Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
JACC Heart Fail ; 12(7): 1179-1192, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38206234

RESUMO

BACKGROUND: Interventricular interactions may be responsible for the decline in ventricular performance observed in various disease states that primarily affect the contralateral ventricle. OBJECTIVES: This study sought to quantify the impact of such interactions on right ventricular (RV) size and function using clinically stable individuals with left ventricular assist devices (LVADs) as a model for assessing RV hemodynamics while LV loading conditions were acutely manipulated by changing device speed during hemodynamic optimization studies (ie, ramp tests). METHODS: The investigators recorded RV pressure-volume loops with a conductance catheter at various speeds during ramp tests in 20 clinically stable HeartMate3 recipients. RESULTS: With faster LVAD speeds and greater LV unloading, indexed RV end-diastolic volume increased (72.28 ± 15.07 mL at low speed vs 75.95 ± 16.90 at high speed; P = 0.04) whereas indexed end-systolic volumes remained neutral. This resulted in larger RV stroke volumes and shallower end-diastolic pressure-volume relationships. Concurrently, RV end-systolic pressure decreased (31.58 ± 9.75 mL at low speed vs 29.58 ± 9.41 mL at high speed; P = 0.02), but contractility, as measured by end-systolic elastance, did not change significantly. The reduction in RV end-systolic pressure was associated with a reduction in effective arterial elastance from 0.65 ± 0.43 mm Hg/mL at low speed to 0.54 ± 0.33 mm Hg/mL at high speed (P = 0.02). CONCLUSIONS: Interventricular interactions resulted in improved RV compliance, diminished afterload, and did not reduce RV contractility. These data challenge the prevailing view that interventricular interactions compromise RV function, which has important implications for the understanding of RV-LV interactions in various disease states, including post-LVAD RV dysfunction.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Volume Sistólico , Função Ventricular Direita , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Função Ventricular Direita/fisiologia , Volume Sistólico/fisiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Pressão Ventricular/fisiologia , Idoso , Adulto , Hemodinâmica/fisiologia
3.
JACC Cardiovasc Imaging ; 17(1): 79-95, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37731368

RESUMO

Tricuspid regurgitation (TR) is a highly prevalent and heterogeneous valvular disease, independently associated with excess mortality and high morbidity in all clinical contexts. TR is profoundly undertreated by surgery and is often discovered late in patients presenting with right-sided heart failure. To address the issue of undertreatment and poor clinical outcomes without intervention, numerous structural tricuspid interventional devices have been and are in development, a challenging process due to the unique anatomic and physiological characteristics of the tricuspid valve, and warranting well-designed clinical trials. The path from routine practice TR detection to appropriate TR evaluation, to conduction of clinical trials, to enriched therapeutic possibilities for improving TR access to treatment and outcomes in routine practice is complex. Therefore, this paper summarizes the key points and methods crucial to TR detection, quantitation, categorization, risk-scoring, intervention-monitoring, and outcomes evaluation, particularly of right-sided function, and to clinical trial development and conduct, for both interventional and surgical groups.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Diagnóstico por Imagem , Valor Preditivo dos Testes , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Ensaios Clínicos como Assunto
4.
N Engl J Med ; 388(20): 1833-1842, 2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-36876753

RESUMO

BACKGROUND: Severe tricuspid regurgitation is a debilitating condition that is associated with substantial morbidity and often with poor quality of life. Decreasing tricuspid regurgitation may reduce symptoms and improve clinical outcomes in patients with this disease. METHODS: We conducted a prospective randomized trial of percutaneous tricuspid transcatheter edge-to-edge repair (TEER) for severe tricuspid regurgitation. Patients with symptomatic severe tricuspid regurgitation were enrolled at 65 centers in the United States, Canada, and Europe and were randomly assigned in a 1:1 ratio to receive either TEER or medical therapy (control). The primary end point was a hierarchical composite that included death from any cause or tricuspid-valve surgery; hospitalization for heart failure; and an improvement in quality of life as measured with the Kansas City Cardiomyopathy Questionnaire (KCCQ), with an improvement defined as an increase of at least 15 points in the KCCQ score (range, 0 to 100, with higher scores indicating better quality of life) at the 1-year follow-up. The severity of tricuspid regurgitation and safety were also assessed. RESULTS: A total of 350 patients were enrolled; 175 were assigned to each group. The mean age of the patients was 78 years, and 54.9% were women. The results for the primary end point favored the TEER group (win ratio, 1.48; 95% confidence interval, 1.06 to 2.13; P = 0.02). The incidence of death or tricuspid-valve surgery and the rate of hospitalization for heart failure did not appear to differ between the groups. The KCCQ quality-of-life score changed by a mean (±SD) of 12.3±1.8 points in the TEER group, as compared with 0.6±1.8 points in the control group (P<0.001). At 30 days, 87.0% of the patients in the TEER group and 4.8% of those in the control group had tricuspid regurgitation of no greater than moderate severity (P<0.001). TEER was found to be safe; 98.3% of the patients who underwent the procedure were free from major adverse events at 30 days. CONCLUSIONS: Tricuspid TEER was safe for patients with severe tricuspid regurgitation, reduced the severity of tricuspid regurgitation, and was associated with an improvement in quality of life. (Funded by Abbott; TRILUMINATE Pivotal ClinicalTrials.gov number, NCT03904147.).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Feminino , Humanos , Masculino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Insuficiência da Valva Tricúspide/cirurgia
5.
Catheter Cardiovasc Interv ; 99(5): 1668-1678, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35066989

RESUMO

OBJECTIVE: The objective of this study was to evaluate the incidence of and risk factors associated with cardiogenic shock (CS) following surgery versus transcatheter tricuspid valve intervention (TTVI) for tricuspid regurgitation (TR). BACKGROUND: Surgical therapy for TR is associated with high rates of CS. Postprocedural shock has not been studied following TTVI. METHODS: We performed a single-center retrospective analysis of isolated tricuspid valve (TV) surgery or TTVI for TR. The primary outcome was postprocedural class D or E CS according to Society for Cardiovascular Angiography and Interventions (SCAI) CS classification scheme, and secondary outcome was in-hospital mortality. Multivariable logistic regression modeling was performed for primary and secondary outcomes. Support vector machine analysis was performed for sensitivity analysis. RESULTS: From 2008 to 2020, a total of 122 patients underwent isolated TV surgery (n = 58, 14 TV repair, and 44 TV replacement) or TTVI (n = 64, 36 TV repair, and 28 TV replacement). Surgical patients were significantly younger than TTVI patients (67.5 vs. 80 years, p < 0.0001). Multivariable modeling revealed an association between the primary outcome and surgery (odds ratio [OR]: 8.75, 95% confidence interval [CI]: 2.83, 27.03, p = 0.0002), as well as baseline central venous pressure (CVP, OR: 1.12, 95% CI: 1.02, 1.22, p = 0.016). Additionally, class DE CS was independently associated with in-hospital mortality (OR: 5.21, 1.35, 20.09, p = 0.016). CVP and surgery were found to have highest importance indices in support vector machine analysis. CONCLUSION: In patients undergoing TV intervention for TR, surgery versus TTVI and elevated CVP are associated with advanced postprocedural CS. Patients developing advanced CS are at increased risk of in-hospital mortality.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Incidência , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/terapia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/cirurgia
6.
Echocardiography ; 38(9): 1612-1617, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34505312

RESUMO

AIMS: Clinical guidelines recommend that the exercise protocol of a stress echocardiogram is selected to induce volitional exhaustion after a target duration of at least 8 minutes. While the Bruce protocol is very commonly used for clinical stress tests, it is known to be "steep", and many patients therefore fail to reach 8 minutes. We studied predictors of failure and developed a method for identifying patients not suitable for Bruce protocol which was accurate and yet simple enough to be used as a point-of-care decision support tool. METHODS AND RESULTS: We studied data out-patients undergoing Bruce protocol stress echocardiograms (n = 11 086) and analyzed predictors of inappropriate early termination (defined as test duration < 8 min as per current practice guidelines) using logistic regression. A prediction model was constructed as follows: .5 points were given for each of hypertension, diabetes, smoking, and E/e' > 7.9 in the resting echocardiogram; .1 point was added for each 1-unit increment in body mass index; 1 point was added for patient age by decade; 2.0 points were subtracted for male sex (p for all < 0.001). In tests on held-out validation data, the model was well calibrated (in plots of predicted vs actual risk) and discriminated failure versus non-failure well (C-statistic .86 for a score of 6.0 points; p < 0.001). CONCLUSION: These data may help to standardize protocol selection in stress echocardiography, by identifying patients pre-hoc where Bruce protocol will be inappropriately steep.


Assuntos
Ecocardiografia sob Estresse , Teste de Esforço , Índice de Massa Corporal , Exercício Físico , Humanos , Masculino
7.
JACC Case Rep ; 3(4): 645-649, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34317595

RESUMO

A 66-year-old man with refractory multiple myeloma presented with acute severe aortic insufficiency leading to cardiogenic shock and multiorgan failure. After comprehensive heart team evaluation, he underwent successful JenaValve transcatheter aortic valve (JenaValve Technology, Inc., Irvine, California) implantation resulting in resolution of his aortic insufficiency and improvement in his clinical status. (Level of Difficulty: Advanced.).

8.
JACC Cardiovasc Imaging ; 14(7): 1299-1305, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33744134

RESUMO

OBJECTIVES: The purpose of this study was to introduce a novel clinically relevant nomenclature system for the TV and determine the relative incidence of each morphological type. BACKGROUND: With the rapid development of transcatheter tricuspid valve (TV) repair techniques, there is a growing recognition of the variability in leaflet morphology and a need for a unified nomenclature, which could aid in procedural planning and execution. METHODS: Patients from 4 medical centers (2 in Europe, 2 in the United States) referred for transesophageal echocardiography (TEE) to assess native TV function, were retrospectively analyzed for leaflet morphology with the use of a novel classification scheme. Four morphological types were identified: type I, 3 leaflets; type II, 2 leaflets; type IIIA, 4 leaflets with 2 anterior; type IIIB, 4 leaflets with 2 posterior; type IIIC, 4 leaflets with 2 septal; and type IV, >4 leaflets. RESULTS: A total of 579 patients were analyzed: mean age 78.1 ± 8.0 years, 50.4% female, 70.9% in atrial fibrillation, and 32.2% with previous left heart surgery or transcatheter intervention. Tricuspid regurgitation was moderate or less in 9.4%, severe in 40.5%, massive in 32.3%, and torrential in 17.7%. The etiology of tricuspid regurgitation was primary in 9.4%, mixed in 10.8%, and secondary in all of the other patients (18.6% atriogenic/isolated). The incidence of type I morphology was 312 of 579 (53.9%), type II was 26 of 579 (4.5%), type IIIA was 15 of 579 (2.6%), type IIIB was 186 of 579 (32.1%), type IIIC was 22 of 579 (3.8%), and type IV was 14 of 579 (2.4%). CONCLUSIONS: A novel TV leaflet nomenclature classification scheme can be used to identify 4 types of TV morphologies with the use of TEE imaging. From this multinational retrospective study, the TV has 3 well defined leaflets in only ∼54% of patients and 4 functional leaflets in ∼39% of patients, with type IIIB (2 posterior leaflets) being the most common of the latter. The utility of this classification scheme deserves further study.


Assuntos
Ecocardiografia , Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Europa (Continente) , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
9.
Eur J Heart Fail ; 23(2): 250-258, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32729170

RESUMO

AIMS: Advances in diagnostic imaging have increased the recognition of coexisting transthyretin cardiac amyloidosis (ATTR-CA) and severe aortic stenosis (AS), with a reported prevalence between 8-16%. In this prospective study, we aimed to evaluate the implications of ATTR-CA on outcomes after transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: At two academic centres, we screened patients with severe AS undergoing TAVR for ATTR-CA. Using Kaplan-Meier analysis, we compared survival free from death and a combined endpoint of death and first heart failure hospitalization between patients with and without ATTR-CA. Cox proportional-hazards models were used to determine the association of ATTR-CA with these endpoints. The rate of heart failure hospitalization was compared amongst those with and without ATTR-CA. Overall, 204 patients (83 years, 65% male, Society of Thoracic Surgeons score 6.6%, 72% New York Heart Association class III/IV) were included, 27 (13%) with ATTR-CA. Over a median follow-up of 2.04 years, there was no difference in mortality (log rank, P = 0.99) or the combined endpoint (log rank, P = 0.79) between patients with and without ATTR-CA. In Cox proportional-hazards models, the presence of ATTR-CA was not associated with death. However, patients with ATTR-CA had increased rates of heart failure hospitalization at 1 year (0.372 vs. 0.114 events/person-year, P < 0.004) and 3 years (0.199 vs. 0.111 events/person-year, P = 0.087) following TAVR. CONCLUSION: In moderate-risk patients with severe AS undergoing TAVR, there was a 13% prevalence of ATTR-CA, which did not affect mortality. The observed increase in heart failure hospitalization following TAVR in those with ATTR-CA suggests the consequences of the underlying infiltrative myopathy.


Assuntos
Amiloidose , Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Pré-Albumina , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
11.
Eur Heart J Case Rep ; 2(4): yty146, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31020221

RESUMO

BACKGROUND: The MitraClip system has been used extensively in high-risk patients with severe degenerative mitral regurgitation (MR). Recent reports have demonstrated the feasibility of using the MitraClip device to treat systolic anterior motion (SAM) of the mitral valve in obstructive hypertrophic cardiomyopathy (HOCM). CASE SUMMARY: We report the case of a 76-year-old lady who had both symptomatic severe degenerative MR and HOCM that were refractory to medical therapy. Both pathologies were treated successfully using the MitraClip system. DISCUSSION: In patients who are deemed to be at high risk for open surgery, our case demonstrated the feasibility of a percutaneous avenue, the MitraClip system, to treat not just degenerative MR, but also SAM from HOCM in a single procedure.

12.
Eur Heart J ; 38(38): 2879-2887, 2017 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-29019612

RESUMO

AIMS: Transthyretin cardiac amyloidosis (ATTR-CA) has been reported in patients with aortic stenosis (AS) but its prevalence and phenotype are not known. We examine elderly patients with severe symptomatic AS undergoing transcatheter aortic valve replacement (TAVR) and determine the prevalence and phenotype of ATTR-CA non-invasively. METHODS AND RESULTS: We performed technetium-99m pyrophosphate (99mTc-PYP) cardiac scintigraphy prospectively on patients who underwent TAVR, to screen for ATTR-CA. Transthoracic echocardiography and speckle-strain imaging were performed. We assessed the association of several parameters with ATTR-CA using multivariable logistic regression and constructed receiver operating curves to evaluate the best predictors of ATTR-CA. Among 151 patients (mean age 84 ± 6 years, 68% men), 16% (n = 24) screened positive for ATTR-CA with 99mTc-PYP scintigraphy. Compared with patients without ATTR-CA, ATTR-CA patients had a thicker interventricular septum (1.3 vs. 1.1 cm, P = 0.007), higher left ventricular (LV) mass index (130 vs. 98 g/m2, P = 0.002), and lower stroke volume index (30 vs. 36 mL/m2, P = 0.009). ATTR-CA patients had advanced diastolic dysfunction with higher E/A ratio (2.3 vs. 0.9, P = 0.001) and lower deceleration time (176 vs. 257 ms, P < 0.0001); impairment in systolic function with lower ejection fraction (48% vs. 56%, P = 0.011), myocardial contraction fraction (26 vs. 41, P < 0.0001), and average of lateral and septal mitral annular tissue Doppler S' (4.0 vs. 6.6 cm/s, P < 0.0001). While ATTR-CA patients had more impaired global longitudinal strain (-12 vs. -16%, P = 0.007), relative apical longitudinal strain was the same regardless of ATTR-CA diagnosis (0.98 vs. 0.98, P = 0.991). Average S' best predicted ATTR-CA in multivariable logistic regression (odds ratio 16.67 per 1 cm/s decrease with AUC 0.96, 95% confidence interval 0.90-0.99, P = 0.002) with a value ≤6 conferring 100% sensitivity for predicting a positive 99mTc-PYP amyloid scan. CONCLUSIONS: Transthyretin cardiac amyloidosis is prevalent in 16% of patients with severe calcific AS undergoing TAVR and is associated with a severe AS phenotype of low-flow low-gradient with mildly reduced ejection fraction. Average tissue Doppler mitral annular S' of < 6 cm/s may be a sensitive measure that should prompt a confirmatory 99mTc-PYP scan and subsequent testing for ATTR-CA. Prospective assessment of outcomes after TAVR is needed in patients with and without ATTR-CA.


Assuntos
Neuropatias Amiloides Familiares/complicações , Estenose da Valva Aórtica/complicações , Cardiomiopatias/complicações , Calcificação Vascular/complicações , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Fenótipo , Estudos Prospectivos , Cintilografia , Compostos Radiofarmacêuticos , Volume Sistólico/fisiologia , Pirofosfato de Tecnécio Tc 99m , Substituição da Valva Aórtica Transcateter , Calcificação Vascular/cirurgia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
13.
J Cardiovasc Comput Tomogr ; 11(4): 302-308, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28457950

RESUMO

BACKGROUND: The threshold for the optimal computed tomography (CT) number in Hounsfield Units (HU) to quantify aortic valvular calcium on contrast-enhanced scans has not been standardized. Our aim was to find the most accurate threshold to predict paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR). METHODS: 104 patients who underwent TAVR with the CoreValve prosthesis were studied retrospectively. Luminal attenuation (LA) in HU was measured at the level of the aortic annulus. Calcium volume score for the aortic valvular complex was measured using 6 threshold cutoffs (650 HU, 850 HU, LA × 1.25, LA × 1.5, LA+50, LA+100). Receiver-operating characteristic (ROC) analysis was performed to assess the predictive value for > mild PVR (n = 16). Multivariable analysis was performed to determine the accuracy to predict > mild PVR after adjustment for depth and perimeter oversizing. RESULTS: ROC analysis showed lower area under the curve (AUC) values for fixed threshold cutoffs (650 or 850 HU) compared to thresholds relative to LA. The LA+100 threshold had the highest AUC (0.81), and AUC was higher than all studied protocols, other than the LA x 1.25 and LA + 50 protocols, where the difference approached statistical significance (p = 0.05, and 0.068, respectively). Multivariable analysis showed calcium volume determined by the LAx1.25, LAx1.5, LA+50, and LA+ 100 HU protocols to independently predict PVR. CONCLUSIONS: Calcium volume scoring thresholds which are relative to LA are more predictive of PVR post-TAVR than those which use fixed cutoffs. A threshold of LA+100 HU had the highest predictive value.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Área Sob a Curva , Calcinose/fisiopatologia , Calcinose/cirurgia , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
14.
Ann Thorac Surg ; 102(2): e83-5, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27449464

RESUMO

With the advent of percutaneous valve interventions, the landscape for management of high-risk valve replacement and repair has changed dramatically. Transcatheter valve repair/replacement techniques can be used in conjunction with open surgery to facilitate a hybrid approach in patients with multivalve disease. We present a case of staged hybrid valve repair followed by surgical replacement for a high-risk patient with mitral regurgitation and aortic regurgitation. This case illustrates the effectiveness of the staged hybrid approach for high-risk patients with incomplete transcatheter options. We expect these techniques to play an increasingly larger role in the treatment algorithm for high-risk multivalve disease.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Procedimentos Endovasculares/métodos , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Falha de Prótese , Reoperação , Medição de Risco , Índice de Gravidade de Doença , Instrumentos Cirúrgicos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Ultrassonografia Doppler em Cores
15.
JACC Cardiovasc Imaging ; 8(8): 960-79, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26271092

RESUMO

An increased use of bioprosthetic heart valves has stimulated an interest in possible transcatheter options for bioprosthetic valve failure given the high operative risk. The encouraging results of transcatheter aortic valve implantation in high-risk surgical candidates with native disease have led to the development of the transcatheter valve-in-valve (VIV) procedures for failed bioprostheses. VIV procedures are unique in many ways, and there is an increased need for multimodality imaging in a team-based approach. The echocardiographic approach to VIV procedures has not previously been described. In this review, we summarize key echocardiographic requirements for optimal patient selection, procedural guidance, and immediate post-procedural assessment for VIV procedures.


Assuntos
Bioprótese , Ecocardiografia , Implante de Prótese de Valva Cardíaca/métodos , Valva Aórtica , Cateterismo , Humanos , Valva Mitral , Valva Pulmonar , Reoperação , Falha de Tratamento , Valva Tricúspide
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA