may access large medical datasets, but very few systems have been designed to allow a practical and efficient exploration of data directly in critical medical environments such as operating rooms (OR). This work aims to assess during tests in laboratory and clinical settings a Surgery Touchless System (STS). This system allows clinicians to interact with medical images by using two different approaches: a gesture recognition and a voice recognition based system. These two methods are based on the use of a Microsoft Kinect and of a selective microphone, respectively. The STS allows navigating in a specifically designed interface, to perform several tasks, among others, to manipulate biomedical images. In this article, we assessed both the recognitions approaches in laboratory with 5 users. In addition, the STS was tested using only the voice-based recognition approach in clinical settings. The assessment was performed during three procedures by two interventionalradiologists. The five volunteers and the 2 radiologists filled two questionnaires to assess the system. The system usability was positively evaluated in laboratory tests. From clinical trials emerged that the STS was considered safe and useful by both the radiologists: they used the system an averaged number of times of 10 and 15 for patients, and found the system useful. These promising results allow considering this system useful for providing information not otherwise accessible and limiting the impact of human error during the operation. Future work will be focused on the use of the STS on a high number and different types of procedure.


Assuntos
Computadores , Interpretação de Imagem Assistida por Computador , Salas Cirúrgicas , Interface para o Reconhecimento da Fala , Interface Usuário-Computador , Gestos , Humanos , Procedimentos Cirúrgicos Operatórios
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 4529-4532, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29060904

RESUMO

Laser Ablation (LA) is a minimally invasive technique for tumor removal. The laser light is guided into the target tissue by a fiber optic applicator; thus the physical features of the applicator tip strongly influence size and shape of the tissue lesion. This study aims to verify the geometry of the lesion achieved by a tapered-tip applicator, and to investigate the percentage of thermally damaged cells induced by the tapered-tip fiber optic applicator. A theoretical model was implemented to simulate: i) the distribution of laser light fluence rate in the tissue through Monte Carlo method, ii) the induced temperature distribution, by means of the Bio Heat Equation, iii) the tissue injury, by Arrhenius integral. The results obtained by the implementation of the theoretical model were experimentally assessed. Ex vivo porcine liver underwent LA with tapered-tip applicator, at different laser settings (laser power of 1 W and 1.7 W, deposited energy equal to 330 J and 500 J, respectively). Almost spherical volume lesions were produced. The thermal damage was assessed by measuring the diameter of the circular-shaped lesion. The comparison between experimental results and theoretical prediction shows that the thermal damage discriminated by visual inspection always corresponds to a percentage of damaged cells of 96%. A tapered-tip applicator allows obtaining localized and reproducible damage close to spherical shape, whose diameter is related to the laser settings, and the simple theoretical model described is suitable to predict the effects, in terms of thermal damage, on ex vivo liver. Further trials should be addressed to adapt the model also on in vivo tissue, aiming to develop a tool useful to support the physician in clinical application of LA.


Assuntos
Tecnologia de Fibra Óptica , Animais , Hipertermia Induzida , Terapia a Laser , Lasers , Modelos Teóricos , Suínos
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 344-347, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28268347

RESUMO

Radiofrequency ablation (RFA) is a minimally invasive procedure used to treat tumors by means of hyperthermia, mostly through percutaneous approach. The tissue temperature plays a pivotal role in the achievement of the target volume heating, while sparing the surrounding healthy tissue from thermal damage. Several techniques for thermometry during RFA are investigated, most of them based on the use of single-point measurement system (e.g., thermocouples). The measurement of temperature map is crucial for the real-time control and fine adjustment of the treatment settings, to optimize the shape and size of the ablated volume. The recent interest about fiber optic sensors and, among them, fiber Bragg gratings (FBGs) for the monitoring of thermal effects motivated further investigation. In particular, the feature of FBGs to form an array of several elements, thus to be inscribed within the same fiber, allows the use of a single probe for the multi-points monitoring of the tissue temperature during RFA. Hence, the aim of this study is the development and characterization of a needle-like probe embedding an array of three FBGs, which was tested on pig liver during in vivo trials. The needle allows a safe and easy insertion of the fiber optic within the liver. It was inserted by ultrasound guidance into the liver, and monitored the change of tissue temperature during RFA controlled by the roll-off technique. Also the measurement error induced by breathing movements of the liver was assessed (less than 3 °C). Results encourage the use of the probe in clinical settings, as well as the improvement of some features, e.g., a higher number of FBGs for performing quasi-distributed measurement.


Assuntos
Ablação por Cateter/métodos , Fígado/cirurgia , Temperatura , Animais , Eletrodos , Feminino , Tecnologia de Fibra Óptica , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Movimento , Agulhas , Respiração , Sus scrofa , Ultrassonografia
5.
Eur J Surg Oncol ; 41(12): 1699-705, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26433708

RESUMO

OBJECTIVE: The aim of the present study was to assess the temperature map and its reproducibility while applying two different MWA systems (915 MHz vs 2.45 GHz) in ex vivo porcine livers. MATERIALS AND METHODS: Fifteen fresh pig livers were treated using the two antennae at three different settings: treatment time of 10 min and power of 45 W for both systems; 4 min and 100 W for the 2.45 GHz system. Trends of temperature were recorded during all procedures by means of fiber optic-based probes located at five fixed distances from the antenna, ranging between 10 mm and 30 mm. Each trial was repeated twice to assess the reproducibility of temperature distribution. RESULTS: Temperature as function of distance from the antenna can be modeled by a decreasing exponential trend. At the same settings, temperature obtained with the 2.45 GHz system was higher than that obtained with the 915 MHz thus resulting into a wider area of ablation (diameter 17 mm vs 15 mm). Both systems showed good reproducibility in terms of temperature distribution (root mean squared difference for both systems ranged between 2.8 °C and 3.4 °C). CONCLUSIONS: When both MWA systems are applied, a decreasing exponential model can predict the temperature map. The 2.45 GHz antenna causes higher temperatures as compared to the 915 MHz thus, resulting into larger areas of ablation. Both systems showed good reproducibility although better results were achieved with the 2.45 GHz antenna.


Assuntos
Ablação por Cateter/métodos , Fígado/cirurgia , Micro-Ondas/uso terapêutico , Animais , Modelos Animais de Doenças , Hepatopatias/cirurgia , Reprodutibilidade dos Testes , Suínos , Temperatura
6.
Med Eng Phys ; 37(7): 631-41, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25979670

RESUMO

Laser Ablation (LA) is a minimally-invasive procedure for tumor treatment. LA outcomes depend on the heat distribution inside tissues and require accurate temperature measurement during the procedure. Magnetic resonance imaging (MRI) allows a non-invasive and three-dimensional thermometry of the organ undergoing LA. In this study, the temperature distribution within two swine pancreases and three swine livers undergoing LA (Nd:YAG, power: 2 W, treatment time: 4 min) was monitored by a 1.5-T MR scanner, utilizing two T1-weighted sequences (IRTF and SRTF). The signal intensity in four regions of interest, placed at different distances from the laser applicator, was related to temperature variations monitored in the same regions by twelve fiber Bragg grating sensors. The relationship between the signal intensity and temperature increase was calculated to obtain the calibration curve and to evaluate accuracy, sensibility and precision of each sequence. This is the first study of MR-based thermometry during LA on pancreas. More specifically, the IRTF sequence provides the highest temperature sensitivity in both liver (1.8 ± 0.2 °C(-1)) and pancreas (1.8 ± 0.5 °C(-1)) and the lowest precision and accuracy. SRTF sequence on pancreas presents the highest accuracy and precision (MODSFRT = -0.1 °C and LOASFRT = [-2.3; 2.1] °C).


Assuntos
Terapia a Laser/métodos , Fígado/cirurgia , Imagem por Ressonância Magnética Intervencionista/métodos , Pâncreas/cirurgia , Termometria/métodos , Animais , Calibragem , Terapia a Laser/instrumentação , Lasers , Modelos Lineares , Fígado/anatomia & histologia , Fígado/fisiologia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Pâncreas/anatomia & histologia , Pâncreas/fisiologia , Suínos , Temperatura , Termometria/instrumentação
7.
Artigo em Inglês | MEDLINE | ID: mdl-24109703

RESUMO

Laser interstitial thermotherapy (LITT) is a minimally invasive technique used to thermally destroy tumour cells. Being based on hyperthermia, LITT outcome depends on the temperature distribution inside the tissue. Recently, CT scan thermometry, based on the dependence of the CT number (HU) on tissue temperature (T) has been introduced during LITT; it is an attractive approach to monitor T because it overcomes the concerns related to the invasiveness. We performed LITT on nine ex vivo swine livers at three different laser powers, (P=1.5 W, P=3 W, P=5 W) with a constant treatment time t=200 s; HU is averaged on two ellipsoidal regions of interest (ROI) of 0.2 cm2, placed at two distances from the applicator (d=3.6 mm and d=8.7 mm); a reference ROI was placed away from the applicator (d=30 mm). The aim of this study is twofold: 1) to evaluate the effect of the T increase in terms of HU variation in ex vivo swine livers undergoing LITT; and 2) to estimate the P value for tissue vaporization. To the best of our knowledge, this is the first study focused on the HU variation in swine livers undergoing LITT at different P. The reported findings could be useful to assess the effect of LITT on the liver in terms of both T changes and tissue vaporization, with the aim to obtain an effective therapy.


Assuntos
Hipertermia Induzida/instrumentação , Neoplasias/terapia , Tomografia Computadorizada por Raios X/instrumentação , Animais , Desenho de Equipamento , Hipertermia Induzida/métodos , Terapia a Laser/instrumentação , Lasers , Fígado/patologia , Neoplasias/patologia , Imagens de Fantasmas , Reprodutibilidade dos Testes , Suínos , Temperatura , Termometria , Tomografia Computadorizada por Raios X/métodos , Volatilização
8.
Phys Med Biol ; 58(16): 5705-16, 2013 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-23899610

RESUMO

Laser interstitial thermotherapy (LITT) is employed to destroy tumors in organs, and its outcome strongly depends on the temperature distribution inside the treated tissue. The recent introduction of computed tomography (CT) scan thermometry, based on the CT number dependence of the tissue with temperature, overcomes the invasiveness of other techniques used to monitor temperature during LITT. The averaged CT number (ROI = 0.02 cm(2)) of an ex vivo swine pancreas is monitored during LITT (Nd:YAG laser power of 3 W, treatment time: 120 s) at different distances from the applicator (from 4 to 30 mm). The averaged CT number shows a clear decrease during treatment: it is highest at 4 mm from the applicator (mean variation in the whole treatment of -0.256 HU s(-1)) and negligible at 30 mm, since the highest temperature increase is present close to the applicator (i.e., 45 °C at 4 mm and 25 °C at 6 mm). To obtain the relationship between CT numbers and pancreas temperature, the reference temperature was measured by 12 fiber Bragg grating sensors. The CT number decreases as a function of temperature, showing a nonlinear trend with a mean thermal sensitivity of -0.50 HU °C(-1). Results here reported are the first assessment of pancreatic CT number dependence on temperature, at the best of our knowledge. Findings can be useful to further investigate CT scan thermometry during LITT on the pancreas.


Assuntos
Técnicas de Ablação , Lasers , Pâncreas/diagnóstico por imagem , Pâncreas/efeitos da radiação , Suínos , Termometria/métodos , Tomografia Computadorizada por Raios X , Animais , Calibragem , Estudos de Viabilidade , Temperatura
9.
Int J Comput Assist Radiol Surg ; 8(5): 837-48, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23377707

RESUMO

PURPOSE: Percutaneous lung biopsies (PLBs) performed for the evaluation of pulmonary masses require image guidance to avoid critical structures. A new CT navigation system (SIRIO, "Sistema robotizzato assistito per il puntamento intraoperatorio") for PLBs was validated. METHODS: The local Institutional Review Board approved this retrospective study. Image-guided PLBs in 197 patients were performed with a CT navigation system (SIRIO). The procedures were reviewed based on the number of CT scans, patients' radiation exposure and procedural time recorded. Comparison was performed with a group of 72 patients undergoing standard CT-guided PLBs. Sensitivity, specificity and overall diagnostic accuracy were assessed in both groups. RESULTS: SIRIO-guided PLBs showed a significant reduction in procedure time, number of required CT scans and the radiation dose administered to patients ([Formula: see text]). In terms of diagnostic accuracy, SIRIO proved to be more accurate for small-sized lesions ([Formula: see text]20 mm) than standard CT-guidance. CONCLUSION: SIRIO proved to be a reliable and effective tool when performing CT-guided PLBs and was especially useful for sampling small ([Formula: see text]20 mm) lesions.


Assuntos
Fluoroscopia/métodos , Biópsia Guiada por Imagem/métodos , Pneumopatias/diagnóstico , Neoplasias Pulmonares/diagnóstico , Radiografia Intervencionista/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Interface Usuário-Computador , Idoso , Desenho de Equipamento , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
Radiol Med ; 118(5): 851-62, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22986696

RESUMO

PURPOSE: The authors sought to determine the diagnostic performance of dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging in the evaluation of prostate cancer before and after transrectal high-intensity focused ultrasound (HIFU) treatment. MATERIALS AND METHODS: We analysed 25 patients with prostate cancer. The prostate-specific antigen (PSA) value was evaluated 1, 4 and 6 months after treatment. DCE-MR imaging was performed the day prior to and 1, 4 and 6 months after HIFU treatment. Transrectal prostate biopsies were obtained at the time of diagnosis and 6 months after treatment. RESULTS: Before treatment, intraglandular lesions were considered to be potential sites of neoplasm and subsequently confirmed as sites of prostate adenocarcinoma in all 25 patients based on prostatespecific antigen (PSA) values and histological examinations (rho=1; p<0.001). Using histology as the gold standard, DCE-MR imaging displayed 100% sensitivity, 100% specificity, 100% positive predictive value and 100% negative predictive value before treatment. After HIFU treatment, DCE-MR imaging showed 100% sensitivity and 96% specificity. CONCLUSIONS: DCE-MR imaging can be used to visualise prostate adenocarcinoma. Several morphological and postgadolinium modifications in the follow-up DCE-MR images after HIFU treatment were also observed.


Assuntos
Adenocarcinoma/patologia , Adenocarcinoma/cirurgia , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Ultrassom Focalizado Transretal de Alta Intensidade , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Meios de Contraste , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Meglumina , Pessoa de Meia-Idade , Compostos Organometálicos , Valor Preditivo dos Testes , Antígeno Prostático Específico/sangue , Sensibilidade e Especificidade , Resultado do Tratamento
11.
Radiol Med ; 117(7): 1125-38, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22434494

RESUMO

PURPOSE: This study was done to determine the diagnostic accuracy of magnetic resonance (MR) imaging in patients with rectal carcinoma by comparing post-chemoradiation MR imaging with pathological specimens. MATERIALS AND METHODS: We enrolled 39 patients with locally advanced rectal cancer. All patients received chemoradiation therapy before surgery and neoadjuvant chemoradiation therapy followed by MR imaging. MR images were analysed by a team of two expert radiologists unaware of the clinical and histopathological findings. RESULTS: Following neoadjuvant chemoradiation therapy, the analysis of MR images showed 23 (59%) patients with a rectal disease staged ≤T2 and 16 (41%) with a disease staged >T2. Post-treatment histological staging (TNM) revealed 13 patients with a disease >T2 and 26 patients with a disease ≤T2. Cohen's kappa to measure concordance between post-chemoradiation MR staging and histological response showed 83.6% concordance for disease confined to the serosa (≤T3): concordance was 97.22% for disease ≤N1 and 33.33% for disease >N1. CONCLUSIONS: MR imaging is critical for discovering T3 disease; moreover, morphological MR imaging does not always provide the opportunity to discern small residual cancer cells hidden in fibrotic tissue that could cause involvement of circumferential resection margin (CRM) on histology.


Assuntos
Quimiorradioterapia , Imageamento por Ressonância Magnética/métodos , Neoplasias Retais/terapia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Capecitabina , Desoxicitidina/administração & dosagem , Desoxicitidina/análogos & derivados , Feminino , Fluoruracila/administração & dosagem , Fluoruracila/análogos & derivados , Humanos , Interpretação de Imagem Assistida por Computador , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Terapia Neoadjuvante , Estadiamento de Neoplasias , Compostos Organoplatínicos/administração & dosagem , Oxaliplatina , Dosagem Radioterapêutica , Radioterapia Conformacional , Neoplasias Retais/patologia , Resultado do Tratamento
12.
Radiol Med ; 117(4): 606-15, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22095427

RESUMO

PURPOSE: This study was done to evaluate the feasibility and safety of radiofrequency ablation (RFA) of renal cell carcinomas (RCCs) in patients with solitary kidney. MATERIALS AND METHODS: Seven patients (two men, five women; age range 52-70 years; mean age 59.7 years) were treated under computed tomography (CT) and ultrasound (US) guidance. Three patients had single lesions, and the remaining four had multiple lesions. Seventeen lesions (4 cortical, 13 exophytic, maximum diameter range 12-40 mm, mean 21.0 mm) not located close to the renal pelvis were treated. CT or magnetic resonance (MR) imaging follow-up studies were obtained for all patients at the end of the procedure and at 1, 3, 6 and 12 months; serum creatinine was also monitored. RESULTS: Ten ablation sessions were performed. In two patients, a perinephric haematoma was detected, and one of these patients had two episodes of self-limiting haematuria. Contrast-enhanced CT and MR imaging at the end of the procedure and at 1 month demonstrated 100% technical success; these results were confirmed at 3, 6 and 12 month. Fisher's test comparing serum creatinine obtained 1 day before and 1 day after the procedure showed no case of acute renal failure (mean serum creatinine 24 h before the procedure 1.02 mg/dl; mean serum creatinine 24 h after the procedure 0.95 mg/dl; p=0.114; not significant). Serum creatinine at follow-up was always within the normal range. CONCLUSIONS: Radiofrequency ablation in the solitary kidney is a safe and effective procedure for treating RCC.


Assuntos
Carcinoma de Células Renais/cirurgia , Ablação por Cateter , Neoplasias Renais/cirurgia , Idoso , Carcinoma de Células Renais/diagnóstico por imagem , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Itália , Testes de Função Renal , Neoplasias Renais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA