Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
medRxiv ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38765972

RESUMO

Objective: This study aims to provide data on the effects of glucagon-like peptide 1 receptor (GLP-1R) agonists on intraocular pressure (IOP). Design: Retrospective cohort study. Subjects Participants and/or Controls: 1247 glaucoma surgery and treatment naïve eyes of 626 patients who were initiated on GLP-1R agonists compared to 1083 glaucoma surgery and treatment naïve eyes of 547 patients who were initiated on other oral antidiabetics. Methods Intervention or Testing: The University of California Health Data Warehouse was queried for patients exposed to GLP-1R agonists or other oral antidiabetics. Index date was defined as the date of first exposure to the medication. Eyes with at least one pre-exposure and one post-exposure tonometry record within 365 days of the index date were included in the analysis. Clinical and laboratory data elements were extracted from the database. Eyes were censored from the analysis upon exposure to glaucoma hypotensive medication or glaucoma surgery. ΔIOP was analyzed using a paired t-test. Regression analysis was conducted using generalized estimating equations (GEE) accounting for inter-eye correlation. Sensitivity analyses were performed to assess the robustness of the findings. Main Outcome Measures: Primary outcome measure was ΔIOP after exposure to the medication. Results: The median age of all included subjects was 66.2 years [IQR=18.3]; 607 (51.7%) were female, and 667 (56.9%) were Caucasian. Median pre-exposure IOP, HbA1c, and BMI were 15.2 mmHg [IQR=3.8], 7.5 [IQR=2.4], and 29.8 [IQR=9.4], respectively. 776 individuals (66.1%) had diabetes, with the median number of active oral antidiabetics being 1.0 [IQR=1.0], and 441 (37.5%) being insulin users. Several pre-exposure characteristics significantly differed between the GLP-1R agonist and the control group. The mean ΔIOP was -0.4±2.8 mmHg (paired t-test p<0.001) and -0.2±3.3 mmHg (paired t-test p = 0.297) in the GLP-1R agonist and other antidiabetics groups, respectively. Pre-exposure IOP was the only independent predictor of ΔIOP in multivariable GEE. Sensitivity analyses yielded similar results. Conclusions: Although GLP-1R agonists were significantly associated with a decrease in IOP in the paired analysis, they were not associated with ΔIOP in multivariable GEE. Moreover, the difference between the ΔIOP in the two groups was small. Future prospective studies following a standardized dose and delivery method may provide further insights.

2.
Curr Opin Ophthalmol ; 33(5): 418-424, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35819893

RESUMO

PURPOSE OF REVIEW: The purpose of this review is to provide an overview of updates in data standardization and data privacy in ophthalmology. These topics represent two key aspects of medical information sharing and are important knowledge areas given trends in data-driven healthcare. RECENT FINDINGS: Standardization and privacy can be seen as complementary aspects that pertain to data sharing. Standardization promotes the ease and efficacy through which data is shared. Privacy considerations ensure that data sharing is appropriate and sufficiently controlled. There is active development in both areas, including government regulations and common data models to advance standardization, and application of technologies such as blockchain and synthetic data to help tackle privacy issues. These advancements have seen use in ophthalmology, but there are areas where further work is required. SUMMARY: Information sharing is fundamental to both research and care delivery, and standardization/privacy are key constituent considerations. Therefore, widespread engagement with, and development of, data standardization and privacy ecosystems stand to offer great benefit to ophthalmology.


Assuntos
Oftalmologia , Privacidade , Ecossistema , Humanos , Disseminação de Informação , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA