Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pediatr Radiol ; 53(9): 1911-1918, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37171639

RESUMO

BACKGROUND: One of the main limitations of 99mtechnetium-dimercaptosuccinic acid (DMSA) scan is the long acquisition time. OBJECTIVE: To evaluate the feasibility of short DMSA scan acquisition times using a cadmium-zinc-telluride-based single-photon emission computed tomography (SPECT) system in children. MATERIALS AND METHODS: The data of 27 children (median age: 4 years; 16 girls) who underwent DMSA SPECT were retrospectively analyzed. Both planar and SPECT DMSA were performed. SPECT images were analyzed using coronal-simulated planar two-dimensional images. A reduction in SPECT acquisition time was simulated to provide 4 series (SPECT-15 min, SPECT-10 min, SPECT-5 min and SPECT-2.5 min). A direct comparison of the planar and SPECT series was performed, including semi-quantification reproducibility, image quality (mean quality score on a scale of 0 to 2) and inter- and intra-observer reproducibility of the scintigraphic patterns. RESULTS: The overall image quality score (± standard deviation) was 1.3 (± 0.6) for the planar data set, 1.6 (± 0.5) for the SPECT-15 min data set, 1.4 (± 0.5) for the SPECT-10 min data set, 1.0 (± 0.5) for the SPECT-5 min data set and 0.6 (± 0.6) for the SPECT-2.5 min data set. Median Kappa coefficients for inter-observer agreement between planar and SPECT images were greater than 0.83 for all series and all readers except one reader for the SPECT-2.5 min series (median Kappa coefficient = 0.77). CONCLUSION: Shortening SPECT acquisitions to 5 min is feasible with minimal impact on images in terms of quality and reproducibility.


Assuntos
Ácido Dimercaptossuccínico Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Criança , Feminino , Humanos , Pré-Escolar , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
Clin Infect Dis ; 73(3): 393-403, 2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-32488236

RESUMO

BACKGROUND: Diagnostic and patients' management modifications induced by whole-body 18F-FDG-PET/CT had not been evaluated so far in prosthetic valve (PV) or native valve (NV) infective endocarditis (IE)-suspected patients. METHODS: In sum, 140 consecutive patients in 8 tertiary care hospitals underwent 18F-FDG-PET/CT. ESC-2015-modified Duke criteria and patients' management plan were established jointly by 2 experts before 18F-FDG-PET/CT. The same experts reestablished Duke classification and patients' management plan immediately after qualitative interpretation of 18F-FDG-PET/CT. A 6-month final Duke classification was established. RESULTS: Among the 70 PV and 70 NV patients, 34 and 46 were classified as definite IE before 18F-FDG-PET/CT. Abnormal perivalvular 18F-FDG uptake was recorded in 67.2% PV and 24.3% NV patients respectively (P < .001) and extracardiac uptake in 44.3% PV and 51.4% NV patients. IE classification was modified in 24.3% and 5.7% patients (P = .005) (net reclassification index 20% and 4.3%). Patients' managements were modified in 21.4% PV and 31.4% NV patients (P = .25). It was mainly due to perivalvular uptake in PV patients and to extra-cardiac uptake in NV patients and consisted in surgery plan modifications in 7 patients, antibiotic plan modifications in 22 patients and both in 5 patients. Altogether, 18F-FDG-PET/CT modified classification and/or care in 40% of the patients (95% confidence interval: 32-48), which was most likely to occur in those with a noncontributing echocardiography (P < .001) or IE classified as possible at baseline (P = .04), while there was no difference between NV and PV. CONCLUSIONS: Systematic 18F-FDG-PET/CT did significantly and appropriately impact diagnostic classification and/or IE management in PV and NV-IE suspected patients. CLINICAL TRIALS REGISTRATION: NCT02287792.


Assuntos
Endocardite , Próteses Valvulares Cardíacas , Endocardite/diagnóstico por imagem , Fluordesoxiglucose F18 , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Compostos Radiofarmacêuticos
3.
Clin Nucl Med ; 43(6): 389-395, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29561524

RESUMO

PURPOSE: The aim of this study was to determine the minimum acquisition time without decreasing lesion detectability of bone SPECT using a whole-body cadmium-zinc-telluride camera. METHODS: Patients referred for bone SPECT were retrospectively included. SPECT of 30 patients were reframed from native data (16 s/projection) to produce 10-, 5-, and 3-s/projection data sets. A "critical" acquisition time/projection was defined as that below which the SPECT quality becomes insufficient for interpretation, as determined by 3 reviewers using a 4-point scale (0 = quality insufficient for interpretation, 1 = average, 2 = good, 3 = excellent). Three reviewers (blinded to the acquisition time) evaluated SPECT data sets (n = 79), native and reframed with "critical" acquisition times, in a randomized order. A lesion was defined as any uptake considered pathological by a reviewer. Lesion detectability equivalence between native SPECT and reframed SPECT was assessed by calculating a coefficient (κ) for each reviewer. RESULTS: Image quality of the first sample (n = 30) was significantly and progressively less well graded for the reframed data sets by all reviewers. Only 1 patient was graded 0 by each reviewer for the 5-s/projection data set. For the 3-s/projection data set, 3 patients were graded 0. No patients were graded 0 for 10-s/projection data set. The minimal acquisition time, for each projection, was defined as 5 s/projection. The coefficient κ, between native and reframed, with critical acquisition time/projection SPECT was greater than 0.9 for each reviewer. CONCLUSIONS: The more contrasted images of the cadmium-zinc-telluride camera allow performance of 5-s/projection SPECT without loss of lesion detectability. This suggests the possibility of performing whole-body SPECT in a reasonable time or reducing injected doses, especially in pediatric patients.


Assuntos
Osso e Ossos/diagnóstico por imagem , Câmaras gama/normas , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adolescente , Cádmio , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/instrumentação , Sensibilidade e Especificidade , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA