Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 90(6): 2334-2347, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37533368

RESUMO

PURPOSE: To demonstrate the feasibility of a multi-breath xenon-polarization transfer contrast (XTC) MR imaging approach for simultaneously evaluating regional ventilation and gas exchange parameters. METHODS: Imaging was performed in five healthy volunteers and six chronic obstructive pulmonary disease (COPD) patients. The multi-breath XTC protocol consisted of three repeated schemes of six wash-in breaths of a xenon mixture and four normoxic wash-out breaths, with and without selective saturation of either the tissue membrane or red blood cell (RBC) resonances. Acquisitions were performed at end-exhalation while subjects maintained tidal breathing throughout the session. The no-saturation, membrane-saturation, and RBC-saturation images were fit to a per-breath gas replacement model for extracting voxelwise tidal volume (TV), functional residual capacity (FRC), and fractional ventilation (FV), as well as tissue- and RBC-gas exchange (fMem and fRBC , respectively). The sensitivity of the derived model was also evaluated via simulations. RESULTS: With the exception of FRC, whole-lung averages for all metrics were decreased in the COPD subjects compared to the healthy cohort, significantly so for FV, fRBC , and fMem . Heterogeneity was higher overall in the COPD subjects, particularly for fRBC , fMem , and fRBC:Mem . The anterior-to-posterior gradient associated with the gravity-dependence of lung function in supine imaging was also evident for FV, fRBC , and fMem values in the healthy subjects, but noticeably absent in the COPD cohort. CONCLUSION: Multi-breath XTC imaging generated high-resolution, co-registered maps of ventilation and gas exchange parameters acquired during tidal breathing and with low per-breath xenon doses. Clear differences between healthy and COPD subjects were apparent and consistent with spirometry.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Xenônio , Humanos , Pulmão/diagnóstico por imagem , Isótopos de Xenônio , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
2.
Am J Physiol Lung Cell Mol Physiol ; 322(6): L866-L872, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35438574

RESUMO

Imatinib, a tyrosine kinase inhibitor, attenuates pulmonary edema and inflammation in lung injury. However, the physiological effects of this drug and their impact on outcomes are poorly characterized. Using serial computed tomography (CT), we tested the hypothesis that imatinib reduces injury severity and improves survival in ventilated rats. Hydrochloric acid (HCl) was instilled in the trachea (pH 1.5, 2.5 mL/kg) of anesthetized, intubated supine rats. Animals were randomized (n = 17 each group) to receive intraperitoneal imatinib or vehicle immediately prior to HCl. All rats then received mechanical ventilation. CT was performed hourly for 4 h. Images were quantitatively analyzed to assess the progression of radiological abnormalities. Injury severity was confirmed via hourly blood gases, serum biomarkers, bronchoalveolar lavage (BAL), and histopathology. Serial blood drug levels were measured in a subset of rats. Imatinib reduced mortality while delaying functional and radiological injury progression: out of 17 rats per condition, 2 control vs. 8 imatinib-treated rats survived until the end of the experiment (P = 0.02). Imatinib attenuated edema after lung injury (P < 0.05), and survival time in both groups was negatively correlated with increased lung mass (R2 = 0.70) as well as other physiological and CT parameters. Capillary leak (BAL protein concentration) was significantly lower in the treated group (P = 0.04). Peak drug concentration was reached after 70 min, and the drug half-life was 150 min. Imatinib decreased both mortality and lung injury severity in mechanically ventilated rats. Pharmacological inhibition of edema could be used during mechanical ventilation to improve the severity and outcome of lung injury.


Assuntos
Lesão Pulmonar , Edema Pulmonar , Animais , Ácido Clorídrico , Mesilato de Imatinib/farmacologia , Pulmão/patologia , Lesão Pulmonar/tratamento farmacológico , Lesão Pulmonar/patologia , Edema Pulmonar/patologia , Ratos , Respiração Artificial
4.
Crit Care Med ; 49(10): e1015-e1024, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33938714

RESUMO

OBJECTIVES: It is not known how lung injury progression during mechanical ventilation modifies pulmonary responses to prone positioning. We compared the effects of prone positioning on regional lung aeration in late versus early stages of lung injury. DESIGN: Prospective, longitudinal imaging study. SETTING: Research imaging facility at The University of Pennsylvania (Philadelphia, PA) and Medical and Surgical ICUs at Massachusetts General Hospital (Boston, MA). SUBJECTS: Anesthetized swine and patients with acute respiratory distress syndrome (acute respiratory distress syndrome). INTERVENTIONS: Lung injury was induced by bronchial hydrochloric acid (3.5 mL/kg) in 10 ventilated Yorkshire pigs and worsened by supine nonprotective ventilation for 24 hours. Whole-lung CT was performed 2 hours after hydrochloric acid (Day 1) in both prone and supine positions and repeated at 24 hours (Day 2). Prone and supine images were registered (superimposed) in pairs to measure the effects of positioning on the aeration of each tissue unit. Two patients with early acute respiratory distress syndrome were compared with two patients with late acute respiratory distress syndrome, using electrical impedance tomography to measure the effects of body position on regional lung mechanics. MEASUREMENTS AND MAIN RESULTS: Gas exchange and respiratory mechanics worsened over 24 hours, indicating lung injury progression. On Day 1, prone positioning reinflated 18.9% ± 5.2% of lung mass in the posterior lung regions. On Day 2, position-associated dorsal reinflation was reduced to 7.3% ± 1.5% (p < 0.05 vs Day 1). Prone positioning decreased aeration in the anterior lungs on both days. Although prone positioning improved posterior lung compliance in the early acute respiratory distress syndrome patients, it had no effect in late acute respiratory distress syndrome subjects. CONCLUSIONS: The effects of prone positioning on lung aeration may depend on the stage of lung injury and duration of prior ventilation; this may limit the clinical efficacy of this treatment if applied late.


Assuntos
Lesão Pulmonar/complicações , Decúbito Ventral/fisiologia , Adulto , Idoso , Boston , Feminino , Humanos , Estudos Longitudinais , Lesão Pulmonar/diagnóstico por imagem , Lesão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pennsylvania , Respiração com Pressão Positiva/métodos , Estudos Prospectivos , Resultado do Tratamento
5.
Magn Reson Med ; 85(5): 2709-2722, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33283943

RESUMO

PURPOSE: To demonstrate the feasibility of generating red blood cell (RBC) and tissue/plasma (TP)-specific gas-phase (GP) depolarization maps using xenon-polarization transfer contrast (XTC) MR imaging. METHODS: Imaging was performed in three healthy subjects, an asymptomatic smoker, and a chronic obstructive pulmonary disease (COPD) patient. Single-breath XTC data were acquired through a series of three GP images using a 2D multi-slice GRE during a 12 s breath-hold. A series of 8 ms Gaussian inversion pulses spaced 30 ms apart were applied in-between the images to quantify the exchange between the GP and dissolved-phase (DP) compartments. Inversion pulses were either centered on-resonance to generate contrast, or off-resonance to correct for other sources of signal loss. For an alternative scheme, inversions of both RBC and TP resonances were inserted in lieu of off-resonance pulses. Finally, this technique was extended to a multi-breath protocol consistent with tidal breathing, involving 30 consecutive acquisitions. RESULTS: Inversion pulses shifted off-resonance by 20 ppm to mimic the distance between the RBC and TP resonances demonstrated selectivity, and initial GP depolarization maps illustrated stark magnitude and distribution differences between healthy and diseased subjects that were consistent with traditional approaches. CONCLUSION: The proposed DP-compartment selective XTC MRI technique provides information on gas exchange between all three detectable states of xenon in the lungs and is sufficiently sensitive to indicate differences in lung function between the study subjects. Investigated extensions of this approach to imaging schemes that either minimize breath-hold duration or the overall number of breath-holds open avenues for future research to improve measurement accuracy and patient comfort.


Assuntos
Troca Gasosa Pulmonar , Isótopos de Xenônio , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Xenônio
6.
NMR Biomed ; 33(11): e4380, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32681670

RESUMO

Increased pulmonary lactate production is correlated with severity of lung injury and outcome in acute respiratory distress syndrome (ARDS) patients. This study was conducted to investigate the relative contributions of inflammation and hypoxia to the lung's metabolic shift to glycolysis in an experimental animal model of ARDS using hyperpolarized (HP) 13 C MRI. Fifty-three intubated and mechanically ventilated male rats were imaged using HP 13 C MRI before, and 1, 2.5 and 4 hours after saline (sham) or hydrochloric acid (HCl; 0.5 ml/kg) instillation in the trachea, followed by protective and nonprotective mechanical ventilation (HCl-PEEP and HCl-ZEEP) or the start of moderate or severe hypoxia (Hyp90 and Hyp75 groups). Pulmonary and cardiac HP lactate-to-pyruvate ratios were compared among groups for different time points. Postmortem histology and immunofluorescence were used to assess lung injury severity and quantify the expression of innate inflammatory markers and local tissue hypoxia. HP pulmonary lactate-to-pyruvate ratio progressively increased in rats with lung injury and moderate hypoxia (HCl-ZEEP), with no significant change in pulmonary lactate-to-pyruvate ratio in noninjured but moderately hypoxic rats (Hyp90). Pulmonary lactate-to-pyruvate ratio was elevated in otherwise healthy lung tissue only in severe systemic hypoxia (Hyp75 group). ex vivo histological and immunopathological assessment further confirmed the link between elevated glycolysis and the recruitment into and presence of activated neutrophils in injured lungs. HP lactate-to-pyruvate ratio is elevated in injured lungs predominantly as a result of increased glycolysis in activated inflammatory cells, but can also increase due to severe inflammation-induced hypoxia.


Assuntos
Lesão Pulmonar/metabolismo , Pulmão/metabolismo , Pneumonia/metabolismo , Ácido Pirúvico/metabolismo , Síndrome do Desconforto Respiratório/metabolismo , Animais , Modelos Animais de Doenças , Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Molécula 1 de Adesão Intercelular/metabolismo , Ácido Láctico/metabolismo , Lesão Pulmonar/complicações , Masculino , Peroxidase/metabolismo , Pneumonia/complicações , Ratos Sprague-Dawley , Síndrome do Desconforto Respiratório/complicações
7.
IEEE Trans Med Imaging ; 38(9): 2081-2091, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30990426

RESUMO

Hyperpolarized 129Xe magnetic resonance imaging is a powerful modality capable of assessing lung structure and function. While it has shown promise as a clinical tool for the longitudinal assessment of lung function, its utility as an investigative tool for animal models of pulmonary diseases is limited by the necessity of invasive intubation and mechanical ventilation procedures. In this paper, we overcame this limitation by developing a gas delivery system and implementing a set of imaging schemes to acquire high-resolution gas- and dissolved-phase images in free-breathing mice. Gradient echo pulse sequences were used to acquire both high- and low-resolution gas-phase images, and regional fractional ventilation was quantified by comparing signal buildup among low-resolution gas-phase images acquired at two flip-angles. Dissolved-phase images were acquired using both ultra-short echo time and chemical shift imaging sequences with discrete sets of flip-angle/repetition time combinations to visualize gas uptake and distribution throughout the body. Spectral features distinct to various anatomical regions were identified in images acquired using the latter sequence and were used for the quantification of gas arrival times for respective compartments.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pulmão , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio , Animais , Desenho de Equipamento , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Camundongos , Camundongos Endogâmicos C57BL , Respiração , Isótopos de Xenônio/administração & dosagem , Isótopos de Xenônio/química
8.
Sci Rep ; 9(1): 2413, 2019 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-30787357

RESUMO

While hyperpolarized xenon-129 (HXe) MRI offers a wide array of tools for assessing functional aspects of the lung, existing techniques provide only limited quantitative information about the impact of an observed pathology on overall lung function. By selectively destroying the alveolar HXe gas phase magnetization in a volume of interest and monitoring the subsequent decrease in the signal from xenon dissolved in the blood inside the left ventricle of the heart, it is possible to directly measure the contribution of that saturated lung volume to the gas transport capacity of the entire lung. In mechanically ventilated rabbits, we found that both xenon gas transport and transport efficiency exhibited a gravitation-induced anterior-to-posterior gradient that disappeared or reversed direction, respectively, when the animal was turned from supine to prone position. Further, posterior ventilation defects secondary to acute lung injury could be re-inflated by applying positive end expiratory pressure, although at the expense of decreased gas transport efficiency in the anterior volumes. These findings suggest that our technique might prove highly valuable for evaluating lung transplants and lung resections, and could improve our understanding of optimal mechanical ventilator settings in acute lung injury.


Assuntos
Gases/metabolismo , Coração/fisiologia , Pulmão/metabolismo , Troca Gasosa Pulmonar/fisiologia , Animais , Ventrículos do Coração/efeitos dos fármacos , Humanos , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Decúbito Ventral , Coelhos , Respiração Artificial , Função Ventricular/fisiologia , Isótopos de Xenônio/farmacologia
9.
Acad Radiol ; 26(3): 383-394, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30087068

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to assess the effectiveness of hyperpolarized helium-3 magnetic resonance (MR)-based imaging markers in predicting future forced expiratory volume in one second decline/chronic obstructive pulmonary disorder progression in smokers compared to current diagnostic techniques. MATERIALS AND METHODS: Total 60 subjects (15 nonsmokers and 45 smokers) participated in both baseline and follow-up visits (∼1.4 years apart). At both visits, subjects completed pulmonary function testing, a six-minute walk test , and the St. George Respiratory Questionnaire. Using helium-3 MR imaging, means (M) and standard deviations (H) of oxygen tension (PAO2), fractional ventilation, and apparent diffusion coefficient were calculated across 12 regions of interest in the lungs. Subjects who experienced FEV1 decline >100 mL/year were deemed "decliners," while those who did not were deemed "sustainers." Nonimaging and imaging prediction models were generated through a logistic regression model, which utilized measurements from sustainers and decliners. RESULTS: The nonimaging prediction model included the St. George Respiratory Questionnaire total score, diffusing capacity of carbon monoxide by the alveolar volume (DLCO/VA), and distance walked in a six-minute walk test. A receiving operating character curve for this model yielded a sensitivity of 75% and specificity of 68% with an overall area under the curve of 65%. The imaging prediction model generated following the same methodology included ADCH, FVH, and PAO2H. The resulting receiving operating character curve yielded a sensitivity of 87.5%, specificity of 82.8%, and an area under the curve of 89.7%. CONCLUSION: The imaging predication model generated from measurements obtained during 3He MR imaging is better able to predict future FEV1 decline compared to one based on current clinical tests and demographics. The imaging model's superiority appears to arise from its ability to distinguish well-circumscribed, severe disease from a more uniform distribution of moderately altered lung function, which is more closely associated with subsequent FEV1 decline.


Assuntos
Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Fumar/fisiopatologia , Adulto , Área Sob a Curva , Estudos de Casos e Controles , Progressão da Doença , Volume Expiratório Forçado , Hélio , Humanos , Isótopos , Pessoa de Meia-Idade , Oxigênio , Pressão Parcial , Capacidade de Difusão Pulmonar , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Curva ROC , Teste de Caminhada
10.
Sci Rep ; 8(1): 7310, 2018 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-29743565

RESUMO

Many forms of lung disease manifest themselves as pathological changes in the transport of gas to the circulatory system, yet the difficulty of imaging this process remains a central obstacle to the comprehensive diagnosis of lung disorders. Using hyperpolarized xenon-129 as a surrogate marker for oxygen, we derived the temporal dynamics of gas transport from the ratio of two lung images obtained with different timing parameters. Additionally, by monitoring changes in the total hyperpolarized xenon signal intensity in the left side of the heart induced by depletion of xenon signal in the alveolar airspaces of interest, we quantified the contributions of selected lung volumes to the total pulmonary gas transport. In a rabbit model, we found that it takes at least 200 ms for xenon gas to enter the lung tissue and travel the distance from the airspaces to the heart. Additionally, our method shows that both lungs contribute fairly equally to the gas transport in healthy rabbits, but that this ratio changes in a rabbit model of acid aspiration. These results suggest that hyperpolarized xenon-129 MRI may improve our ability to measure pulmonary gas transport and detect associated pathological changes.


Assuntos
Imageamento por Ressonância Magnética , Troca Gasosa Pulmonar , Isótopos de Xenônio/metabolismo , Animais , Coelhos
11.
Magn Reson Med ; 80(6): 2439-2448, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29682792

RESUMO

PURPOSE: To demonstrate the feasibility of using a 3D radial double golden-means acquisition with variable flip angles to monitor pulmonary gas transport in a single breath hold with hyperpolarized xenon-129 MRI. METHODS: Hyperpolarized xenon-129 MRI scans with interleaved gas-phase and dissolved-phase excitations were performed using a 3D radial double golden-means acquisition in mechanically ventilated rabbits. The flip angle was either held fixed at 15 ° or 5 °, or it was varied linearly in ascending or descending order between 5 ° and 15 ° over a sampling interval of 1000 spokes. Dissolved-phase and gas-phase images were reconstructed at high resolution (32 × 32 × 32 matrix size) using all 1000 spokes, or at low resolution (22 × 22 × 22 matrix size) using 400 spokes at a time in a sliding-window fashion. Based on these sliding-window images, relative change maps were obtained using the highest mean flip angle as the reference, and aggregated pixel-based changes were tracked. RESULTS: Although the signal intensities in the dissolve-phase maps were mostly constant in the fixed flip-angle acquisitions, they varied significantly as a function of average flip angle in the variable flip-angle acquisitions. The latter trend reflects the underlying changes in observed dissolve-phase magnetization distribution due to pulmonary gas uptake and transport. CONCLUSION: 3D radial double golden-means acquisitions with variable flip angles provide a robust means for rapidly assessing lung function during a single breath hold, thereby constituting a particularly valuable tool for imaging uncooperative or pediatric patient populations.


Assuntos
Suspensão da Respiração , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Animais , Gases , Troca Gasosa Pulmonar , Coelhos , Respiração Artificial , Imagem Corporal Total , Isótopos de Xenônio
12.
Am J Physiol Lung Cell Mol Physiol ; 313(2): L305-L312, 2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28473321

RESUMO

During lung inflation, airspace dimensions are affected nonlinearly by both alveolar expansion and recruitment, potentially confounding the identification of emphysematous lung by hyperpolarized helium-3 diffusion magnetic resonance imaging (HP MRI). This study aimed to characterize lung inflation over a broad range of inflation volume and pressure values in two different models of emphysema, as well as in normal lungs. Elastase-treated rats (n = 7) and healthy controls (n = 7) were imaged with HP MRI. Gradual inflation was achieved by incremental changes to both inflation volume and airway pressure. The apparent diffusion coefficient (ADC) was measured at each level of inflation and fitted to the corresponding airway pressures as the second-order response equation, with minimizing residue (χ2 < 0.001). A biphasic ADC response was detected, with an initial ADC increase followed by a decrease at airway pressures >18 cmH2O. Discrimination between treated and control rats was optimal when airway pressure was intermediate (between 10 and 11 cmH2O). Similar findings were confirmed in mice following long-term exposure to cigarette smoke, where optimal discrimination between treated and healthy mice occurred at a similar airway pressure as in the rats. We subsequently explored the evolution of ADC measured at the intermediate inflation level in mice after prolonged smoke exposure and found a significant increase (P < 0.01) in ADC over time. Our results demonstrate that measuring ADC at intermediate inflation enhances the distinction between healthy and diseased lungs, thereby establishing a model that may improve the diagnostic accuracy of future HP gas diffusion studies.


Assuntos
Pulmão/patologia , Enfisema Pulmonar/patologia , Animais , Imagem de Difusão por Ressonância Magnética/métodos , Modelos Animais de Doenças , Hélio/química , Camundongos , Camundongos Endogâmicos C57BL , Elastase Pancreática/administração & dosagem , Pressão , Ratos , Ratos Sprague-Dawley , Fumaça/efeitos adversos
13.
Magn Reson Med ; 78(2): 611-624, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27734519

RESUMO

PURPOSE: To present a method for simultaneous acquisition of alveolar oxygen tension (PA O2 ), specific ventilation (SV), and apparent diffusion coefficient (ADC) of hyperpolarized (HP) gas in the human lung, allowing reinterpretation of the PA O2 and SV maps to produce a map of oxygen uptake (R). METHOD: An imaging scheme was designed with a series of identical normoxic HP gas wash-in breaths to measure ADC, SV, PA O2 , and R in less than 2 min. Signal dynamics were fit to an iterative recursive model that regionally solved for these parameters. This measurement was successfully performed in 12 subjects classified in three healthy, smoker, and chronic obstructive pulmonary disease (COPD) cohorts. RESULTS: The overall whole lung ADC, SV, PA O2 , and R in healthy, smoker, and COPD subjects was 0.20 ± 0.03 cm2 /s, 0.39 ± 0.06,113 ± 2 Torr, and 1.55 ± 0.35 Torr/s, respectively, in healthy subjects; 0.21 ± 0.03 cm2 /s, 0.33 ± 0.06, 115.9 ± 4 Torr, and 0.97 ± 0.2 Torr/s, respectively, in smokers; and 0.25 ± 0.06 cm2 /s, 0.23 ± 0.08, 114.8 ± 6.0Torr, and 0.94 ± 0.12 Torr/s, respectively, in subjects with COPD. Hetrogeneity of SV, PA O2 , and R were indicators of both smoking-related changes and disease, and the severity of the disease correlated with the degree of this heterogeneity. Subjects with symptoms showed reduced oxygen uptake and specific ventilation. CONCLUSION: High-resolution, nearly coregistered and quantitative measures of lung function and structure were obtained with less than 1 L of HP gas. This hybrid multibreath technique produced measures of lung function that revealed clear differences among the cohorts and subjects and were confirmed by correlations with global lung measurements. Magn Reson Med 78:611-624, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Oxigênio/metabolismo , Alvéolos Pulmonares/diagnóstico por imagem , Alvéolos Pulmonares/metabolismo , Trítio/metabolismo , Adulto , Suspensão da Respiração , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Respiração
14.
Radiology ; 279(3): 917-24, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26785042

RESUMO

Purpose To assess the feasibility and optimize the accuracy of the multibreath wash-in hyperpolarized helium 3 ((3)He) approach to ventilation measurement by using magnetic resonance (MR) imaging as well as to examine the physiologic differences that this approach reveals among nonsmokers, asymptomatic smokers, and patients with chronic obstructive pulmonary disease (COPD). Materials and Methods All experiments were approved by the local institutional review board and compliant with HIPAA. Informed consent was obtained from all subjects. To measure fractional ventilation, the authors administered a series of identical normoxic hyperpolarized gas breaths to the subject; after each inspiration, an image was acquired during a short breath hold. Signal intensity buildup was fit to a recursive model that regionally solves for fractional ventilation. This measurement was successfully performed in nine subjects: three healthy nonsmokers (one man, two women; mean age, 45 years ± 4), three asymptomatic smokers (three men; mean age, 51 years ± 5), and three patients with COPD (three men; mean age, 59 years ± 5). Repeated measures analysis of variance was performed, followed by post hoc tests with Bonferroni correction, to assess the differences among the three cohorts. Results Whole-lung fractional ventilation as measured with hyperpolarized (3)He in all subjects (mean, 0.24 ± 0.06) showed a strong correlation with global fractional ventilation as measured with a gas delivery device (R(2) = 0.96, P < .001). Significant differences between the means of whole-lung fractional ventilation (F2,10 = 7.144, P = .012) and fractional ventilation heterogeneity (F2,10 = 7.639, P = .010) were detected among cohorts. In patients with COPD, the protocol revealed regions wherein fractional ventilation varied substantially over multiple breaths. Conclusion Multibreath wash-in hyperpolarized (3)He MR imaging of fractional ventilation is feasible in human subjects and demonstrates very good global (whole-lung) precision. Fractional ventilation measurement with this physiologically realistic approach reveals significant differences between patients with COPD and healthy subjects. To minimize error, several sources of potential bias must be corrected when calculating fractional ventilation. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Hélio/administração & dosagem , Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Fumar/fisiopatologia , Adulto , Biomarcadores/análise , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Hélio/análise , Humanos , Pulmão/fisiologia , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Processamento de Sinais Assistido por Computador
15.
Magn Reson Med ; 76(4): 1092-101, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26467179

RESUMO

PURPOSE: This study tested the ability of a multibreath hyperpolarized HP (3) He MRI protocol to increase the accuracy of regional alveolar oxygen tension (PA O2 ) measurements by lessening the influence of gas-flow artifacts. Conventional single-breath PA O2 measurement has been susceptible to error induced by intervoxel gas flow, particularly when used to study subjects with moderate-to-severe chronic obstructive pulmonary disease (COPD). METHODS: Both single-breath and multibreath PA O2 imaging schemes were implemented in seven human subjects (one healthy, three asymptomatic smokers, and three COPD). The number and location of voxels with nonphysiologic PA O2 values generated by intervoxel gas flow were compared between the two protocols. RESULTS: The multibreath scheme resulted in a significantly lower total percentage of nonphysiologic PA O2 values (6.0%) than the single-breath scheme (13.7%) (P = 0.006). PA O2 maps showed several patterns of gas-flow artifacts that were present in the single-breath protocol but mitigated by the multibreath approach. Multibreath imaging also allowed for the analysis of slow-filling areas that presented no signal after a single breath. CONCLUSION: A multibreath approach enhances the accuracy and completeness of noninvasive PA O2 measurement by significantly lessening the proportion of nonphysiologic values generated by intervoxel gas flow. Magn Reson Med 76:1092-1101, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Hélio/farmacocinética , Isótopos/farmacocinética , Imageamento por Ressonância Magnética/métodos , Consumo de Oxigênio/fisiologia , Oxigênio/metabolismo , Alvéolos Pulmonares/fisiologia , Troca Gasosa Pulmonar/fisiologia , Mecânica Respiratória/fisiologia , Administração por Inalação , Adulto , Hélio/administração & dosagem , Humanos , Isótopos/administração & dosagem , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Testes de Função Respiratória/métodos , Sensibilidade e Especificidade
16.
J Appl Physiol (1985) ; 120(4): 444-54, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26662053

RESUMO

Inspiratory stretch by mechanical ventilation worsens lung injury. However, it is not clear whether and how the ventilator damages lungs in the absence of preexisting injury. We hypothesized that subtle loss of lung aeration during general anesthesia regionally augments ventilation and distension of ventilated air spaces. In eight supine anesthetized and intubated rats, hyperpolarized gas MRI was performed after a recruitment maneuver following 1 h of volume-controlled ventilation with zero positive end-expiratory pressure (ZEEP), FiO2 0.5, and tidal volume 10 ml/kg, and after a second recruitment maneuver. Regional fractional ventilation (FV), apparent diffusion coefficient (ADC) of (3)He (a measurement of ventilated peripheral air space dimensions), and gas volume were measured in lung quadrants of ventral and dorsal regions of the lungs. In six additional rats, computed tomography (CT) images were obtained at each time point. Ventilation with ZEEP decreased total lung gas volume and increased both FV and ADC in all studied regions. Increases in FV were more evident in the dorsal slices. In each lung quadrant, higher ADC was predicted by lower gas volume and by increased mean values (and heterogeneity) of FV distribution. CT scans documented 10% loss of whole-lung aeration and increased density in the dorsal lung, but no macroscopic atelectasis. Loss of pulmonary gas at ZEEP increased fractional ventilation and inspiratory dimensions of ventilated peripheral air spaces. Such regional changes could help explain a propensity for mechanical ventilation to contribute to lung injury in previously uninjured lungs.


Assuntos
Pulmão/fisiologia , Troca Gasosa Pulmonar/fisiologia , Animais , Lesão Pulmonar/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Masculino , Respiração com Pressão Positiva/métodos , Atelectasia Pulmonar/fisiopatologia , Ratos , Ratos Sprague-Dawley , Respiração Artificial/métodos , Volume de Ventilação Pulmonar/fisiologia , Tomografia Computadorizada por Raios X/métodos
17.
Radiology ; 277(1): 247-58, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26110668

RESUMO

PURPOSE: To determine whether hyperpolarized helium 3 magnetic resonance (MR) imaging to measure alveolar partial pressure of oxygen (Pao2) shows sufficient test-retest repeatability and between-cohort differences to be used as a reliable technique for detection of alterations in gas exchange in asymptomatic smokers. MATERIALS AND METHODS: The protocol was approved by the local institutional review board and was HIPAA compliant. Informed consent was obtained from all subjects. Two sets of MR images were obtained 10 minutes apart in 25 subjects: 10 nonsmokers (five men, five women; mean ± standard deviation age, 50 years ± 6) and 15 smokers (seven women, eight men; mean age, 50 years ± 8). A mixed-effects model was developed to identify the regional repeatability of Pao2 measurements as an intraclass correlation coefficient. Ten smokers were matched with the 10 nonsmokers on the basis of signal-to-noise ratio (SNR). Three separate models were generated: one for nonsmokers, one for the SNR-matched smokers, and one for the five remaining smokers, who were imaged with a significantly higher SNR. RESULTS: Short-term back-to-back regional reproducibility was assessed by using intraclass correlation coefficients, which were 0.67 and 0.65 for SNR case-matched nonsmokers and smokers, respectively. Repeatability was a strong function of SNR; a 50% increase in SNR in the remaining smokers improved the intraclass correlation coefficient to 0.82. Although repeatability was not significantly different between the SNR-matched cohorts (P = .44), the smoker group showed higher spatial and temporal variability in Pao2. CONCLUSION: The short-term test-retest repeatability of hyperpolarized gas MR imaging of regional Pao2 was good. Asymptomatic smokers exhibited greater spatial and temporal variability in Pao2 than did the nonsmokers, which suggests that this parameter allows detection of small functional alterations associated with smoking.


Assuntos
Imageamento por Ressonância Magnética/métodos , Troca Gasosa Pulmonar , Fumar/fisiopatologia , Adulto , Feminino , Hélio , Humanos , Isótopos , Masculino , Pessoa de Meia-Idade , Oxigênio , Pressão Parcial , Alvéolos Pulmonares , Reprodutibilidade dos Testes , Fatores de Tempo
18.
J Appl Physiol (1985) ; 118(3): 377-85, 2015 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-25640150

RESUMO

Quantitative analysis of computed tomography (CT) is essential to the study of acute lung injury. However, quantitative CT is made difficult by poor lung aeration, which complicates the critical step of image segmentation. To overcome this obstacle, this study sought to develop and validate a semiautomated, multilandmark, registration-based scheme for lung segmentation that is effective in conditions of poor aeration. Expiratory and inspiratory CT images were obtained in rats (n = 8) with surfactant depletion of incremental severity to mimic worsening aeration. Trained operators manually delineated the images to provide a comparative landmark. Semiautomatic segmentation originated from a single, previously segmented reference image obtained at healthy baseline. Deformable registration of the target images (after surfactant depletion) was performed using the symmetric diffeomorphic transformation model with B-spline regularization. Registration used multiple landmarks (i.e., rib cage, spine, and lung parenchyma) to minimize the effect of poor aeration. Then target images were automatically segmented by applying the calculated transformation function to the reference image contour. Semiautomatically and manually segmented contours proved to be highly similar in all aeration conditions, including those characterized by more severe surfactant depletion and expiration. The Dice similarity coefficient was over 0.9 in most conditions, confirming high agreement, irrespective of poor aeration. Furthermore, CT density-based measurements of gas volume, tissue mass, and lung aeration distribution were minimally affected by the method of segmentation. Moving forward, multilandmark registration has the potential to streamline quantitative CT analysis by enabling semiautomatic image segmentation of lungs with a broad range of injury severity.


Assuntos
Lesão Pulmonar/diagnóstico por imagem , Lesão Pulmonar/patologia , Tensoativos/efeitos adversos , Animais , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Lesão Pulmonar/induzido quimicamente , Masculino , Ratos , Ratos Sprague-Dawley , Tomografia Computadorizada por Raios X/métodos
19.
Radiology ; 274(2): 585-96, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25322340

RESUMO

PURPOSE: To assess the ability of helium 3 ((3)He) magnetic resonance (MR) imaging of regional alveolar partial pressure of oxygen (Pao2) to depict smoking-induced functional alterations and to compare its efficacy to that of current diagnostic techniques. MATERIALS AND METHODS: This study was approved by the local institutional review board and was compliant with HIPAA. All subjects provided informed consent. A total of 43 subjects were separated into three groups: nonsmokers, asymptomatic smokers, and symptomatic smokers. All subjects underwent a Pao2 imaging session followed by clinically standard pulmonary function tests (PFTs), the 6-minute walk test, and St George Respiratory Questionnaire (SGRQ). The whole-lung mean and standard deviation of Pao2 were compared with metrics derived from PFTs, the 6-minute walk test, and the SGRQ. A logistic regression model was developed to identify the predictors of alterations to the lungs of asymptomatic smokers. RESULTS: The whole-lung standard deviation of Pao2 correlated with PFT metrics (forced expiratory volume in 1 second [FEV1]/forced vital capacity [FVC], Pearson r = -0.69, P < .001; percentage predicted FEV1, Pearson r = -0.67, P < .001; diffusing capacity of lung for carbon monoxide [Dlco], Pearson r = -0.45, P = .003), SGRQ score (Pearson r = 0.67, P < .001), and distance walked in 6 minutes (Pearson r = -0.47, P = .002). The standard deviation of Pao2 was significantly higher in asymptomatic smokers than in nonsmokers (change in the standard deviation of Pao2 = 7.59 mm Hg, P = .041) and lower when compared with symptomatic smokers (change in the standard deviation of Pao2 = 10.72 mm Hg, P = .001). A multivariate prediction model containing FEV1/FVC and the standard deviation of Pao2 (as significant predictors of subclinical changes in smokers) and Dlco (as a confounding variable) was formulated. This model resulted in an area under the receiver operating characteristic curve with a significant increase of 29.2% when compared with a prediction model based solely on nonimaging clinical tests. CONCLUSION: The (3)He MR imaging heterogeneity metric (standard deviation of Pao2) enabled the differentiation of all three study cohorts, which indicates that it can depict smoking-related functional alterations in asymptomatic current smokers.


Assuntos
Hélio , Imageamento por Ressonância Magnética/métodos , Oxigênio/fisiologia , Alvéolos Pulmonares/fisiopatologia , Fumar/fisiopatologia , Feminino , Humanos , Isótopos , Masculino , Pessoa de Meia-Idade , Pressão Parcial , Testes de Função Respiratória
20.
NMR Biomed ; 27(12): 1439-50, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25395184

RESUMO

The purpose of this study was to evaluate whether regional alveolar oxygen tension (P(A)O2) vertical gradients imaged with hyperpolarized (3)He can identify smoking-induced pulmonary alterations. These gradients are compared with common clinical measurements including pulmonary function tests (PFTs), the six minute walk test, and the St. George's Respiratory Questionnaire. 8 healthy non-smokers, 12 asymptomatic smokers, and 7 symptomatic subjects with chronic obstructive pulmonary disease (COPD) underwent two sets of back-to-back P(A)O2 imaging acquisitions in the supine position in two opposite directions (top to bottom and bottom to top), followed by clinically standard pulmonary tests. The whole-lung mean, standard deviation (DP(A)O2) and vertical gradients of P(A)O2 along the slices were extracted, and the results were compared with clinically derived metrics. Statistical tests were performed to analyze the differences between cohorts. The anterior-posterior vertical gradients and DP(A)O2 effectively differentiated all three cohorts (p < 0.05). The average vertical gradient P(A)O2 in healthy subjects was -1.03 ± 0.51 Torr/cm toward lower values in the posterior/dependent regions. The directional gradient was absent in smokers (0.36 ± 1.22 Torr/cm) and was in the opposite direction in COPD subjects (2.18 ± 1.54 Torr/cm). The vertical gradients correlated with smoking history (p = 0.004); body mass index (p = 0.037), PFT metrics (forced expiratory volume in 1 s, p = 0.025; residual volume/total lung capacity percent predicted, p = 0.033) and with distance walked in 6 min (p = 0.009). Regional P(A)O2 data indicate that cigarette smoke induces physiological alterations that are not being detected by the most widely used physiological tests.


Assuntos
Hélio , Imageamento por Ressonância Magnética , Oxigênio/metabolismo , Alvéolos Pulmonares/fisiologia , Decúbito Dorsal , Adulto , Idoso , Análise de Variância , Estudos de Coortes , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA