Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Lancet Infect Dis ; 17(10): 1033-1041, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28711585

RESUMO

BACKGROUND: Since 2013, over 100 cases of Mycobacterium chimaera prosthetic valve endocarditis and disseminated disease were notified in Europe and the USA, linked to contaminated heater-cooler units (HCUs) used during cardiac surgery. We did a molecular epidemiological investigation to establish the source of these patients' disease. METHODS: We included 24 M chimaera isolates from 21 cardiac surgery-related patients in Switzerland, Germany, the Netherlands, and the UK, 218 M chimaera isolates from various types of HCUs in hospitals, from LivaNova (formerly Sorin; London, UK) and Maquet (Rastatt, Germany) brand HCU production sites, and unrelated environmental sources and patients, as well as eight Mycobacterium intracellulare isolates. Isolates were analysed by next-generation whole-genome sequencing using Illumina and Pacific Biosciences technologies, and compared with published M chimaera genomes. FINDINGS: Phylogenetic analysis based on whole-genome sequencing of 250 isolates revealed two major M chimaera groups. Cardiac surgery-related patient isolates were all classified into group 1, in which all, except one, formed a distinct subgroup. This subgroup also comprised isolates from 11 cardiac surgery-related patients reported from the USA, most isolates from LivaNova HCUs, and one from their production site. Isolates from other HCUs and unrelated patients were more widely distributed in the phylogenetic tree. INTERPRETATION: HCU contamination with M chimaera at the LivaNova factory seems a likely source for cardiothoracic surgery-related severe M chimaera infections diagnosed in Switzerland, Germany, the Netherlands, the UK, the USA, and Australia. Protective measures and heightened clinician awareness are essential to guarantee patient safety. FUNDING: Partly funded by the EU Horizon 2020 programme, its FP7 programme, the German Center for Infection Research (DZIF), the Swiss National Science Foundation, the Swiss Federal Office of Public Health, and National Institute of Health Research Oxford Health Protection Research Units on Healthcare Associated Infection and Antimicrobial Resistance.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Infecções por Mycobacterium/epidemiologia , Infecções por Mycobacterium/microbiologia , Mycobacterium/isolamento & purificação , Infecções Relacionadas à Prótese/microbiologia , Contaminação de Equipamentos , Saúde Global , Humanos , Doença Iatrogênica , Mycobacterium/genética , Polimorfismo de Nucleotídeo Único , Infecções Relacionadas à Prótese/epidemiologia
2.
Infect Dis (Lond) ; 49(5): 405-409, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28071193

RESUMO

BACKGROUND: Extended-spectrum ß-lactamase-producing Enterobacteriaceae (ESBL-E) are spreading worldwide in both hospital and community settings. In this study, the molecular epidemiology and the transmission modalities of ESBL-E in intensive care- and bone marrow transplant were investigated. METHODS: All patients included in this study were screened for presence of ESBL-E on admission and weekly. Relevant ß-lactamase genes were identified by PCR and sequencing. RESULTS: A total of 669 patients were included in this study. On admission, ESBL-producing Escherichia coli were detected in 49 (7.3%) patients and ESBL-producing Klebsiella pneumoniae in one patient. The most common ESBL types among E. coli isolates were CTX-M-15 (38.8%) and CTX-M-1 (38.8%). Furthermore, 12 of 49 (24.5%) ESBL-producing E. coli could be assigned to the epidemic clone ST131. A single patient acquired ESBL-producing E. coli during the hospital stay but cross-transmission could not be demonstrated. Among 1095 environmental samples none revealed ESBL. CONCLUSIONS: Our results suggest that early detection of ESBL-producing Enterobacteriaceae and consequent implementation of basic hygiene measures and contact isolation may reduce the transmission rate during the hospital stay.


Assuntos
Infecção Hospitalar/epidemiologia , Infecções por Enterobacteriaceae/epidemiologia , Escherichia coli/isolamento & purificação , Klebsiella pneumoniae/isolamento & purificação , beta-Lactamases/metabolismo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecção Hospitalar/transmissão , Infecções por Enterobacteriaceae/transmissão , Escherichia coli/classificação , Escherichia coli/enzimologia , Escherichia coli/genética , Feminino , Genótipo , Humanos , Unidades de Terapia Intensiva , Klebsiella pneumoniae/classificação , Klebsiella pneumoniae/enzimologia , Klebsiella pneumoniae/genética , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Epidemiologia Molecular , Tipagem Molecular , Reação em Cadeia da Polimerase , Estudos Prospectivos , Análise de Sequência de DNA , Adulto Jovem , beta-Lactamases/genética
3.
Euro Surveill ; 21(17)2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-27168588

RESUMO

Invasive infections with Mycobacterium chimaera were reported in patients with previous open chest surgery and exposure to contaminated heater-cooler units (HCUs). We present results of the surveillance of clinical cases and of contaminated HCUs as well as environmental investigations in Germany up until February 2016. Clinical infections occurred in five male German cases over 50 years of age (range 53-80). Cases had been exposed to HCUs from one single manufacturer during open chest surgery up to five years prior to onset of symptoms. During environmental investigations, M. chimaera was detected in samples from used HCUs from three different countries and samples from new HCUs as well as in the environment at the manufacturing site of one manufacturer in Germany. Our investigation suggests that at least some of the M. chimaera infections may have been caused by contamination of HCUs at manufacturing site. We recommend that until sustainable measures for safe use of HCUs in operation theatres are implemented, users continue to adhere to instructions for use of HCUs and Field Safety Notices issued by the manufacturer, implement local monitoring for bacterial contamination and continuously check the websites of national and European authorities for current recommendations for the safe operation of HCUs.


Assuntos
Contaminação de Equipamentos/estatística & dados numéricos , Circulação Extracorpórea/instrumentação , Infecções por Mycobacterium/microbiologia , Miocardite/microbiologia , Infecção da Ferida Cirúrgica/microbiologia , Vasculite/microbiologia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/instrumentação , Comorbidade , Surtos de Doenças/estatística & dados numéricos , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Mycobacterium/isolamento & purificação , Infecções por Mycobacterium/epidemiologia , Miocardite/epidemiologia , Vigilância da População , Prevalência , Infecção da Ferida Cirúrgica/epidemiologia , Vasculite/epidemiologia
4.
Int J Hyg Environ Health ; 217(2-3): 145-54, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24100053

RESUMO

Bioaerosols from cooling towers are often suspected to cause community-acquired legionellosis outbreaks. Although Legionella infections can mostly be assigned to the emission sources, uncertainty exists about the release and distribution into the air, the occurrence of the respirable virulent form and the level of the infective concentration. Our study aimed to evaluate studies on legionellosis outbreaks attributed to cooling towers published within the last 11 years by means of a systematic review of the literature. 19 legionellosis outbreaks were identified affecting 12 countries. Recurring events were observed in Spain and Great Britain. In total, 1609 confirmed cases of legionellosis and a case-fatality rate of approximately 6% were reported. Duration of outbreaks was 65 days on average. For diagnosis the urinary antigen test was mainly used. Age, smoking, male sex and underlying diseases (diabetes, immunodeficiency) could be confirmed as risk factors. Smoking and underlying diseases were the most frequent risk factors associated with legionellosis in 11 and 10 of the 19 studies, respectively. The meteorological conditions varied strongly. Several studies reported a temporal association of outbreaks with inadequate maintenance of the cooling systems. A match of clinical and environmental isolates by serotyping and/or molecular subtyping could be confirmed in 84% of outbreaks. Legionella-contaminated cooling towers as environmental trigger, in particular in the neighbourhood of susceptible individuals, can cause severe health problems and even death. To prevent and control Legionella contamination of cooling towers, maintenance actions should focus on low-emission cleaning procedures of cooling towers combined with control measurements of water and air samples. Procedures allowing rapid detection and risk assessment in the case of outbreaks are essential for adequate public health measures. Systematic registration of cooling towers will facilitate the identification of the source of outbreaks and help to shorten their duration.


Assuntos
Ar Condicionado/métodos , Surtos de Doenças , Saúde Ambiental , Legionella , Legionelose/epidemiologia , Microbiologia da Água , Humanos , Legionella/isolamento & purificação , Legionelose/microbiologia , Espanha/epidemiologia , Reino Unido/epidemiologia
5.
Foodborne Pathog Dis ; 8(1): 39-44, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21034270

RESUMO

Yersinia enterocolitica is a major foodborne pathogen and the third most important bacteriological cause of diarrhea in Germany. However, studies investigating the occurrence of human pathogenic Y. enterocolitica in food at the retail level are very rare. Most of the studies published so far show qualitative but not quantitative data concerning the prevalence of this human pathogen. In this study the qualitative and quantitative assessment of human pathogenic Y. enterocolitica in different food matrices was investigated. For the qualitative analysis we used an enrichment method according to the International Organisation of Standardization (ISO) standard in combination with a real-time polymerase chain reaction (PCR) method detecting the ail gene of Y. enterocolitica. After detecting Y. enterocolitica in a sample, a quantitative investigation on Cefsulodin-Irgasan-Novobiocin (CIN) Agar was done to get information about the contamination level of the different samples. During the years 2008 and 2009, 446 samples of pork and pork products, 51 samples of game meat, and 61 raw milk samples were investigated for the presence of human pathogenic Y. enterocolitica. The samples were collected at the retail level in Bavaria. From the pork samples investigated, 81 samples (18%) were positive for the ail gene by real-time PCR, but human pathogenic Y. enterocolitica O:3 were found only in 46 (10%) pork samples by culture; the concentration in the samples ranged between 0.04 cfu/g and 2.30 × 10(5) cfu/g. Three game meat samples were positive by real-time PCR, but not by the cultural detection. All raw milk samples were negative by real-time PCR and culture.


Assuntos
Microbiologia de Alimentos , Yersinia enterocolitica/isolamento & purificação , Animais , Técnicas de Tipagem Bacteriana , Contagem de Colônia Microbiana , Análise de Alimentos , Alemanha , Humanos , Carne/análise , Carne/microbiologia , Leite/microbiologia , Reação em Cadeia da Polimerase , Suínos , Yersinia enterocolitica/classificação , Yersinia enterocolitica/genética
6.
Water Res ; 45(3): 1025-38, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21093010

RESUMO

Exposure to human pathogenic viruses in recreational waters has been shown to cause disease outbreaks. In the context of Article 14 of the revised European Bathing Waters Directive 2006/7/EC (rBWD, CEU, 2006) a Europe-wide surveillance study was carried out to determine the frequency of occurrence of two human enteric viruses in recreational waters. Adenoviruses were selected based on their near-universal shedding and environmental survival, and noroviruses (NoV) selected as being the most prevalent gastroenteritis agent worldwide. Concentration of marine and freshwater samples was done by adsorption/elution followed by molecular detection by (RT)-PCR. Out of 1410 samples, 553 (39.2%) were positive for one or more of the target viruses. Adenoviruses, detected in 36.4% of samples, were more prevalent than noroviruses (9.4%), with 3.5% GI and 6.2% GII, some samples being positive for both GI and GII. Of 513 human adenovirus-positive samples, 63 (12.3%) were also norovirus-positive, whereas 69 (7.7%) norovirus-positive samples were adenovirus-negative. More freshwater samples than marine water samples were virus-positive. Out of a small selection of samples tested for adenovirus infectivity, approximately one-quarter were positive. Sixty percent of 132 nested-PCR adenovirus-positive samples analysed by quantitative PCR gave a mean value of over 3000 genome copies per L of water. The simultaneous detection of infectious adenovirus and of adenovirus and NoV by (RT)PCR suggests that the presence of infectious viruses in recreational waters may constitute a public health risk upon exposure. These studies support the case for considering adenoviruses as an indicator of bathing water quality.


Assuntos
Adenoviridae/isolamento & purificação , Monitoramento Ambiental , Água Doce/virologia , Norovirus/isolamento & purificação , Recreação , Água do Mar/virologia , Microbiologia da Água , Adenoviridae/genética , Europa (Continente) , Norovirus/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA