Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Nucl Med ; 47(11): 985-988, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35972509

RESUMO

ABSTRACT: The coexistence of parathyroid hyperplasia and carcinoma is uncommon. Here we report findings of 99m Tc-sestamibi SPECT/CT study in a case of unilateral bifocal parathyroid carcinoma coexisting with parathyroid hyperplasia in a 49-year-old man. The images showed 4 foci of elevated activity around the thyroid. Histopathology confirmed the 2 lesions of the left side as parathyroid hyperplasia and the other 2 lesions of the right side as parathyroid carcinoma.


Assuntos
Adenoma , Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Adenoma/complicações , Humanos , Hiperparatireoidismo Primário/complicações , Hiperplasia/complicações , Hiperplasia/diagnóstico por imagem , Hiperplasia/patologia , Masculino , Pessoa de Meia-Idade , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/patologia , Neoplasias das Paratireoides/complicações , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/patologia , Tecnécio Tc 99m Sestamibi
2.
Int Urol Nephrol ; 54(11): 3025-3031, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35753021

RESUMO

BACKGROUND: To evaluate the clinical practicability of the Xiangya equation in estimating glomerular filtration rate (GFR) and compare with the Asian modified Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) equation, assessing whether the Xiangya equation could replace the Asian modified CKD-EPI equation as the preferred method for predicting GFR in the Chinese CKD patients in an external validation study. METHODS: The GFR was determined simultaneously by two methods: (a) the Asian modified CKD-EPI equation (GFRCKD-EPI); (b) the Xiangya equation (GFRXiangya); diagnostic performance of the two models was compared by the regression analysis, the Bland-Altman plot, bias, precision and P30 under the background of 99mTc-diethylenetriaminepentaacetic acid (99mTc-DTPA) dual plasma sample clearance method as reference method for GFR measurement (mGFR). RESULTS: A total of 158 Chinese CKD patients were included in our external study. The GFRXiangya was highly related with mGFR, with the correlation coefficient of 0.92. The regression equation was GFRXiangya = 0.55*mGFR + 28.25, where the regression coefficient was far away from one and the intercept was wide. Compared with the Asian modified CKD-EPI equation, the performance of the Xiangya equation demonstrated a poorer bias (9.5 vs - 3.3 ml/min/1.73 m2, P < 0.001), an inferior precision (23.9 vs 13.0 ml/min/1.73 m2, P < 0.001), a lower P30 (51.3% vs 73.4%, P < 0.001) and a wider 95% limit of agreement in Bland-Altman analysis (65.0 vs 44.9 ml/min/1.73 m2). CONCLUSION: Due to relatively inferior performance, the Xiangya equation could not replace the Asian modified CKD-EPI equation in estimating GFR in Chinese patients with chronic kidney disease in our external cohort.


Assuntos
Insuficiência Renal Crônica , Pentetato de Tecnécio Tc 99m , Povo Asiático , China , Creatinina , Taxa de Filtração Glomerular , Humanos , Insuficiência Renal Crônica/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA