Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Bratisl Lek Listy ; 124(3): 170-174, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36598306

RESUMO

INTRODUCTION: Based on a longtime voluntary registry founded by the Ministry of Healthcare of the Slovak Republic in 2012 and endorsed by the National Institute of Cardiovascular Diseases, well-defined data of all adult cardiac surgery procedures performed during the year 2021 are analyzed. MATERIAL AND METHOD: For this period, data on 947 procedures were submitted to the registry. RESULTS: The unadjusted in-hospital survival rate for the 352 isolated coronary artery bypass grafting procedures including urgent and emergency procedures (relationship on-/off pump 3.8 : 1) was 96.3 %. For 331 isolated heart valve procedures (33 transcatheter interventions), it was 95.5 %. Concerning ventricular assist devices, 19 implantations were registered. In 2021 the number of isolated heart transplantations was 16, which is a decrease by 38.5 % as compared to the previous year. CONCLUSION: These annually registered data are collected from voluntary public reporting and accumulate actual information on nearly all heart procedures carried out in the National Institute of Cardiovascular Diseases. These data capture advancements in heart medicine and represent the basis for quality management. In addition, the registry demonstrates that the provision of cardiac surgery in Slovakia is up to date, appropriate, and nationwide patient treatment is guaranteed all the time (Tab. 14, Fig. 2, Ref. 5). Text in PDF www.elis.sk Keywords: heart valve surgery, outcomes, coronary artery bypass grafting, aortic surgery, heart transplantation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doenças Cardiovasculares , Cardiopatias , Humanos , Adulto , Ponte de Artéria Coronária/métodos , Sistema de Registros , Resultado do Tratamento
2.
J Card Surg ; 35(12): 3626-3630, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33029805

RESUMO

The mortality rate after the development of postinfarction ventricular septal defect (VSD) remains high, despite progress in pharmacologic therapy, invasive cardiology, and surgical techniques. We present three cases of preoperative venoarterial extracorporeal membrane oxygenation as a bridge to reparative surgical repair in patients with cardiogenic shock who would otherwise require emergent cardiac surgery with an associated risk. Two patients were discharged, whereas the third patient died due to pulmonary artery rupture after a right ventricular assist device implantation, despite the fact that he had a successful bridge to reparative surgery and VSD repair. Finally, a review of the current literature concerning the use of preoperative venoarterial extracorporeal membrane oxygenation as a bridge to reparative surgery is provided.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Comunicação Interventricular , Coração Auxiliar , Comunicação Interventricular/etiologia , Comunicação Interventricular/cirurgia , Humanos , Masculino , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia
3.
J Card Surg ; 35(8): 2106-2109, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32652731

RESUMO

We report the cases of two patients who developed a massive spasm of the native coronary system in the immediate postoperative period, following a coronary artery bypass grafting operation with different outcomes. The first patient was hemodynamic stable and it was manifested as ischemic electrocardiographic changes in different leads (ST elevation or depression). He was treated with intracoronary and intravenous administration of nitroglycerin and calcium channel blocker and had a favorable outcome. The second patient died due to multiorgan failure and hemorrhagic shock, after the implantation of a central venoarterial extracorporeal membrane oxygenation.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Vasoespasmo Coronário/etiologia , Vasoespasmo Coronário/terapia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Choque Cardiogênico/etiologia , Angiografia Coronária , Vasoespasmo Coronário/diagnóstico por imagem , Vasoespasmo Coronário/fisiopatologia , Evolução Fatal , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Índice de Gravidade de Doença , Resultado do Tratamento
4.
Interact Cardiovasc Thorac Surg ; 27(2): 229-233, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29514222

RESUMO

OBJECTIVES: Primary graft dysfunction (PGD) is a devastating complication and the most common cause of early death following a heart transplant. The goal of this study was to report our experience of using mechanical circulatory support to manage severe PGD. METHODS: Following 208 heart transplants performed between January 2007 and May 2017, 14 (6.7%) patients presented with severe PGD. We provided haemodynamic support using the following approaches: a venoarterial extracorporeal membrane oxygenation device, left ventricular assist device, right ventricular assist device and biventricular assist device. Primary complications included severe PGD, which resulted in hospital deaths and late survival. The mean follow-up was 3.7 ± 2.7 years. RESULTS: Fourteen (6.7%) heart transplant recipients presented with severe PGD. Seven patients received a venoarterial extracorporeal membrane oxygenation device; 1 patient received a left ventricular assist device; 4 patients received a right ventricular assist device; and 2 patients received a biventricular assist device. Mean device support and explantation times were 4.7 ± 2 and 6.3 ± 2 days, respectively. Weaning with cardiac recovery was successful in 57.1% of the patients. The hospital mortality rate was 50%. Postoperative causes of morbidity included renal failure that necessitated dialysis in 28.5%, surgical re-exploration due to postoperative bleeding in 57.1%, pneumonia in 28.5%, sepsis in 14.2%, sternal wound infection in 14.2% and mediastinitis in 7.1% of the patients, respectively. There were no deaths following hospital discharge or later follow-up appointments. CONCLUSIONS: Mechanical support devices such as venoarterial extracorporeal membrane oxygenation specifically offer a reliable therapeutic approach. Recognizing the relatively high number of deaths in-hospital, patients who have cardiac recovery and a successful hospital discharge can expect a favourable late outcome.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Transplante de Coração/efeitos adversos , Coração Auxiliar , Disfunção Primária do Enxerto/cirurgia , Adulto , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória , Disfunção Primária do Enxerto/terapia , Sepse , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA