Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38830049

RESUMO

OBJECTIVES: Predictors and evaluations of continuous flow left ventricular assist device (cf-LVAD) explantation in recovered patients remain under discussion due to lack of evidence on long-term safety and efficacy. This study summarized our experiences regarding cf-LVAD explantation in non-ischaemic dilated cardiomyopathy patients and estimated a predictor for sufficient myocardial recovery allowing left ventricular assist device explant. METHODS: We retrospectively identified 135 adult patients with cf-LVAD therapy as bridge to heart transplant due to non-ischaemic dilated cardiomyopathy. Of those, 13 patients underwent device explantation (recovery group) after myocardial recovery. Twelve (92%) of the explanted patients were evaluated using our weaning protocol and underwent surgical explantation. Meanwhile, the remaining 122 continued with cf-LVAD therapy (non-recovery group). RESULTS: Multivariate logistic regression analysis revealed time interval between the first heart failure event and cf-LVAD implantation as an independent predictor for successful explantation. The optimal time interval cutoff value to predict cf-LVAD explantation was 7 months, with a sensitivity of 91.0% and specificity of 84.6%. Echocardiography in patients with successful cf-LVAD explantation showed significant improvement of left ventricular function and dimensions at 6 months postoperatively. The 13 explanted patients are currently alive at a median of 30 (interquartile range; 18-58) months after explantation. The survival rate free from rehospitalization due to heart failure following explantation was 100%. Left ventricular function and remodelling after explantation were also preserved. CONCLUSIONS: In non-ischaemic dilated cardiomyopathy patients with a short interval between the first heart failure event and cf-LVAD therapy, left ventricular myocardium may recover in an early phase after device implantation.

2.
Kyobu Geka ; 77(5): 345-350, 2024 May.
Artigo em Japonês | MEDLINE | ID: mdl-38720602

RESUMO

Aortic coarctation is diagnosed in approximately 5% of adult patients with congenital heart disease and is commonly diagnosed through the close examination of hypertension. Various surgical strategies for adult coarctation have been recently reported. Generally, aortic replacement may require blood transfusion in case of injury of the well-developed collateral vessels. Therefore, in order to secure an operative safety, we preoperatively used a medical image viewer to identify the abnormal vessels by three-dimensional computer graphics (3DCG) reconstruction. A 34-year-old male patient was referred to our hospital with hypertension and low ankle-brachial pressure index( ABI). Chest computed tomography( CT) scan showed aortic coarctation and development of abnormal collateral vessels. Descending aorta was replaced via a left third-fourth intercostal thoracotomy under partial extracorporeal circulation. As the image viewer depicted, anatomical abnormality of the collateral vessels was identified precisely, and surgically treated without any injury. The patient was discharged 10 days postoperatively without transfusion and with a normalized ABI.


Assuntos
Aorta Torácica , Coartação Aórtica , Imageamento Tridimensional , Humanos , Coartação Aórtica/cirurgia , Coartação Aórtica/diagnóstico por imagem , Masculino , Adulto , Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Tomografia Computadorizada por Raios X
3.
Gen Thorac Cardiovasc Surg ; 72(7): 455-465, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38180694

RESUMO

OBJECTIVES: To evaluate the influence of prolonged cardiopulmonary resuscitation (CPR) on outcomes in heart transplantation with higher risk donor hearts (HRDHs). METHODS: Patients transplanted in our hospital between May 2006 and December 2019 were divided into 2 groups, HRDH recipients and non HRDH recipients. HRDH was defined as meeting at least one of the following criteria: (1) donor left ventricular ejection fraction ≤ 50%, (2) donor-recipient predicted heart mass ratio < 0.8 or > 1.2, (3) donor age ≥ 55 years, (4) ischemic time > 4 h and (5) catecholamine index > 20. Recipients of HRDHs were divided into 3 groups according to the time of CPR (Group1: non-CPR, Group 2: less than 30 min-CPR, and Group 3: longer than 30 min CPR). RESULTS: A total of 125 recipients were enrolled in this study, composing of HRDH recipients (n = 97, 78%) and non HRDH recipients (n = 28, 22%). Overall survival and the rate of freedom from cardiac events at 10 years after heart transplantation were comparable between two groups. Of 97 HRDH recipients, 54 (56%) without CPR, 22 (23%) with CPR < 30 min, and 21 (22%) with CPR ≥ 30 min were identified. One-year survival rates were not significantly different among three groups. The 1-year rate of freedom from cardiac events was not also statistically different, excluding the patients with coronary artery disease found in early postoperative period, which was thought to be donor-transmitted disease. Multivariate logistics regression for cardiac events identified that the CPR duration was not a risk factor even in HRDH-recipients. CONCLUSION: The CPR duration did not affect the outcomes after heart transplantation in HRDH recipients.


Assuntos
Reanimação Cardiopulmonar , Transplante de Coração , Doadores de Tecidos , Humanos , Transplante de Coração/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto , Estudos Retrospectivos , Fatores de Risco , Medição de Risco , Resultado do Tratamento , Idoso
4.
Clin Transplant ; 37(12): e15107, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37615650

RESUMO

AIM: We investigated the effects of pre-transplantation renal dysfunction under left ventricular assisted device (LVAD) support on post-transplantation cardiac function, and patient prognosis after heart transplantation (HTx). METHOD: All patients who were bridged by LVAD and underwent HTx at our hospital between 2007 and 2022 were included in this study. Patients were classified into two groups based on estimated glomerular filtration rate (eGFR) before HTx: renal dysfunction (RD) group (eGFR < 60 mL/min/1.73 m2 ) and non-renal dysfunction (NRD) group. RESULT: A total of 132 patients were analyzed, of whom 48 were classified into the RD group and 84 into the NRD group (RD group, 47.9 ± 10.1 years; NRD group, 38.4 ± 11.9 years, p < .0001). Under LVAD support before HTx, the RD group tended to have a history of right ventricular failure (RD group, nine (19%); NRD group, seven (8%); p = .098). After HTx, the echocardiographic parameters did not differ between the two groups in the long term. Furthermore, more concise hemodynamic parameters, exemplified by right heart catheterization, were not significantly different between the two groups. Regarding graft rejection, no significant differences were found in acute cellular rejection and cardiac allograft vasculopathy following HTx. In contrast, patients with RD before HTx had significantly increased mortality in the chronic phase after HTx and initiation of maintenance dialysis, without any overt changes in cardiac function. CONCLUSION: Pre-transplantation renal dysfunction under LVAD support significantly affected clinical course after HTx without any overt changes in graft cardiac function.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Nefropatias , Humanos , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Transplante de Coração/efeitos adversos , Rim
5.
Gen Thorac Cardiovasc Surg ; 71(8): 480-486, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36810746

RESUMO

OBJECTIVES: This study aimed to report the clinical outcomes of continuous flow left ventricular assist device implantation in end-stage chronic heart failure patients with a history of surgical left ventricular restoration. METHODS: We retrospectively identified 190 patients undergoing continuous flow left ventricular assist device implantation at our center from November 2007 to April 2020. In total, six patients underwent continuous flow left ventricular assist device implantation after various types of surgical left ventricular restoration procedures, including endoventricular circular patch plasty (n = 3), posterior restoration procedure (n = 2), and septal anterior ventricular exclusion (n = 1). RESULTS: Continuous flow left ventricular assist device (Jarvik 2000, n = 2; EVAHEART, n = 1; HeartMate II, n = 1; DuraHeart, n = 1; HVAD, n = 1) was successfully implanted in all patients. During a median follow-up of 48 months (interquartile range, 39-60 months; censoring heart transplantation), no death was documented, which means that overall survival after left ventricular assist device implantation was 100% at any time point. Finally, three patients received heart transplantation (waiting time: 39, 56, and 61 months, respectively) and the other three patients are still awaiting heart transplantation (waiting time: 12, 41, and 76 months, respectively). CONCLUSIONS: In our series, continuous flow left ventricular assist device implantation after surgical left ventricular restoration was safe and feasible, even if an endoventricular patch was used, and effective for bridge to transplant strategy.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Estudos Retrospectivos , Ventrículos do Coração/cirurgia , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento
6.
Gen Thorac Cardiovasc Surg ; 71(6): 347-353, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36348232

RESUMO

OBJECTIVE: In muscular dystrophies (MD) patients with end-stage heart failure (HF), continuous flow left ventricular assist device (cf-LVAD) therapy is still controversial due to a progressive nature of MD-associated muscle weakness. METHODS: All the MD patients who had cf- VAD implants between March 2013 and August 2019 in our hospital were retrospectively studied. Study end points were death, major LVAD-associated complications or respiratory dysfunction caused by muscular weakness. RESULTS: A total of 11 MD patients (Becker type: n = 6; Emery-Dreifuss Myodystrophy: n = 2; Fukuyama subtype: n = 1; Limb-girdle 1B: n = 2) were enrolled. DEMOGRAPHICS: median age 41 years (IQR; 29-47); median Japanese Registry for Mechanically Assisted Circulatory Support: level 3 (2-3); a median interval between MD diagnosis and LVAD implantation 9 years (6-18). The pulmonary function test at LVAD implantation showed a median of %VC; 62% (45-82), FEV1%, 82% (81-88). Survival to discharge was 100% without pulmonary complication and early VAD-related complications. During a median follow-up of 38 months (27-53), re-admissions were needed due to device infection (n = 2), cerebrovascular accidents (disabling, n = 2 and non-disabling, n = 2), ventricular tachycardia (n = 4), and right HF (n = 3), respectively. 7 patients received successful heart transplant after a median waiting time of 44 months (34-61); 3 patients are still on the waiting list (waiting time: 21, 38, and 39 months). One patient died of right HF 15 months after VAD implantation. No one had overt pulmonary dysfunction during LVAD support. CONCLUSION: In selected MD patients with end-stage HF, cf-LVAD therapy is a viable therapeutic option as bridge to heart transplant.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Distrofias Musculares , Humanos , Adulto , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Transplante de Coração/efeitos adversos , Insuficiência Cardíaca/cirurgia , Distrofias Musculares/complicações , Distrofias Musculares/terapia
7.
Artigo em Inglês | MEDLINE | ID: mdl-36088142

RESUMO

OBJECTIVES: Degeneration of mitral prostheses/rings may be treated by redo surgery, and, recently, by transcatheter valve-in-valve/ring implantation. This multicenter registry presents results of transcatheter valve-in-valve and repeat surgery for prostheses/rings degeneration. METHODS: Data provided by 10 German heart centers underwent propensity score-matched retrospective analysis. The primary endpoint was 30-day/midterm mortality. Perioperative outcome was assessed according to the Mitral Valve Academic Research Consortium criteria. Further, the influence of moderate or greater tricuspid regurgitation (TR) on 30-day/midterm mortality was analyzed. RESULTS: Between 2014 and 2019, 273 patients (79 transcatheter mitral valve-in-valve [TM-ViV] and 194 redo mitral valve replacement [Re-MVR]) underwent repeat procedure for mitral prosthesis/ring degeneration. Propensity score matching distinguished 79 patient pairs. European System for Cardiac Operative Risk Evaluation (EuroSCORE) II-predicted risk was 15.7 ± 13.7% in the TM-ViV group and 15.0% ± 12.7% in the Re-MVR group (P = .5336). TM-ViV patients were older (74.73 vs 72.2 years; P = .0030) and had higher incidence of atrial fibrillation (54 vs 40 patients; P = .0233). Severe TR incidence was similar (17.95% in TM-ViV vs 14.10%; P = .1741). Sixty-eight TM-ViV patients previously underwent mitral valve replacement, whereas 41 Re-MVR patients underwent valve repair (P < .0001). Stenosis was the leading degeneration mechanism in 42 TM-ViV versus 22 Re-MVR patients (P < .0005). The 30-day/midterm mortality did not differ between groups. Moderate or greater TR was a predictor of total (odds ratio [OR], 4.36; P = .0011), 30-day (OR, 3.76; P = .0180), and midterm mortality (OR, 4.30; P = .0378), irrespective of group. CONCLUSIONS: In both groups, observed mortality was less than predicted. Redo surgery enabled treatment of concomitant conditions, such as atrial fibrillation or TR. TR was shown to be a predictor of total, 30-day, and midterm mortality in both groups.

8.
ESC Heart Fail ; 9(4): 2491-2499, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35535672

RESUMO

AIMS: The removal of left ventricular assist device (LVAD) after myocardial recovery can provide survival benefits with freedom from LVAD-associated complications. However, in the absence of standardization, the weaning evaluation and surgical strategy differ widely among centres. Therefore, we analysed the experiences of LVAD explantation with our protocol in dilated cardiomyopathy (DCM) patients and investigated the validity of our weaning evaluation and surgical strategy from the perspective of optimal long-term survival. METHODS AND RESULTS: All LVAD explantation patients in our institution between May 2012 and May 2020 were enrolled. All patients were evaluated by our three-phase weaning assessment: (i) clinical stability with improved cardiac function under LVAD support; (ii) haemodynamic stability shown by ramp-loading and saline-loading test; (iii) intraoperative pump-off test. Explant surgery involved removal of the whole system including driveline, pump, sewing ring and outflow-graft, and closure of an apical hole. Intra-operative, peri-operative, and post-operative outcomes, including all-cause mortality and LVAD associated major complications, were retrospectively analysed. A total of 12 DCM patients (DuraHeart, n = 2; EVAHEART, n = 2; HeartMate II, n = 6; HeartMate 3, n = 2) had myocardial recovery after a median 10 months [interquartile range (IQR); 6.3-15 months] support and qualified for our LVAD explantation study protocol [median age: 37 y, IQR; 34-41 years; 83% men]. The median left ventricular ejection fraction was 20% (IQR; 12-23%) at LVAD-implantation and 54% (IQR: 45-55%) before LVAD explantation (P < 0.001). There were no perioperative complications and median ICU stay was 4 days (IQR; 2-4 days). All patients were discharged after a median of 24 days (IQR: 17-28 days) postoperatively. No patient suffered from any cardiac event (heart failure hospitalization, re-implantation of LVAD, or heart transplantation) at a median of 40 months (IQR: 17-58 months) follow up. All patients are alive with NYHA functional class 1 with preserved left ventricular function. CONCLUSIONS: The evaluation of LVAD explant candidates by our weaning protocol was safe and effective. In the patients completing our protocol successfully, LVAD explantation is feasible and an excellent long-term cardiac event free-survival seems to be achieved.


Assuntos
Cardiomiopatia Dilatada , Insuficiência Cardíaca , Coração Auxiliar , Adulto , Cardiomiopatia Dilatada/cirurgia , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
9.
Kyobu Geka ; 75(1): 29-35, 2022 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-35249074

RESUMO

The number of heart transplantation in Japan has gradually increased since the revised organ transplantation act became effective in July 2010. The long-term survival after heart transplantation is superior, compared to the survival in Europe and United States of America( USA). However, the number of patients on a waiting list is rapidly increasing due to an extreme donor shortage. Because of stagnating heart transplantation, there is a need for an optimal solution to an insufficient donor organ supply. We have experienced 125 adult heart transplantations with acceptable survival rate of over 90% at five years. On the other hand, an expected waiting period is lengthening to far longer than five years. Here, based on our experience, we describe the "real world" outcomes and mention the future aspect of the patients on the waiting list on ventricular assist device (VAD). Our suggestions are 1) to promote VAD weaning in patients with myocardial recovery, 2) to aggressively utilize marginal donors, and 3) to expand the indication to destination therapy.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adulto , Insuficiência Cardíaca/terapia , Humanos , Taxa de Sobrevida , Estados Unidos , Listas de Espera
10.
Artigo em Inglês | MEDLINE | ID: mdl-35234899

RESUMO

OBJECTIVES: Pump thrombosis remains a major challenge in heart failure patients with left ventricular HeartWare assist device. Current International Society for Heart and Lung Transplantation recommendations favour surgical pump exchange over lysis because safety and efficacy of lysis has been controversially reported. This study summarizes our experience on our HeartWare thrombosis prevention strategy as well as thrombolysis through implementation of our institutional standardized HeartWare assist device protocol. METHODS: Outcomes of all HeartWare thrombosis patients admitted between 2010 and 2020 were analysed. Thrombolysis therapy using tissue plasminogen activator was used as the first-line therapy in this study and thrombolysis therapy efficacy was defined as freedom from stroke, bleeding, recurrent HeartWare assist device thrombosis or surgical device exchange within 30 days after lysis application. RESULTS: A total of 507 patients have been included in this study and 66 patients (13%) collectively developed a first HeartWare-thrombosis after a median of 12 months (8-22 months) after HeartWare implantation. Forty patients were treated with unstandardized lysis, of whom 7 patients had thrombolysis associated complications, such as incomplete thrombus resolution requiring surgical pump exchange in 4 patients, but also intracranial haemorrhage occurring in 3 patients. Three patients died in the non-protocol group. Eight device thrombosis patients were treated according to our protocol, showing no lysis-associated complication. CONCLUSIONS: Despite current recommendations, preferring surgical HeartWare pump exchange in thrombosis, thrombolysis therapy for first HeartWare thrombosis can be safe and effective in a standardized protocol setting, including anticoagulation adjustment and intensified blood pressure control management.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Terapia Trombolítica , Trombose , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Trombose/tratamento farmacológico , Trombose/terapia , Ativador de Plasminogênio Tecidual/uso terapêutico , Resultado do Tratamento
11.
Heart Vessels ; 37(8): 1462-1469, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35124729

RESUMO

Root infection or dissection involving coronary artery frequently necessitates an emergent Bentall procedure, with low left ventricular ejection fraction (LVEF). In contrast, concerning an elective Bentall for aneurysm, surgeons should balance the risk and benefit of surgery, especially in low LVEF cases. We investigated the association between preoperative LVEF and outcomes after Bentall. We analyzed 98 patients undergoing Bentall between April 2000 and March 2020. The patients were stratified into three groups: (a) 65 with LVEF ≥ 60%, (b) 21 with LVEF 45 to < 60%, and (c) 12 with LVEF < 45%. Baseline characteristics, survivals, and major adverse cardiovascular events (MACE) were compared. To assess potential non-linear relationship between LVEF and mortality, cubic spline analysis was conducted. Median age was similar (a vs b vs c, 52 vs 50 vs 44). In all groups, elective root aneurysm was 50-60%, indicating the rest were complicated and sick. Operative mortality was the highest in group c (4.6% vs 9.5% vs 16.7%, p = 0.294). Survival and MACE-free rate were the worst in group c, though their 10-year survival was 40%. LVEF was an independent risk for mortality, and cubic spline analysis showed potential non-linear association between LVEF and mortality. Although LVEF is an independent predictor of mortality after Bentall, long-term survival was occasionally achieved in low LVEF cases. While surgeons should carefully balance the risk of low LVEF and the benefit of surgery in elective cases, we should perform a non-elective procedure as needed, even if LVEF is low.


Assuntos
Procedimentos Cirúrgicos Eletivos , Função Ventricular Esquerda , Humanos , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento
12.
Interact Cardiovasc Thorac Surg ; 33(6): 857-865, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34333605

RESUMO

OBJECTIVES: Recent data suggested that off-pump coronary artery bypass (OPCAB) may carry a higher risk for mortality in the long term when compared to on-pump coronary artery bypass (ONCAB). We, therefore, compared long-term survival and morbidity in patients undergoing ONCAB versus OPCAB in a large single-centre cohort. METHODS: A total of 8981 patients undergoing isolated elective/urgent coronary artery bypass grafting between January 2009 and December 2019 were analysed. Patients were stratified into 2 groups (OPCAB n = 6649/ONCAB n = 2332). The primary end point was all-cause mortality. Secondary endpoints included repeat revascularization, stroke and myocardial infarction. To adjust for potential selection bias, 1:1 nearest neighbour propensity score (PS) matching was performed resulting in 1857 matched pairs. Moreover, sensitivity analysis was applied in the entire study cohort using multivariable- and PS-adjusted Cox regression analysis. RESULTS: In the PS-matched cohort, 10-year mortality was similar between study groups [OPCAB 36.4% vs ONCAB 35.8%: hazard ratio (HR) 0.99, 95% confidence interval (CI) 0.87-1.12; P = 0.84]. While 10-year outcomes of secondary endpoints did not differ significantly, risk of stroke (OPCAB 1.50% vs ONCAB 2.8%: HR 0.51, 95% CI 0.32-0.83; P = 0.006) and mortality (OPCAB 3.1% vs ONCAB 4.8%: HR 0.65, 95% CI 0.47-0.91; P = 0.011) at 1 year was lower in the OPCAB group. In the multivariable- and the PS-adjusted model, mortality at 10 years was not significantly different (OPCAB 34.1% vs ONCAB 35.7%: HR 0.97, 95% CI 0.87-1.08; P = 0.59 and HR 1.01, 95% CI 0.90-1.13; P = 0.91, respectively). CONCLUSIONS: Data do not provide evidence that elective/urgent OPCAB is associated with significantly higher risks of mortality, repeat revascularization, or myocardial infarction during late follow-up when compared to ONCAB. Patients undergoing OPCAB may benefit from reduced risks of stroke and mortality within the first year postoperatively.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Doença da Artéria Coronariana , Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Doença da Artéria Coronariana/cirurgia , Humanos , Pontuação de Propensão , Resultado do Tratamento
13.
Artif Organs ; 45(5): 473-478, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33141976

RESUMO

Effects of cranioplasty (CP) and skullcap reimplantation after decompressive craniectomy (DC) for cerebral hemorrhage or malignant brain infarction in patients with left ventricular assist device (LVAD) support as bridge to transplantation has not been surveyed yet. The aim of this study was to evaluate outcome and management after CP when aiming for transplantation. Data were collected from our prospective institutional database including all patients undergoing LVAD implantation between 2010 and 2019. Six patients needed CP procedures and were included. Our analysis focused on postoperative outcome, survival, and facilitation of heart transplantation. Study endpoints included also all-cause mortality. From a total of 1010 LVAD implantations during analysis period in our center, six bridge-to-transplantation LVAD patients [median age at LVAD implantation: 32.5 years (IQR: 24.8-39.5 years); four male, HVAD, n = 3; HM II, n = 1; HM 3, n = 2] underwent CP with imminent entrapment secondary to cerebral hemorrhage or malignant infarction. Primary heart failure etiology was myocarditis (n = 2), dilated (n = 2), or ischemic (n = 2). Median INTERMACS class was 1.5 (IQR; 1.0-2.8). Median time on LVAD support to DC procedure was 33 months (IQR: 16-48 months). The indication for DC was intraparenchymal hemorrhage (n = 4), subdural hematoma (n = 1), and malignant middle cerebral artery infarction (n = 1). After a median time of 4 months (IQR: 3.3-4.0 months, range; 2.0-10 months) post DC procedure, CP was subsequently performed without profound neurologic disabilities in all patients. After median time of 26 months (IQR: 21-42 months) follow-up, three patients successfully received heart transplantation, one patient could undergo LVAD explantation for myocardial recovery, and the remaining two patients are still on the list awaiting heart transplantation. CP procedure with skullcap reimplantation is feasible and can be safely performed in LVAD patients, which subsequently may even be eligible for heart transplantation with beneficial prognosis.


Assuntos
Craniectomia Descompressiva/efeitos adversos , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar/efeitos adversos , Hemorragias Intracranianas/cirurgia , Reimplante , Adolescente , Adulto , Estudos de Viabilidade , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Hemorragias Intracranianas/etiologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Crânio/cirurgia , Resultado do Tratamento , Adulto Jovem
14.
Eur J Cardiothorac Surg ; 59(4): 855-862, 2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-33367693

RESUMO

OBJECTIVES: Myocardial recovery is a rare phenomenon in left ventricular assist device (LVAD) therapy. Surgical LVAD removal is associated with the risk of cardiac failure, and the individual evaluation of sufficient myocardial recovery is crucial. Thus, complete device explantation is not consistently performed to minimize perioperative risk. However, the remaining ventricular assist device components bear significant risks of infection or thrombosis. Therefore, we developed this study to evaluate a complete LVAD explantation protocol. METHODS: All patients in our institution who had an LVAD explanted were enrolled in the study. Explant surgery involved removal of the driveline, pump housing, sewing ring and outflow graft. The ventricular wall was reconstructed by double patch plasty. Our analysis focused on surgical and postoperative outcome parameters, including all-cause mortality and major adverse cardiac and cerebrovascular events. RESULTS: A total of 12 patients (HVAD, n = 5; HeartMate II, n = 3; HeartMate 3, n = 4) had myocardial recovery and qualified for our LVAD explantation study protocol [median age: 40 years, interquartile range (IQR) 33-52 years; 50% men]. Primary heart failure aetiology: myocarditis (n = 5), dilated cardiomyopathy (n = 4), toxic cardiomyopathy (n = 2) and valvular heart failure (n = 1). The median average duration on LVAD was 10 months (25-75%: IQR 8.5-30 months). The median left ventricular ejection fraction was 15% (IQR 13-18%) at LVAD implantation and 50% (IQR 45-50%) before LVAD explantation (P = 0.0025).The 30-day survival was 100%. The 1-year survival was 91.7%. All patients were discharged after a median 13 days (IQR 10-18 days) postoperatively. No patient had major adverse cardiac and cerebrovascular events. The New York Heart Association functional class remained consistent during the follow-up period (median New York Heart Association functional class: II, IQR II-II class) including preservation of ventricular function. CONCLUSIONS: Complete LVAD explantation with ventricular patch plasty is feasible and has consistent long-term results.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Remoção de Dispositivo/efeitos adversos , Feminino , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
15.
Gen Thorac Cardiovasc Surg ; 69(5): 803-810, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33118111

RESUMO

OBJECTIVES: Optimal treatment for residual mitral regurgitation (MR) after MitraClip failure is not clearly defined. We report our clinical experience and discuss treatment options. METHODS: Between January 2013 and January 2018, 37 patients (75 ± 8.9 years, 46% male) were admitted for symptomatic MR (grade 3.1 ± 0.47) diagnosed after previous MitraClip therapy. Clinical outcome of these patients, who underwent medical therapy alone (n = 8, M-group), repeat MitraClip therapy (n = 8, reMC group), or mitral valve surgery (n = 21, S-group) for residual MR, were retrospectively analyzed. RESULTS: Thirty-day survival was 88% (M-group), 100% (reMC-group), and 76% (S-group). The rate of discharge to home was 88% in the reMC-group, better than 38% in the M-group (p = 0.051) and 19% in the S-group (p < 0.001). Perioperative non-survivors in the S-group had high surgical risk with median logistic EuroSCORE of 64.6% (interquartile range 57.4%-87.0%); all died from low cardiac output syndrome or multiple organ failure. The main MR pathologies resulted from leaflet tear and tethering in the M-group, tethering in the reMC-group, and degenerative valve and leaflet tear in the S-group. Kaplan-Meier analysis of overall survival at 1 year showed better outcome for patients in the reMC-group (50%, 95% CI 15.2-77.5%) and S-group (47.6%, 95% CI 25.7-66.7%), as compared to those in the M-group (12.5%, 95% CI 0.70-42.3%) (log-rank test p = 0.108 and p = 0.167, respectively). CONCLUSION: Medical therapy alone after failed MitraClip therapy resulted in poor 1-year prognosis. In patients without extremely high surgical risk, repeat MitraClip therapy, or surgical revision MIGHT BE CONSIDERED depending on valve pathology and cardiac comorbidities.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
16.
Artigo em Inglês | MEDLINE | ID: mdl-33226086

RESUMO

OBJECTIVES: Clinical experience with continuous flow ventricular assist devices (VADs) in patients with transposition of the great arteries (TGA) including dextro-TGA and congenitally corrected TGA is rare, and indications as well as potential benefits or specific hurdles remain unclear. Therefore, our goal was to report on our experience regarding VAD therapy in adult patients with TGA as a bridge to candidacy. METHODS: We performed a single-centre retrospective study of all adult patients with TGA with systemic right ventricular failure who had continuous flow VAD implants between 2010 and 2018. Study end points were all causes of death, major cardiac and cerebrovascular adverse events or pump thrombosis. Follow-up continued until the time of the heart transplant. RESULTS: A total of 6 patients (4 men) had a continuous flow VAD implanted in the context of a failing systemic right ventricle (dextro-TGA after the Mustard procedure: n = 3; congenitally corrected TGA: n = 3). Demographics: mean age 32 ± 5.7 years; median Interagency Registry for Mechanically Assisted Circulatory Support: level II (range 1-4), mean pulmonary artery 48 ± 13 mmHg, mean pulmonary vascular resistance 5.6 ± 3.5 Wood units. Postoperative data: intensive care unit stay: 16 ± 9.7 days; in-hospital survival: 100%; no early VAD-related complications occurred. Mean follow-up: 33 ± 18 months; persistent left-side paresis: n = 1; minor (non-disabling) stroke: n = 2. Post-VAD pulmonary artery: 19 ± 3.4 mmHg; P < 0.005; post-VAD pulmonary resistance: 2.2 ± 0.55 Wood units; P = 0.066. Four patients had heart transplants after a mean waiting time of 30 months after the VAD was implanted; 2 patients are still on the waiting list (waiting time: 52 and 24 months). CONCLUSIONS: Continuous flow VAD therapy is a feasible therapeutic option in adult patients with TGA and a failing systemic right ventricle as a bridge to candidacy and a bridge to a heart transplant.

17.
ESC Heart Fail ; 7(4): 1781-1790, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32445540

RESUMO

AIMS: The aim of this study was to compare the outcomes of surgical mitral valve repair or replacement (sMVR) and percutaneous edge-to-edge repair using MitraClip (pMVR) in patients with severe left ventricular dysfunction affected by functional mitral regurgitation (FMR). METHODS AND RESULTS: We retrospectively identified 132 patients with left ventricular ejection fraction (LVEF) â‰¦ 30% submitted to sMVR (n = 47) or pMVR (n = 85) for FMR at our centre from January 2013 to December 2017. To adjust for baseline imbalances, we used a propensity score matching by age, logistic EuroSCORE, and left ventricular end-systolic volume. After being matched, MitraClip therapy showed lower perioperative mortality and rate of complications yet increased residual mitral regurgitation (MR) grade than did surgery (0.2 ± 0.50 in sMVR vs. 1.3 ± 0.88 in pMVR, P < 0.0001). According to stratified multivariate Cox model analysis, residual MR severity was an independent risk factor for cardiac death [hazard ratio (HR), 2.81; 95% confidence interval [CI], 1.44-5.48, P = 0.0025] and re-hospitalization for heart failure (HR, 3.07; 95% CI, 1.50-6.29, P = 0.0022) at 1 year follow-up. Stratified multivariable Cox regression analysis at 3 years identified pMVR as risk factor for cardiac death (HR, 0.19; 95% CI, 0.040-0.86, P = 0.031) and re-hospitalization for heart failure (HR, 0.28; 95% CI, 0.077-0.99, P = 0.048). CONCLUSIONS: In patients with FMR and LVEF ≤ 30%, MitraClip therapy resulted in lower perioperative complications and mortality than sMVR. However, surgically treated patients who survived the perioperative stage had less residual MR and experienced lower rates of re-hospitalization for heart failure at 1 year and lower cardiac mortality at 1 and 3 years of follow-up than did patients undergoing pMVR.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda
18.
Open Heart ; 7(1): e001203, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32201589

RESUMO

Aim: To evaluate the impact of preinterventional moderate-to-severe functional tricuspid regurgitation (FTR) on early outcome after percutaneous edge-to-edge mitral valve repair (pMVR) with MitraClip procedures for functional mitral regurgitation (FMR) in patients with heart failure with reduced ejection fraction (HFrEF). Methods and results: From January 2013 to December 2017, 80 patients with HFrEF (ejection fraction 22%±5.3%) and FMR (grade 3.0±0.36) underwent successful pMVR. The 3-year actuarial survival was 58%. However, 73% (n=22) of non-survivors died of cardiac failure within 1 year. Patients were categorised into none-to-mild (n=36) and moderate-to-severe (n=44) postinterventional FTR groups according to pre-MitraClip tricuspid regurgitation grade. Cox regression analysis on 1-year survival demonstrated an impact of FTR severity (HR=1.8, 95% CI 1.01% to 3.09%, p=0.047), preoperative New York Heart Association class (HR=2.8, 95% CI 1.2% to 6.5%, p=0.015) and peripheral artery disease (HR=5.4, 95% CI 1.6 to 18, p=0.0054). Kaplan-Meier analysis showed that 1-year cardiac death was higher in the moderate-to-severe FTR group (p=0.048). In our study, 77% of pre-MitraClip moderate-to-severe FTR cannot be significantly reduced. Post-MitraClip moderate-to-severe FTR grade was related to lower survival (p<0.001). Conclusion: In patients with HFrEF treated with MitraClip for FMR, moderate-to-severe FTR was an independent predictor of cardiac death within 1 year. To improve survival, additional therapy to residual FTR should be considered in early phase after MitraClip therapy.


Assuntos
Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Volume Sistólico , Insuficiência da Valva Tricúspide/fisiopatologia , Valva Tricúspide/fisiopatologia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade
19.
Interact Cardiovasc Thorac Surg ; 28(1): 164-166, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30032265

RESUMO

A device-related thrombus is a very common complication after the implantation of a Watchman device. Although anticoagulation therapy is the standard first choice therapy for a device-related thrombus, complications related to bleeding or existence of non-responders to the anticoagulation therapy are reported. Therefore, the possibility of another treatment, including surgical repair, needs to be discussed in the population unsuccessfully treated with anticoagulation therapy. We performed device-related thrombus removal and covered the orifice of the left atrial appendage with an autologous pericardial patch in 2 cases involving non-responders to anticoagulation therapy. Herein, we describe the technique and results of our experience with these 2 patients. The covering technique with an autologous pericardial patch is simple but highly efficient in preventing recurrent thrombus formation.


Assuntos
Anticoagulantes/uso terapêutico , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Remoção de Dispositivo/métodos , Cardiopatias/etiologia , Dispositivo para Oclusão Septal/efeitos adversos , Trombose/etiologia , Idoso , Feminino , Cardiopatias/diagnóstico , Cardiopatias/terapia , Humanos , Trombose/diagnóstico , Trombose/terapia
20.
Kyobu Geka ; 69(7): 537-40, 2016 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-27365067

RESUMO

Isolated pulmonary valve endocarditis is an extremely rare clinical condition. Here, we report a case of pulmonary valve endocarditis caused by methicillin-resistant Staphylococcus aureus (MRSA). An 84-year-old man with a history of aortic regurgitation and patent foramen ovale was admitted to our hospital due to fever of unknown origin for 4 weeks' duration. MRSA was detected in his blood cultures. Transthoracic echocardiography demonstrated a mobile vegetation attached to the pulmonary valve, moderate to severe aortic regurgitation, and patent foramen ovale with left-to-right shunt. After 30-days' treatment with vancomycin, gentamicin and rifampicin, he defervesced and blood cultures became negative. At surgery, a large vegetation was still attached to the pulmonary valve, but the leaflets remained with minimum damage. Aortic valve replacement, direct closure of the patent foramen ovale, and simple resection of the vegetation were performed. The postoperative course was uneventful.


Assuntos
Insuficiência da Valva Aórtica/complicações , Endocardite/microbiologia , Forame Oval Patente/complicações , Doenças das Valvas Cardíacas/microbiologia , Staphylococcus aureus Resistente à Meticilina , Valva Pulmonar , Infecções Estafilocócicas , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia , Endocardite/diagnóstico por imagem , Endocardite/cirurgia , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA