Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ophthalmologe ; 116(8): 789-793, 2019 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-30426193

RESUMO

A 53-year-old patient consulted our practice clinic complaining of progressive visual loss, increased glare sensitivity and color sense disorder. Extensive diagnostic investigation, including multifocal ERG (mfERG) and macular thickness map with the help of optical coherence tomography (OCT), supported the suspected diagnosis of a cone dystrophy. There are, however, no established therapeutic options. A diagnostic confirmation by means of molecular genetics was not successful.


Assuntos
Distrofia de Cones , Tomografia de Coerência Óptica , Distrofia de Cones/diagnóstico , Eletrorretinografia , Angiofluoresceinografia , Humanos , Pessoa de Meia-Idade , Regulador Transcricional ERG , Transtornos da Visão
2.
Klin Monbl Augenheilkd ; 221(1): 56-8, 2004 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-14745681

RESUMO

BACKGROUND: Several early and late complications have been described since the introduction of cerclage surgery using a supramid suture. Due to cutting of the supramid suture through scleral tissue the supramid suture may appear at the fundus. Long-term results of scleral penetration and crossing the bulbus by the supramid suture, which is then only covered by the retina ("clothesline phenomenon"), could not be described so far. We report on a patient 20 years after cerclage surgery with Arruga's suture. CASE REPORT: A now 63-year old female patient with high myopia (D - 14.0 OU) suffering from complete retinal detachment had had ophthalmic surgery using Arruga's encircling suture with additional horizontal buckling at her left eye in 1983. Postoperative visual acuity was 10/20. The retina was attached. In 2002 phakoemulsification with posterior chamber lens implantation due to cataracta corticalis was done externally. In 2003 a complete scleral and chorioidal penetration and appearance of the Arruga's suture behind the retina occurred extending from 4 over 6 to 8 o'clock position with a visual acuity of 20/25. The patient did not agree with the cutting of the suture at any time. CONCLUSIONS: The "clothesline phenomenon" is a very rare late complication after encircling surgery using an Arruga suture by retinal detachment. Suture cutting is suggested because of a possible risk of retinal detachment. As shown in our case report, stable retinal attachment after Arruga's suturing is possible.


Assuntos
Migração de Corpo Estranho/cirurgia , Miopia/cirurgia , Complicações Pós-Operatórias/cirurgia , Retina , Descolamento Retiniano/cirurgia , Esclera , Recurvamento da Esclera , Técnicas de Sutura/efeitos adversos , Suturas , Feminino , Migração de Corpo Estranho/diagnóstico , Humanos , Lentes Intraoculares , Pessoa de Meia-Idade , Oftalmoscopia , Retina/cirurgia , Descolamento Retiniano/diagnóstico , Esclera/cirurgia , Recusa do Paciente ao Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA