Phys Med ; 32(5): 681-90, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27160829

RESUMO

PURPOSE: Within the SYRMA-CT collaboration based at the ELETTRA synchrotron radiation (SR) facility the authors investigated the imaging performance of the phase-contrast computed tomography (CT) system dedicated to monochromatic in vivo 3D imaging of the female breast, for breast cancer diagnosis. METHODS: Test objects were imaged at 38keV using monochromatic SR and a high-resolution CdTe photon-counting detector. Signal and noise performance were evaluated using modulation transfer function (MTF) and noise power spectrum. The analysis was performed on the images obtained with the application of a phase retrieval algorithm as well as on those obtained without phase retrieval. The contrast to noise ratio (CNR) and the capability of detecting test microcalcification clusters and soft masses were investigated. RESULTS: For a voxel size of (60µm)(3), images without phase retrieval showed higher spatial resolution (6.7mm(-1) at 10% MTF) than corresponding images with phase retrieval (2.5mm(-1)). Phase retrieval produced a reduction of the noise level and an increase of the CNR by more than one order of magnitude, compared to raw phase-contrast images. Microcalcifications with a diameter down to 130µm could be detected in both types of images. CONCLUSIONS: The investigation on test objects indicates that breast CT with a monochromatic SR source is technically feasible in terms of spatial resolution, image noise and contrast, for in vivo 3D imaging with a dose comparable to that of two-view mammography. Images obtained with the phase retrieval algorithm showed the best performance in the trade-off between spatial resolution and image noise.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Compostos de Cádmio/química , Mamografia/métodos , Síncrotrons , Telúrio/química , Tomografia Computadorizada por Raios X , Algoritmos , Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Meios de Contraste/química , Desenho de Equipamento , Feminino , Humanos , Microscopia de Contraste de Fase , Fótons , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído
2.
Phys Med Biol ; 61(4): 1634-49, 2016 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-26836274

RESUMO

The aim of the SYRMA-CT collaboration is to set-up the first clinical trial of phase-contrast breast CT with synchrotron radiation (SR). In order to combine high image quality and low delivered dose a number of innovative elements are merged: a CdTe single photon counting detector, state-of-the-art CT reconstruction and phase retrieval algorithms. To facilitate an accurate exam optimization, a Monte Carlo model was developed for dose calculation using GEANT4. In this study, high isotropic spatial resolution (120 µm)(3) CT scans of objects with dimensions and attenuation similar to a human breast were acquired, delivering mean glandular doses in the range of those delivered in clinical breast CT (5-25 mGy). Due to the spatial coherence of the SR beam and the long distance between sample and detector, the images contain, not only absorption, but also phase information from the samples. The application of a phase-retrieval procedure increases the contrast-to-noise ratio of the tomographic images, while the contrast remains almost constant. After applying the simultaneous algebraic reconstruction technique to low-dose phase-retrieved data sets (about 5 mGy) with a reduced number of projections, the spatial resolution was found to be equal to filtered back projection utilizing a four fold higher dose, while the contrast-to-noise ratio was reduced by 30%. These first results indicate the feasibility of clinical breast CT with SR.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Humanos , Tomografia Computadorizada por Raios X/métodos
3.
Med Phys ; 36(11): 5149-61, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19994525

RESUMO

Thomson scattering x-ray sources can provide spectral distributions that are ideally suited for mammography with sufficient fluence rates. In this article, the authors investigate the effects of different spectral distributions on the image quality in simulated images of a breast mammographic phantom containing details of different compositions and thicknesses. They simulated monochromatic, quasimonochromatic, and polychromatic x-ray sources in order to define the energy for maximum figure of merit (signal-difference-to-noise ratio squared/mean glandular dose), the effect of an energy spread, and the effect of the presence of higher-order harmonics. The advantages of these sources with respect to conventional polychromatic sources as a function of phantom and detail thickness were also investigated. The results show that the energy for the figure of merit peak is between 16 and 27.4 keV, depending on the phantom thickness and detail composition and thickness. An energy spread of about 1 keV standard deviation, easily achievable with compact x-ray sources, does not appreciably affect the image quality.


Assuntos
Simulação por Computador , Mamografia/instrumentação , Mamografia/métodos , Método de Monte Carlo , Espalhamento de Radiação , Raios X , Algoritmos , Calcinose/diagnóstico por imagem , Feminino , Humanos , Modelos Biológicos , Imagens de Fantasmas , Fótons , Doses de Radiação , Filme para Raios X
4.
Comput Biol Med ; 39(12): 1137-44, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19883906

RESUMO

A completely automated system for the identification of pleural nodules in low-dose and thin-slice computed tomography (CT) of the lung has been developed. The directional-gradient concentration method has been applied to the pleura surface and combined with a morphological opening-based procedure to generate a list of nodule candidates. Each nodule candidate is characterized by 12 morphological and textural features, which are analyzed by a rule-based filter and a neural classifier. This detection system has been developed and validated on a dataset of 42 annotated CT scans. The k-fold cross validation has been used to evaluate the neural classifier performance. The system performance variability due to different ground truth agreement levels is discussed. In particular, the poor 44% sensitivity obtained on the ground truth with agreement level 1 (nodules annotated by only one radiologist) with six FP per scan grows up to the 72% if the underlying ground truth is changed to the agreement level 2 (nodules annotated by two radiologists).


Assuntos
Diagnóstico por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Bases de Dados Factuais , Diagnóstico por Computador/estatística & dados numéricos , Reações Falso-Positivas , Humanos , Imageamento Tridimensional , Reconhecimento Automatizado de Padrão , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
5.
Med Phys ; 33(9): 3469-77, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17022243

RESUMO

We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detector allowed its use with a larger pinhole collimator than could be used with the CZT detector. Additionally, the improved pinhole collimator and alignment features of the apparatus permitted much more rapid setup for acquisition of x-ray spectra than was possible on the system described in the earlier work. These improvements in detector technology, collimation and ease of alignment, as well as low cost, make this apparatus attractive as a tool for both laboratory research and advanced mammography quality control.


Assuntos
Análise de Falha de Equipamento/instrumentação , Mamografia/instrumentação , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/instrumentação , Espectrometria por Raios X/instrumentação , Calibragem , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Miniaturização , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria por Raios X/métodos
6.
Radiat Prot Dosimetry ; 114(1-3): 350-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15933135

RESUMO

A simulator for X-ray images is presented based on a virtual X-ray source and a virtual human body obtained from tomographic slices. In the simulator it is possible to modify the tube potential, the anodic current, the exposure time, the filtration and some geometric parameters such as source-skin distance, orientation and field size. The virtual body consists of a three-dimensional voxel matrix in which CT numbers for each point of the body are stored. The interactions of X rays passing through the body are evaluated using the pencil beam technique. The image is obtained by computing the dose absorbed by the detector and converting it into optical density using a proper response function. The image spatial resolution is limited by the voxel size. The influence of each parameter on the image quality can be observed interactively. The dose absorbed in each point of the body is an important parameter obtained as output of the simulator.


Assuntos
Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Raios X , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Modelos Anatômicos , Modelos Estatísticos , Método de Monte Carlo , Doses de Radiação , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador , Planejamento da Radioterapia Assistida por Computador , Tomógrafos Computadorizados
7.
Med Phys ; 31(10): 2763-70, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15543781

RESUMO

In routine applications, information about the photon flux of x-ray tubes is obtained from exposure measurements and cataloged spectra. This approach relies mainly on the assumption that the real spectrum is correctly approximated by the cataloged one, once the main characteristics of the tube such as voltage, target material, anode angle, and filters are taken account of. In practice, all this information is not always available. Moreover, x-ray tubes with the same characteristics may have different spectra. We describe an apparatus that should be useful for quality control in hospitals and for characterizing new radiographic systems. The apparatus analyzes the spectrum generated by an x-ray mammographic unit. It is based on a commercial CZT produced by AMPTEK Inc. and a set of tungsten collimator disks. The electronics of the CZT are modified so as to obtain a faster response. The signal is digitized using an analog to digital converter with a sampling frequency of up to 20 MHz. The whole signal produced by the x-ray tube is acquired and analyzed off-line in order to accurately recognize pile-up events and reconstruct the emitted spectrum. The energy resolution has been determined using a calibrated x-ray source. Spectra were validated by comparison of the HVL measured using an ionization chamber.


Assuntos
Algoritmos , Análise de Falha de Equipamento/instrumentação , Mamografia/instrumentação , Molibdênio/química , Molibdênio/efeitos da radiação , Radiometria/instrumentação , Raios X , Desenho de Equipamento , Miniaturização , Garantia da Qualidade dos Cuidados de Saúde/métodos , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador