Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Vet Surg ; 53(2): 357-366, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37463876

RESUMO

OBJECTIVE: To report the use and feasibility of a self-locking resorbable loop device for cryptorchidectomy. STUDY DESIGN: Clinical prospective study. POPULATION: Twenty horses. METHODS: Horses suspected to have an abdominal testicle/s after admission work-up were enrolled. Horses were anesthetized in dorsal recumbency and a standard laparoscopic technique was performed. The looped device was inserted into the abdomen, glided around the testis/cord and tightened. Then, the spermatic cord was transected prior testis removal. Surgical procedure details and remarks, perioperative complications and total surgical time were recorded. Short- (>3 weeks) and long-term (>6 months) follow-ups were obtained by telephone questionnaire. RESULTS: Median total surgical time was 67 min (range: 43-189 min) and significantly shortened after the first four horses. The loop device was easily glided around 13/20 abdominal testes and required more time and technical skills around larger testes (≥3 years). Excellent intraoperative hemostasis was achieved in 17 horses. Three horses demonstrated mild intraoperative bleeding that required retightening, device replacement or adding a second device, respectively. Three horses developed mild postoperative hemoabdomen identified ultrasonographically and were successfully managed medically. Follow-up revealed no significant complications related to the procedure. One horse was euthanized for colic 4 months after surgery and one died of hemolytic shock 17 months postoperatively. CONCLUSION: This device represents another method to perform equine cryptorchidectomy that requires minimal training and laparoscopic expertise but demands knowledge of the device and application to prevent complications. CLINICAL SIGNIFICANCE: Laparoscopic cryptorchidectomy using this device is an alternative technique for horses <3 years.


Assuntos
Criptorquidismo , Doenças dos Cavalos , Laparoscopia , Masculino , Cavalos/cirurgia , Animais , Criptorquidismo/cirurgia , Criptorquidismo/veterinária , Estudos Prospectivos , Doenças dos Cavalos/cirurgia , Orquiectomia/veterinária , Orquiectomia/métodos , Laparoscopia/veterinária , Laparoscopia/métodos
2.
Acta Vet Scand ; 65(1): 48, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37986118

RESUMO

BACKGROUND: A 3D printed self-locking device made of polydioxanone (PDO) was developed to facilitate a standardized ligation technique. The subcutaneous tissue reaction to the device was evaluated after implantation in ten horses of mixed age, sex and breed and compared to loops of poly(lactic-co-glycolic acid) (PLGA). In two of the horses, the implants were removed before closing the skin. The appearance of the implants and surrounding tissue was followed over time using ultrasonography. Implants were removed after 10 and 27 (± 1) days for histologic examination. RESULTS: On macroscopic inspection at day 10, the PDO-device was fragmented and the surrounding tissue was oedematous. On ultrasonographic examination, the device was seen as a hyperechoic structure with strong acoustic shadowing that could be detected 4 months post-implantation, but not at 7 months. Histology revealed a transient granulomatous inflammation, i.e., a foreign body reaction, which surrounded both PDO and PLGA implants. The type and intensity of the inflammation varied between individuals and tissue category. CONCLUSIONS: The 3D printed PDO-device caused a transient inflammatory reaction in the subcutaneous tissue and complete resorption occurred between 4 and 7 months. Considering the intended use as a ligation device the early fragmentation warrants further adjustments of both material and the 3D printing process before the device can be used in a clinical setting.


Assuntos
Doenças dos Cavalos , Polidioxanona , Animais , Cavalos/cirurgia , Inflamação/veterinária , Ligadura/métodos , Ligadura/veterinária , Impressão Tridimensional , Tela Subcutânea/cirurgia , Masculino , Feminino
3.
Front Vet Sci ; 10: 1250147, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37799403

RESUMO

Introduction: Arthrodesis, performed as a salvage surgical procedure to treat intractable joint conditions in dogs and cats, is associated with a high incidence of complications intra and postoperative, proving the need for improved and new techniques in arthrodesis surgery. Adding a new resorbable bone glue to the arthrodesis could potentially add fixation strength and lower complications. The objectives of this experimental ex vivo biomechanical study were therefore to develop a biomechanical test model of partial tarsal arthrodesis and to determine whether the new resorbable bone glue (phosphoserine modified cement) produced measurable fixation strength in canine calcaneoquartal arthrodesis, without orthopedic implants. Methods: Four biomechanical test models with a total of 35 canine tarsal joints were used. Soft tissues were dissected to 4 different test models with variable contributions from soft tissues. The calcaneoquartal joint was prepared as in vivo arthrodesis and the glue was applied to joint surfaces as a liquid/putty (0.4 cc). After curing for 24 h, a shear force was applied to the joint (1 mm per minute) and the failure strength was recorded. Results: Calcaneoquartal joints, where all soft tissues had been completely resected and fixated with glue (1-1.5 cm2 joint surface), withstood 2-5 mm of displacement and an average of 100 ± 58 N/cm2 of shear force (Model 1). Similar adhesive fixation strengths were obtained in Model 2 and 3 with increasing contributions from soft tissues (80 ± 44 and 63 ± 23 N/cm2, p = 0.39, ANOVA). Conclusion: The developed biomechanical model was sensitive enough to measure differences in fixation strengths between different glue formulations. The average fixation strength (60-100 N/cm2) should be strong enough to support short-term load bearing in medium sized canines (20 kg). The developed cadaver biomechanical test model is of potential use for other arthrodesis studies. The new resorbable glue can potentially contribute to stability at arthrodesis surgery, acting as a complement to today's standard fixation, metal implants.

4.
BMC Vet Res ; 18(1): 242, 2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35751056

RESUMO

BACKGROUND: Canine tonsillectomy is performed due to acute or chronic tonsillitis, neoplasia, trauma or occasionally brachycephalic obstructive airway syndrome. Several tonsillectomy techniques are used but information about surgical complications is scarce. This retrospective study of patient records at the University Animal Hospital aimed to investigate complications related to canine tonsillectomy performed by 20-min clamping combined with monopolar electrosurgery. Inclusion criteria were bilateral tonsillectomy performed with "20-min clamping technique combined with monopolar electrosurgery without suture or ligation". Exclusion criteria were unilateral tonsillectomy, tonsillar neoplasia, additional surgical procedures other than tonsillectomy, cases where sutures were used initially, and cases where unspecified or other methods of tonsillectomy were used. The search of the patient records of the University Animal Hospital included a 10-year period. Complications that required additional anaesthesia were defined as major complications. Minor complications were handled during surgery or after surgery without surgical intervention. RESULTS: Of 39 dogs that fulfilled the inclusion criteria, 11 dogs had complications and out of those 1 dog had two complications. Altogether, of the 12 complications, 2 were classified as major complications and 10 as minor. The most frequent complication was bleeding from the surgical site, in total 11 incidences; 10 dogs had an incidence of bleeding and out of those, 1 dog bled twice, both during and after surgery. Of these 10 dogs that bled, seven incidences of bleeding occurred during surgery and four incidences occurred after surgery. The two dogs with major complications were re-anaesthetized due to bleeding after surgery. No lethal complications occurred and all dogs survived to discharge. CONCLUSIONS: Bleeding during and after surgery was a common complication in dogs after bilateral tonsillectomy using "20-min clamping technique combined with monopolar electrocautery". Revision intervention was often needed, sometimes urgently. Although no comparison was made with another technique, the studied technique should be used with caution.


Assuntos
Doenças do Cão , Tonsilectomia , Tonsilite , Animais , Constrição , Doenças do Cão/cirurgia , Cães , Eletrocirurgia/efeitos adversos , Eletrocirurgia/veterinária , Humanos , Estudos Retrospectivos , Tonsilectomia/efeitos adversos , Tonsilectomia/métodos , Tonsilectomia/veterinária , Tonsilite/cirurgia , Tonsilite/veterinária
5.
BMC Res Notes ; 14(1): 265, 2021 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-34246304

RESUMO

OBJECTIVE: This study aimed to investigate the short-term effect of ovariohysterectomy on urine levels of serotonin and its relation to levels of cortisol, testosterone and progesterone in female dogs. Seven bitches were studied before surgical ovariohysterectomy and then once a week during 4 weeks. Spontaneously voided urine samples were collected and concentration ratios of hormone/creatinine in urine were analysed. RESULTS: The bitches had significantly lower levels of cortisol, testosterone, and progesterone 1 week after ovariohysterectomy compared with before and the levels stayed low throughout the study (P ≤ 0.05). Interestingly, serotonin levels tended to increase 4 weeks after surgery (P = 0.08). A positive correlation between cortisol and progesterone was found before and after surgery. After surgery, serotonin was positively correlated with cortisol and progesterone (P ≤ 0.05).


Assuntos
Progesterona , Testosterona , Animais , Cães , Feminino , Humanos , Hidrocortisona , Histerectomia/veterinária , Serotonina
6.
Vet Surg ; 50 Suppl 1: O32-O39, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33687090

RESUMO

OBJECTIVE: To test the feasibility of a resorbable self-locking device for sealing of lung tissue in lung lobectomy in experimental dogs and dogs with pulmonary mass, and to study its resorption with CT. STUDY DESIGN: Experimental study and clinical case series. ANIMALS: Five beagles in the experimental group; six canine patients with a pulmonary mass in the clinical group. METHODS: In both groups, an intercostal incision into thorax was performed. A resorbable self-locking device, LigaTie, was applied at the hilum of left cranial lobe in the experimental group and the affected lobe in the clinical group. Each lobe was removed by cutting the tissue just distal to the device. Video-assisted thoracic surgery was used in the experimental group; postoperative diagnostic imaging was repeated monthly until the device was not apparent on CT. RESULTS: Application of LigaTie was feasible for lung lobectomy in all dogs. The device enabled en bloc ligation of the hilum of the affected lobe including the pulmonary arteries and veins and lobular bronchus. No air leakage from the resection stump was observed in any dog. Trace of the device on CT images gradually decreased and was undetectable at 4 months postoperatively in experimental dogs. CONCLUSION: This study suggested that the resorbable self-locking device may be used for sealing of airways in complete lung lobectomy. CLINICAL RELEVANCE: The resorbable self-locking device is suggested to be useful for canine lung lobectomy and may facilitate thoracoscopic lung lobectomy. Further investigations on its clinical application in small animal surgery are warranted.


Assuntos
Doenças do Cão , Neoplasias Pulmonares , Pneumonectomia/veterinária , Animais , Doenças do Cão/cirurgia , Cães , Ligadura/veterinária , Pulmão/cirurgia , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/veterinária , Pneumonectomia/instrumentação , Cirurgia Torácica Vídeoassistida/instrumentação , Cirurgia Torácica Vídeoassistida/veterinária
7.
Acta Vet Scand ; 62(1): 43, 2020 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-32758260

RESUMO

BACKGROUND: The protein chromogranin A (CgA) is stored and co-released with catecholamines from the stimulated adrenal glands. Increased plasma concentrations of CgA have been shown in people with heart disease. The aim of the study was to investigate whether plasma concentrations of the CgA-derived biologically active peptides catestatin and vasostatin were associated with the severity of myxomatous mitral valve disease (MMVD) in dogs and to assess potential associations between these blood variables and dog characteristics, echocardiographic variables, heart rate (HR), blood pressure (BP) and plasma N-terminal-proBNP (NT-proBNP) concentration. Sixty-seven privately owned dogs with or without MMVD were included. The dogs underwent physical examination, blood pressure measurement, blood sample collection, and echocardiographic examination. Plasma concentrations of catestatin and vasostatin were analyzed using radioimmunoassay. RESULTS: Catestatin concentration decreased with increasing left atrial and ventricular size (R2 ≤ 0.09, P ≤ 0.019), and increased with increasing systolic and diastolic blood pressures (R2 ≤ 0.08, P ≤ 0.038). Regression analyses showed no significant associations for vasostatin. No differences in plasma concentrations of catestatin or vasostatin were found between the disease severity groups used in the study. CONCLUSIONS: In the present dog population, the catestatin concentration showed weak negative associations with left atrial and ventricular sizes, both of which are known to increase with increasing severity of MMVD. Furthermore, the catestatin concentration showed weak positive associations with blood pressure.


Assuntos
Calreticulina/sangue , Cromogranina A/sangue , Doenças do Cão/sangue , Prolapso da Valva Mitral/veterinária , Fragmentos de Peptídeos/sangue , Animais , Biomarcadores/sangue , Pressão Sanguínea , Cromogranina A/metabolismo , Cães , Ecocardiografia/veterinária , Feminino , Frequência Cardíaca , Masculino , Prolapso da Valva Mitral/sangue , Prolapso da Valva Mitral/etiologia , Peptídeo Natriurético Encefálico/sangue , Suécia
8.
Surg Innov ; 25(2): 158-164, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29298608

RESUMO

The aim of this pilot test was to test a new self-locking resorbable implant for hilum occlusion during a video-assisted thoracoscopic lung lobectomy in a surviving pig model. Once the thoracic cavity was assessed and structures identified, the right middle lobe and its respective hilum were exposed. The implant was introduced with a semiclosed loop through a working channel and positioned around the pulmonary lobe. Occlusion was performed with a conventional Crile forceps and a laparoscopic Kelly forceps. Lobe section was done with laparoscopic Metzenbaum scissors and tissue removal through the dorsal access. No signs of pneumothorax or bleeding were observed during a 60-day follow-up. Necropsy findings showed minimal pleuritis in caudal access and in the lobar stump. A granulomatous formation was found around a dense, amorphous material, which was identified as remains of a small part of the implant. Histopathological findings showed signs of a chronic healing process without other alterations. The resorbable implant LigaTie appears to exhibit similar handling and application characteristics during surgery as nonsurgical tie wraps. The resorbable implant avoids the uncontrolled substances not suitable for implants of conventional ties. The results of this pilot test suggested the resorbable implant's mechanical properties provided effective tissue support to complete the healing of the pulmonary hilum.


Assuntos
Neoplasias Pulmonares/cirurgia , Pulmão/cirurgia , Pneumonectomia/métodos , Cirurgia Torácica Vídeoassistida/métodos , Animais , Desenho de Equipamento , Masculino , Pneumonectomia/instrumentação , Pneumotórax , Hemorragia Pós-Operatória , Próteses e Implantes , Suínos , Cirurgia Torácica Vídeoassistida/instrumentação
9.
Acta Vet Scand ; 58(1): 80, 2016 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-27855712

RESUMO

BACKGROUND: Surgery causes a stress response, a physiologic response to trauma. The intraoperative surgical stress response in dogs diagnosed with pyometra has not previously been described. The aim of this study was to investigate the intraoperative surgical stress response, assessed by blood pressure and heart rate measurements, in dogs diagnosed with pyometra and healthy controls. All dogs were premedicated with acepromazine and methadone, anaesthesia was induced with propofol and maintained with isoflurane, where after the dogs were subjected to ovariohysterectomy. RESULTS: Eight dogs diagnosed with pyometra and eight healthy controls were used. Systolic blood pressure and heart rate were measured to assess the surgical stress response. Additionally propofol dosage at induction of anaesthesia and the end-tidal isoflurane concentration were investigated. The surgery was split into four phases. Phase 0 was the period 10 min before the skin incision, phase 1 was skin incision and opening of abdomen, phase 2 was manipulation of uterine horns, lifting of the ovary with stretching of the mesovarium, ligation and transection of mesovarium and phase 3 was ligation and transection of cervix, removal of organs and closing of the abdomen. Dosage of propofol at induction of anaesthesia was 3.6 ± 1 mg/kg in dogs with pyometra and 4.1 ± 1 in healthy controls (P = 0.37). In both groups, systolic blood pressure increased between phase 1 and 2, from 87 ± 15 to 114 ± 19 mmHg in dogs with pyometra, and from 88 ± 18 to 106 ± 20 mmHg in healthy controls, (both P < 0.0001). Systolic blood pressure did not differ significantly between groups in any of the phases. Heart rate and end-tidal concentration of isoflurane did not differ significantly between phases or between groups. CONCLUSIONS: The increased blood pressure at removal of ovaries during ovariohysterectomy suggests a pronounced noxious stimulus at this part of the procedure. In principle, the study parameters and response to surgery did not differ significantly between dogs with pyometra and healthy controls.


Assuntos
Pressão Sanguínea , Doenças do Cão/cirurgia , Frequência Cardíaca , Histerectomia/veterinária , Ovariectomia/veterinária , Piometra/veterinária , Estresse Fisiológico/fisiologia , Animais , Cães , Feminino , Piometra/cirurgia
10.
SAGE Open Med ; 3: 2050312115576432, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26770773

RESUMO

OBJECTIVES: Biomarkers representing sympathetic tone and the surgical stress response are measured to objectively evaluate surgical techniques and anaesthetic protocols. If a part of the intraoperative procedure is repeated on the contralateral organ, one animal may potentially serve as its own control and, if so, may minimize the problem of individual differences of the stress response to anaesthesia and surgery. This study aimed to investigate the use of chromogranin A for measurement of the intraoperative sympathetic tone. Additional aims were to investigate chromogranin A and cortisol as indicators of the intraoperative surgical stress response caused by repeated noxious stimuli in dogs subjected to ovariohysterectomy and thereby to investigate the possibility of one dog serving as its own control. METHODS: Experiments were carried out on 10 dogs subjected to ovariohysterectomy. Perioperative blood samples (0-6) were collected after premedication, immediately before induction of anaesthesia (0), after induction of anaesthesia and before incision (1), before (2) and after (3) removal of the first ovary, after a 15-min pause before removal of the second ovary (4), after removal of the second ovary (5) and after closing the abdomen (6). Plasma chromogranin A and cortisol were analysed. RESULTS: Plasma chromogranin A did not change. Plasma cortisol concentration did not change between before anaesthesia and opening of the abdomen. Plasma cortisol increased at removal of the first ovary. Cortisol did not change at removal of the second ovary but remained increased compared to initial sample. CONCLUSION: The results suggest chromogranin A is a poor indicator of intraoperative sympathetic tone during elective surgery in dogs. Cortisol measurement was useful for assessment of intraoperative noxious stimuli. However, at these test conditions, neither plasma chromogranin A nor plasma cortisol was useful for assessment of repeated intraoperative noxious stimuli where one dog served as its own control.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA