Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(5): e14299, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520072

RESUMO

A new generation cone-beam computed tomography (CBCT) system with new hardware design and advanced image reconstruction algorithms is available for radiation treatment simulation or adaptive radiotherapy (HyperSight CBCT imaging solution, Varian Medical Systems-a Siemens Healthineers company). This study assesses the CBCT image quality metrics using the criteria routinely used for diagnostic CT scanner accreditation as a first step towards the future use of HyperSight CBCT images for treatment planning and target/organ delineations. Image performance was evaluated using American College of Radiology (ACR) Program accreditation phantom tests for diagnostic computed tomography systems (CTs) and compared HyperSight images with a standard treatment planning diagnostic CT scanner (Siemens SOMATOM Edge) and with existing CBCT systems (Varian TrueBeam version 2.7 and Varian Halcyon version 2.0).  Image quality performance for all Varian HyperSight CBCT vendor-provided imaging protocols were assessed using ACR head and body ring CT phantoms, then compared to existing imaging modalities. Image quality analysis metrics included contrast-to-noise (CNR), spatial resolution, Hounsfield number (HU) accuracy, image scaling, and uniformity. All image quality assessments were made following the recommendations and passing criteria provided by the ACR. The Varian HyperSight CBCT imaging system demonstrated excellent image quality, with the majority of vendor-provided imaging protocols capable of passing all ACR CT accreditation standards. Nearly all (8/11) vendor-provided protocols passed ACR criteria using the ACR head phantom, with the Abdomen Large, Pelvis Large, and H&N vendor-provided protocols produced HU uniformity values slightly exceeding passing criteria but remained within the allowable minor deviation levels (5-7 HU maximum differences). Compared to other existing CT and CBCT imaging modalities, both HyperSight Head and Pelvis imaging protocols matched the performance of the SOMATOM CT scanner, and both the HyperSight and SOMATOM CT substantially surpassed the performance of the Halcyon 2.0 and TrueBeam version 2.7 systems. Varian HyperSight CBCT imaging system could pass almost all tests for all vendor-provided protocols using ACR accreditation criteria, with image quality similar to those produced by diagnostic CT scanners and significantly better than existing linac-based CBCT imaging systems.


Assuntos
Benchmarking , Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Aceleradores de Partículas , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada de Feixe Cônico/instrumentação , Aceleradores de Partículas/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Acreditação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
Adv Radiat Oncol ; 9(3): 101385, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38495035

RESUMO

Purpose: Our purpose was to report complications requiring surgical intervention among patients treated with postmastectomy proton radiation therapy (PMPRT) for breast cancer in the setting of breast reconstruction (BR). Methods and Materials: Patients enrolled on a prospective proton registry who underwent BR with immediate autologous flap, tissue expander (TE), or implant in place during PMPRT (50/50.4 Gy +/- chest wall boost) were eligible. Major reconstruction complication (MRC) was defined as a complication requiring surgical intervention. Absolute reconstruction failure was an MRC requiring surgical removal of BR. A routine revision (RR) was a plastic surgery refining cosmesis of the BR. Kaplan-Meier method was used to assess disease outcomes and MRC. Cox regression was used to assess predictors of MRC. Results: Seventy-three courses of PMPRT were delivered to 68 women with BR between 2013 and 2021. Median follow-up was 42.1 months. Median age was 47 years. Fifty-six (76.7%) courses used pencil beam scanning PMPRT. Of 73 BR, 29 were flaps (39.7%), 30 implants (41.1%), and 14 TE (19.2%) at time of irradiation. There were 20 (27.4%) RR. There were 9 (12.3%) MRC among 5 implants, 2 flaps, and 2 TE, occurring a median of 29 months from PMPRT start. Three-year freedom from MRC was 86.9%. Three (4.1%) of the MRC were absolute reconstruction failure. Complications leading to MRC included capsular contracture in 5, fat necrosis in 2, and infection in 2. On univariable analysis, BR type, boost, proton technique, age, and smoking status were not associated with MRC, whereas higher body mass index trended toward significance (hazard ratio, 1.07; 95% CI, 0.99-1.16; P = .10). Conclusions: Patients undergoing PMPRT to BR had a 12.3% incidence of major complications leading to surgical intervention, and total loss of BR was rare. MRC rates were similar among reconstruction types. Minor surgery for RR is common in our practice.

3.
Artigo em Inglês | MEDLINE | ID: mdl-37101538

RESUMO

The emergence of the Halcyon linear accelerator has allowed for increased patient throughput and improved treatment times for common treatment sites in radiation oncology. However, it has been shown that this can lead to increased surface dose in sites like breast cancer compared with treatments on conventional machines with flattened radiation beams. Cherenkov imaging can be used to estimate surface dose by detection of Cherenkov photons emitted in proportion to energy deposition from high energy electrons in tissue. Phantom studies were performed with both square beams in reference conditions and with clinical treatments, and dosimeter readings and Cherenkov images report higher surface dose (25% for flat phantom entrance dose, 5.9% for breast phantom treatment) from Halcyon beam deliveries than for equivalent deliveries from a TrueBeam linac. Additionally, the first Cherenkov images of a patient treated with Halcyon were acquired, and superficial dose was estimated.

4.
Cancers (Basel) ; 13(16)2021 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-34439398

RESUMO

Ultra-high dose rate FLASH proton radiotherapy (F-PRT) has been shown to reduce normal tissue toxicity compared to standard dose rate proton radiotherapy (S-PRT) in experiments using the entrance portion of the proton depth dose profile, while proton therapy uses a spread-out Bragg peak (SOBP) with unknown effects on FLASH toxicity sparing. To investigate, the biological effects of F-PRT using an SOBP and the entrance region were compared to S-PRT in mouse intestine. In this study, 8-10-week-old C57BL/6J mice underwent 15 Gy (absorbed dose) whole abdomen irradiation in four groups: (1) SOBP F-PRT, (2) SOBP S-PRT, (3) entrance F-PRT, and (4) entrance S-PRT. Mice were injected with EdU 3.5 days after irradiation, and jejunum segments were harvested and preserved. EdU-positive proliferating cells and regenerated intestinal crypts were quantified. The SOBP had a modulation (width) of 2.5 cm from the proximal to distal 90%. Dose rates with a SOBP for F-PRT or S-PRT were 108.2 ± 8.3 Gy/s or 0.82 ± 0.14 Gy/s, respectively. In the entrance region, dose rates were 107.1 ± 15.2 Gy/s and 0.83 ± 0.19 Gy/s, respectively. Both entrance and SOBP F-PRT preserved a significantly higher number of EdU + /crypt cells and percentage of regenerated crypts compared to S-PRT. Moreover, tumor growth studies showed no difference between SOBP and entrance for either of the treatment modalities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA