Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Microbes Infect ; 19(4-5): 277-287, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28025070

RESUMO

Anti-retroviral therapy is useful to treat human immunodeficiency virus type 1 (HIV-1)-infected individuals, but has some major problems, such as the generation of multidrug-resistant viruses. To develop a novel supplemental or alternative therapeutic for CCR5-tropic (R5) HIV-1 infection, we generated a recombinant vesicular stomatitis virus (rVSV) in which the gene encoding its envelope glycoprotein (G) was replaced with the genes encoding R5 HIV-1 receptors (human CD4 and CCR5), designated VSVΔG-CC5. Our present data demonstrate that this rVSV specifically infects cells that are transiently expressing R5 HIV-1 envelope glycoproteins, but does not infect those expressing CXCR4-tropic HIV-1 envelope glycoproteins. Notably, after a CD4+CCR5+ T cell line or primary cells initially infected with R5 HIV-1 were inoculated with G-complemented VSVΔG-CC5, the rVSV significantly reduced the number of HIV-1-infected cells, probably through direct targeting of the rVSV and VSV-mediated cytolysis and/or through syncytium formation- or cell-cell fusion-dependent killing, and markedly inhibited HIV-1 production. Furthermore, G-complemented VSVΔG-CC5 also efficiently inhibited HIV-1 infection in R5 HIV-1-infected humanized immunodeficient mice. Taken together, our findings indicate that a cytolytic rVSV that targets and eliminates R5 HIV-1-infected cells potentially has therapeutic value for controlling R5 HIV-1 infection.


Assuntos
Antígenos CD4/genética , Infecções por HIV/prevenção & controle , Terapia Viral Oncolítica/métodos , Receptores CCR5/genética , Vesiculovirus/genética , Proteínas do Envelope Viral/genética , Replicação Viral/genética , Animais , Antivirais/farmacologia , Antígenos CD4/metabolismo , Linfócitos T CD4-Positivos/metabolismo , Linfócitos T CD4-Positivos/virologia , Linhagem Celular , Cricetinae , Células HEK293 , Infecções por HIV/virologia , HIV-1/genética , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Receptores CCR5/metabolismo , Receptores CXCR4/metabolismo , Carga Viral
2.
Jpn J Infect Dis ; 68(3): 203-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25672345

RESUMO

To develop surrogate viruses for hepatitis C virus (HCV), we previously produced recombinant vesicular stomatitis viruses (rVSVs) lacking glycoprotein G but instead expressing chimeric HCV E1/E2 fused to G. These rVSVs were not infectious in HCV-susceptible hepatoma cells. In this study, to develop an infectious surrogate HCV based on an rVSV (vesicular stomatitis virus [VSV]/HCV), we generated a novel rVSV encoding the native E1/E2 (H77 strain) and green fluorescent protein (GFP) instead of G. Here, we showed that this VSV/HCV efficiently infected human hepatoma cells, including Huh7 human hepatoma cells, expressed GFP in these cells, and propagated, but did not do so in nonsusceptible BHK-21 cells. The infectivity of VSV/HCV, measured as the number of foci of GFP-positive cells, was specifically reduced by the addition of chimpanzee anti-HCV serum, anti-E2 antibody, or anti-CD81 antibody to the cultures. When sera obtained from HCV-infected or uninfected patients were added, infection was selectively inhibited only by the sera of HCV-infected patients. These data together suggest that this infectious GFP-expressing VSV/HCV could be a useful tool for studying the mechanisms of HCV entry into cells and for assessing potential inhibitors of viral entry, including neutralizing antibodies.


Assuntos
Proteínas de Fluorescência Verde/genética , Hepacivirus/genética , Modelos Biológicos , Estomatite Vesicular/genética , Proteínas do Envelope Viral/genética , Animais , Linhagem Celular , Cricetinae , Proteínas de Fluorescência Verde/metabolismo , Hepacivirus/metabolismo , Hepatite C/virologia , Humanos , Proteínas do Envelope Viral/metabolismo
3.
J Clin Microbiol ; 51(7): 2238-44, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23658266

RESUMO

The performance of hepatitis B surface antigen (HBsAg) screening assays is continuously improved to reduce the risk of transfusion-associated hepatitis B. In this study, a semiautomated immune complex transfer chemiluminescence enzyme immunoassay (ICT-CLEIA) for the detection of HBsAg, which is as sensitive as hepatitis B virus (HBV) DNA PCR, was developed; the ICT-CLEIA assay performance was compared with the performance of the Architect HBsAg QT assay and HBV DNA PCR. The specificities in the initial assay and after retesting were 99.50% (1,988/1,998 samples) and 99.95% (1,997/1,998 samples), respectively. The analytical detection limit was determined to be 0.2 mIU/ml using the 2nd International WHO HBsAg standard, and the cutoff value (0.5 mIU/ml) of the ICT-CLEIA assay was 8.0 standard deviations (SD) above the mean of the HBsAg-negative specimens. The ICT-CLEIA assay could detect HBsAg even in the presence of anti-HBs antibodies and demonstrated a 23.6-day-shorter window period using commercially available HBsAg seroconversion panels than the Architect HBsAg QT assay. Furthermore, the monitoring of the viral kinetics by the ICT-CLEIA assay and the HBV DNA PCR produced very similarly shaped curves during both the HBsAg seroconversion and reverse seroconversion periods. Therefore, the ICT-CLEIA assay may be useful not only for an earlier detection of HBV reactivation but also for the monitoring of hepatitis B patients.


Assuntos
Técnicas de Laboratório Clínico/métodos , Antígenos de Superfície da Hepatite B/sangue , Hepatite B/diagnóstico , Técnicas Imunoenzimáticas/métodos , Complexo Antígeno-Anticorpo/imunologia , Humanos , Luminescência , Sensibilidade e Especificidade
4.
Int J Nephrol ; 2012: 239476, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23193472

RESUMO

Hepcidin is the key mediator of renal anemia, and reliable measurement of serum hepcidin levels has been made possible by the ProteinChip system. We therefore investigated the iron status and serum hepcidin levels of peritoneal dialysis (PD) patients who had not received frequent doses of an erythrocytosis-stimulating agent (ESA) and had not received iron therapy. In addition to the usual iron parameters, the iron status of erythrocytes can be determined by measuring reticulocyte hemoglobin (RET-He). The mean serum hepcidin level of the PD patients (n = 52) was 80.7 ng/mL. Their serum hepcidin levels were significantly positively correlated with their serum ferritin levels and transferrin saturation (TSAT) levels, but no correlations were found between their serum hepcidin levels and RET-He levels, thereby suggesting that hepcidin has no effect on the iron dynamics of reticulocytes. Since low serum levels of CRP and IL-6, biomarkers of inflammation, were not correlated with the serum hepcidin levels, there is likely to be a threshold for induction of hepcidin expression by inflammation.

5.
Hum Immunol ; 72(4): 295-304, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21262309

RESUMO

OX40 protein is highly expressed on activated CD4-positive T cells that are susceptible for human immunodeficiency virus type 1 (HIV-1) infection. To target and kill HIV-1-infected OX40(+) T cells, we used a recombinant vesicular stomatitis virus (rVSV) lacking its envelope glycoprotein (ΔG) and instead expressing HIV-1 receptors CD4/CXCR4 and OX40 ligand (OX40L). Expression of OX40L as well as HIV-1 receptors on the VSV particles led to specific infection of OX40(+) T cells, including primary cells, either acutely or chronically infected with X4 HIV-1. Consequently, the rVSV rapidly eliminated these infected cells and caused a marked reduction of HIV-1 viral load in culture. Inclusion of the OX40L gene in the VSV recombinant led to significantly better infection and HIV-1 elimination compared with an rVSVΔG expressing only HIV-1 receptors. A novel rVSVΔG encoding both HIV-1 receptors and OX40L has a potentially greater therapeutic value than an rVSVΔG expressing only HIV-1 receptors.


Assuntos
Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD4-Positivos/virologia , Infecções por HIV , HIV-1/imunologia , Ligante OX40/imunologia , Receptores OX40/imunologia , Vesiculovirus/metabolismo , Animais , Antígenos CD4/genética , Antígenos CD4/imunologia , Antígenos CD4/metabolismo , Linhagem Celular , Linhagem Celular Tumoral , Cricetinae , Ordem dos Genes , Vetores Genéticos/genética , Vetores Genéticos/isolamento & purificação , Vetores Genéticos/metabolismo , Células Gigantes/metabolismo , Células Gigantes/patologia , Células HEK293 , Infecções por HIV/imunologia , Infecções por HIV/virologia , HIV-1/metabolismo , Humanos , Ligante OX40/genética , Receptores CXCR4/genética , Receptores CXCR4/imunologia , Receptores CXCR4/metabolismo , Vesiculovirus/genética , Vesiculovirus/isolamento & purificação , Carga Viral
6.
Clin Appl Thromb Hemost ; 11(3): 253-61, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16015410

RESUMO

Reticulated platelets (RP) and large platelets (LP) were measured by an automated hematology analyzer (modified R-2000) in 287 healthy volunteers and 131 patients with thrombocytopenia or thrombocytosis. RP was significantly higher in patients with idiopathic thrombocytopenic purpura (ITP), especially in active phase, while RP was markedly lower in patients with essential thrombocytosis (ET) or chronic myelocytic leukemia (CML). LP was significantly higher in patients with ITP, especially in active phase, while LP was markedly lower in patients with aplastic anemia (AA), ET, or CML. In ITP, RP and LP were significantly higher in patients positive for anti-glycoprotein (Gp) IIb/IIIa antibody. RP and LP were poorly correlated with platelet-associated IgG (PAIgG). RP and LP were poorly correlated with plasma thrombopoietin levels, and negatively correlated with platelet count. These results show that RP reflects the pathology of thrombocytopenic disorders, and that measurement of RP is useful for the differential diagnosis and analysis of platelet kinetics.


Assuntos
Contagem de Plaquetas , Púrpura Trombocitopênica Idiopática/diagnóstico , Adulto , Plaquetas/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Púrpura Trombocitopênica Idiopática/sangue , Valores de Referência , Trombocitopenia/sangue , Trombocitopenia/diagnóstico
7.
Cytometry B Clin Cytom ; 66(1): 18-24, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15800879

RESUMO

BACKGROUND: For the diagnosis and therapy of acute leukemia, it is important to detect a small number of leukemic cells precisely. Although several automated hematology analyzers that carry blast-detecting programs have been developed, they do not exert sufficient detection sensitivity to exceed the sensitivity of manual eye counting method. METHODS: We constructed a new blast-detecting program by combining the numerical information acquired from five cytometric parameters presented by XE-2100. The sensitivity and specificity of this blast multi-scoring program were assessed in comparison with the Blasts flag program equipped originally in XE-2100. RESULTS: The blast-detecting sensitivity was found to be highly improved in the blast multi-scoring program as compared with the Blasts flag program without much decreasing the specificity. A small number of leukemic myeloblasts was detected at the better sensitivity than the eye counting method in the clinical course of the patients with acute myeloid leukemia. CONCLUSIONS: The daily practical use of this blast multi-scoring program will surely contribute to sensitive, objective, and real-time evaluation of the control of acute myeloid leukemia with a low cost.


Assuntos
Testes Hematológicos/métodos , Hematologia/métodos , Leucemia Mieloide/diagnóstico , Doença Aguda , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Contagem de Eritrócitos/instrumentação , Contagem de Eritrócitos/métodos , Feminino , Testes Hematológicos/instrumentação , Hematologia/instrumentação , Humanos , Leucemia Mieloide/sangue , Leucemia Mieloide/tratamento farmacológico , Contagem de Leucócitos/instrumentação , Contagem de Leucócitos/métodos , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas/instrumentação , Contagem de Plaquetas/métodos , Sensibilidade e Especificidade
8.
Int J Hematol ; 80(3): 254-60, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15540901

RESUMO

CD26/dipeptidyl peptidase IV (DPPIV), a T-cell-activation antigen, is a 110-kD type II surface glycoprotein expressed on various types of normal cells. CD26/DPPIV is considered a multifunction housekeeping protein. Malignant cells often show altered CD26/DPPIV expression or no CD26/DPPIV expression, thus suggesting a useful marker for assessing some T-cell malignancies. In this study, cell surface protein and messenger RNA expression profiles for CD26/DPPIV were examined in 49 patients with adult T-cell leukemia (ATL), 10 carriers of human T-lymphotropic virus I (HTLV-I), and 4 HTLV-I-infected cell lines to assess the utility of CD26/DPPIV expression as a useful molecular marker for ATL pathology. In contrast to normal lymphocytes, ATL cells and HTLV-I-infected cell lines apparently down-regulated or completely lost the CD26/DPPIV antigen. Furthermore, the positive rate and antigen density for CD26/DPPIV in ATL cells gradually declined along with the advancement of ATL stage. Analysis of genomic DNA and the CD26/DPPIV transcript showed that CD26- ATL cells possessed faintly detected transcripts of the gene that were aberrantly methylated at the CpG islands within the promoter region in parallel with the advancement of ATL, a finding supported by a rescue experiment for transcript reexpression using 5-azacytidine as demethylation agent. Moreover, there was no relationship between loss of CD26/DPPIV and HTLV-I tax expression. These results indicate that ATL cells down-regulate CD26 antigens by means of epigenetic machinery and that this antigen abnormality is a useful molecular marker for the pathology of ATL.


Assuntos
Dipeptidil Peptidase 4/genética , Regulação Neoplásica da Expressão Gênica , Leucemia-Linfoma de Células T do Adulto/genética , Biomarcadores , Estudos de Casos e Controles , Ilhas de CpG , Metilação de DNA , Dipeptidil Peptidase 4/análise , Regulação para Baixo , Epigênese Genética , Perfilação da Expressão Gênica , Humanos , Leucemia-Linfoma de Células T do Adulto/diagnóstico , Regiões Promotoras Genéticas , RNA/análise
9.
Cytometry B Clin Cytom ; 58(1): 25-31, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-14994372

RESUMO

BACKGROUND: Attempts to analyze bone marrow aspirates have been reported with the use of several automated blood cell counters, but sufficient accuracy in examination is not acquired yet. Major problems have included difficulties in correctly differentiating various immature cells and interference by lipid in bone marrow aspirates. The goal of this study was to solve these problems to attain more accurate assessment of bone marrow aspirates with automated blood cell counters. METHODS: We modified the XE-2100 Automated Hematology Analyzer (Sysmex Corporation, Kobe, Japan) to fit it for bone marrow aspirate measurement and evaluated its performance. Measurements were performed with the modified XE-2100 on 81 patient samples of bone marrow aspirates; as a reference, the manual visual method was used and flow cytometric analysis were carried out. RESULTS: Good correlations between results with the modified XE-2100 and the manual visual method were obtained for total nucleated cell count (TNCC; r = 0.99), erythroblast/TNCC ratio (r = 0.93), and myeloid cell/TNCC ratio (r = 0.75). CONCLUSIONS: When this device is used, bone marrow aspirate differentials can be determined quickly and easily. This device will be useful for preliminary examination to obtain a summary of various blood cell ratios in bone marrow aspirates before performance of microscopic examination.


Assuntos
Automação/métodos , Biópsia por Agulha/métodos , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , Células da Medula Óssea/citologia , Exame de Medula Óssea/instrumentação , Exame de Medula Óssea/métodos , Células Eritroides/citologia , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Humanos , Células Mieloides/citologia , Sensibilidade e Especificidade
10.
Lab Hematol ; 9(3): 117-24, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14521317

RESUMO

We evaluated an automated immature granulocyte (IG) count in the peripheral blood with the XE-IG Master (Sysmex Corporation). The XE-IG Master is the upgraded software package for the XE-2100 automated hematology analyzer. Reproducibility tests demonstrated a mean coefficient of variation of 7.02% for the IG percentage (IG%) and 6.93% for the absolute IG count. Correlations of the IG counts were assessed in two ways. A flow cytometric IG count using CD11b, CD16, and CD45 monoclonal antibodies and a manual differential count were used as reference methods. The regression equation and the correlation coefficient of the IG% for the flow cytometric reference count versus results with the XE-IG Master were: y = 0.91x + 0.10; r = 0.96. For the comparison with the manual differential count of promyelocytes, myelocytes, and metamyelocytes, the regression equation and correlation coefficient were: y = 0.81x + 1.27; r = 0.78. Samples were found to be stable up to 48 hours both at room temperature and when refrigerated. We investigated the clinical significance of the IG count as a new marker of acute inflammation. In this preliminary study, most samples with a high IG count had positive values for C-reactive protein and the erythrocyte sedimentation rate (positive sample rates were 84.0% and 95.0%, respectively) despite neutrophil counts within the normal range. Elevated IG counts correlated most closely with CD64 expression on polymorphonuclear cells and less so with the concentration of interleukin 6. Compared with other available inflammation markers, the IG count is rapidly generated with each full blood count at no extra cost and with no delay in sample analysis.


Assuntos
Granulócitos/citologia , Contagem de Leucócitos/instrumentação , Software , Doença Aguda , Estudos de Casos e Controles , Granulócitos/patologia , Humanos , Inflamação/diagnóstico , Inflamação/patologia , Interleucina-6/análise , Contagem de Leucócitos/normas , Receptores de IgG/análise , Reprodutibilidade dos Testes
11.
Arch Pathol Lab Med ; 127(1): e4-10, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12562284

RESUMO

During differentiation-induction therapy of acute promyelocytic leukemia (APL) patients with all-trans retinoic acid (ATRA), a variety of APL-derived bizarre granulocytic cells appear in the peripheral blood. To evaluate the differentiation induction of leukemic cells, we have developed a new scattergram analyzing program with an automated hematology analyzer and compared the data with the flow cytometry measuring the expression of differentiation-associated cell surface antigens, CD11b and CD16. We used the fluorescence intensity and side scatter as parameters of granulocytic maturation in the analysis with the automated hematology analyzer. The analysis of 2 ATRA-treated APL patients and in vitro study using HL-60 cells demonstrated that the levels of fluorescence intensity and side scatter decreased as accompanied with granulocytic maturation, and these changes were parallel with the results of flow cytometry. Our automated scattergram analysis of cell differentiation will contribute to general, objective, and real-time evaluation of differentiation-induction therapy of APL with ATRA.


Assuntos
Antineoplásicos/uso terapêutico , Citofotometria/métodos , Testes Hematológicos/métodos , Leucemia Promielocítica Aguda/tratamento farmacológico , Tretinoína/uso terapêutico , Adulto , Automação , Antígeno CD11b/análise , Diferenciação Celular/efeitos dos fármacos , Feminino , Citometria de Fluxo , Fluorescência , Granulócitos/química , Granulócitos/classificação , Granulócitos/efeitos dos fármacos , Células HL-60 , Humanos , Leucemia Promielocítica Aguda/diagnóstico , Leucemia Promielocítica Aguda/patologia , Masculino , Pessoa de Meia-Idade , Receptores de IgG/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA