Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Lasers Surg Med ; 55(4): 405-413, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36924183

RESUMO

OBJECTIVES: Reflectance confocal microscopy (RCM) is an imaging method that can noninvasively visualize microscopic features of the human skin. The utility of RCM can be further improved by increasing imaging speed. In this paper, we report high-speed RCM imaging of human skin with a frame rate that is over 10 times faster and an area imaging rate that is 6-9 times faster than those of commercially available RCM devices. METHODS: The higher imaging speed was achieved using a high-speed RCM technique, termed spectrally encoded confocal microscopy (SECM). SECM uses a diffraction grating and a high-speed, wavelength-swept source to conduct confocal imaging at a very high rate. We developed a handheld SECM probe using a scanned-grating approach. The SECM probe was used in conjunction with a wavelength-swept source with a spectral band of 1251-1342 nm. RESULTS: The SECM probe achieved high lateral resolution of 1.3-1.6 µm and an axial resolution of 3.5 µm. SECM images of the human skin (image size = 439 × 439 µm2 ) obtained at 100 frames/s clearly show previously reported RCM features of the human skin in vivo with adequate image quality. The fast imaging speed allowed for the rapid acquisiton of volumetric SECM image data (200 frames covering a depth range of 200 µm) within 2 s. The use of 1251-1342 nm provided sufficient signal level and contrast required to visualize key cellular morphologic features. CONCLUSIONS: These preliminary results demonstrate that high-speed SECM imaging of the human skin at 1251-1342 nm is feasible.


Assuntos
Pele , Humanos , Microscopia Confocal/métodos
2.
Lasers Surg Med ; 54(7): 935-944, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35708124

RESUMO

BACKGROUND/OBJECTIVES: Optical coherence tomography (OCT) uses low coherence interferometry to obtain depth-resolved tissue reflectivity profiles (M-mode) and transverse beam scanning to create images of two-dimensional tissue morphology (B-mode). Endoscopic OCT imaging probes typically employ proximal or distal mechanical beam scanning mechanisms that increase cost, complexity, and size. Here, we demonstrate in the gastrointestinal (GI) tracts of unsedated human patients, that a passive, single-fiber probe can be used to guide device placement, conduct device-tissue physical contact sensing, and obtain two-dimensional OCT images via M-to-B-mode conversion. MATERIALS AND METHODS: We designed and developed ultrasmall, manually scannable, side- and forward-viewing single fiber-optic probes that can capture M-mode OCT data. Side-viewing M-mode OCT probes were incorporated into brush biopsy devices designed to harvest the microbiome and forward-viewing M-mode OCT probes were integrated into devices that measure intestinal potential difference (IPD). The M-mode OCT probe-coupled devices were utilized in the GI tract in six unsedated patients in vivo. M-mode data were converted into B-mode images using an M-to-B-mode conversion algorithm. The effectiveness of physical contact sensing by the M-mode OCT probes was assessed by comparing the variances of the IPD values when the probe was in physical contact with the tissue versus when it was not. The capacity of forward- and side-viewing M-mode OCT probes to produce high-quality B-mode images was compared by computing the percentages of the M-to-B-mode images that showed close contact between the probe and the luminal surface. Passively scanned M-to-B-mode images were qualitatively compared to B-mode images obtained by mechanical scanning OCT tethered capsule endomicroscopy (TCE) imaging devices. RESULTS: The incorporation of M-mode OCT probes in these nonendoscopic GI devices safely and effectively enabled M-mode OCT imaging, facilitating real-time device placement guidance and contact sensing in vivo. Results showed that M-mode OCT contact sensing improved the variance of IPD measurements threefold and side-viewing probes increased M-to-B-mode image visibility by 10%. Images of the esophagus, stomach, and duodenum generated by the passively scanned probes and M-to-B-mode conversion were qualitatively superior to B-mode images obtained by mechanically scanning OCT TCE devices. CONCLUSION: These results show that passive, single optical fiber OCT probes can be effectively utilized for nonendoscopic device placement guidance, device contact sensing, and two-dimensional morphologic imaging in the human GI tract in vivo. Due to their small size, lower cost, and reduced complexity, these M-mode OCT probes may provide an easier avenue for the incorporation of OCT functionality into endoscopic/nonendoscopic devices.


Assuntos
Tecnologia de Fibra Óptica , Tomografia de Coerência Óptica , Biópsia , Endoscópios , Endoscopia , Humanos
3.
Clin Gastroenterol Hepatol ; 20(4): 756-765.e3, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33549871

RESUMO

BACKGROUND & AIMS: Tethered capsule endomicroscopy (TCE) involves swallowing a small tethered pill that implements optical coherence tomography (OCT) imaging, procuring high resolution images of the whole esophagus. Here, we demonstrate and evaluate the feasibility and safety of TCE and a portable OCT imaging system in patients with Barrett's esophagus (BE) in a multi-center (5-site) clinical study. METHODS: Untreated patients with BE as per endoscopic biopsy diagnosis were eligible to participate in the study. TCE procedures were performed in unsedated patients by either doctors or nurses. After the capsule was swallowed, the device continuously obtained 10-µm-resolution cross-sectional images as it traversed the esophagus. Following imaging, the device was withdrawn through mouth, and disinfected for subsequent reuse. BE lengths were compared to endoscopy findings when available. OCT-TCE images were compared to volumetric laser endomicroscopy (VLE) images from a patient who had undergone VLE on the same day as TCE. RESULTS: 147 patients with BE were enrolled across all sites. 116 swallowed the capsule (79%), 95/114 (83.3%) men and 21/33 (63.6%) women (P = .01). High-quality OCT images were obtained in 104/111 swallowers (93.7%) who completed the procedure. The average imaging duration was 5.55 ± 1.92 minutes. The mean length of esophagus imaged per patient was 21.69 ± 5.90 cm. A blinded comparison of maximum extent of BE measured by OCT-TCE and EGD showed a strong correlation (r = 0.77-0.79). OCT-TCE images were of similar quality to those obtained by OCT-VLE. CONCLUSIONS: The capabilities of TCE to be used across multiple sites, be administered to unsedated patients by either physicians or nurses who are not expert in OCT-TCE, and to rapidly and safely evaluate the microscopic structure of the esophagus make it an emerging tool for screening and surveillance of BE patients. Clinical trial registry website and trial number: NCT02994693 and NCT03459339.


Assuntos
Esôfago de Barrett , Neoplasias Esofágicas , Esôfago de Barrett/diagnóstico por imagem , Esôfago de Barrett/patologia , Biópsia , Neoplasias Esofágicas/patologia , Esofagoscopia/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia de Coerência Óptica/métodos
4.
Lasers Surg Med ; 51(5): 452-458, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30614021

RESUMO

BACKGROUND AND OBJECTIVE: The tethered spectrally-encoded confocal endomicroscopy (SECM) capsule is an imaging device that once swallowed by an unsedated patient can visualize cellular morphologic changes associated with gastrointestinal (GI) tract diseases in vivo. Recently, we demonstrated a tethered SECM capsule for counting esophageal eosinophils in patients with eosinophilic esophagitis (EoE) in vivo. Yet, the current tethered SECM capsule is far too long to be widely utilized for imaging pediatric patients, who constitute a major portion of the EoE patient population. In this paper, we present a new tethered SECM capsule that is 33% shorter, has an easier and repeatable fabrication process, and produces images with reduced speckle noise. MATERIALS AND METHODS: The smaller SECM capsule utilized a miniature condenser to increase the fiber numerical aperture and reduce the capsule length. A custom 3D-printed holder was developed to enable easy and repeatable device fabrication. A dual-clad fiber (DCF) was used to reduce speckle noise. RESULTS: The fabricated SECM capsule (length = 20 mm; diameter = 7 mm) had a similar size and shape to a pediatric dietary supplement pill. The new capsule achieved optical sectioning thickness of 13.2 µm with a small performance variation between devices of 1.7 µm. Confocal images of human esophagus obtained in vivo showed the capability of this new device to clearly resolve microstructural epithelial details with reduced speckle noise. CONCLUSIONS: We expect that the smaller size and better image performance of this new SECM capsule will greatly facilitate the clinical adoption of this technology in pediatric patients and will enable more accurate assessment of EoE-suspected tissues. Lasers Surg. Med. 51:452-458, 2019. © 2019 Wiley Periodicals, Inc.

5.
Sci Rep ; 8(1): 2631, 2018 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-29422678

RESUMO

Esophagogastroduodenoscopy (EGD) is a widely used procedure, posing significant financial burden on both healthcare systems and patients. Moreover, EGD is time consuming, sometimes difficult to tolerate, and suffers from an imperfect diagnostic yield as the limited number of collected biopsies does not represent the whole organ. In this paper, we report on technological and clinical feasibility of a swallowable tethered endomicroscopy capsule, which is administered without sedation, to image large regions of esophageal and gastric mucosa at the cellular level. To demonstrate imaging capabilities, we conducted a human pilot study (n = 17) on Eosinophilic Esophagitis (EoE) patients and healthy volunteers from which representative cases are presented and discussed. Results indicate that, compared to endoscopic biopsy, unsedated tethered capsule endomicroscopy obtains orders of magnitude more cellular information while successfully resolving characteristic tissue microscopic features such as stratified squamous epithelium, lamina propria papillae, intraepithelial eosinophils, and gastric cardia and body/fundic mucosa epithelia. Based on the major import of whole organ, cellular-level microscopy to obviate sampling error and the clear cost and convenience advantages of unsedated procedure, we believe that this tool has the potential to become a simpler and more effective device for diagnosing and monitoring the therapeutic response of EoE and other esophageal diseases.


Assuntos
Esofagite Eosinofílica/diagnóstico , Esôfago/ultraestrutura , Mucosa Gástrica/ultraestrutura , Microscopia Confocal/métodos , Adulto , Feminino , Humanos , Masculino , Projetos Piloto
6.
Lasers Surg Med ; 49(3): 233-239, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27636715

RESUMO

BACKGROUND AND OBJECTIVE: Diagnosis of esophageal diseases is often hampered by sampling errors that are inherent in endoscopic biopsy, the standard of care. Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal endomicroscopy technology that has the potential to visualize cellular features from large regions of the esophagus, greatly decreasing the likelihood of sampling error. In this paper, we report results from a pilot clinical study imaging the human esophagus in vivo with a prototype SECM endoscopic probe. MATERIALS AND METHODS: In this pilot clinical study, six patients undergoing esophagogastroduodenoscopy (EGD) for surveillance of Barrett's esophagus (BE) were imaged with the SECM endoscopic probe. The device had a diameter of 7 mm, a length of 2 m, and a rapid-exchange guide wire provision for esophageal placement. During EGD, the distal portion of the esophagus of each patient was sprayed with 2.5% acetic acid to enhance nuclear contrast. The SECM endoscopic probe was then introduced over the guide wire to the distal esophagus and large-area confocal images were obtained by helically scanning the optics within the SECM probe. RESULTS: Large area confocal images of the distal esophagus (image length = 4.3-10 cm; image width = 2.2 cm) were rapidly acquired at a rate of ∼9 mm2 /second, resulting in short procedural times (1.8-4 minutes). SECM enabled the visualization of clinically relevant architectural and cellular features of the proximal stomach and normal and diseased esophagus, including squamous cell nuclei, BE glands, and goblet cells. CONCLUSIONS: This study demonstrates that comprehensive spectrally encoded confocal endomicroscopy is feasible and can be used to visualize architectural and cellular microscopic features from large segments of the distal esophagus at the gastroesophageal junction. By providing microscopic images that are less subject to sampling error, this technology may find utility in guiding biopsy and planning and assessing endoscopic therapy. Lasers Surg. Med. 49:233-239, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Esôfago de Barrett/patologia , Endoscopia do Sistema Digestório/métodos , Neoplasias Esofágicas/patologia , Microscopia Confocal/métodos , Lesões Pré-Cancerosas/patologia , Esôfago de Barrett/diagnóstico , Biópsia por Agulha , Diagnóstico Diferencial , Neoplasias Esofágicas/diagnóstico , Feminino , Humanos , Imuno-Histoquímica , Masculino , Monitorização Fisiológica/métodos , Projetos Piloto , Lesões Pré-Cancerosas/diagnóstico , Estudos de Amostragem
7.
J Biomed Opt ; 21(10): 104001, 2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27689919

RESUMO

Due to the relatively high cost and inconvenience of upper endoscopic biopsy and the rising incidence of esophageal adenocarcinoma, there is currently a need for an improved method for screening for Barrett's esophagus. Ideally, such a test would be applied in the primary care setting and patients referred to endoscopy if the result is suspicious for Barrett's. Tethered capsule endomicroscopy (TCE) is a recently developed technology that rapidly acquires microscopic images of the entire esophagus in unsedated subjects. Here, we present our first experience with clinical translation and feasibility of TCE in a primary care practice. The acceptance of the TCE device by the primary care clinical staff and patients shows the potential of this device to be useful as a screening tool for a broader population.

8.
Biomed Opt Express ; 7(2): 409-19, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26977350

RESUMO

Optical coherence tomography (OCT) is an optical diagnostic modality that can acquire cross-sectional images of the microscopic structure of the esophagus, including Barrett's esophagus (BE) and associated dysplasia. We developed a swallowable tethered capsule OCT endomicroscopy (TCE) device that acquires high-resolution images of entire gastrointestinal (GI) tract luminal organs. This device has a potential to become a screening method that identifies patients with an abnormal esophagus that should be further referred for upper endoscopy. Currently, the characterization of the OCT-TCE esophageal wall data set is performed manually, which is time-consuming and inefficient. Additionally, since the capsule optics optimally focus light approximately 500 µm outside the capsule wall and the best quality images are obtained when the tissue is in full contact with the capsule, it is crucial to provide feedback for the operator about tissue contact during the imaging procedure. In this study, we developed a fully automated algorithm for the segmentation of in vivo OCT-TCE data sets and characterization of the esophageal wall. The algorithm provides a two-dimensional representation of both the contact map from the data collected in human clinical studies as well as a tissue map depicting areas of BE with or without dysplasia. Results suggest that these techniques can potentially improve the current TCE data acquisition procedure and provide an efficient characterization of the diseased esophageal wall.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA