Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Indian J Orthop ; 56(7): 1112-1122, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35813536

RESUMO

Background: Patient-Reported Outcome Measures (PROMs) are widely used for measurement of functional outcomes after orthopaedic trauma. However, PROMs rely on patient collaboration and suffer from various types of bias. Wearable Activity Monitors (WAMs) are increasingly used to objectify functional assessment. The objectives of this systematic review were to identify and characterise the WAMs technology and metrics currently used for orthopaedic trauma research. Methods: PubMed and Embase biomedical literature search engines were queried. Eligibility criteria included: Human clinical studies published in the English language between 2010 and 2019 involving fracture management and WAMs. Variables collected from each article included: Technology used, vendor/product, WAM body location, metrics measured, measurement time period, year of publication, study geographic location, phase of treatment studied, fractures studied, number of patients studied, sex and age of the study subjects, and study level of evidence. Six investigators reviewed the resulting papers. Descriptive statistics of variables of interest were used to analyse the data. Results: One hundred and thirty-six papers were available for analysis, showing an increasing trend of publications per year. Accelerometry followed by plantar pressure insoles were the most commonly employed technologies. The most common location for WAM placement was insoles, followed by the waist. The most commonly studied fracture type was hip fractures followed by fragility fractures in general, ankle, "lower extremity", and tibial fractures. The rehabilitation phase following surgery was the most commonly studied period. Sleep duration, activity time or step counts were the most commonly reported WAM metrics. A preferred, clinically validated WAM metric was not identified. Conclusions: WAMs have an increasing presence in the orthopaedic trauma literature. The optimal implementation of this technology and its use to understand patients' pre-injury and post-injury functions is currently insufficiently explored and represents an area that will benefit from future study. Systematic review registration number: PROSPERO ID:210344. Supplementary Information: The online version contains supplementary material available at 10.1007/s43465-022-00629-0.

2.
Injury ; 53(6): 1961-1965, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35307166

RESUMO

The use of wearable sensors to track activity is increasing. Therefore, a survey among AO Trauma members was conducted to provide an overview of their current utilization and determine future needs and directions. A cross sectional expert opinion survey was administered to members of AO Trauma. Respondents were surveyed concerning their experience, subspeciality, current use characteristics, as well as future needs concerning wearable technology. Three hundred and thirty-three survey sets were available for analysis (Response Rate 16.2%). 20.7% of respondents already use wearable technology as part of their clinical treatment. The most prevalent technology was accelerometry combined with smartphones (75.4%) to measure general patient activity. To facilitate the use of wearable technology in the future, the most pressing issues were cost, patient compliance and validity of results. Wearable activity monitors are currently being used in trauma surgery. Surgeons employing these technologies mostly measure simple activity or activity associated parameters. Cost was the greatest perceived barrier to implementation. Further research, especially concerning the interpretation of the outcome values obtained, is required to facilitate wearable activity monitoring as an objective patient outcome measurement tool.


Assuntos
Dispositivos Eletrônicos Vestíveis , Acelerometria , Estudos Transversais , Humanos , Monitorização Fisiológica , Inquéritos e Questionários
3.
EFORT Open Rev ; 5(7): 408-420, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32818068

RESUMO

There are many digital solutions which assist the orthopaedic trauma surgeon. This already broad field is rapidly expanding, making a complete overview of the existing solutions difficult.The AO Foundation has established a task force to address the need for an overview of digital solutions in the field of orthopaedic trauma surgery.Areas of new technology which will help the surgeon gain a greater understanding of these possible solutions are reviewed.We propose a categorization of the current needs in orthopaedic trauma surgery matched with available or potential digital solutions, and provide a narrative overview of this broad topic, including the needs, solutions and basic rules to ensure adequate use in orthopaedic trauma surgery. We seek to make this field more accessible, allowing for technological solutions to be clearly matched to trauma surgeons' needs. Cite this article: EFORT Open Rev 2020;5:408-420. DOI: 10.1302/2058-5241.5.200021.

4.
Acta Orthop ; 91(5): 576-580, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32496841

RESUMO

Background and purpose - Hip resurfacing arthroplasty (HRA) was designed for the highly active patient because of the various theoretical advantages compared with stemmed total hip arthroplasty (THA), but has shown high failure rates. Physical activity (PA) after arthroplasty is frequently determined with the use of questionnaires, which are known for their subjective nature, recall bias, and ceiling effect. These disadvantages are not applicable to physical activity monitoring (AM) using sensors. We compared objectively measured PA at long-term follow-up in a matched cohort of HRA and stemmed THA subjects.Patients and methods - We compared 2 groups of 16 patients (12 males) in each group, one having received unilateral HRA (median age 56 years at surgery) and a matched group having received unilateral stemmed THA with a small diameter femoral head (28 mm) on conventional polyethylene (median age 60 years at surgery) with osteoarthritis as indication for surgery, 10 years after surgery. Groups were matched by sex, age at surgery, and BMI. The daily habitual PA was measured over 4 consecutive days in daily living using a 3-axis accelerometer, gyroscope, and magnetometer. Both quantitative parameters (time standing, sitting, walking, number of steps, and sit-stand transfers) and qualitative parameters (walking cadence) were determined.Results - The AM was worn for a median 13 (11-16) hours per day. The median daily step count was 5,546 (2,274-9,966) for the HRA group and 4,583 (1,567-11,749) for the stemmed THA-group with 39 (21-74) versus 37 (24-62) daily sit-stand transfers respectively. The other PA parameters were also similar in both groups.Interpretation - We found similar median PA levels and also identical ranges. While short-term effects may exist, ageing and related behavioral adaptations or other effects seem to render the theoretical activity benefits from HRA irrelevant at longer follow-up.


Assuntos
Artroplastia de Quadril/métodos , Exercício Físico , Prótese de Quadril , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
5.
J Orthop ; 18: 213-217, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32071507

RESUMO

INTRODUCTION: An increase in blood serum metal ion levels is seen after implantation of all metal-on-metal (MoM) hip prosthesis. Systemic complaints contributed to raised cobalt ion concentrations in patients with MoM arthroplasty may lead to a variety of symptoms. The aim of this study is to investigate self-reported systemic complaints in association with cobalt ion concentrations in patients with any type of MoM hip prosthesis. METHODS: A cohort study was conducted. Patients with both unilateral and bilateral, resurfacing and large head metal on metal total hip arthroplasties (LHMoM THA) were included. Cobalt ion concentrations were measured by inductively coupled plasma mass spectrometry. Based on the known cobalt toxicity symptoms of case-reports and toxicology reports a new non-validated questionnaire was developed. Analysis was performed on two groups; a low cobalt ion concentration group and a high cobalt ion concentration group. RESULTS: A total of 62 patients were included with a mean age at surgery of 60.8 ± 9.3 years and a mean follow up of 6.3 ± 1.4 years. Mean cobalt ion concentrations were 104 ± 141 nmol/L (9-833). Based on the different thresholds (120-170 or 220 nmol/L) the low cobalt ion concentration group consisted of 44 (71%), 51 (82%) or 55 (89%) subjects respectively. In the 120 nmol/L and 170 nmol/L thresholds a significant difference in age was found. The composite score for OVS increased from 54% to 57%-68% with rising threshold value, a hint at the correlation between ion concentration and symptom prevalence. DISCUSSION: Ocular-vestibular symptoms were more common in high cobalt ion concentration groups for the three threshold levels tested and with increasing prevalence for higher threshold values. With regards to proactively inquired, self-reported symptoms the threshold where effects may be present could be lower than values currently applied in clinical follow-up.

6.
J Orthop Res ; 38(10): 2206-2212, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32086825

RESUMO

Little is known about the influence of physical activity (PA) on metal ion concentrations in subjects with metal-on-metal hip arthroplasty. Implant wear is thought to be a function of use and thus of patient activity levels. It is hypothesized that daily habitual PA of patients with hip resurfacing arthroplasty (HRA) is associated with metal ion concentrations. Therefore a study was conducted in patients with a unilateral HRA at 10-years follow-up. Blood metal ion concentrations were determined. An acceleration-based activity monitor was used to measure PA in daily life. The cohort consisted of 12 males (75%) and 4 females (25%) with a median age at surgery of 55.5 ± 9.7 years [43.0-67.9] and a median follow-up of 9.9 ± 1.0 years [9.1-10.9]. The median cobalt and chromium ion concentrations were 25 ± 13 and 38 ± 28 nmol/L. A significant association between sit-stand transfers and high-intensity peaks with cobalt ion concentrations were found. Regarding PA and metal ion concentrations as a proxy of wear in HRA, specific activities like transfers or qualitative aspects of activity behavior like intensity, seem to matter more than the quantity of low-intensity activities like walking or cycling. This suggests that patients may safely engage in such activities to achieve important general health benefits and quality of life.


Assuntos
Cromo/sangue , Cobalto/sangue , Exercício Físico , Prótese de Quadril , Próteses Articulares Metal-Metal , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
8.
Clin Biomech (Bristol, Avon) ; 68: 89-95, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31177011

RESUMO

BACKGROUND: Restoring native hip anatomy and biomechanics is important to create a well-functioning hip arthroplasty. This study investigated the association of hip offset and leg length after hip arthroplasty with clinical outcomes, including patient reported outcome measures, the Trendelenburg Test and gait analysis. METHODS: In 77 patients undergoing primary hip arthroplasty for osteoarthritis (age mean = 65 SD = 11 years; BMI mean = 27 SD = 5 kg/m2), hip offset and leg length discrepancy were measured on anteroposterior radiographs. The Western Ontario & McMaster Universities Osteoarthritis Index, the Trendelenburg Test and gait were assessed preoperatively, and at 3 and 12 months postoperatively. An inertial measurement unit was used to derive biomechanical parameters, including spatiotemporal gait parameters and tilt angles of the pelvis. Relationships between radiographic and functional outcomes were investigated, and subgroups of patients with >15% decreased and increased femoral offset were analysed separately. FINDINGS: Patient-reported function scores and clinical tests demonstrated a few significant, weak correlations with radiographic outcomes (Spearman's ρ range = 0.26-0.32; p < 0.05). Undercorrection of femoral offset was associated with lower patient-reported function scores and with more step irregularity as well as step asymmetry during gait. Postoperative leg length inequality was associated with increased frontal plane tilt angle of the pelvis during the Trendelenburg Test and increased sagittal plane motion of the pelvis during gait. Femoral offset subgroups demonstrated no significant differences for patient-reported function scores and outcomes of the Trendelenburg Test and gait analysis. INTERPRETATION: Reduced hip offset and leg length discrepancy following hip arthroplasty seem to be marginally associated with worse clinical outcomes.


Assuntos
Artroplastia de Quadril , Marcha , Prótese de Quadril , Quadril/diagnóstico por imagem , Desigualdade de Membros Inferiores/cirurgia , Procedimentos de Cirurgia Plástica , Idoso , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Desigualdade de Membros Inferiores/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Pelve/diagnóstico por imagem , Pelve/cirurgia , Período Pós-Operatório , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Resultado do Tratamento , Reino Unido
9.
Hip Int ; 29(6): 638-646, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30479165

RESUMO

INTRODUCTION: Metal-on-metal (MoM) hip arthroplasties have shown high clinical failure rates with many patients at risk for a revision and under surveillance for high metal ion concentrations. Implant wear releasing such ions is assumed to be a function of use, i.e. the patient's physical activity. This study aimed to assess whether habitual physical activity levels of MoM patients are correlated with metal ion concentrations and are higher in patients with high (at risk) than in patients with low (safe) metal ion concentrations. METHODS: A cohort study was conducted of patients with any type of MoM hip prosthesis. Metal ion concentrations were determined using ICP-MS. Habitual physical activity of subjects was measured in daily living using an acceleration-based activity monitor. Outcome consisted of quantitative and qualitative activity parameters. RESULTS: In total, 62 patients were included. Mean age at surgery was 60.8 ± 9.3 years and follow-up was 6.3 ± 1.4 years. Cobalt concentrations were highly elevated overall (112.4 ± 137.9 nmol/L) and significantly more in bilateral (184.8 ± 106.5 nmol/L) than in unilateral cases (87.8 ± 139.4 nmol/L). No correlations were found between physical activity parameters and metal ion concentrations. Subgroup analysis of patients with low versus high cobalt concentration showed no significant differences in habitual physical activity. DISCUSSION: No correlation was found between physical activity levels and metal ion concentrations. Implant use by normal habitual activities of daily living seems not to influence metal ion concentrations.


Assuntos
Atividades Cotidianas , Artroplastia de Quadril/métodos , Exercício Físico/fisiologia , Íons/sangue , Próteses Articulares Metal-Metal , Metais/sangue , Osteoartrite do Quadril/cirurgia , Adulto , Idoso , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/sangue
10.
Acta Orthop Belg ; 84(2): 163-171, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30462599

RESUMO

To investigate changes in leg power, pelvic movement and patient-reported outcome in patients with hip dysplasia one year after periacetabular osteotomy. Forty-one patients (7 males) with a mean age of 28.8 years scheduled for periacetabular osteotomy were tested before surgery, and 4 and 12 months after. Leg power, pelvic range of motion and the Hip and Groin Outcome Score (HAGOS) was collected. One year after surgery, power in the operated leg had improved (p = 0.004) and there was no significant difference between power in the operated leg and contralateral leg (p = 0.22). In the frontal plane, pelvic range of motion decreased significant during stair-climbing and stepping down. The same pattern was seen in the sagittal plane but the changes were non-significant. All subscales on the HAGOS improved significantly over time (p < 0.001). Leg power and pelvic range of motion in patients with symptomatic hip dysplasia improved 12 months after periacetabular.


Assuntos
Acetábulo/cirurgia , Exercício Físico/fisiologia , Luxação do Quadril/fisiopatologia , Luxação do Quadril/cirurgia , Perna (Membro)/fisiopatologia , Osteotomia/métodos , Amplitude de Movimento Articular/fisiologia , Adolescente , Adulto , Teste de Esforço , Feminino , Humanos , Masculino , Força Muscular/fisiologia , Pelve/fisiopatologia , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
11.
J Orthop Translat ; 14: 8-15, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30035028

RESUMO

BACKGROUND: It is well documented that patients with knee osteoarthritis (KOA) suffer from reduced physical function and that function of the affected knee is improved after knee joint replacement (KJR). However, it remains uncertain whether patients with KOA are less physically active than healthy people and whether patients increase their level of physical activity after surgery to a level comparable with that of healthy people. The aim of this study was to examine whether patients with KOA are less physically active than healthy participants and whether patients who have undergone KJR show an increased activity and achieve the same level of physical activity as healthy participants 5 years postoperatively. METHODS: Fifty-four patients with KOA (29 women; mean age 62 ± 8.6; mean body mass index (BMI) 27 ± 5), 52 patients who had KJR due to KOA 5 years earlier (26 women; mean age 66 ± 7.2; mean BMI 30 ± 5) and 171 healthy participants (76 women, mean age 64 ± 9.7, mean BMI 26 ± 5) were included in this cross-sectional study. The level of physical activity was measured over a mean period of 5.5 days with a triaxial accelerometer mounted on the thigh. Number of daily steps, number of daily short walking bouts of <10 s duration and number of daily transfers from sitting to standing position were recorded. Data were analysed using two sample t tests and were adjusted for age, gender and BMI. RESULTS: Patients with KOA did not differ significantly from healthy participants regarding daily steps (+321, p = 0.50) or daily transfers from sitting to standing (+1.9, p = 0.52) but performed significantly less daily short walking bouts <10 s (-11.9, p = 0.02). Patients after KJR did not differ significantly from healthy participants regarding daily steps (-281, p = 0.60) of transfers from sitting to standing position (-3.2, p = 0.32) but performed significantly less daily short walking bouts <10 s (-21.7, p = 0.001). CONCLUSION: Patients with KOA and KJR showed no significant reduction in number of daily step counts and transfers from sitting to standing position when compared with matched healthy controls. However, the number of short walking bouts was reduced in patients with KOA and by twice as much in patients with KJR. This indicates that KOA and treatment with KJR hardly affect health-related general activity but do affect specific physical activity behaviour potentially indicative of KOA or post-KJR functional limitations. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Activity monitoring with an accelerometer-based method gives insights into health-related general activity levels such as total daily steps and specific parameters such as short walking bouts, which may serve as an objective outcome measure in clinical practice.

12.
Perspect Med Educ ; 7(2): 126-132, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29476426

RESUMO

AIM: To investigate whether the current, generally accepted practice of orthopaedic surgical skills training can raise the performance of supervised residents to levels equal to those of experienced orthopaedic surgeons when it comes to clinical outcomes or implant position after total knee arthroplasty. METHODS: In a retrospective analysis of primary total knee arthroplasty outcomes (minimum follow-up of 12 months) procedures were split into two groups: supervised orthopaedic residents as first surgeon (group R), and experienced senior orthopaedic surgeons as first surgeon (group S). Outcome data that were compared 1 year postoperatively were operation times, complications, revisions, Knee Society Scores (KSS) and radiological implant positions. RESULTS: Of 642 included procedures, 220 were assigned to group R and 422 to group S. No statistically significant differences between the two groups were found in patient demographics. Operation time differed significantly (group R: 81.3 min vs. group S: 71.3 min (p = 0.000)). No statistically significant differences were found for complications (p = 0.659), revision rate (p = 0.722), femoral angle (p = 0.871), tibial angle (p = 0.804), femoral slope (p = 0.779), tibial slope (p = 0.765) and KSS (p = 0.148). DISCUSSION AND CONCLUSION: Supervised residents needed 10 minutes extra operation time, but they provided the same quality of care in primary total knee arthroplasty as experienced orthopaedic surgeons concerning complication rates, revisions, implant position on radiographs and KSS. The currently used training procedure in which the supervising surgeon and the resident decide if the resident is ready to be first surgeon is safe for patients.


Assuntos
Artroplastia do Joelho/normas , Competência Clínica/normas , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/classificação , Artroplastia do Joelho/métodos , Feminino , Humanos , Masculino , Países Baixos , Cirurgiões Ortopédicos/normas , Cirurgiões Ortopédicos/tendências , Ortopedia/métodos , Ortopedia/normas , Estudos Retrospectivos , Ensino/normas
13.
Ann Phys Rehabil Med ; 59(5-6): 308-313, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27659237

RESUMO

BACKGROUND: A growing need in clinical practice of rehabilitation and orthopaedic medicine is for objective outcome tools to estimate physical activity. Current techniques show limited validity or are too demanding for routine clinical use. Accelerometer-based activity monitors (AMs) have shown promise for measuring physical activity in healthy people but lack validity in impaired patients. OBJECTIVES: This study aimed to validate an accelerometer-based AM in impaired, slow-walking, crutch-supported patients after total joint arthroplasty (TJA). METHODS: Shortly after TJA, patients who were safely mobilized with 2 crutches and 8 healthy participants completed a trial of different activities while wearing the AM on the lateral upper leg and being videotaped. Outcome variables (e.g., time walking, number of gait cycles, sit-stand-sit transfers) were compared to video recordings, and sensitivity, predictive value and mean percentage difference (MPD) values were calculated. RESULTS: We included 40 patients (mean age: 65±9 years; mean BMI: 30±6kg/m2; male:female ratio: 18:22) and 8 healthy participants (mean age: 49±20 years; mean BMI: 23±0.7kg/m2; male:female ratio: 5:3). The AM showed excellent sensitivity (>95%) and predictive value (>95%) in identifying activities (e.g., walking, sitting, resting) and detecting the number of gait cycles and sit-stand-sit transfers (mean percentage difference: ±2%). Detection of number of steps ascending and descending stairs and cadence was more difficult but still showed good results (mean percentage difference: ±7%). CONCLUSIONS: This is the first validation study to assess physical activity with an AM in impaired, slow-walking, crutch-supported patients. The AM was a valid tool for measuring physical activity in these patients. The tool may help in evaluating and optimizing rehabilitation programs for patients after TJA, those recovering from stroke or chronic impaired patients.


Assuntos
Acelerometria/instrumentação , Artroplastia de Substituição/reabilitação , Exercício Físico , Caminhada/fisiologia , Acelerometria/métodos , Adulto , Idoso , Estudos de Casos e Controles , Muletas , Feminino , Humanos , Perna (Membro)/fisiologia , Masculino , Pessoa de Meia-Idade , Postura/fisiologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Knee Surg Sports Traumatol Arthrosc ; 22(12): 2900-10, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25274089

RESUMO

PURPOSE: Previous investigations suggested that the geometry of the proximal femur may be related to osteoarthritis of the tibiofemoral joint and various patellofemoral joint conditions. This study aims to investigate the correlation between proximal and distal femoral geometry. Such a correlation could aid our understanding of patient complications after total knee arthroplasty (TKA) and be of benefit for further development of kinematic approaches in TKA. METHODS: CT scans of 60 subjects (30 males, 30 females) were used to identify anatomical landmarks to calculate anatomical parameters of the femur, including the femoral neck anteversion angle, neck-shaft angle (NSA), mediolateral offset (ML-offset), condylar twist angle (CTA), trochlear sulcus angle (TSA) and medial/lateral trochlear inclination angles (MTIA/LTIA). Correlation analyses were carried out to assess the relationship between these parameters, and the effect of gender was investigated. RESULTS: The CTA, TSA and LTIA showed no correlation with any proximal parameter. The MTIA was correlated with all three proximal parameters, mostly with the NSA and ML-offset. Per 5° increase in NSA, the MTIA was 2.1° lower (p < 0.01), and for every 5 mm increase in ML-offset, there was a 2.6° increase in MTIA (p < 0.01). These results were strongest and statistically significant in females and not in males and were independent of length and weight. CONCLUSIONS: Proximal femoral geometry is distinctively linked with trochlear morphology. In order to improve knowledge on the physiological kinematics of the knee joint and to improve the concept of kinematic knee replacement, the proximal femur seems to be a factor of clinical importance. LEVEL OF EVIDENCE: III.


Assuntos
Fêmur/diagnóstico por imagem , Idoso de 80 Anos ou mais , Feminino , Fêmur/anatomia & histologia , Humanos , Masculino , Tíbia/anatomia & histologia , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X
15.
BMC Musculoskelet Disord ; 13: 220, 2012 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-23148591

RESUMO

BACKGROUND: Joint replacement is an effective intervention for people with advanced arthritis, although there is an important minority of patients who do not improve post-operatively. There is a need for robust evidence on outcomes after surgery, but there are a number of measures that assess function after joint replacement, many of which lack any clear theoretical basis. The World Health Organisation has introduced the International Classification of Functioning, Disability and Health (ICF), which divides function into three separate domains: Impairment, activity limitations and participation restrictions. The aim of this study is to compare the properties and responsiveness of a selection of commonly used outcome tools that assess function, examine how well they relate to the ICF concepts, and to explore the changes in the measures over time. METHODS/DESIGN: Two hundred and sixty three patients listed for lower limb joint replacement at an elective orthopaedic centre have been recruited into this study. Participants attend the hospital for a research appointment prior to surgery and then at 3-months and 1-year after surgery. At each assessment time, function is assessed using a range of measures. Self-report function is assessed using the WOMAC, Aberdeen Impairment, Activity Limitation and Participation Restriction Measure, SF-12 and Measure Yourself Medical Outcome Profile 2. Clinician-administered measures of function include the American Knee Society Score for knee patients and the Harris Hip Score for hip patients. Performance tests include the timed 20-metre walk, timed get up and go, sit-to-stand-to-sit, step tests and single stance balance test. During the performance tests, participants wear an inertial sensor and data from motion analysis are collected. Statistical analysis will include exploring the relationship between measures describing the same ICF concepts, assessing responsiveness, and studying changes in measures over time. DISCUSSION: There are a range of tools that can be used to assess function before and after joint replacement, with little information about how these various measures compare in their properties and responsiveness. This study aims to provide this data on a selection of commonly used assessments of function, and explore how they relate to the ICF domains.


Assuntos
Artroplastia de Substituição/métodos , Artroplastia de Substituição/tendências , Recuperação de Função Fisiológica/fisiologia , Artroplastia de Substituição/normas , Artroplastia de Quadril/métodos , Artroplastia de Quadril/normas , Artroplastia de Quadril/tendências , Artroplastia do Joelho/métodos , Artroplastia do Joelho/normas , Artroplastia do Joelho/tendências , Estudos de Coortes , Seguimentos , Humanos , Autorrelato/normas , Resultado do Tratamento
16.
Knee Surg Sports Traumatol Arthrosc ; 19(6): 943-51, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20953864

RESUMO

PURPOSE: In total knee arthroplasty, tissue-sparing techniques are considered more important, as functional gain could become more advantageous when early mobilization is commenced. The parapatellar approach is most often used, whereas the subvastus approach is a suitable alternative. Presently, it is unknown, according to true objective measurements, which of the two is most advantageous. METHODS: In this prospective randomized double-blind, short-term trial measurements (KSS, WOMAC, PDI, VAS, ability to perform) were obtained at day 1, day 3, 1 week, 6 weeks, and 3 months. RESULTS: The subvastus group (n=20) showed only significantly less extension lag direct postoperative (P=0.04) compared with the parapatellar group (n=20). Other scores were not significantly different. The Dynaport®knee test, an objective performance-based tool, could not demonstrate significant differences. A blunt anatomical dissection was carried out in both observational and histological to support findings. A dense innervation of the distal vastus medialis was found. This is at risk employing the subvastus approach. Both approaches harm the suprapatellar bursa. The vastus medialis sheath must be detached distally to open the knee joint. No true separate vastus medialis obliquus could be identified. CONCLUSION: Comparable to literature, only mild advantage employing the subvastus approach was found, but only early postoperative and not objectively. As this approach is also not suitable in every case, we will continue to use the parapatellar approach.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/anatomia & histologia , Patela/cirurgia , Músculo Quadríceps/cirurgia , Amplitude de Movimento Articular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Cadáver , Dissecação , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Medição da Dor , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Radiografia , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Clin Orthop Relat Res ; 467(4): 979-84, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19030941

RESUMO

UNLABELLED: Wear particle-induced osteolysis is a major cause of aseptic loosening in THA. Increasing wear resistance of polyethylene (PE) occurs by increasing the cross-link density and early reports document low wear rates with such implants. To confirm longer-term reductions in wear we compared cross-linked polyethylene (irradiation in nitrogen, annealing) with historical polyethylene (irradiation in air) in a prospective, randomized clinical study involving 48 patients who underwent THAs with a minimum followup of 7 years (mean, 8 years; range, 7-9 years). The insert material was the only variable. The Harris hip score, radiographic signs of osteolysis, and polyethylene wear were recorded annually. Twenty-three historical and 17 moderately cross-linked polyethylene inserts were analyzed (five patients died, three were lost to followup). At 8 years, the wear rate was lower for cross-linked polyethylene (0.088 +/- 0.03 mm/year) than for the historical polyethylene (0.142 +/- 0.07 mm/year). This reduction (38%) did not diminish with time (33% at 5 years). Acetabular cyst formation was less frequent (39% versus 12%), affected fewer DeLee and Charnley zones (17% versus 4%), and was less severe for the cross-linked polyethylene. The only revision was for an aseptically loose cup in the historical polyethylene group. Moderately cross-linked polyethylene maintained its wear advantage with time and produced less osteolysis, showing no signs of aging at mid-term followup. LEVEL OF EVIDENCE: Level I, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/instrumentação , Reagentes de Ligações Cruzadas , Prótese de Quadril , Polietileno , Falha de Prótese , Acetábulo/patologia , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Indicadores Básicos de Saúde , Articulação do Quadril/patologia , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/etiologia , Osteólise/patologia , Polietileno/química , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular , Resultado do Tratamento
18.
Arch Orthop Trauma Surg ; 129(2): 259-65, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18488236

RESUMO

INTRODUCTION: Whether to resurface the patella or not in total knee arthroplasty still remains undecided. Classical scores and questionnaires might not be responsive or demanding enough. This study used two accelerometer based systems to study the hypothesis whether performance based tests are able to detect a difference in patients with or without a resurfaced patella. METHOD: In this retrospective study 53 patients were included and divided into a resurfaced group (n = 31) and a non-resurfaced group (n = 22). Both groups were matched on age and longevity of follow up. Patients were clinically assessed using the Knee Society Score (KSS) at various time points. At final follow up patients were also assessed once using the Dynaport Knee Test and the Minimod Gait Test. RESULTS: The Dynaport Knee Test showed a significant functional advantage for patients with a resurfaced patella [44 vs. 39.7 (P = 0.042)], whereas KSS and The Minimod were not significant (P values ranging from 0.07 to 0.75). Similar to other reports in literature, using the KSS, it was not possible to identify significant difference between patella resurfacing or retaining in total knee arthroplasty, however using a performance based test it was possible to determine significant difference. The found advantage of patella resurfacing may be less due to pain relief but due to a functional benefit during demanding motion tasks. This finding indicates that current measurement tools may not be accurate or specific enough to detect this difference. Therefore, we recommend complementing the classic evaluation tools with an objective functional test, when conducting a randomized trial to answer the indecision whether to resurface the patella or not.


Assuntos
Artroplastia do Joelho/métodos , Osteoartrite do Joelho/cirurgia , Patela/cirurgia , Idoso , Humanos , Recuperação de Função Fisiológica , Estudos Retrospectivos , Resultado do Tratamento
19.
Knee Surg Sports Traumatol Arthrosc ; 15(10): 1187-93, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17589828

RESUMO

In literature no reports appear on functional recovery of unicompartmental knee replacement using both subjective and objective methods. Functional aspects are especially of importance, since prosthetic replacement is considered more often in younger patients, who require an optimal knee function for activities such as sports. In a prospective study on 38 patients with a mean age of 62.2 years functional improvement was measured. Using Knee Society Score (KSS) as a clinician based score and the Dynaport Knee Test as a functional test measurements were performed at preoperative, 3 and 6 months, 1 and 2 years, after surgery. The Dynaport Knee Test is an accelerometer-based system that objectively measures functional aspects of gait during various tasks of daily life. It consists of four sub scores. The KSS assesses pain and function. Both scores range from 0 to 100. The mean KSS preoperative was 44.0 and improved significantly to 81.7 at 3 months (P<0.001) and to 87.4 (P=0.025) at 6 months. No significant differences were noted after 6 months. The mean preoperative Dynaport Knee Test score was 35.8 and at 3 months 43.6 (P<0.001), 48.6 at 6 months (P<0.001). No significant differences were noted after 6 months follow-up. Of the Dynaport sub scores, the low demanding tasks Lift and Move and Locomotion, cease to improve beyond 6 months. The high demanding task Transfers only improved up to 3 months. However, the other high demanding tasks Rise and Descend showed improvement beyond 1 year after surgery, since the improvement from 6 months to 2 years was significant (P=0.023). This study has found that functional recovery continues beyond 6 months and even up to 2 years. It seems only more challenging tests can discriminate on improvement beyond a point where questionnaires cease to improve. The use of objective measurement methods is advocated next to the clinician based scores and self reported questionnaires.


Assuntos
Atividades Cotidianas , Artroplastia do Joelho/métodos , Avaliação de Resultados em Cuidados de Saúde , Adulto , Idoso , Feminino , Seguimentos , Humanos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Prótese do Joelho , Locomoção/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica/fisiologia
20.
J Arthroplasty ; 22(3): 369-76, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17400093

RESUMO

This study describes our experience with a hydroxyapatite-coated uncemented hemispherical component used for revision of 72 patients with aseptic loosening of the acetabular component. Preoperative Paprosky classification of the acetabular defects was 1 type I, 35 type II, and 36 type III; according to American Academy of Orthopaedic Surgeons, 14 segmental, 10 cavitary, and 48 combined. The mean follow-up was 7.6 years (range, 5.0-13.0). Complications were seen in 7 cases (9.6%). Seventy acetabular components (97.2%) showed bone ongrowth on the radiographs. The survival rate was 90.8% after a mean follow-up of 7.6 years (range, 5.0-13.0) when revision for any reason is the end point (confidence interval, 80.5%-100%) and 98.1% (confidence interval, 94.5%-100%) when aseptic loosening of the cup is the end point. We conclude that hydroxyapatite-coated cups for acetabular revision show promising results.


Assuntos
Prótese de Quadril , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril , Materiais Biocompatíveis , Durapatita , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação
SELEÇÃO DE REFERÊNCIAS