Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Proc (Bayl Univ Med Cent) ; 32(1): 140-142, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30956612

RESUMO

Radioactive iodine I-131 whole-body scintigraphy is used to monitor thyroid cancer metastases after total thyroidectomy. We present a case of a woman who was diagnosed with papillary thyroid cancer and underwent a total thyroidectomy. I-131 scintigraphy revealed abnormal accumulation of radioactive iodine in the right breast causing concern for thyroid cancer metastasis. Mammographic studies confirmed that the abnormal radiotracer accumulation was due to fat necrosis in the breast. I-131 uptake in fat necrosis is a poorly understood process that is not clearly defined in the literature. This case highlights that false-positive uptake of I-131 can mimic metastases of thyroid carcinoma.

2.
Clin Nucl Med ; 40(2): 116-22, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25525929

RESUMO

PURPOSE: Our objective was to retrospectively compare various scintigraphic methods to determine their relative accuracies and interobserver variabilities in preoperative localization of single-gland disease in patients with primary hyperparathyroidism. PATIENTS AND METHODS: We studied 292 patients who underwent preoperative parathyroid scintigraphy and surgical resection between June 2002 and September 2008. Imaging included early and delayed pinhole Tc-MIBI imaging (including anterior oblique images), similar I imaging, and MIBI SPECT. Seven different imaging combinations were assessed as follows: early MIBI only, delayed MIBI only, comparison of dual-phase early and delayed MIBI, visual subtraction of early MIBI and I images, all planar images, SPECT only, and all planar and SPECT images (ALL). Each data set was reviewed by 2 of 4 experienced nuclear physicians without knowledge of clinical information or final diagnosis. Imaging results were compared with surgical outcomes. RESULTS: The accuracy of ALL imaging for delineating abnormal/normal parathyroid glands by quadrant was 96%, 93%, 95%, and 95% for the 4 readers. The accuracies of visual subtraction of early MIBI and I images and all planar images were not significantly different from ALL for all 4 readers. All planar and SPECT images were significantly more accurate than early MIBI only, delayed MIBI only, or SPECT only for all 4 readers and better than comparison of dual-phase early and delayed MIBI for 3 of 4 readers. CONCLUSIONS: A rigorous combination of multiple imaging approaches yielded high accuracies across multiple readers for localization of a single offending parathyroid gland, but a more limited technique using MIBI/I subtraction imaging with anterior and anterior oblique pinhole images provided similarly high accuracy and limited interobserver variation of accuracy.


Assuntos
Hiperparatireoidismo Primário/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Glândulas Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA