Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Can J Cardiol ; 36(12): 1965-1974, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33157186

RESUMO

BACKGROUND: Pulmonary vein (PV) stenosis is a complication of atrial fibrillation (AF) ablation. The incidence of PV stenosis after routine post-ablation imaging remains unclear and is limited to single-centre studies. Our objective was to determine the incidence and predictors of PV stenosis following circumferential radiofrequency ablation in the multicentre Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE) trial. METHODS: Patients with symptomatic AF underwent circumferential radiofrequency ablation in one of 13 trial centres. Computed tomographic (CTA) or magnetic resonance (MRA) angiography was performed before ablation and 90 days after ablation. Two blinded reviewers measured PV diameters and areas. PVs with stenosis were classified as severe (> 70%), moderate (50%-70%), or mild (< 50%). Predictors of PV stenosis were identified by means of multivariable logistic regression. RESULTS: A total of 197 patients (median age 59.5 years, 29.4% women) were included in this substudy. PV stenosis was identified in 41 patients (20.8%) and 47 (8.2%) of 573 ablated PVs. PV stenosis was classified as mild in 42 PVs (7.3%) and moderate in 5 PVs (0.9%). No PVs had severe stenosis. Both cross-sectional area and diameter yielded similar classifications for severity of PV stenosis. Diabetes was associated with a statistically significant increased risk of PV stenosis (OR 4.91, 95% CI 1.45-16.66). CONCLUSIONS: In the first systematic multicentre evaluation of post-ablation PV stenosis, no patient acquired severe PV stenosis. Although the results are encouraging for the safety of AF ablation, 20.8% of patients had mild or moderate PV stenosis, in which the long-term effects are unknown.


Assuntos
Fibrilação Atrial , Ablação por Cateter/efeitos adversos , Angiografia por Ressonância Magnética , Complicações Pós-Operatórias , Veias Pulmonares , Estenose de Veia Pulmonar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Canadá/epidemiologia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Feminino , Humanos , Incidência , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Fatores de Risco , Índice de Gravidade de Doença , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/epidemiologia , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/fisiopatologia
2.
Expert Rev Cardiovasc Ther ; 16(7): 489-500, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29912584

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is the most frequent arrhythmia worldwide. While mostly seen in elderly, it can also affect young adults (≤ 45 years of age), older adolescent, and children. Areas covered: The aim of this review is to provide an overview of the current management of AF in young patients. Specific issues arise over diagnostic workup as well as antiarrhythmic and anticoagulation therapies. The future management and diagnostic strategies are also discussed. Expert commentary: Management of AF in the young adult is largely extrapolated from adult studies and guidelines. In this population, AF could reveal a genetic pathology (e.g. Brugada, Long QT or Short QT syndromes) or be the initial presentation of a cardiomyopathy. Therefore, thorough workup in the young population to eliminate potential malignant pathology.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Terapia Trombolítica/métodos , Adolescente , Adulto , Criança , Humanos , Adulto Jovem
3.
J Cardiovasc Electrophysiol ; 29(2): 308-315, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29064134

RESUMO

INTRODUCTION: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. METHODS AND RESULTS: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 ± 0.05 Gy·cm2 to 1.15 ± 0.04 Gy·cm2 (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 ± 0.08 to 2.00 ± 0.06 Gy·cm2 , P < 0.001) and device interventions (mean DAP 4.18 ± 0.06 to 0.64 ± 0.05 Gy·cm2 , P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. CONCLUSION: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.


Assuntos
Cateterismo Cardíaco/métodos , Técnicas Eletrofisiológicas Cardíacas , Exposição Ocupacional/prevenção & controle , Implantação de Prótese/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Humanos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Fatores de Proteção , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
4.
J Cardiovasc Electrophysiol ; 28(5): 559-563, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28233925

RESUMO

INTRODUCTION: The standard 4-minute application time for transcatheter cryoablation was determined in the 1990s when the system employed less potent chlorofluorocarbon refrigerants. The current refrigerant, nitrous oxide, generates substantially colder temperatures, with a faster cooling rate. METHODS AND RESULTS: We conducted a preclinical study on 32 mongrel dogs with stratified randomization of right atrial, right ventricular, and left ventricular chambers to 2-minute versus 4-minute application times using 8-mm electrode tip cryocatheters (Freezor Max, Medtronic CryoCath LP, Montreal, Canada). Animals were sacrificed one month after the procedure. Three-dimensional morphometric analyses were conducted in a blinded fashion. A total of 193 identified ablation lesions were processed for histological analyses, 102 with 2-minute applications and 91 with 4-minute applications. Ablation lesion surface area (167.8 ± 21.6 mm2 vs. 194.3 ± 22.6 mm2 , P = 0.40), maximum depth (4.4 ± 0.2 mm vs. 4.5 ± 0.2 mm, P = 0.71), and volume (125.7 ± 69.5 mm3 vs. 141.0 ± 83.5 mm3 , P = 0.25) were similar between groups. Overall, 90.2% of ablation lesions in the right atrium were transmural, 45.6% in the right ventricle, and 2.4% in the left ventricle, with no differences between 2-minute and 4-minute application times (P = 0.55). Thrombus was detected on the endocardial surface of 0.0% and 3.3% of ablation lesions created with 2-minute and 4-minute application times, respectively (P = 0.10). CONCLUSION: Single 2-minute and 4-minute application times result in catheter ablation lesions of similar size using the modern cryoablation system with nitrous oxide as a refrigerant. While these findings suggest the potential to reduce the standard 4-minute application time, further studies are required to compare clinical efficacy.


Assuntos
Cateterismo Cardíaco/métodos , Temperatura Baixa , Criocirurgia/métodos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Óxido Nitroso/farmacologia , Animais , Cães , Átrios do Coração/patologia , Ventrículos do Coração/patologia , Modelos Animais , Fatores de Tempo
5.
Artigo em Inglês | MEDLINE | ID: mdl-27516462

RESUMO

BACKGROUND: Early recurrences (ERs) of atrial tachyarrhythmia are common after catheter ablation of atrial fibrillation. A 3-month blanking period is recommended by current guidelines. This study sought to investigate the significance of ER during the first 3 months post ablation in predicting late recurrences and determine whether it varies according to timing. METHODS AND RESULTS: A total of 401 patients with paroxysmal atrial fibrillation undergoing pulmonary vein isolation were followed for 12 months with transtelephonic monitoring in the ADVICE (Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination) trial. Patients with atrial tachyarrhythmia ≥30 s within the 3-month blanking period were stratified according to the timing of ER. A total of 179 patients (44.6%) experienced their last episode of ER during the first (n=53), second (n=44), or third (n=82) month of the 3-month blanking period. One-year freedom from symptomatic atrial tachyarrhythmia was 77.2% in patients without ER compared with 62.6%, 36.4%, and 7.8% in patients with ER 1, 2, and 3 months post ablation, respectively (P<0.0001). Receiver operating curve analyses revealed a strong correlation between the timing of ER and late recurrence (area under the curve 0.82, P<0.0001). Corresponding hazard ratios for ER during the first, second, and third months were 1.84, 4.45, and 9.64, respectively. CONCLUSIONS: This study validates the use of a blanking period after catheter ablation for paroxysmal atrial fibrillation but calls into question the 90-day cut-off value. In particular, >90% of patients with ER during the third month post ablation experience late recurrence by 1 year. However, pending further study, repeat ablation before 90 days cannot be routinely advocated. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01058980.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Adenosina , Antiarrítmicos , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 27(11): 1337-1343, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27458078

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in substantial ionizing radiation (IR) exposure to the patient and operator. We assessed the impact of lower-dose fluoroscopy settings and a sensor-based electromagnetic tracking system (MediGuide™, MDG) on reducing IR exposure during CRT implantation. METHODS: A single-center 2-group cohort study was conducted on 348 consecutive patients, age 66.4 ± 11.0 years, 80.4% male, with CRT implant procedures from 2013 to 2015. Patients were arbitrarily assigned to MDG (N = 239) versus no MDG (N = 109) guidance. Lower-dose fluoroscopy settings were adopted in January 2015 (3 instead of 6 fps; 23 instead of 40 nGy/pulse; N = 101). RESULTS: Overall, MDG was associated with an 82.1% reduction in IR exposure (393 µGray·m2 vs. 2191 µGray·m2 , P < 0.001). Lower-dose fluoroscopy resulted in a 59.5% reduction in IR-exposure without MDG (1055 µGray·m2 vs. 2608 µGray·m2 , P < 0.001) and 81.8% reduction with MDG (108 µGray·m2 vs. 595 µGray·m2 , P < 0.001). Low-dose fluoroscopy combined with MDG was associated with a 95.9% lower exposure to IR when compared to standard fluoroscopy without MDG (108 µGray·m2 vs. 2608 µGray·m2 , P < 0.001). Procedures with MDG were shorter (96 minutes vs. 123 minutes, P < 0.001) and associated with a trend towards a higher success rate (94.6% vs. 89.0%, P = 0.062), with fewer coronary sinus cannulation failures (2.1% vs. 6.4%, P = 0.040). CONCLUSION: Low-dose fluoroscopy settings are highly effective (>50%) in reducing IR exposure during CRT implant procedures. When combined with MDG, >95% reduction in IR exposure is achieved. Moreover, MDG shortens procedural duration and may improve acute procedural outcomes.

7.
Lancet ; 386(9994): 672-9, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26211828

RESUMO

BACKGROUND: Catheter ablation is increasingly used to manage atrial fibrillation, but arrhythmia recurrences are common. Adenosine might identify pulmonary veins at risk of reconnection by unmasking dormant conduction, and thereby guide additional ablation to improve arrhythmia-free survival. We assessed whether adenosine-guided pulmonary vein isolation could prevent arrhythmia recurrence in patients undergoing radiofrequency catheter ablation for paroxysmal atrial fibrillation. METHODS: We did this randomised trial at 18 hospitals in Australia, Europe, and North America. We enrolled patients aged older than 18 years who had had at least three symptomatic atrial fibrillation episodes in the past 6 months, and for whom treatment with an antiarrhythmic drug failed. After pulmonary vein isolation, intravenous adenosine was administered. If dormant conduction was present, patients were randomly assigned (1:1) to additional adenosine-guided ablation to abolish dormant conduction or to no further ablation. If no dormant conduction was revealed, randomly selected patients were included in a registry. Patients were masked to treatment allocation and outcomes were assessed by a masked adjudicating committee. Patients were followed up for 1 year. The primary outcome was time to symptomatic atrial tachyarrhythmia after a single procedure in the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT01058980. FINDINGS: Adenosine unmasked dormant pulmonary vein conduction in 284 (53%) of 534 patients. 102 (69·4%) of 147 patients with additional adenosine-guided ablation were free from symptomatic atrial tachyarrhythmia compared with 58 (42·3%) of 137 patients with no further ablation, corresponding to an absolute risk reduction of 27·1% (95% CI 15·9-38·2; p<0·0001) and a hazard ratio of 0·44 (95% CI 0·31-0·64; p<0·0001). Of 115 patients without dormant pulmonary vein conduction, 64 (55·7%) remained free from symptomatic atrial tachyarrhythmia (p=0·0191 vs dormant conduction with no further ablation). Occurrences of serious adverse events were similar in each group. One death (massive stroke) was deemed probably related to ablation in a patient included in the registry. INTERPRETATION: Adenosine testing to identify and target dormant pulmonary vein conduction during catheter ablation of atrial fibrillation is a safe and highly effective strategy to improve arrhythmia-free survival in patients with paroxysmal atrial fibrillation. This approach should be considered for incorporation into routine clinical practice. FUNDING: Canadian Institutes of Health Research, St Jude Medical, Biosense-Webster, and M Lachapelle (Montreal Heart Institute Foundation).


Assuntos
Adenosina , Antiarrítmicos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Modelos de Riscos Proporcionais , Veias Pulmonares/cirurgia , Prevenção Secundária , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 38(7): 784-90, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25682843

RESUMO

BACKGROUND: Fluoroscopic guidance is used to position catheters during cardiac ablation. We evaluated the impact of a novel nonfluoroscopic sensor-guided electromagnetic navigation system (MG) on radiation exposure during catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL). METHODS: A total of 134 consecutive patients referred for ablation of AF (n = 44) or AFL (n = 90) ablation were prospectively enrolled. In one group the MG system was used for nonfluoroscopic catheter positioning, whereas in the conventional group standard fluoroscopy was utilized. Fluoroscopy times were assessed for each stage of procedure and total radiation exposure was quantified. RESULTS: Patient characteristics were similar between the groups. The procedural end point was achieved in all. Median (interquartile range [IQR]) fluoroscopy times were 12.5 minutes (7.6, 17.4) MG group versus 21.5 minutes (15.3, 23.0) conventional group (P < 0.0001) for AF ablation, and 0.8 minutes (0.4, 2.5) MG group versus 9.9 minutes (5.1, 22.5) conventional group (P < 0.0001) for AFL ablation. Median (IQR) total radiation exposure (µGy·m(2)) was 1,107 (906, 2,033) MG group versus 2,835 (1,688, 3,855) conventional group (P = 0.0001) for AF ablation, and 161 (65, 537) MG group versus 1,651 (796, 4,569) conventional group (P < 0.0001) for AFL ablation. No difference in total procedural time was seen. CONCLUSIONS: The use of a novel nonfluoroscopic catheter tracking system is associated with a significant reduction in radiation exposure during AF and AFL ablation (61% and 90% reduction, respectively). In the era of heightened awareness of the importance of radiation reduction, this system represents a safe and efficient tool to decrease radiation exposure during electrophysiological ablation procedures.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/métodos , Exposição à Radiação/análise , Radiografia Intervencionista/instrumentação , Fibrilação Atrial/diagnóstico por imagem , Flutter Atrial/diagnóstico por imagem , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Doses de Radiação , Proteção Radiológica , Radiografia Intervencionista/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 38(1): 63-70, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25311868

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in significant ionizing radiation (IR) exposure to the patient and operator. We report our early experience working with a novel sensor-based electromagnetic tracking system (MediGuide™, MDG, St. Jude Medical Inc., St. Paul, MN, USA), in terms of procedural IR exposure reduction. METHODS AND RESULTS: Information regarding patient demographics, procedural details, procedural duration, and IR exposure were prospectively collected on 130 consecutive CRT procedures performed between January 2013 and January 2014. Sixty procedures were performed with MDG guidance, and 70 were performed without MDG guidance. Despite a nonsignificant trend toward shorter procedure duration with the use of MDG (120 minutes vs 138 minutes with non-MDG, P = 0.088), a 66% reduction in total IR exposure (median 769 µGray · m(2) vs 2,608 µGray · m(2), P < 0.001) was found. This reduction was primarily driven by a >90% reduction in IR dose required to cannulate the coronary sinus (median 80 µGray · m(2) vs 922 µGray · m(2), P < 0.001), and to a lesser extent from a reduction in IR dose required for LV lead placement (median 330 µGray·m(2) vs 737 µGray · m(2), P = 0.059). In addition, a significant learning curve effect was observed with a significantly shorter procedural duration for the last 15 cases compared to the first 15 cases (median 98 minutes vs 175 minutes, P < 0.001). CONCLUSION: The nonfluoroscopic MDG positioning system is associated with a dramatic reduction in exposure to IR during CRT implant procedures, with a 90% decrease in the IR dose required to cannulate the coronary sinus. A steep learning curve was quantified.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Implantação de Prótese/métodos , Lesões por Radiação/prevenção & controle , Idoso , Radiação Eletromagnética , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia Assistida por Computador
10.
Heart Rhythm ; 11(11): 1919-24, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25068575

RESUMO

BACKGROUND: Atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) is associated with PV to left atrium reconduction. Effective lesion creation necessitates adequate contact force between the ablation catheter and myocardium. OBJECTIVE: The purpose of this study was to study the utility of contact force-guided ablation on immediate and long-term outcomes. METHODS: Seventy-five patients with highly symptomatic paroxysmal AF underwent wide circumferential PVI using an irrigated-tip radiofrequency catheter. In 25 patients, ablation was guided by real-time contact force measurements (CF group; SmartTouch, Biosense Webster). A control group of 50 patients underwent PVI using a standard nonforce sensing catheter (standard group; ThermoCool, Biosense Webster). After PVI, all patients underwent adenosine testing to unmask dormant conduction. Patients were followed up at 3, 6, and 12 months and by transtelephonic monitoring as well. RESULTS: Dormant conduction was unmasked and subsequently eliminated in 4 PV pairs (8%; 16% of patients) in the CF group and 35 PV pairs (35%; 52% of patients) in the standard group (P = .0004 per PV pair; P = .0029 per patient). The single-procedure, off-antiarrhythmic drug freedom from recurrent atrial arrhythmias at 1 year was 88% in the CF group vs 66% in the standard group (P = .047). Procedure duration and fluoroscopy time were significantly longer in the CF group (P = .0038 and P = .0001, respectively). CONCLUSION: The use of real-time contact force guidance results in a significant reduction in the prevalence of dormant conduction with improved long-term freedom from recurrent arrhythmias. The utility of a contact force-guided approach requires evaluation in a long-term prospective randomized study.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/cirurgia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Resultado do Tratamento
11.
Circ Arrhythm Electrophysiol ; 7(4): 605-11, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25017398

RESUMO

BACKGROUND: Phrenic nerve palsy remains the most frequent complication associated with cryoballoon-based pulmonary vein (PV) isolation. We sought to characterize our experience using a novel monitoring technique for the prevention of phrenic nerve palsy. METHODS AND RESULTS: Two hundred consecutive cryoballoon-based PV isolation procedures between October 2010 and October 2013 were studied. In addition to standard abdominal palpation during right phrenic nerve pacing from the superior vena cava, all patients underwent diaphragmatic electromyographic monitoring using surface electrodes. Cryoablation was terminated on any perceived reduction in diaphragmatic motion or a 30% decrease in the compound motor action potential (CMAP). During right-sided ablation, a ≥30% reduction in CMAP amplitude occurred in 49 patients (24.5%). Diaphragmatic motion decreased in 30 of 49 patients and was preceded by a 30% reduction in CMAP amplitude in all. In 82% of cases, this reduction in CMAP amplitude occurred during right superior PV isolation. The baseline CMAP amplitude was 946.5±609.2 mV and decreased by 13.8±13.8% at the end of application. This decrease was more marked in the 33 PVs with a reduction in diaphragmatic motion than in those without (40.9±15.3% versus 11.3±10.5%; P<0.001). In 3 cases, phrenic nerve palsy persisted beyond the end of the procedure, with all cases recovering within 6 months. Despite the shortened application all veins were isolated. At repeat procedure the right-sided PVs reconnected less frequently than the left-sided PVs in those with phrenic nerve palsy. CONCLUSIONS: Electromyographic phrenic nerve monitoring using the surface CMAP is reliable, easy to perform, and offers an early warning to impending phrenic nerve injury.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Diafragma/inervação , Eletromiografia , Monitorização Intraoperatória/métodos , Paralisia/prevenção & controle , Traumatismos dos Nervos Periféricos/prevenção & controle , Nervo Frênico/lesões , Idoso , Fibrilação Atrial/diagnóstico , Estimulação Elétrica , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Potencial Evocado Motor , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paralisia/diagnóstico , Paralisia/etiologia , Paralisia/fisiopatologia , Traumatismos dos Nervos Periféricos/diagnóstico , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/fisiopatologia , Nervo Frênico/fisiopatologia , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 25(2): 187-94, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24102792

RESUMO

INTRODUCTION: Hemi-diaphragmatic paralysis is the most common complication associated with cryoballoon ablation for atrial fibrillation, yet the histopathology of phrenic nerve injury has not been well described. METHODS AND RESULTS: A preclinical randomized study was conducted to characterize the histopathology of phrenic nerve injury induced by cryoballoon ablation and assess the potential for electromyographic (EMG) monitoring to limit phrenic nerve damage. Thirty-two dogs underwent cryoballoon ablation of the right superior pulmonary vein with the objective of inducing phrenic nerve injury. Animals were randomized 1:1 to standard monitoring (i.e., interruption of ablation upon reduction in diaphragmatic motion) versus EMG guidance (i.e., cessation of ablation upon a 30% reduction in the diaphragmatic compound motor action potential [CMAP] amplitude). The acute procedural endpoint was achieved in all dogs. Phrenic nerve injury was characterized by Wallerian degeneration, with subperineural injury to large myelinated axons and evidence of axonal regeneration. The degree of phrenic nerve injury paralleled the reduction in CMAP amplitude (P = 0.007). Animals randomized to EMG guidance had a lower incidence of acute hemi-diaphragmatic paralysis (50% vs 100%; P = 0.001), persistent paralysis at 30 days (21% vs 75%; multivariate odds ratio 0.12, 95% confidence interval [0.02, 0.69], P = 0.017), and a lesser severity of histologic injury (P = 0.001). Mature pulmonary vein ablation lesion characteristics, including circumferentiality and transmurality, were similar in both groups. CONCLUSION: Phrenic nerve injury induced by cryoballoon ablation is axonal in nature and characterized by Wallerian degeneration, with potential for recovery. An EMG-guided approach is superior to standard monitoring in limiting phrenic nerve damage.


Assuntos
Criocirurgia/efeitos adversos , Monitoração Neuromuscular/métodos , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/patologia , Nervo Frênico/lesões , Nervo Frênico/patologia , Animais , Cães , Traumatismos dos Nervos Periféricos/prevenção & controle , Resultado do Tratamento
13.
Europace ; 16(4): 500-4, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23918789

RESUMO

AIMS: The dynamic time course of entrance and exit block during pulmonary vein isolation (PVI) is unknown. The purpose of this series was to dynamically evaluate the manifestation of entrance and exit conduction block during simultaneous circumferential PVI. METHODS AND RESULTS: Pacing manoeuvres were performed during cryoballoon ablation of left-sided pulmonary veins (PVs) in 30 consecutive patients with a history of drug-refractory paroxysmal atrial fibrillation. At the onset of ablation continuous pacing was performed from the PV at a cycle length of 600 ms until the appearance of exit block. Once exit block was demonstrated, uninterrupted pacing was immediately transitioned to the distal coronary sinus (CS) catheter and continued at 600 ms throughout the rest of the cryoapplication. The timing of exit block, entrance block, and corresponding cryoballoon temperature were noted for all patients. In the 45 PVs when real-time PV recordings were available during cryothermal ablation, the presence of exit block was reliably demonstrated to precede entrance block (P < 0.0001) by a median of 5 s [interquartile range (IQR) 3, 12; median temperature at isolation -39°C (IQR -30, -45); nadir ablation temperature -53°C (IQR -48, -59)]. In all cases, when uninterrupted pacing was transitioned from the PV to the distal CS, entrance conduction from the left atrium to PV remained intact. CONCLUSION: Circumferential PV ablation results in progressive PVI, beginning with unidirectional exit block, and followed by entrance block. As exit block reliably precedes entrance block, we are able to provide justification for the exclusive use of entrance conduction block as the endpoint of cryoballoon-based PVI.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Criocirurgia/instrumentação , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Criocirurgia/métodos , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
14.
J Atr Fibrillation ; 6(6): 1063, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-27957067

RESUMO

Atrial fibrillation (AF) is the most common sustained arrhythmia seen in clinical practice, affecting approximately 1% of the overall population. While rarely life-threatening, AF is almost universally associated with increased morbidity and mortality, predominantly through an increased risk of thromboembolic events, left ventricular dysfunction, as well as significant impairments in functional capacity and health-related quality of life (HRQOL).[1-8] Improvement in HRQOL, with a secondary reduction of disability and health-care resource utilization, is one of the major therapeutic goals in the management of AF.

15.
Circ Arrhythm Electrophysiol ; 6(6): 1103-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24097372

RESUMO

BACKGROUND: Atrial fibrillation recurrence after pulmonary vein (PV) isolation is associated with PV to left atrium reconduction. We prospectively studied the use of 2 procedural techniques designed to facilitate identification of residual gaps within the index ablation line. METHODS AND RESULTS: After wide circumferential PV isolation, 40 patients received additional ablation targeted at locations of left atrial capture during high-output pacing (pace-capture group), while 40 patients underwent adenosine testing with targeted ablation at sites of dormant conduction (adenosine group). Patients were followed up at 3, 6, and 12 months. After PV isolation, high-output pace-capture was documented in 39 PVs (25%; 50% of patients) in the pace-capture group. Dormant conduction was unmasked in 34 PVs (22%; 53% of patients) in the adenosine group. A subset of 25 patients in the pace-capture group underwent adenosine testing without targeted ablation of dormant conduction. In these patients, only 10 out of 86 PVs (11.6%; 24% of patients) demonstrated dormant conduction after the elimination of local pace-capture. At a follow-up of 329±124 days, the single procedure off antiarrhythmic drug freedom from recurrent atrial fibrillation was 67.5% in the adenosine group and 65.0% in the pace-capture group (P=0.814). Procedure duration and fluoroscopy time were significantly longer in the pace-capture group (P=0.002 and P<0.001), whereas radiofrequency ablation time was comparable (P=0.192). CONCLUSIONS: The use of high-output pacing post-PV isolation results in a significant reduction in the incidence of dormant conduction with a comparable long-term freedom from recurrent atrial fibrillation (versus adenosine-guided ablation). The use of these approaches requires evaluation in a long-term prospective randomized study. [corrected].


Assuntos
Estimulação Cardíaca Artificial , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Adenosina/farmacologia , Idoso , Antiarrítmicos/farmacologia , Eletrocardiografia , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
17.
Heart Rhythm ; 10(10): 1569-75, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23892341

RESUMO

BACKGROUND: Atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) is associated with PV to left atrium reconduction. OBJECTIVE: The purpose of this study was to prospectively determine if the use of intraprocedural corticosteroids to limit the extent of tissue edema and/or inflammation alters the prevalence of spontaneous and adenosine-induced acute PV reconnection after PVI. METHODS: Prior to wide circumferential PVI, 45 patients received a single intravenous (IV) bolus of hydrocortisone 250 mg immediately after transseptal access (steroid group). Another 45 consecutive patients underwent standard PVI without IV hydrocortisone (nonsteroid group). After PVI, all patients underwent adenosine testing to unmask dormant conduction. Patients were followed at 3, 6, and 12 months. RESULTS: Dormant conduction was unmasked in a significantly higher proportion of PVs in the steroid group compared with the nonsteroid group (32.8% of PVs [60/183] vs 21.1% of PVs [37/175], P = .03). On multivariate generalized estimating equation analysis, steroid use remained independently associated with dormant PV conduction (P = .03). There was no difference in the segmental distribution of reconnection between the 2 groups. The 1-year freedom from recurrent AF did not differ between groups (P = .37). Radiofrequency time was significantly longer in the steroid group (58 ± 21 minutes vs 48 ± 18 minutes, P <.01), whereas procedure duration and fluoroscopy time were comparable (P = .55 and P = .44, respectively). CONCLUSION: A single bolus of hydrocortisone 250 mg IV prior to PVI results in greater radiofrequency requirements for PVI and a higher prevalence of dormant PV conduction unmasked by adenosine. The utility of these approaches requires evaluation in a long-term prospective randomized study.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/fisiopatologia , Adenosina/uso terapêutico , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Condutividade Elétrica , Feminino , Humanos , Hidrocortisona , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Recidiva
18.
J Cardiovasc Electrophysiol ; 24(6): 692-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23489648

RESUMO

INTRODUCTION: Optimal cryoballoon ablation parameters for pulmonary vein (PV) isolation remain to be defined. We conducted a randomized preclinical trial to compare 2- versus 4-minute ablation lesions and assess the safety of active (forced) cryoballoon deflation. METHODS AND RESULTS: Thirty-two dogs underwent PV isolation with a second-generation 23 mm cryoballoon catheter. The left superior (LSPV) and inferior (LIPV) PVs were randomized in a factorial design to (1) a single 2- versus 4-minute cryoapplication, and (2) passive versus active cryoballoon deflation. Animals were survived for 30 days, after which histopathologic analysis was performed. Acute PV isolation was attained in 89.8% of PVs after a single application (93.8% LSPV, 85.2% LIPV; P = 0.2823). Mean time to PV isolation was 29.5 ± 18.5 seconds. Although 4-minute lesions were associated with a thicker neointima than 2-minute lesions (223.8 µm versus 135.6 µm; P = 0.007), no differences were observed in procedural characteristics (freezing temperature, rewarming time), rates of acute PV isolation, or the achievement of complete circumferentially transmural lesions at 30 days (78.7% overall; 86.2% for 2 minutes vs 70.0% for 4 minutes; P = 0.285). Active deflation was associated with faster balloon rewarming but not with significant differences in mean or maximum neointimal thickness. CONCLUSION: A single application with the second-generation cryoballoon catheter results in a high rate of PV isolation. The degree of vascular injury was not increased by active balloon deflation and no differences in acute efficacy or mature transmural circumferential lesions were observed with 2- versus 4-minute applications.


Assuntos
Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Animais , Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Cães , Miocárdio/patologia , Veias Pulmonares/patologia , Distribuição Aleatória
19.
J Am Coll Cardiol ; 61(16): 1713-23, 2013 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-23500312

RESUMO

OBJECTIVES: This study sought to assess the safety and effectiveness of a novel cryoballoon ablation technology designed to achieve single-delivery pulmonary vein (PV) isolation. BACKGROUND: Standard radiofrequency ablation is effective in eliminating atrial fibrillation (AF) but requires multiple lesion delivery at the risk of significant complications. METHODS: Patients with documented symptomatic paroxysmal AF and previously failed therapy with ≥ 1 membrane active antiarrhythmic drug underwent 2:1 randomization to either cryoballoon ablation (n = 163) or drug therapy (n = 82). A 90-day blanking period allowed for optimization of antiarrhythmic drug therapy and reablation if necessary. Effectiveness of the cryoablation procedure versus drug therapy was determined at 12 months. RESULTS: Patients had highly symptomatic AF (78% paroxysmal, 22% early persistent) and experienced failure of at least one antiarrhythmic drug. Cryoablation produced acute isolation of three or more PVs in 98.2% and all four PVs in 97.6% of patients. PVs isolation was achieved with the balloon catheter alone in 83%. At 12 months, treatment success was 69.9% (114 of 163) of cryoblation patients compared with 7.3% of antiarrhythmic drug patients (absolute difference, 62.6% [p < 0.001]). Sixty-five (79%) drug-treated patients crossed over to cryoablation during 12 months of study follow-up due to recurrent, symptomatic AF, constituting drug treatment failure. There were 7 of the resulting 228 cryoablated patients (3.1%) with a >75% reduction in PV area during 12 months of follow-up. Twenty-nine of 259 procedures (11.2%) were associated with phrenic nerve palsy as determined by radiographic screening; 25 of these had resolved by 12 months. Cryoablation patients had significantly improved symptoms at 12 months. CONCLUSIONS: The STOP AF trial demonstrated that cryoballoon ablation is a safe and effective alternative to antiarrhythmic medication for the treatment of patients with symptomatic paroxysmal AF, for whom at least one antiarrhythmic drug has failed, with risks within accepted standards for ablation therapy. (A Clinical Study of the Arctic Front Cryoablation Balloon for the Treatment of Paroxysmal Atrial Fibrillation [Stop AF]; NCT00523978).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Adulto , Idoso , Fibrilação Atrial/tratamento farmacológico , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Estudos Prospectivos , Resultado do Tratamento
20.
Can J Cardiol ; 28(2): 184-90, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22217936

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation (PVI) has emerged as an effective therapy for paroxysmal atrial fibrillation (AF). However, AF recurs in up to 50% of patients, generally because of recovery of PV conduction. Adenosine given during the initial procedure may reveal dormant PV conduction, thereby identifying the need for additional ablation, leading to improved outcomes. The Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE) study is a prospective multicentre randomized trial assessing the impact of adenosine-guided PVI in preventing AF recurrences. METHODS: Patients undergoing a first PVI procedure for paroxysmal AF will be recruited. After standard PVI is completed, all patients will receive intravenous adenosine in an attempt to unmask dormant conduction. If dormant conduction is elicited, patients will be randomized to no further ablation (control group) or additional adenosine-guided ablation until dormant conduction is abolished. If no dormant conduction is revealed, randomly selected patients will be followed in a registry. The primary outcome is time to first documented symptomatic AF recurrence. Assuming that dormant conduction is present in 50% of patients post PVI and symptomatic AF recurs in 45% of controls, 244 patients with dormant conduction will be required to obtain > 90% power to detect a difference of 20%. Thus, a total of 488 patients will be enrolled and followed for 12 months. CONCLUSION: The ADVICE trial will assess whether a PVI strategy incorporating elimination of dormant conduction unmasked by intravenous adenosine will decrease the rate of recurrent symptomatic AF compared with standard PVI.


Assuntos
Adenosina/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Veias Pulmonares/cirurgia , Fibrilação Atrial/prevenção & controle , Humanos , Estudos Prospectivos , Projetos de Pesquisa , Prevenção Secundária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA