Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Otol Neurotol ; 41(4): e441-e448, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32176128

RESUMO

OBJECTIVE: The objective of this work was to study the feasibility of minimally invasive cochlear implantation under intraoperative computerized tomography-scan coupled to navigation. MATERIALS AND METHODS: Five human resin temporal bones (two adults and three children) were used. Initially, a temporal bone imaging was obtained by the intraoperative CT-scan coupled to the navigation (O-ARM). The navigation-assisted drilling began at the mastoid surface creating a conical tunnel (4-2 mm in diameter) through the facial recess and down to the round window. A cochleostomy was performed based on the navigation. A sham electrode array was inserted in the drilled tunnel and into the cochlea.Postoperative CT-scan and dissection were performed to evaluate the trajectory, and possible injury to the external auditory canal, ossicles, or facial nerve. RESULTS: The mean duration of the procedure was 24.4 ±â€Š3.79 minutes (range, 15-35). Cochleostomy was possible in all cases without injury to other structures. The sham array was inside the cochlea in all cases. The mean distance between the drilled canal and the mastoid portion of the facial nerve was 1.2 ±â€Š0.07 mm (range, 1.08-1.38). The mean tracking error was 0.6 ±â€Š0.26 mm (range, 0.20-0.72) at the entry point, 0.6 ±â€Š0.33 mm (range, 0.2-1.02) at the facial nerve and 0.4 ±â€Š0.07 mm (range, 0.36-0.51) at the cochleostomy. CONCLUSION: Cochlear implantation through a minimally invasive approach assisted by intraoperative imaging combined with navigation was feasible in operating room environment and experimental conditions.


Assuntos
Implante Coclear , Cirurgia Assistida por Computador , Adulto , Criança , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Humanos , Imageamento Tridimensional , Neuronavegação , Tomografia Computadorizada por Raios X
2.
J Clin Med ; 7(11)2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30445692

RESUMO

Cystic echinococcosis (CE) is a cosmopolitan parasitic zoonosis affecting more than one million people worldwide. In humans, primary bone CE is rare and involvement of E. ortleppi is very uncommon. We report here the first case of primary vertebral cystic echinococcosis due to E. ortleppi in Burgundy, France.

3.
Orthop Traumatol Surg Res ; 104(5): 597-602, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29969721

RESUMO

HYPOTHESIS: Percutaneous pedicle screw fixations (PPSF) are increasingly used in spine surgery, minimizing morbidity through less muscle breakdown but at the cost of intraoperative fluoroscopic guidance that generates high radiation exposure. Few studies have been conducted to measure them accurately. MATERIAL AND METHODS: The objective of our study is to quantify, during a PPSF carried out in different experimented centers respecting current radiation protection recommendations, this irradiation at the level of the surgeon and the patient. We have prospectively included 100 FPVP procedures for which we have collected radiation doses from the main operator. For each procedure, the doses of whole-body radiation, lens and extremities were measured. RESULTS: Our results show a mean whole body, extremity and lens exposure dose per procedure reaching 1.7±2.8µSv, 204.7±260.9µSv and 30.5±25.9µSv, respectively. According to these values, the exposure of the surgeon's extremities and lens will exceed the annual limit allowed by the International Commission on Radiological Protection (ICRP) after 2440 and 4840 procedures respectively. CONCLUSION: Recent European guidelines will reduce the maximum annual exposure dose from 150 to 20mSv. The number of surgical procedures to not reach the eye threshold, according to our results, should not exceed 645 procedures per year. Pending the democratization of neuronavigation systems, the use of conventional fluoroscopy exposes the eyes in the first place. Therefore they must be protected by leaded glasses. LEVEL OF PROOF: IV, case series.


Assuntos
Fluoroscopia , Exposição Ocupacional/análise , Procedimentos Ortopédicos , Exposição à Radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Extremidades , Dispositivos de Proteção dos Olhos , Feminino , Humanos , Cristalino , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/normas , Saúde Ocupacional/normas , Parafusos Pediculares , Estudos Prospectivos , Proteção Radiológica , Cirurgia Assistida por Computador , Vértebras Torácicas/cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA