Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 12(10)2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37240657

RESUMO

Near-infrared (NIR) imaging with indocyanine green (ICG) has proven to be useful in general, visceral, and transplant surgery. However, most studies have performed only qualitative assessments. Therefore, a systematic overview of all studies performing quantitative indocyanine green evaluation in general, visceral, and transplant surgeries should be conducted. Free term and medical subject heading (MeSH) term searches were performed in the Medline and Cochrane databases until October 2022. The main categories of ICG quantification were esophageal surgery (24.6%), reconstructive surgery (24.6%), and colorectal surgery (21.3%). Concordantly, anastomotic leak (41%) was the main endpoint, followed by the assessment of flap perfusion (23%) and the identification of structures and organs (14.8%). Most studies examined open surgery (67.6%) or laparoscopic surgery (23.1%). The analysis was mainly carried out using manufacturer software (44.3%) and open-source software (15.6%). The most frequently analyzed parameter was intensity over time for blood flow assessment, followed by intensity alone or intensity-to-background ratios for structure and organ identification. Intraoperative ICG quantification could become more important with the increasing impact of robotic surgery and machine learning algorithms for image and video analysis.

2.
Ann Surg ; 276(5): e386-e392, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33177354

RESUMO

OBJECTIVE: This international multicenter study by the Upper GI International Robotic Association aimed to gain insight in current techniques and outcomes of RAMIE worldwide. BACKGROUND: Current evidence for RAMIE originates from single-center studies, which may not be generalizable to the international multicenter experience. METHODS: Twenty centers from Europe, Asia, North-America, and South-America participated from 2016 to 2019. Main endpoints included the surgical techniques, clinical outcomes, and early oncological results of ramie. RESULTS: A total of 856 patients undergoing transthoracic RAMIE were included. Robotic surgery was applied for both the thoracic and abdominal phase (45%), only the thoracic phase (49%), or only the abdominal phase (6%). In most cases, the mediastinal lymphadenectomy included the low paraesophageal nodes (n=815, 95%), subcarinal nodes (n = 774, 90%), and paratracheal nodes (n = 537, 63%). When paratracheal lymphadenectomy was performed during an Ivor Lewis or a McKeown RAMIE procedure, recurrent laryngeal nerve injury occurred in 3% and 11% of patients, respectively. Circular stapled (52%), hand-sewn (30%), and linear stapled (18%) anastomotic techniques were used. In Ivor Lewis RAMIE, robot-assisted hand-sewing showed the highest anastomotic leakage rate (33%), while lower rates were observed with circular stapling (17%) and linear stapling (15%). In McKeown RAMIE, a hand-sewn anastomotic technique showed the highest leakage rate (27%), followed by linear stapling (18%) and circular stapling (6%). CONCLUSION: This study is the first to provide an overview of the current techniques and outcomes of transthoracic RAMIE worldwide. Although these results indicate high quality of the procedure, the optimal approach should be further defined.


Assuntos
Boehmeria , Neoplasias Esofágicas , Procedimentos Cirúrgicos Robóticos , Robótica , Neoplasias Esofágicas/cirurgia , Esofagectomia/métodos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Sistema de Registros , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento
3.
Z Gastroenterol ; 59(1): 56-62, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33429451

RESUMO

BACKGROUND: Robotic liver surgery is emerging as the future of minimal invasive surgery. The robotic surgical system offers a stable camera platform, elimination of physiologic tremor, augmented surgical dexterity as well as improved ergonomics because of a seated operating position. Due to the theoretical advantages of the robotic assisted system, complex liver surgery might be an especially interesting indication for a robotic approach since it demands delicate tissue dissection, precise intracorporeal suturing as well as difficult parenchymal transection with subsequent need for meticulous hemostasis and biliostasis. MATERIAL AND METHODS: An analysis of English and German literature on open, laparoscopic and robotic liver surgery was performed and this review provides a general overview of the existing literature along with current standards and aims to specifically point out future directions of robotic liver surgery. RESULTS: Robotic liver surgery is safe and feasible compared to open and laparoscopic surgery, with improved short-term postoperative outcomes and at least non-inferior oncological outcomes. CONCLUSION: In complex cases including major hepatectomies, extended hepatectomies with biliary reconstruction and difficult segmentectomies of the posterior-superior segments, robotic surgery appears to emerge as a reasonable alternative to open surgery rather than being an alternative to laparoscopic procedures.


Assuntos
Hepatectomia/tendências , Laparoscopia , Fígado/cirurgia , Procedimentos Cirúrgicos Robóticos/normas , Humanos , Padrões de Referência , Procedimentos Cirúrgicos Robóticos/métodos , Robótica
4.
J Surg Res ; 148(2): 126-35, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18456280

RESUMO

BACKGROUND: Cytoprotective proteins, such as heme oxygenase-1 (HO-1), play a decisive role in ischemia-reperfusion injury during kidney transplantation. The aim of this study was to investigate the impact of heme oxygenase-1 on microcirculation and on ischemia-reperfusion injury in an isogenic kidney transplantation rat model. MATERIALS AND METHODS: Seventy male Lewis rats were distributed into three groups. In Group 1(control), the kidneys were only mobilized. In Groups 2 and 3, bilateral nephrectomy was performed, and a kidney from another Lewis rat was orthotopically transplanted on the left side. The donor animals in Group 3 received preconditioning with the HO-1 inductor hemin. 24 h after reperfusion graft function and morphology were examined. Microcirculation was investigated by in vivo microscopy of the renal surface 1 h after reperfusion. RESULTS: HO-1 preconditioning led to significantly lower serum creatinine and serum urea, as well as less histological damage and inducible nitric oxide synthase expression. Microcirculation was improved by a significant enlargement of the vascular diameter and an increase of the capillary flow. CONCLUSIONS: Treatment with hemin improves microcirculation by induction of HO-1 and reduces ischemia-reperfusion injury after kidney transplantation. HO-1 induction was shown to be a promising approach in the preconditioning of donor kidneys.


Assuntos
Heme Oxigenase-1/metabolismo , Transplante de Rim/fisiologia , Rim/irrigação sanguínea , Traumatismo por Reperfusão/prevenção & controle , Animais , Creatinina/sangue , Modelos Animais de Doenças , Heme Oxigenase-1/genética , Hemina/farmacologia , Precondicionamento Isquêmico/métodos , Rim/patologia , Transplante de Rim/patologia , Masculino , Microcirculação/fisiologia , Óxido Nítrico Sintase/metabolismo , Ratos , Ratos Endogâmicos Lew , Traumatismo por Reperfusão/fisiopatologia , Ureia/sangue
5.
Microsurgery ; 25(8): 614-23, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16281279

RESUMO

During the education of the next generation of scientists in experimental research, careful instruction in surgical techniques is of major importance. This applies in particular to complicated microsurgical models, which require a structured teaching concept with clearly laid-down working steps and adequate didactic resources. Transplantations in rats are undoubtedly among the most difficult models in experimental surgery. Because completely sutured orthotopic liver transplantation and kidney transplantation have been practiced for many years in our Surgical Research Unit, techniques must be transmitted to future generations. A microsurgical training program has been set up with the aim of being efficient, transparent, and motivating. Simply learning-by-doing in the sense of "laissez-faire" is ineffective and costly. Our training program is based on "three-phase didactics," in which the learning targets are presented in sequence and are clearly defined. This report is intended to give a brief overview of the principal transplantation models and to serve as a guide for teaching these models.


Assuntos
Currículo , Transplante de Rim/educação , Transplante de Fígado/educação , Microcirurgia/educação , Animais , Competência Clínica , Humanos , Modelos Animais , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA