RESUMO
BACKGROUND: In this study we investigated the impact of ABC stroke score on the recurrence of paroxysmal atrial fibrillation (PAF) following radiofrequency catheter ablation (RFCA). METHODS: A total of 132 patients with PAF who underwent RFCA from October 2018 to September 2019 were included in this study. During the first phase of this study the patients were categorized into two groups based on late recurrence of atrial fibrillation after RFCA. In the second phase, the patients were further divided into two groups based on whether their ABC stroke score was ≥ 6.5. RESULT: The univariate analysis indicated that the risk factors for late recurrence of PAF included early recurrence, ABC stroke score, CHA2DS2-VASc score, and NT-proBNP (P < 0.05). Cox multivariate regression analysis revealed that ABC stroke score (P = 0.006) and early recurrence (P = 0.000) were independent predictors of late recurrence, and ABC stroke score ≥ 6.5 was a risk for predicting recurrence of PAF after RFCA with a sensitivity of 66.7% and specificity of 65.7%. After the completion of the 1:1 matching, the univariate Cox analysis indicated that an elevated score of ABC stroke (≥ 6.5) was an independent predictor of late recurrence of PAF (HR = 2.687, 95% CI: 1.036-6.971, P = 0.042). However, using an ABC stroke score cut off at 6.4 predicted the recurrence of atrial tachyarrhythmia with 85% sensitivity and 58.5% specificity. CONCLUSION: An ABC stroke score ≥ 6.4 is a predictor for late recurrence of PAF after RFCA.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Recidiva , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Acidente Vascular Cerebral/etiologia , Fatores de Risco , Estudos Retrospectivos , Idoso , Medição de Risco/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologiaRESUMO
We compared the efficacy and complication rates of quantitative radiofrequency ablation guided by ablation index (RFCA-AI) with those of second-generation cryoballoon ablation (CBA-2). Consecutive patients (n = 230) with symptomatic atrial fibrillation (AF) undergoing a first ablation CBA-2 (92 patients) or RFCA-AI (138 patients) procedure were enrolled in this study. The late recurrence rate in the CBA-2 group was higher than that in the RFCA-AI group (P = .012). Subgroup analysis showed the same result in patients with paroxysmal AF (PAF) (P = .039), but no difference was found in patients with persistent AF (P = .21). The average operation duration in the CBA-2 group (85 [75-99.5] minutes) was shorter than that in the RFCA-AI group (100 [84.5-120] minutes) (P < .0001), but the average exposure time (17.36(13.87-22.49) vs 5.49(4.00-8.24) minutes) in the CBA-2 group and X-ray dose (223.25(149.15-336.95) vs 109.15(80.75-168.7) mGym) were significantly longer than those in RFCA-AI group (P < .0001). Multivariate logistic regression analysis showed that left atrial diameter (LAD), early recurrence, and methods of ablation (cryoballoon ablation) were independent risk factors for late recurrence after AF ablation. Early recurrence of AF and LAD were independent risk factors for predicting late recurrence after AF ablation.