Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Robot Surg ; 17(5): 2059-2064, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37191820

RESUMO

Operating room (OR) turnover time (TOT) is the time it takes to prepare an OR for the next surgery after the previous one has been completed. Reducing OR TOT can improve the efficiency of the OR, reduce costs, and improve surgeons' and patients' satisfaction. The objective of this study is to evaluate the effectiveness of an operating room (OR) turnover time (TOT) reduction initiative using the Lean Six Sigma methodology (DMAIC) in the bariatric and thoracic service lines. Performance improvement strategies consist of simplifying steps (surgical tray optimization) and concurrent steps (parallel task execution). We compared 2-month pre-implementation vs. post-implementation. A paired t-test was used to assess whether the difference in the measurements was statistically significant. The study found that TOT was reduced by 15.6% from an average of 35.6 ± 8.1 to minutes 30.09 ± 9.7 min (p < 0.05). Specifically, in the bariatric service line, TOT was reduced by 17.15% and in the thoracic service line, TOT was reduced by 9.6%. No adverse events related to the initiative were reported. The results of this study indicate that the TOT reduction initiative was effective in reducing TOT. The efficient use of operating rooms is crucial in hospital management, as it not only impacts finances but also affects the satisfaction of surgical teams and patients. This study shows the effectiveness of Lean Six Sigma methodology in reducing TOT and improving the efficiency in the OR.


Assuntos
Eficiência Organizacional , Procedimentos Cirúrgicos Robóticos , Humanos , Gestão da Qualidade Total , Procedimentos Cirúrgicos Robóticos/métodos , Eficiência , Custos e Análise de Custo , Melhoria de Qualidade
2.
J Robot Surg ; 17(4): 1531-1534, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36881343

RESUMO

Robotic-assisted surgery has been shown to offer significant benefits for both patients and surgeons. However, the high cost of the equipment remains a major barrier to its widespread adoption in the medical field. To ensure cost-effectiveness of these procedures, it is important to implement strategies that can help reduce the costs involved. One potential strategy to reduce costs is to compare the performance of different generators used in these procedures. In this study, we compared the performance of two generators: the E100 (Intuitive Surgical, Inc.) and the ERBE VIO dV 2.0 (Elektromedizin GmbH). The analysis focused on several key metrics, including the number of times the generators were activated, the average time per seal, total sealing time, and console time. The financial impact of transitioning to the E100 was also evaluated based on annual volume. We analyzed a total of 1457 sleeve gastrectomies, with 746 performed using the ERBE generator and 711 performed using the E100. There were no significant differences in preoperative BMI or bleeding complication rates between the two groups. The average activation of the generator per case was similar in both groups. However, the sealing time was 42.3% lower, and the average console time was 8 min shorter in cases where the E100 was used. Based on our financial analysis, transitioning to the E100 generator would result in cost savings of approximately $33-$34 K per year. This suggests that introducing the new generator is a successful strategy for reducing costs associated with robotic-assisted procedures.


Assuntos
Laparoscopia , Obesidade Mórbida , Procedimentos Cirúrgicos Robóticos , Cirurgiões , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Gastrectomia/métodos , Laparoscopia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA