Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Health Phys ; 120(6): 641-647, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33879646

RESUMO

ABSTRACT: The maximum annual radiation ocular dose limit for medical staff has been reduced to 20 mSv in the current European directive 2013/59/Euratom. This multi-centric study aims at reporting the protected and unprotected eye lens doses in different fluoroscopically guided interventions and to evaluate any other factors that could influence the ocular dose. From July 2018 to July 2019, ocular radiation doses of six interventionists of four departments during complex interventions were recorded with a thermoluminescent dosimeter in front of and behind radiation protection glasses to measure the protected and unprotected doses. The position of personnel, intervention type, fluoroscopy time, total body dose and use of pre-installed protection devices like lead acrylic shields were also systematically recorded. Linear regression analysis was used to estimate the doses at 2 y and 5 y. The annual unprotected/protected ocular doses of six interventionists were 67/21, 32.7/3.3, 27.4/5.1, 7/0, 21.8/2.2, and 0/0 mSv, respectively. The unprotected dose crossed the 20-mSv annual limits for four interventionists and protected dose for one less experienced interventionist. The estimated 5-y protected ocular dose of this interventionist was 101.318 mSv (95%CI 96.066-106.57), also crossing the 5-y limit. The use of a lead acrylic shield was observed to have a significant effect in reducing ocular doses. The annual unprotected and protected ocular doses for interventionists dealing with complex interventions could cross the present permitted yearly limit. The measurement of significant protected ocular dose behind the radiation protection glasses emphasizes the additional indispensable role of pre-installed radiation protection devices and training in reducing radiation doses for complex procedures.


Assuntos
Cristalino , Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Dispositivos de Proteção dos Olhos , Humanos , Cristalino/efeitos da radiação , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Raios X
2.
Cardiovasc Intervent Radiol ; 41(7): 1074-1080, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29687260

RESUMO

PURPOSE: The annual permissible radiation ocular lens dose has been reduced to 20 millisieverts (mSv) in the current European directive 2013/59/Euratom. The aim of this study was to evaluate the personal radiation dose for vascular interventions with special focus on ocular lens dose. MATERIALS AND METHODS: From May 2016 to October 2016, the personal radiation doses of two interventionists and four technicians were prospectively recorded during 206 vascular interventions. The position of personnel, intervention type and fluoroscopy time were recorded. Parameters evaluated were total body dose measured by film dosimeter, hand dose measured by ring thermoluminescent dosimeter (TLD) and ocular lens dose measured by TLD placed in front of the safety glasses. Linear regression analysis was used to estimate the dose at 2 and 5 years. RESULTS: The ocular lens dose, hand and total body dose of the two interventionists were 11/5, 56/47 and 0.6 mSv each, respectively. The estimated 5-year ocular dose was 113.08 mSv (95% CI 38.2-187.97)/40.95 (95% CI 16.9-64.7). Similarly, hand dose was 608.4 mSv (95% CI 442.78-774.38)/514.47 (95% CI 329.83-699.10) and body dose 6.07 mSv (95% CI 4.70-8.22)/5.12 (95% CI 3.65-6.59), respectively. Amongst four technicians, only the first assistant showed recordings of 0.3 mSv body dose, 2 mSv ocular lens dose and 5 mSv hand dose. CONCLUSION: The yearly ocular lens dose, particularly for interventionists dealing with complex interventions, could cross the permitted yearly limit set by the new Euratom directive. Therefore, X-ray safety glasses would become mandatory for complex radiological vascular interventions. LEVEL OF EVIDENCE: Level III, non-randomized controlled cohort/follow-up study.


Assuntos
Dispositivos de Proteção dos Olhos , Exposição Ocupacional/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Radiografia Intervencionista/efeitos adversos , Doenças Vasculares/terapia , Europa (Continente) , Feminino , Fluoroscopia/efeitos adversos , Seguimentos , Guias como Assunto , Humanos , Estudos Prospectivos , Dosímetros de Radiação , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA