Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38797374

RESUMO

The Airway section of the Spanish Society of Anesthesiology, Reanimation and Pain Therapy (SEDAR), Spanish Society of Emergency and Emergency Medicine (SEMES) and Spanish Society of Otolaryngology, Head and Neck Surgery (SEORL-CCC) present the Guidelines for the integral management of difficult airway in adult patients. This document provides recommendations based on current scientific evidence, theoretical-educational tools and implementation tools, mainly cognitive aids, applicable to the treatment of the airway in the field of anesthesiology, critical care, emergencies and prehospital medicine. Its principles are focused on the human factors, cognitive processes for decision-making in critical situations and optimization in the progression of the application of strategies to preserve adequate alveolar oxygenation in order to improve safety and quality of care.

2.
Expert Rev Med Devices ; 21(5): 427-438, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38655581

RESUMO

INTRODUCTION: This systematic review and meta-analysis aimed to compare the efficacy of dynamic versus standard bougies to achieve tracheal intubation. METHODS: We searched MEDLINE, Embase, CENTRAL, Web of Science, Scopus and Google Scholar on 10 October 2023. We included clinical trials comparing both devices. The primary outcome was the first-attempt intubation success rate. The secondary outcome was the time required for tracheal intubation. RESULTS: Eighteen studies were included. Dynamic bougies do not increase first-attempt success rate (RR 1.11; p = 0.06) or shorten tracheal intubation time (MD -0.30 sec; p = 0.84) in clinical trials in humans. In difficult airways, first-attempt success intubation rate was greater for dynamic bougies (RR 1.17; p = 0.002); Additionally, they reduced the time required for intubation (MD -4.80 sec; p = 0.001). First-attempt intubation success rate was higher (RR 1.15; p = 0.01) and time to achieve intubation was shorter when using Macintosh blades combined with dynamic bougies (MD -5.38 sec; p < 0.00001). Heterogeneity was high. CONCLUSION: Dynamic bougies do not increase the overall first-pass success rate or shorten tracheal intubation time. However, dynamic bougies seem to improve first-attempt tracheal intubation rate in patients with difficult airways and in those intubated with a Macintosh blade. Further research is needed for definitive conclusions. REGISTRATION OF PROSPERO: CRD42023472122.


Assuntos
Intubação Intratraqueal , Laringoscopia , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Humanos , Laringoscopia/instrumentação , Laringoscopia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA