Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
PLoS Biol ; 22(9): e3002774, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39241107

RESUMO

Modular organization at approximately 1 mm scale could be fundamental to cortical processing, but its presence in human association cortex is unknown. Using custom-built, high-density electrode arrays placed on the cortical surface of 7 patients undergoing awake craniotomy for tumor excision, we investigated receptive speech processing in the left (dominant) human posterior superior temporal gyrus. Responses to consonant-vowel syllables and noise-vocoded controls recorded with 1,024 channel micro-grids at 200 µm pitch demonstrated roughly circular domains approximately 1.7 mm in diameter, with sharp boundaries observed in 128 channel linear arrays at 50 µm pitch, possibly consistent with a columnar organization. Peak latencies to syllables in different modules were bimodally distributed centered at 252 and 386 ms. Adjacent modules were sharply delineated from each other by their distinct time courses and stimulus selectivity. We suggest that receptive language cortex may be organized in discrete processing modules.


Assuntos
Percepção da Fala , Lobo Temporal , Humanos , Lobo Temporal/fisiologia , Percepção da Fala/fisiologia , Adulto , Masculino , Feminino , Pessoa de Meia-Idade , Mapeamento Encefálico/métodos , Idioma , Estimulação Acústica
2.
Sci Transl Med ; 16(744): eadj7257, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38657026

RESUMO

Functional mapping during brain surgery is applied to define brain areas that control critical functions and cannot be removed. Currently, these procedures rely on verbal interactions between the neurosurgeon and electrophysiologist, which can be time-consuming. In addition, the electrode grids that are used to measure brain activity and to identify the boundaries of pathological versus functional brain regions have low resolution and limited conformity to the brain surface. Here, we present the development of an intracranial electroencephalogram (iEEG)-microdisplay that consists of freestanding arrays of 2048 GaN light-emitting diodes laminated on the back of micro-electrocorticography electrode grids. With a series of proof-of-concept experiments in rats and pigs, we demonstrate that these iEEG-microdisplays allowed us to perform real-time iEEG recordings and display cortical activities by spatially corresponding light patterns on the surface of the brain in the surgical field. Furthermore, iEEG-microdisplays allowed us to identify and display cortical landmarks and pathological activities from rat and pig models. Using a dual-color iEEG-microdisplay, we demonstrated coregistration of the functional cortical boundaries with one color and displayed the evolution of electrical potentials associated with epileptiform activity with another color. The iEEG-microdisplay holds promise to facilitate monitoring of pathological brain activity in clinical settings.


Assuntos
Encéfalo , Eletroencefalografia , Animais , Encéfalo/fisiologia , Eletroencefalografia/métodos , Suínos , Ratos , Neurônios/fisiologia , Mapeamento Encefálico/métodos , Ratos Sprague-Dawley , Eletrocorticografia/métodos , Masculino
3.
J Neurosurg ; 140(3): 665-676, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37874692

RESUMO

OBJECTIVE: The study objective was to evaluate intraoperative experience with newly developed high-spatial-resolution microelectrode grids composed of poly(3,4-ethylenedioxythiophene) with polystyrene sulfonate (PEDOT:PSS), and those composed of platinum nanorods (PtNRs). METHODS: A cohort of patients who underwent craniotomy for pathological tissue resection and who had high-spatial-resolution microelectrode grids placed intraoperatively were evaluated. Patient demographic and baseline clinical variables as well as relevant microelectrode grid characteristic data were collected. The primary and secondary outcome measures of interest were successful microelectrode grid utilization with usable resting-state or task-related data, and grid-related adverse intraoperative events and/or grid dysfunction. RESULTS: Included in the analysis were 89 cases of patients who underwent a craniotomy for resection of neoplasms (n = 58) or epileptogenic tissue (n = 31). These cases accounted for 94 grids: 58 PEDOT:PSS and 36 PtNR grids. Of these 94 grids, 86 were functional and used successfully to obtain cortical recordings from 82 patients. The mean cortical grid recording duration was 15.3 ± 1.15 minutes. Most recordings in patients were obtained during experimental tasks (n = 52, 58.4%), involving language and sensorimotor testing paradigms, or were obtained passively during resting state (n = 32, 36.0%). There were no intraoperative adverse events related to grid placement. However, there were instances of PtNR grid dysfunction (n = 8) related to damage incurred by suboptimal preoperative sterilization (n = 7) and improper handling (n = 1); intraoperative recordings were not performed. Vaporized peroxide sterilization was the most optimal sterilization method for PtNR grids, providing a significantly greater number of usable channels poststerilization than did steam-based sterilization techniques (median 905.0 [IQR 650.8-935.5] vs 356.0 [IQR 18.0-597.8], p = 0.0031). CONCLUSIONS: High-spatial-resolution microelectrode grids can be readily incorporated into appropriately selected craniotomy cases for clinical and research purposes. Grids are reliable when preoperative handling and sterilization considerations are accounted for. Future investigations should compare the diagnostic utility of these high-resolution grids to commercially available counterparts and assess whether diagnostic discrepancies relate to clinical outcomes.


Assuntos
Sistemas Computacionais , Craniotomia , Humanos , Microeletrodos , Idioma , Peróxidos
4.
bioRxiv ; 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37503216

RESUMO

Brain surgeries are among the most delicate clinical procedures and must be performed with the most technologically robust and advanced tools. When such surgical procedures are performed in functionally critical regions of the brain, functional mapping is applied as a standard practice that involves direct coordinated interactions between the neurosurgeon and the clinical neurology electrophysiology team. However, information flow during these interactions is commonly verbal as well as time consuming which in turn increases the duration and cost of the surgery, possibly compromising the patient outcomes. Additionally, the grids that measure brain activity and identify the boundaries of pathological versus functional brain regions suffer from low resolution (3-10 mm contact to contact spacing) with limited conformity to the brain surface. Here, we introduce a brain intracranial electroencephalogram microdisplay (Brain-iEEG-microdisplay) which conforms to the brain to measure the brain activity and display changes in near real-time (40 Hz refresh rate) on the surface of the brain in the surgical field. We used scalable engineered gallium nitride (GaN) substrates with 6" diameter to fabricate, encapsulate, and release free-standing arrays of up to 2048 GaN light emitting diodes (µLEDs) in polyimide substrates. We then laminated the µLED arrays on the back of micro-electrocorticography (µECoG) platinum nanorod grids (PtNRGrids) and developed hardware and software to perform near real-time intracranial EEG analysis and activation of light patterns that correspond to specific cortical activities. Using the Brain-iEEG-microdisplay, we precisely ideFSntified and displayed important cortical landmarks and pharmacologically induced pathological activities. In the rat model, we identified and displayed individual cortical columns corresponding to individual whiskers and the near real-time evolution of epileptic discharges. In the pig animal model, we demonstrated near real-time mapping and display of cortical functional boundaries using somatosensory evoked potentials (SSEP) and display of responses to direct electrical stimulation (DES) from the surface or within the brain tissue. Using a dual-color Brain-iEEG-microdisplay, we demonstrated co-registration of the functional cortical boundaries with one color and displayed the evolution of electrical potentials associated with epileptiform activity with another color. The Brain-iEEG-microdisplay holds the promise of increasing the efficiency of diagnosis and possibly surgical treatment, thereby reducing the cost and improving patient outcomes which would mark a major advancement in neurosurgery. These advances can also be translated to broader applications in neuro-oncology and neurophysiology.

5.
Adv Healthc Mater ; 7(22): e1800923, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30369088

RESUMO

Poly(3,4-ethylenenedioxythiophene) or PEDOT is a promising candidate for next-generation neuronal electrode materials but its weak adhesion to underlying metallic conductors impedes its potential. An effective method of mechanically anchoring the PEDOT within an Au nanorod (Au-nr) structure is reported and it is demonstrated that it provides enhanced adhesion and overall PEDOT layer stability. Cyclic voltammetry (CV) stress is used to investigate adhesion and stability of spin-cast and electrodeposited PEDOT. The Au-nr adhesion layer permits 10 000 CV cycles of coated PEDOT film in phosphate buffered saline solution without delamination nor significant change of the electrochemical impedance, whereas PEDOT coating film on planar Au electrodes delaminates at or below 1000 cycles. Under CV stress, spin-cast PEDOT on planar Au delaminates, whereas electroplated PEDOT on planar Au encounters surface leaching/decomposition. After 5 weeks of accelerated aging tests at 60 °C, the electrodeposited PEDOT/Au-nr microelectrodes demonstrate a 92% channel survival compared to only 25% survival for spin-cast PEDOT on planar films. Furthermore, after a 10 week chronic implantation onto mouse barrel cortex, PEDOT/Au-nr microelectrodes do not exhibit delamination nor morphological changes, whereas the conventional PEDOT microelectrodes either partially or fully delaminate. Immunohistochemical evaluation demonstrates no or minimal response to the PEDOT implant.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/química , Ouro/química , Nanotubos/química , Neurônios/fisiologia , Polímeros/química , Animais , Encéfalo/patologia , Eletrodos Implantados , Camundongos , Camundongos Endogâmicos C57BL , Microeletrodos , Aderências Teciduais
6.
Neuroimage ; 63(1): 157-165, 2012 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-22759995

RESUMO

Intracranial electrode arrays are routinely used in the pre-surgical evaluation of patients with medically refractory epilepsy, and recordings from these electrodes have been increasingly employed in human cognitive neurophysiology due to their high spatial and temporal resolution. For both researchers and clinicians, it is critical to localize electrode positions relative to the subject-specific neuroanatomy. In many centers, a post-implantation MRI is utilized for electrode detection because of its higher sensitivity for surgical complications and the absence of radiation. However, magnetic susceptibility artifacts surrounding each electrode prohibit unambiguous detection of individual electrodes, especially those that are embedded within dense grid arrays. Here, we present an efficient method to accurately localize intracranial electrode arrays based on pre- and post-implantation MR images that incorporates array geometry and the individual's cortical surface. Electrodes are directly visualized relative to the underlying gyral anatomy of the reconstructed cortical surface of individual patients. Validation of this approach shows high spatial accuracy of the localized electrode positions (mean of 0.96 mm ± 0.81 mm for 271 electrodes across 8 patients). Minimal user input, short processing time, and utilization of radiation-free imaging are strong incentives to incorporate quantitatively accurate localization of intracranial electrode arrays with MRI for research and clinical purposes. Co-registration to a standard brain atlas further allows inter-subject comparisons and relation of intracranial EEG findings to the larger body of neuroimaging literature.


Assuntos
Artefatos , Encéfalo/anatomia & histologia , Eletrodos Implantados , Eletroencefalografia/instrumentação , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Encéfalo/cirurgia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Hum Brain Mapp ; 33(3): 715-26, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21500313

RESUMO

The effects of neural activity on cerebral hemodynamics underlie human brain imaging with functional magnetic resonance imaging and positron emission tomography. However, the threshold and characteristics of the converse effects, wherein the cerebral hemodynamic and metabolic milieu influence neural activity, remain unclear. We tested whether mild hypercapnia (5% CO2 ) decreases the magnetoencephalogram response to auditory pattern recognition and visual semantic tasks. Hypercapnia induced statistically significant decreases in event-related fields without affecting behavioral performance. Decreases were observed in early sensory components in both auditory and visual modalities as well as later cognitive components related to memory and language. Effects were distributed across cortical regions. Decreases were comparable in evoked versus spontaneous spectral power. Hypercapnia is commonly used with hemodynamic models to calibrate the blood oxygenation level-dependent response. Modifying model assumptions to incorporate the current findings produce a modest but measurable decrease in the estimated cerebral metabolic rate for oxygen change with activation. Because under normal conditions, low cerebral pH would arise when bloodflow is unable to keep pace with neuronal activity, the cortical depression observed here may reflect a homeostatic mechanism by which neuronal activity is adjusted to a level that can be sustained by available bloodflow. Animal studies suggest that these effects may be mediated by pH-modulating presynaptic adenosine receptors. Although the data is not clear, comparable changes in cortical pH to those induced here may occur during sleep apnea, sleep, and exercise. If so, these results suggest that such activities may in turn have generalized depressive effects on cortical activity.


Assuntos
Córtex Cerebral/irrigação sanguínea , Córtex Cerebral/fisiopatologia , Hemodinâmica/fisiologia , Hipercapnia/fisiopatologia , Adulto , Percepção Auditiva/fisiologia , Circulação Cerebrovascular/fisiologia , Potenciais Evocados Auditivos/fisiologia , Potenciais Evocados Visuais/fisiologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Magnetocardiografia , Masculino , Percepção Visual/fisiologia , Adulto Jovem
8.
J Neurosci ; 31(43): 15257-63, 2011 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-22031871

RESUMO

Blurring of the cortical gray and white matter border on MRI is associated with normal aging, pathological aging, and the presence of focal cortical dysplasia. However, it remains unclear whether normal variations in signal intensity contrast at the gray and white matter junction reflect the functional integrity of subjacent tissue. This study explores the relationship between verbal abilities and gray and white matter contrast (GWC) in healthy human adults. Participants were scanned at 3 T MRI and administered standardized measures of verbal expression and verbal working memory. GWC was estimated by calculating the non-normalized T1 image intensity contrast above and below the cortical gray/white matter interface. Spherical averaging and whole-brain correlational analyses were performed. Sulcal regions exhibited higher contrast compared to gyral regions. We found a strongly lateralized and regionally specific profile with reduced verbal expression abilities associated with blurring in left hemisphere inferior frontal cortex and temporal pole. Reduced verbal working memory was associated with blurring in widespread left frontal and temporal cortices. Such lateralized and focal results provide support for GWC as a measure of regional functional integrity and highlight its potential role in probing the neuroanatomical substrates of cognition in healthy and diseased populations.


Assuntos
Mapeamento Encefálico , Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Individualidade , Fibras Nervosas Mielinizadas/fisiologia , Comportamento Verbal/fisiologia , Adulto , Idoso , Cognição , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Adulto Jovem
9.
PLoS One ; 6(2): e16430, 2011 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-21326599

RESUMO

Magnetic resonance imaging has revolutionized the detection of structural abnormalities in patients with epilepsy. However, many focal abnormalities remain undetected in routine visual inspection. Here we use an automated, surface-based method for quantifying morphometric features related to epileptogenic cortical malformations to detect abnormal cortical thickness and blurred gray-white matter boundaries. Using MRI morphometry at 3T with surface-based spherical averaging techniques that precisely align anatomical structures between individual brains, we compared single patients with known lesions to a large normal control group to detect clusters of abnormal cortical thickness, gray-white matter contrast, local gyrification, sulcal depth, jacobian distance and curvature. To assess the effects of threshold and smoothing on detection sensitivity and specificity, we systematically varied these parameters with different thresholds and smoothing levels. To test the effectiveness of the technique to detect lesions of epileptogenic character, we compared the detected structural abnormalities to expert-tracings, intracranial EEG, pathology and surgical outcome in a homogeneous patient sample. With optimal parameters and by combining thickness and GWC, the surface-based detection method identified 92% of cortical lesions (sensitivity) with few false positives (96% specificity), successfully discriminating patients from controls 94% of the time. The detected structural abnormalities were related to the seizure onset zones, abnormal histology and positive outcome in all surgical patients. However, the method failed to adequately describe lesion extent in most cases. Automated surface-based MRI morphometry, if used with optimized parameters, may be a valuable additional clinical tool to improve the detection of subtle or previously occult malformations and therefore could improve identification of patients with intractable focal epilepsy who may benefit from surgery.


Assuntos
Córtex Cerebral/anormalidades , Córtex Cerebral/diagnóstico por imagem , Epilepsia/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Malformações do Sistema Nervoso/diagnóstico por imagem , Adulto , Mapeamento Encefálico/métodos , Córtex Cerebral/patologia , Criança , Eletroencefalografia , Epilepsia/congênito , Epilepsia/etiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Malformações do Sistema Nervoso/complicações , Malformações do Sistema Nervoso/patologia , Radiografia , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
10.
J Cogn Neurosci ; 19(9): 1476-87, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17714009

RESUMO

Voice onset time (VOT) provides an important auditory cue for recognizing spoken consonant-vowel syllables. Although changes in the neuromagnetic response to consonant-vowel syllables with different VOT have been examined, such experiments have only manipulated VOT with respect to voicing. We utilized the characteristics of a previously developed asymmetric VOT continuum [Liederman, J., Frye, R. E., McGraw Fisher, J., Greenwood, K., & Alexander, R. A temporally dynamic contextual effect that disrupts voice onset time discrimination of rapidly successive stimuli. Psychonomic Bulletin and Review, 12, 380-386, 2005] to determine if changes in the prominent M100 neuromagnetic response were linearly modulated by VOT. Eight right-handed, English-speaking, normally developing participants performed a VOT discrimination task during a whole-head neuromagnetic recording. The M100 was identified in the gradiometers overlying the right and left temporal cortices and single dipoles were fit to each M100 waveform. A repeated measures analysis of variance with post hoc contrast test for linear trend was used to determine whether characteristics of the M100 were linearly modulated by VOT. The morphology of the M100 gradiometer waveform and the peak latency of the dipole waveform were linearly modulated by VOT. This modulation was much greater in the left, as compared to the right, hemisphere. The M100 dipole moved in a linear fashion as VOT increased in both hemispheres, but along different axes in each hemisphere. This study suggests that VOT may linearly modulate characteristics of the M100, predominately in the left hemisphere, and suggests that the VOT of consonant-vowel syllables, instead of, or in addition to, voicing, should be examined in future experiments.


Assuntos
Potenciais Evocados Auditivos/fisiologia , Modelos Lineares , Fonética , Tempo de Reação/fisiologia , Percepção da Fala/fisiologia , Estimulação Acústica , Adulto , Análise de Variância , Estimulação Elétrica/métodos , Feminino , Lateralidade Funcional , Humanos , Imageamento por Ressonância Magnética , Magnetoencefalografia/métodos , Masculino , Discriminação da Altura Tonal/fisiologia , Psicofísica , Tempo de Reação/efeitos da radiação , Testes de Discriminação da Fala
11.
Epilepsia ; 46(8): 1264-72, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16060938

RESUMO

PURPOSE: To examine whether magnetoencephalography (MEG) can be used to determine patterns of brain activity underlying widespread paroxysms of epilepsy patients, thereby extending the applicability of MEG to a larger population of epilepsy patients. METHODS: We studied two children with symptomatic localization-related epilepsy. Case 1 had widespread spikes in EEG with an operation scar from a resection of a brain tumor; Case 2 had hemispheric slow-wave activity in EEG with sensory auras. MEG was collected with a 204-channel helmet-shaped sensor array. Dynamic statistical parametric maps (dSPMs) were constructed to estimate the cortical distribution of interictal discharges for these patients. Equivalent current dipoles (ECDs) also were calculated for comparison with the results of dSPM. RESULTS: In case 1 with widespread spikes, dSPM presented the major activity at the vicinity of the operation scar in the left frontal lobe at the peak of the spikes, and some activities were detected in the left temporal lobe just before the peak in some spikes. In case 2 with hemispheric slow waves, the most active area was located in the left parietal lobe, and additional activity was seen at the ipsilateral temporal and frontal lobes in dSPM. The source estimates correlated well with the ictal manifestation and interictal single-photon emission computed tomography (SPECT) findings for this patient. In comparison with the results of ECDs, ECDs could not express a prior activity at the left temporal lobe in case 1 and did not model well the MEG data in case 2. CONCLUSIONS: We suggest that by means of dSPM, MEG is useful for presurgical evaluation of patients, not only with localized epileptiform activity, but also with widespread spikes or slow waves, because it requires no selections of channels and no time-point selection.


Assuntos
Mapeamento Encefálico/métodos , Córtex Cerebral/fisiopatologia , Eletroencefalografia/estatística & dados numéricos , Epilepsia/diagnóstico , Magnetoencefalografia/métodos , Adolescente , Córtex Cerebral/irrigação sanguínea , Córtex Cerebral/diagnóstico por imagem , Pré-Escolar , Epilepsia/fisiopatologia , Feminino , Humanos , Magnetoencefalografia/estatística & dados numéricos , Masculino , Cuidados Pré-Operatórios , Tomografia Computadorizada de Emissão de Fóton Único
12.
J Child Neurol ; 20(4): 363-9, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15921240

RESUMO

Our current purpose is to evaluate the applicability of dynamic statistical parametric mapping, a novel method for localizing epileptiform activity recorded with magnetoencephalography in patients with epilepsy. We report four pediatric patients with focal epilepsies. Magnetoencephalographic data were collected with a 306-channel whole-head helmet-shaped sensor array. We calculated equivalent current dipoles and dynamic statistical parametric mapping movies of the interictal epileptiform discharges that were based in the minimum-L2 norm estimate, minimizing the square sum of the dipole element amplitudes. The dynamic statistical parametric mapping analysis of interictal epileptiform discharges can demonstrate the rapid change and propagation of interical epileptiform discharges. According to these findings, specific epileptogenic lesion-focal cortical dysplasia could be found and patients could be operated on successfully. The presurgical analysis of interictal epileptiform discharges using dynamic statistical parametric mapping seems to be promising in patients with a possible underlying focal cortical dysplasia and might help to guide the placement of invasive electrodes.


Assuntos
Mapeamento Encefálico/métodos , Córtex Cerebral/fisiopatologia , Epilepsias Parciais/fisiopatologia , Magnetoencefalografia , Adolescente , Adulto , Criança , Pré-Escolar , Eletroencefalografia , Feminino , Humanos , Masculino , Distribuições Estatísticas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA