Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39294917

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is the most common sustained arrhythmia, and catheter ablation (CA) is a primary therapeutic option. However, the 30-day all-cause mortality risk associated with CA for AF may be underestimated due to selection bias. Our study aimed to assess 30-day mortality in an unselected cohort of patients. METHODS: Data from the National Health Fund-Poland covered over 99% of nationwide radiofrequency ablation (RF) or cryoballoon ablation for AF, with 100% recorded deaths. The study included consecutive CA procedures in adult patients between 2012 and 2019. Thirty-day mortality rates were calculated for each age group. RESULTS: A total of 31 214 CAs for AF were performed on 26 767 patients (34.8% female). Forty-four percent of patients had hypertension, 31.2% had coronary artery disease, 14.4% had heart failure, 11% had diabetes mellitus, 5.6% had malignant neoplasms, 2.7% had a previous myocardial infarction, 2.5% had a previous stroke, and 2.2% had kidney disease. Thirty-two deaths (0.1%) occurred within 30 days, with the highest mortality in the oldest age group (>80 years). Statistical analysis revealed higher incidences of kidney disease (p < 0.001) and heart failure (p = 0.001) in patients who died within 30 days. Mortality risk did not significantly differ between cryoballoon and RF ablation, as well as first and subsequent ablation for AF. The risk of death within 7 days postablation for AF was 1 in 2750 procedures, while the risk of death on the same day postablation was 1 in 6250 procedures. CONCLUSIONS: The 30-day mortality rate in a large, unselected AF ablation cohort, covering 99% of procedures in the country, is low except for the oldest patients. This factor should be taken into consideration when offering CA for AF.

3.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
4.
Artigo em Inglês | MEDLINE | ID: mdl-36361063

RESUMO

BACKGROUND: There is limited knowledge on outcome of transvenous lead extraction (TLE) of leads being 20 and 30 years old. METHODS: Retrospective single center large database analysis containing 3673 TLE procedures performed from 2006 to 2020 was analysed. We aimed to compare procedure complexity and the incidence of the TLE major complications (MC) in groups where extracted leads were under 10 years, 10-20 years, 20-30 years (old) and over 30 years (very old). RESULTS: Rate of removal of old and very old leads almost doubles with successive five-year periods (3-6-10%). In patients with old and very old leads there is an accumulation of risk factors for major complications of TLE (young age, female, multiple and/or abandoned leads, multiple previous procedures). The removal of old and very old leads was more labour-consuming, more difficult, and much more often required second-line (advanced) tools and complex techniques. Incidence of all MC grew parallel to age of removed leads from 0.6 to 18.2%; haemopericardium-from 0.3 to 12.1%, severe tricuspid valve damage-from 0.2 to 2.1%, need for rescue cardiac surgery-from 0.4 to 9.1%. Notably, there was no procedure-related death when old or very old lead was extracted. The percentages of clinical and procedural success decreased with increasing age of the removed leads from 99.2 and 97.8% to 90.9 and 81.8%. The risk of MC during extraction of leads aged 10-20 years increases 6.7 times, aged 20-30 years-14.3 times (amounting to 8.4%), and aged 30 and more years-20.4 times, amounting to 18.2%. Removal of ventricular leads is associated with a greater complexity of the procedure but not with more frequent MC. Removal of the atrial leads is associated with a higher incidence of MC, especially haemopericardium, regardless of the age of the leads, although the tendency becomes less pronounced with the oldest leads. CONCLUSIONS: 1. Extraction of old and very old leads is a rising challenge, since the rate of removal of leads aged 20-and-more years almost doubles with successive five-year periods. 2. Procedure difficulty, complexity and the risk of major complications increases along with the age of extracted lead. TLE is more time-consuming, difficult and much more often requires advanced tools and complex techniques. 3. TLE of old (≥20 years) or very old (≥30 years) leads can be performed with satisfactory success rate and safety profile when conducted at high-volume centre by an experienced operator under optimal safety conditions.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Derrame Pericárdico , Humanos , Feminino , Adulto , Adulto Jovem , Remoção de Dispositivo/efeitos adversos , Estudos Retrospectivos , Estudos de Coortes , Derrame Pericárdico/etiologia , Chumbo , Resultado do Tratamento
9.
J Clin Med ; 8(6)2019 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-31208150

RESUMO

Patients with chronic lymphocytic leukemia (CLL) have defects in both humoral and cellular immunity as a result of their underlying malignancy, as well as chemotherapy-related immune suppression. Upper respiratory tract (URT) colonization can be regarded as a major contributor to infection, so the relationship between carriage rates, disease incidence, or antibiotic resistance should be monitored. This prospective study included 50 newly diagnosed, previously untreated patients with CLL and 38 healthy volunteers. A total of 264 samples obtained from anterior nares and oropharynx were microbiologically examined. A significantly higher frequency of S. aureus and Gram-negative bacilli (GNB) colonization in CLL patients was observed in comparison to healthy volunteers. Information regarding baseline characteristics; the Rai staging system; hematological tests results; immunophenotype of basic lymphocyte subsets, including the expression of programmed cell death-1 protein (PD-1) and its ligand (PD-L1); as well as Epstein-Barr virus (EBV) status were determined to analyze risk factors for infections and bacterial colonization. The data represent the basic information for identification of further risk factors of infection and bacterial oropharyngeal colonization in CLL patients. The rate of disease progression within the time from the CLL diagnosis was significantly higher in patients colonized by GNB. This study highlights EBV infection and frequencies of PD-1 positive T CD3+ cells and B cells as risk factors in CLL patients.

10.
J Cardiovasc Electrophysiol ; 30(7): 1005-1012, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30938917

RESUMO

INTRODUCTION: Repeated procedures are often needed for long-term success of atrial fibrillation ablation. There are scarce data regarding cryoballoon use for such procedure. METHODS AND RESULTS: We analyzed acute effect and long-term follow-up of second-generation cryoballoon ablation, performed as a repeat procedure after an index radiofrequency vs cryoballoon ablation. Sixty-one patients from three centers were included. In 36 cases radiofrequency (RF-I) and in 25 cryoballoon ablation (CB-I) was the index procedure. During redo procedure, pulmonary vein reconnection was less frequent in CB-I vs RF-I (51.5% vs 66.9%; P = 0.017). After cryoballoon, left inferior (P = 0.027) and right superior (P = 0.06) pulmonary veins were less likely to exhibit reconnection. Moreover, patients after initial RF ablation frequently presented multiple-vein reconnection (P = 0.018), while patients after cryoablation more often had only one vein reconnected (P = 0.008). During reablation procedures, all 149 reconnected veins in both groups were isolated, with no differences in procedural parameters, except for procedure time, shorter in CB-I group (65.5 vs 71.1 minutes; P = 0.04). Transient phrenic nerve palsy was the only complication in both groups (5.6% and 8.0%; ns). After mean follow-up of 15 ± 9 months, 70.3% of patients were free from atrial fibrillation (AF), with no differences between the groups (P = 0.71). In multivariate Cox-regression analysis, the persistent form of arrhythmia (P = 0.009) and relapse in the blanking period (P = 0.0004) were the only independent predictors of AF recurrence. CONCLUSIONS: The use of second-generation cryoballoon is associated with less frequent pulmonary vein reconnection compared with RF ablation. Cryoballoon is safe and effective for repeated AF ablation, regardless of the technique used for the initial procedure.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Polônia , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
11.
Epilepsia ; 52(11): 2118-24, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21933183

RESUMO

PURPOSE: There has been growing interest in cardiac disturbances in epilepsy patients and their etiologic role in the context of sudden death. Ventricular late potentials (VLPs) recorded on signal-averaged electrocardiography (SAECG) reflects delayed ventricular depolarization and identifies the structural or functional substrate for the ventricular tachycardia in the reentry mechanism. Therefore, abnormal SAECG poses the potential of identifying patients at increased risk of malignant ventricular arrhythmias and sudden cardiac death. The aim of this exploratory study was to screen epilepsy patients who were treated with established doses of antiepileptic drugs (AEDs) on the presence of VLPs. METHODS: Forty-five consecutive patients with the diagnosis of epilepsy and 19 healthy volunteers, aged younger than 46 years, participated in the study. Exclusion criteria included symptoms or signs of diseases other than epilepsy, in particular relating to heart disease or medication influencing the cardiovascular system, as well as seizure reported by patients that occurred <3 days before the ECG examination. The electrocardiogram was recorded according to the standard protocol. The seizure frequency was calculated based on the available data of epileptic events within the preceding 3 months. Disease duration was estimated by determining the time from the first reported seizure to the present. KEY FINDINGS: There were 22 patients (48%) in the epilepsy group and only one patient (5%) in the control group fulfilling the criteria for VLP (p = 0.0005). Subsequently, epilepsy patients were divided into two subgroups according to VLP presence. Patients with VLP had longer disease duration (p = 0.03) compared to those without VLP. Similarly, patients with VLP more frequently had refractory epilepsy (p = 0.03) and had higher monthly seizure frequency (p = 0.02). Analysis of the proportions of generalized seizures (GS) and focal seizures (FS) showed a tendency for higher number of generalized tonic-clonic seizures in the VLP group, but this did not reach statistical significance (p = 0.06). VLP patients tended to be more often on polytherapy (defined as more than one AED per patient) (p = 0.07) as compared to epilepsy patients without VLP. However, if the numbers of AEDs per patients among the subgroups were compared, patients with VLP were treated with more AEDs than patients without VLP (p = 0.01). The study was not sufficiently powered to pinpoint any particular drug or AED combination to influence the appearance of VLP in epileptic patients. In particular, there was no difference in valproate or carbamazepine exposure, considering the percentage of patients exposed or the total daily dose administered. SIGNIFICANCE: Epilepsy patients more frequently display abnormal SAECGs with VLPs as compared to the control population, and their presence correlates with the disease duration, uncontrolled seizures, and polytherapy. Further longitudinal studies are needed in order to stratify the risk of life-threatening ventricular events in epilepsy patients with VLPs.


Assuntos
Arritmias Cardíacas/etiologia , Epilepsia/complicações , Adulto , Arritmias Cardíacas/fisiopatologia , Estudos de Casos e Controles , Ecocardiografia , Eletrocardiografia , Epilepsia/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Convulsões/complicações , Convulsões/fisiopatologia , Estatísticas não Paramétricas , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Função Ventricular/fisiologia , Adulto Jovem
12.
Kardiol Pol ; 67(1): 95-100, 2009 Jan.
Artigo em Polonês | MEDLINE | ID: mdl-19253199

RESUMO

We describe a case of persistent atrial tachycardia/flutter in a 19-year old female with corrected transposition of great arteries (ccTGA) and dual inlet left ventricle (DILV), treated with surgical palliative operations. The arrhythmia became persistent and symptomatic with dyspnea and severe cyanosis. During the EP study, the right atrial isthmus-dependent reentry was identified. In electroanatomical maps large areas of low voltage and electrical silence were localised. Due to these areas of slow conduction the isthmus dependent arrhythmia had long CL. Linear RF applications closed the isthmus, resulting in flutter termination. During 3 months of follow-up the patient remained free of arrhythmia.


Assuntos
Fibrilação Atrial/etiologia , Flutter Atrial/etiologia , Mapeamento Potencial de Superfície Corporal/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ablação por Cateter/métodos , Cardiopatias Congênitas/cirurgia , Cuidados Paliativos , Fibrilação Atrial/terapia , Flutter Atrial/terapia , Diagnóstico por Computador/métodos , Feminino , Cardiopatias Congênitas/complicações , Humanos , Resultado do Tratamento , Adulto Jovem
13.
Przegl Lek ; 62(7): 653-6, 2005.
Artigo em Polonês | MEDLINE | ID: mdl-16463695

RESUMO

The aim of the present study was to estimate the influence of hemodialysis process (HD) on the signal-averaged ECG (SAECG) parameters and to evaluate possible factors promoting SAECG parameters disturbances in the group of hemodialysis patients (HD-pts). 55 selected HD-pts entered the study. SAECG parameters (QRS duration, root-mean-square of the terminal 40 ms of the QRS--RMS40, low-amplitude signal duration--LAS40), were measured pre and postdialysis. Total (TBW), extracellular (ECW) and intracellular body water (ICW) calculated per kg of HD-pts body weight were estimated pre and postdialysis by using whole body bioimpedance. Two dimentional echocardiography was performed before HD. Serum levels of interleukin-6 (IL-6), tumor necrosis factor-alpha, CRP and intact parathormon were measured before HD. LP were found only before HD in 12.73% of patients. HD induced the decrease of LAS40 duration and the increase of RMS40 value in the of group of LP positive HD-pts (p<0.001 in both cases). The values of TBW and ECW calculated per kg of body weight as well as IL-6 and CRP levels were significantly higher in the LP positive in comparison with the LP negative patients (p=0.006 and 0.004 respectively). Induced by HD changes of RMS40 correlated with pre vs postdialysis values of TBW (r=0.499, p=0.001) and ECW (r=0.556, p<0.001) calculated per kg of body weight. Our study revealed that, that abnormal SAECG parameters and LP are frequently detected in HD-pts. The presence of LP in HD-pts in great part depends on the functional abnormalities (especially on the HD-pts hydration status) corrected by the HD process. The clinical significance of the proinflammatory factors (IL-6 and CRP) needs further investigation.


Assuntos
Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Diálise Renal/efeitos adversos , Processamento de Sinais Assistido por Computador , Adulto , Circulação Coronária , Ecocardiografia , Feminino , Frequência Cardíaca , Humanos , Interleucina-6/sangue , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Fator de Necrose Tumoral alfa/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA