Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Am Coll Cardiol ; 82(19): 1828-1838, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37914512

RESUMO

BACKGROUND: GadaCAD2 was 1 of 2 international, multicenter, prospective, Phase 3 clinical trials that led to U.S. Food and Drug Administration approval of gadobutrol to assess myocardial perfusion and late gadolinium enhancement (LGE) in adults with known or suspected coronary artery disease (CAD). OBJECTIVES: A prespecified secondary objective was to determine if stress perfusion cardiovascular magnetic resonance (CMR) was noninferior to single-photon emission computed tomography (SPECT) for detecting significant CAD and for excluding significant CAD. METHODS: Participants with known or suspected CAD underwent a research rest and stress perfusion CMR that was compared with a gated SPECT performed using standard clinical protocols. For CMR, adenosine or regadenoson served as vasodilators. The total dose of gadobutrol was 0.1 mmol/kg body weight. The standard of reference was a 70% stenosis defined by quantitative coronary angiography (QCA). A negative coronary computed tomography angiography could exclude CAD. Analysis was per patient. CMR, SPECT, and QCA were evaluated by independent central core lab readers blinded to clinical information. RESULTS: Participants were predominantly male (61.4% male; mean age 58.9 ± 10.2 years) and were recruited from the United States (75.0%), Australia (14.7%), Singapore (5.7%), and Canada (4.6%). The prevalence of significant CAD was 24.5% (n = 72 of 294). Stress perfusion CMR was statistically superior to gated SPECT for specificity (P = 0.002), area under the receiver operating characteristic curve (P < 0.001), accuracy (P = 0.003), positive predictive value (P < 0.001), and negative predictive value (P = 0.041). The sensitivity of CMR for a 70% QCA stenosis was noninferior and nonsuperior to gated SPECT. CONCLUSIONS: Vasodilator stress perfusion CMR, as performed with gadobutrol 0.1 mmol/kg body weight, had superior diagnostic accuracy for diagnosis and exclusion of significant CAD vs gated SPECT.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Peso Corporal , Constrição Patológica , Meios de Contraste , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Gadolínio , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Vasodilatadores
2.
Circulation ; 145(19): 1443-1455, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35533220

RESUMO

BACKGROUND: TEXTMEDS (Text Messages to Improve Medication Adherence and Secondary Prevention After Acute Coronary Syndrome) examined the effects of text message-delivered cardiac education and support on medication adherence after an acute coronary syndrome. METHODS: TEXTMEDS was a single-blind, multicenter, randomized controlled trial of patients after acute coronary syndrome. The control group received usual care (secondary prevention as determined by the treating clinician); the intervention group also received multiple motivational and supportive weekly text messages on medications and healthy lifestyle with the opportunity for 2-way communication (text or telephone). The primary end point of self-reported medication adherence was the percentage of patients who were adherent, defined as >80% adherence to each of up to 5 indicated cardioprotective medications, at both 6 and 12 months. RESULTS: A total of 1424 patients (mean age, 58 years [SD, 11]; 79% male) were randomized from 18 Australian public teaching hospitals. There was no significant difference in the primary end point of self-reported medication adherence between the intervention and control groups (relative risk, 0.93 [95% CI, 0.84-1.03]; P=0.15). There was no difference between intervention and control groups at 12 months in adherence to individual medications (aspirin, 96% vs 96%; ß-blocker, 84% vs 84%; angiotensin-converting enzyme inhibitor/angiotensin receptor blocker, 77% vs 80%; statin, 95% vs 95%; second antiplatelet, 84% vs 84% [all P>0.05]), systolic blood pressure (130 vs 129 mm Hg; P=0.26), low-density lipoprotein cholesterol (2.0 vs 1.9 mmol/L; P=0.34), smoking (P=0.59), or exercising regularly (71% vs 68%; P=0.52). There were small differences in lifestyle risk factors in favor of intervention on body mass index <25 kg/m2 (21% vs 18%; P=0.01), eating ≥5 servings per day of vegetables (9% vs 5%; P=0.03), and eating ≥2 servings per day of fruit (44% vs 39%; P=0.01). CONCLUSIONS: A text message-based program had no effect on medical adherence but small effects on lifestyle risk factors. REGISTRATION: URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=364448; Unique identifier: ANZCTR ACTRN12613000793718.


Assuntos
Síndrome Coronariana Aguda , Envio de Mensagens de Texto , Síndrome Coronariana Aguda/tratamento farmacológico , Síndrome Coronariana Aguda/prevenção & controle , Austrália , Feminino , Humanos , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Prevenção Secundária , Método Simples-Cego
3.
Tex Heart Inst J ; 49(2)2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35244722

RESUMO

Computed tomographic coronary artery calcium scanning enables cardiovascular risk stratification; however, exposing patients to high radiation levels is an ongoing concern. New-generation computed tomographic systems use lower radiation doses than older systems do. To quantify comparative doses of radiation exposure, we prospectively acquired images from 220 patients with use of a 64-slice GE LightSpeed VCT scanner (control group, n=110) and a 256-slice GE Revolution scanner (study group, n=110). The groups were matched for age, sex, and body mass index; statistical analysis included t tests and linear regression. The mean dose-length product was 21% lower in the study group than in the control group (60.2 ± 27 vs 75.9 ± 22.6 mGy·cm; P <0.001) and also in each body mass index subgroup. Similarly, the mean effective radiation dose was 21% lower in the study group (0.84 ± 0.38 vs 1.06 ± 0.32 mSv) and lower in each weight subgroup. After adjustment for sex, women in the study group had a lower dose-length product (50.4 ± 23.4 vs 64.7 ± 27.6 mGy·cm) than men did and received a lower effective dose (0.7 ± 0.32 vs 0.9 ± 0.38 mSv) (P=0.009). As body mass index and waist circumference increased, so did doses for both scanners. Our study group was exposed to radiation doses lower than the previously determined standard of 1 mSv, even after adjustment for body mass index and waist circumference. In 256-slice scanning for coronary artery calcium, radiation doses are now similar to those in lung cancer screening and mammography.


Assuntos
Doença da Artéria Coronariana , Neoplasias Pulmonares , Cálcio , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Doses de Radiação
4.
J Cardiovasc Magn Reson ; 23(1): 44, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33794918

RESUMO

The Society for Cardiovascular Magnetic Resonance (SCMR) is an international society focused on the research, education, and clinical application of cardiovascular magnetic resonance (CMR). The SCMR web site ( https://www.scmr.org ) hosts a case series designed to present case reports demonstrating the unique attributes of CMR in the diagnosis or management of cardiovascular disease. Each clinical presentation is followed by a brief discussion of the disease and unique role of CMR in disease diagnosis or management guidance. By nature, some of these are somewhat esoteric, but all are instructive. In this publication, we provide a digital archive of the 2019 Case of the Week series as a means of further enhancing the education of those interested in CMR and as a means of more readily identifying these cases using a PubMed or similar search engine.


Assuntos
Síndrome de Churg-Strauss/diagnóstico por imagem , Imageamento por Ressonância Magnética , Trombose/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Antineoplásicos/efeitos adversos , Cardiotoxicidade , Síndrome de Churg-Strauss/fisiopatologia , Síndrome de Churg-Strauss/terapia , Diagnóstico Diferencial , Feminino , Neoplasias Cardíacas/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Trombose/fisiopatologia , Trombose/terapia , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda/efeitos dos fármacos , Adulto Jovem
5.
J Nucl Med Technol ; 49(1): 65-69, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33219160

RESUMO

We intended to assess the ability of current-generation 256-slice coronary CT angiography (CCTA) to measure left atrial volume (LAV), comparing patients with a high heart rate (HiHR) of at least 70 bpm and patients with heart rate variability such as atrial fibrillation (AFib). Methods: Using the prospective Converge Registry of patients undergoing 256-detector CCTA on a Revolution scanner, we enrolled 121 HiHR patients (74 men; mean age, 62.7 ± 12.5 y) and 102 AFib patients (72 men; mean age, 60.5 ± 11.0 y) after obtaining informed consent. Quantitative data analysis of LAV was performed using automated methods, and end-systolic phases were chosen for measurements from CCTA. A Student t test, Wilcoxon rank-sum test, or χ2 test assessed baseline parameters. Univariate and multivariate linear regression analysis was used to assess LAV and LAV index (LAVI) while adjusting potentially confounding variables. Results: Mean LAV was significantly higher in AFib subjects (148.6 ± 57.2 mL) than in HiHR subjects (102.1 ± 36.5 mL) (P < 0.0001). Similarly, mean LAVI was significantly higher in AFib subjects (72.4 ± 28.1 mL/m2) than in HiHR subjects (51.5 ± 19.0 mL/m2) (P < 0.0001). After adjusting for age, body mass index, sex, diabetes, hypertension, hyperlipidemia, and smoking, subjects with AFib had, on average, LAV measures higher by 41.2 ± 6.7 mL and LAVI values higher by 23.1 ± 3.4 mL/m2 (P < 0.0001). Conclusion: Misalignment and motion artifacts in CCTA images affect diagnostic CT performance, especially in patients with elevated heart rates or profound arrhythmia. However, the new-generation Revolution CCTA provides detailed information on left-atrium-complex morphology and function, in addition to coronary anatomy, in HiHR and AFib patients without additional radiation, scanning, or contrast requirements.


Assuntos
Angiografia por Tomografia Computadorizada , Átrios do Coração , Idoso , Átrios do Coração/diagnóstico por imagem , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Tecnologia
6.
J Nucl Med Technol ; 48(1): 58-62, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32144159

RESUMO

Coronary artery disease is the leading cause of morbidity and mortality. Tools have been developed to accurately diagnose and evaluate coronary artery disease. Coronary CT angiography (CCTA) provides detailed imaging to deliver precise analysis and prognostic information. We sought to compare the radiation dose from a 256-detector-row CT scanner with that from a 64-detector-row CT scanner across a similar profile of patients. Methods: Consecutive patients were screened for the Converge Registry study and, after consenting to be included, were enrolled in accordance with an Institutional Review Board-approved protocol. A control group who underwent 64-row CCTA were matched by age, sex, and body mass index (BMI) with a group who underwent 256-row CCTA. Results: We compared 110 patients in each group. We found that mean dose-length product (DLP) was significantly lower in the 256-row group than in the 64-row group (P < 0.05). The radiation dose was reduced by 32% with use of the 256-row scanner for BMIs of 18.5-24.9 (DLP, 111.2 vs. 76.1 mGy-cm [1.56 vs. 1.07 mSv]; P < 0.05). For each BMI subgroup, there was a significant decrease in dose. Regression analysis found that with increasing BMIs, DLP significantly increased for both scanners. Conclusion: The 256-row scanner provided CCTA scans at significantly lower radiation doses than the 64-row scanner in different BMI groups, with all other variables accounted for. Lower radiation exposure along with lower contrast requirements can provide images with high diagnostic accuracy and less risk to the patient.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Meios de Contraste/química , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Índice de Massa Corporal , Feminino , Coração , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Sistema de Registros , Medição de Risco/legislação & jurisprudência , Fatores de Risco
8.
J Med Radiat Sci ; 67(1): 25-33, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31693313

RESUMO

INTRODUCTION: Coronary CT Angiography (CCTA) is a rapidly increasing technique for coronary imaging; however, it exposes patients to ionising radiation. We examined the impact of dose reduction techniques using ECG-triggering, kVp/mAs reduction and high-pitch modes on radiation exposure in a large Australian tertiary CCTA service. METHODS: Data on acquisition modes and dose exposure were prospectively collected on all CCTA scans from November 2009 to March 2014 at an Australian tertiary care centre. A dose reduction algorithm was developed using published techniques and implemented with education of medical staff, radiographers and referrers. Associations of CCTA acquisition to radiation over time were analysed with multivariate regression. Specificity in positive CCTA was assessed by correlation with invasive coronary angiography. RESULTS: 3333 CCTAs were analysed. Mean radiation dose decreased from 8.4 mSv to 5.3, 4.4, 3.7, 2.9 and 2.8 mSv (P < 0.001) per year. Patient characteristics were unchanged. Dose reduction strategies using ECG-triggering, kVp/mAs reduction accounted for 91% of the decrease. High-pitch scanning reduced dose by an additional 9%. Lower dose was independently related to lower kVp, heart rate, tube current modulation, BMI, prospective triggering and high-pitch mode (P < 0.01). CCTA specificity remained unchanged despite dose reduction. CONCLUSION: Implementation of evidence-based CCTA dose reduction algorithm and staff education programme resulted in a 67% reduction in radiation exposure, while maintaining diagnostic specificity. This approach is widely applicable to clinical practice for the performance of CCTA.


Assuntos
Angiografia Coronária/métodos , Doses de Radiação , Exposição à Radiação , Tomografia Computadorizada por Raios X/métodos , Austrália , Angiografia Coronária/normas , Medicina Baseada em Evidências/métodos , Medicina Baseada em Evidências/normas , Feminino , Humanos , Masculino , Guias de Prática Clínica como Assunto , Centros de Atenção Terciária/normas , Tomografia Computadorizada por Raios X/normas
9.
J Nucl Med Technol ; 2019 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-31604891

RESUMO

Intro: Coronary artery disease is the leading cause for morbidity and mortality. Tools have been developed to accurately diagnose and evaluate coronary artery disease. Coronary computed tomographic angiography (CCTA) scans provide detailed imaging along with analysis to in order to deliver precise analysis and prognostic information. We sought to evaluate the radiation doses of the 256 detector CT scanner to a 64 slice scanner across a similar profile of patients. Methods: Consecutive patients were screened, enrolled, and consented for the Converge Registry study, in accordance with the Institutional Review Board (IRB) approved protocol. 110 patients underwent CCTA using the GE Revolution 256 detector CT scanner. We matched patients by age, gender and body mass index (BMI) who underwent 64 slice CT scanning. Results: We compared 110 patients in each group. We found that mean dose length product (DLP, presented also in the tables below in millisieverts (mSv)) was significantly lower in the Revolution 256 detector group compared to the 64 slice control group (p<0.05). The radiation dose was reduced 32% with use of Revolution 256 detector scanner for BMI between 18.5 and 24.9 (DLP = 111.2 vs 76.1; 1.56 vs 1.07 mSv; p<0.05). For each BMI subgroup, there was a significant decrease in dose. Regression analysis found that with the increase in BMI both scanners experienced a significant increase in DLP. Conclusion: We are able to demonstrate that the 256 slice CT scanner is able to provide CCTA scans at significantly lower radiation doses compared to the 64 row scanner at different BMI groups, with all other variables accounted for. Lower radiation exposures along with lower contrast requirements can provide quality imaging with high diagnostic accuracy and less risk to the patient.

10.
Acad Radiol ; 26(11): 1443-1449, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30683612

RESUMO

RATIONALE AND OBJECTIVES: Novel technology in coronary computed tomographic angiography allows assessment of coronary artery disease with high image quality (IQ). There are currently two wide detector "whole heart" coverage scanners available, which avoid misregistration artifacts. However, there are no data directly comparing IQ between the two scanners. The aim of the current study is to investigate if IQ is different between the most scanners of GE and Toshiba broad detector scanners. MATERIALS AND METHODS: Prospective, observational, multicenter international cohort study comparing 236 consecutive patients who underwent coronary computed tomographic angiography using whole-heart scanners; 126 patients on scanner S1 ( Aquilion ONE Vision, Toshiba), and 110 patients on scanner S2 (Revolution CT, GE Healthcare). Hounsfield units were measured using regions of interest in the descending aorta at 6 points (cranial slice, level of the visualized first, second, third, and fourth spines, and the caudal slice). We also compared the coverage length (z-axis) of the full width field of view between a single rotation of the two scanners. RESULTS: Evaluating mean CT attenuation values Hounsfield units through the scan range, are progressively reduced across the descending aorta in the S1 group, resulting in the larger difference of contrast brightness between the cranial and caudal slices compared to the S2 group (absolute difference: S2 13.0 ± 4.4 vs S1 141.9 ± 16.4, p < 0.0001; Percent difference: 19.3 ± 2.1 vs -3.4 ± 1.2, <0.0001). The standard deviation (SD) is similar at the cranial slice between the two scanners, however, the S1 group demonstrated higher SD-differential from cranial to caudal than S2 group. Median radiation exposure was significantly lower for the S2 scanner 1.50 ± 0.75 mSv vs the S1 system 1.9 mSv (IQR 1.7-2.7 mSv) (p = 0.01). Z-axis coverage was larger for the S2 scanner 152.5 mm (244 slices × 0.625 mm/slice) than 133 mm for S1 (266 slices × 0.5 mm/slice). CONCLUSION: Although both "volume" scanners cover the whole heart z-axis with one beat, scans using the S1 scanner have a larger variability in attenuation values throughout the scan range, resulting in 20% increase in nonuniformity from cranial to caudal slice. Additionally, SD variation across the field of view, a metric of noise, is larger when using the S1 scanner vs the S2 scanner. These results indicate that the GE Revolution CT has more uniform contrast enhancement and more coverage, lower radiation and lower image noise compared to the Toshiba Aquilion ONE Vision system.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Exposição à Radiação/prevenção & controle , Sistema de Registros , Tomógrafos Computadorizados , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação
11.
BMJ Open ; 8(1): e019463, 2018 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-29374674

RESUMO

BACKGROUND: Identifying simple, low-cost and scalable means of supporting lifestyle change and medication adherence for patients following a cardiovascular (CV) event is important. OBJECTIVE: The TEXTMEDS (TEXT messages to improve MEDication adherence and Secondary prevention) study aims to investigate whether a cardiac education and support programme sent via mobile phone text message improves medication adherence and risk factor levels in patients following an acute coronary syndrome (ACS). STUDY DESIGN: A single-blind, multicentre, randomised clinical trial of 1400 patients after an ACS with 12 months follow-up. The intervention group will receive multiple weekly text messages that provide information, motivation, support to adhere to medications, quit smoking (if relevant) and recommendations for healthy diet and exercise. The primary endpoint is the percentage of patients who are adherent to cardioprotective medications and the key secondary outcomes are mean systolic blood pressure (BP) and low-density lipoprotein cholesterol. Secondary outcomes will also include total cholesterol, mean diastolic BP, the percentage of participants who are adherent to each cardioprotective medication class, the percentage of participants who achieve target levels of CV risk factors, major vascular events, hospital readmissions and all-cause mortality. The study will be augmented by formal economic and process evaluations to assess acceptability, utility and cost-effectiveness. SUMMARY: The study will provide multicentre randomised trial evidence of the effects of a text message-based programme on cardioprotective medication adherence and levels of CV risk factors. ETHICS AND DISSEMINATION: Primary ethics approval was received from Western Sydney Local Health District Human Research Ethics Committee (HREC2012/12/4.1 (3648) AU RED HREC/13/WMEAD/15). Results will be disseminated via peer-reviewed publications and presentations at international conferences. TRIAL REGISTRATION NUMBER: ACTRN12613000793718; Pre-results.


Assuntos
Síndrome Coronariana Aguda/tratamento farmacológico , Promoção da Saúde/métodos , Adesão à Medicação , Educação de Pacientes como Assunto/métodos , Prevenção Secundária/métodos , Telemedicina/métodos , Envio de Mensagens de Texto , Pressão Sanguínea , Telefone Celular , LDL-Colesterol/sangue , Dieta , Exercício Físico , Feminino , Humanos , Estilo de Vida , Masculino , Motivação , Readmissão do Paciente , Sistemas de Alerta , Projetos de Pesquisa , Fatores de Risco , Método Simples-Cego
12.
J Med Imaging Radiat Oncol ; 62(1): 64-71, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28762641

RESUMO

INTRODUCTION: The purpose of this study was to obtain a range of normal measurements of the adult thoracic aorta and main pulmonary artery using cardiac MRI, and to assess agreement between measurements made on ECG-gated two-dimensional (2D) breath held steady-state-free precession (SSFP), and three-dimensional (3D) breath held SSFP image acquisitions. METHODS: Forty-nine normal volunteers underwent cardiac MRI using a 1.5T system. Two independent examiners measured the ascending aorta, aortic arch, descending thoracic aorta and main pulmonary artery in pre-defined locations. RESULTS: Overall, inter-observer agreement for all measurements was excellent. Close agreement was observed in aortic diameters obtained from the 2D and 3D SSFP methods in six of the nine aortic measurement sites. There was a tendency for the 3D measurements to be smaller than the 2D measurements but this was only significant at two sites, the aortic annulus, and the ascending aorta. There was a significance difference in aortic measurements between the left carotid artery (LC) and the left subclavian artery (LSC). CONCLUSION: Normal values for transverse diameters of the thoracic aorta and main pulmonary artery were established using 2D and 3D non-contrast MR sequences in healthy adults. Overall both inter-observer agreement, and agreement between 2D and 3D techniques was good. Mean diameter differences demonstrated at the aortic annulus, ascending aorta and aortic arch between LC and LSC although significant were less than one millimetre and unlikely to be important in clinical practice.


Assuntos
Aorta Torácica/anatomia & histologia , Aorta Torácica/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Artéria Pulmonar/anatomia & histologia , Artéria Pulmonar/diagnóstico por imagem , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência
13.
Heart ; 104(2): 103-110, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28822982

RESUMO

This review summaries the utility, application and data supporting use of cardiac magnetic resonance imaging (CMR) to evaluate and quantitate aortic regurgitation. We systematically searched Medline and PubMed for original research articles published since 2000 that provided data on the quantitation of aortic regurgitation by CMR and identified 11 articles for review. Direct aortic measurements using phase contrast allow quantitation of volumetric flow across the aortic valve and are highly reproducible and accurate compared with echocardiography. However, this technique requires diligence in prescribing the correct imaging planes in the aorta. Volumetric analytic techniques using differences in ventricular volumes are also highly accurate but less than phase contrast techniques and only accurate when concomitant valvular disease is absent. Comparison of both aortic and ventricular data for internal data verification ensures fidelity of aortic regurgitant data. CMR data can be applied to many types of aortic valve regurgitation including combined aortic stenosis with regurgitation, congenital valve diseases and post-transcatheter valve placement. CMR also predicts those patients who progress to surgery with high overall sensitivity and specificity. Future studies of CMR in patients with aortic regurgitation to quantify the incremental benefit over echocardiography as well as prediction of cardiovascular events are warranted.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Imagem Cinética por Ressonância Magnética/métodos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Progressão da Doença , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tempo para o Tratamento
14.
J Cardiovasc Comput Tomogr ; 12(2): 125-130, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29217341

RESUMO

BACKGROUND: The Coronary Artery Disease Reporting and Data System (CAD-RADS) provides a lexicon and standardized reporting system for coronary CT angiography. OBJECTIVES: To evaluate inter-observer agreement of the CAD-RADS among an panel of early career and expert readers. METHODS: Four early career and four expert cardiac imaging readers prospectively and independently evaluated 50 coronary CT angiography cases using the CAD-RADS lexicon. All readers assessed image quality using a five-point Likert scale, with mean Likert score ≥4 designating high image quality, and <4 designating moderate/low image quality. All readers were blinded to medical history and invasive coronary angiography findings. Inter-observer agreement for CAD-RADS assessment categories and modifiers were assessed using intra-class correlation (ICC) and Fleiss' Kappa (κ).The impact of reader experience and image quality on inter-observer agreement was also examined. RESULTS: Inter-observer agreement for CAD-RADS assessment categories was excellent (ICC 0.958, 95% CI 0.938-0.974, p < 0.0001). Agreement among expert readers (ICC 0.925, 95% CI 0.884-0.954) was marginally stronger than for early career readers (ICC 0.904, 95% CI 0.852-0.941), both p < 0.0001. High image quality was associated with stronger agreement than moderate image quality (ICC 0.944, 95% CI 0.886-0.974 vs. ICC 0.887, 95% CI 0.775-0.95, both p < 0.0001). While excellent inter-observer agreement was observed for modifiers S (stent) and G (bypass graft) (both κ = 1.0), only fair agreement (κ = 0.40) was observed for modifier V (high risk plaque). CONCLUSION: Inter-observer reproducibility of CAD-RADS assessment categories and modifiers is excellent, except for high-risk plaque (modifier V) which demonstrates fair agreement. These results suggest CAD-RADS is feasible for clinical implementation.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Bases de Dados Factuais/normas , Projetos de Pesquisa/normas , Ponte de Artéria Coronária , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Humanos , Variações Dependentes do Observador , Intervenção Coronária Percutânea/instrumentação , Placa Aterosclerótica , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Stents , Calcificação Vascular/diagnóstico por imagem
15.
Am J Cardiol ; 119(7): 1074-1081, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28153348

RESUMO

In subjects with aortic regurgitation (AR) or mitral regurgitation (MR), transthoracic echocardiography (TTE) is recommended for surveillance. Few prospective studies have directly compared the ability of TTE and cardiac magnetic resonance (CMR) to predict clinical outcomes in AR and MR. We hypothesized that, given its higher reproducibility, CMR would predict the need for valve surgery or heart failure (HF) hospitalization better than TTE. Quantitative TTE and CMR were performed on the same day for 51 subjects: 29 with chronic AR and 22 with chronic, primary MR for quantification of valve regurgitation. Baseline measurements of valve regurgitation were compared to the combined primary end point of new HF and valve surgery using receiver operating characteristics, simple logistic regression, and Kaplan-Meier survival analyses. The primary end point occurred in 5 AR subjects (all surgery) and 8 MR subjects (7 surgery, 1 HF) after a mean follow-up of 4.4 ± 1.5 years. For AR, CMR-derived regurgitant volume >50 ml identified those at high risk with 50% undergoing valve surgery versus 0% for those with regurgitant volume ≤50 ml and was more strongly associated with outcomes than regurgitant volume by TTE (p <0.05). For MR, 6.8% of those with regurgitant volume by TTE ≤30 ml developed the primary end point versus 70% in those with regurgitant volume >30 ml. Regurgitant volume by CMR showed no significant separation of survival curves for MR. In conclusion, regurgitant volume by CMR was more predictive of outcomes than by TTE in subjects with AR. In MR, the 2 methods performed similarly.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/terapia , Doença Crônica , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/terapia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
16.
Heart ; 102(4): 298-302, 2016 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-26729695

RESUMO

OBJECTIVE: Cardiac magnetic resonance (CMR) has the potential to provide early detection of cardiac involvement in Fabry disease. We aimed to gain further insight into this by assessing a cohort of Fabry patients using CMR. METHODS/RESULTS: Fifty genotype-positive Fabry subjects (age 45±2 years; 50% male) referred for CMR and 39 matched controls (age 40±2 years; 59% male) were recruited. Patients had a mean Mainz severity score index of 15±2 (range 0-46), reflecting an overall mild degree of disease severity. Compared with controls, Fabry subjects had a 34% greater left ventricular mass (LVM) index (82±5 vs 61±2 g/m(2), p=0.001) and had a significantly greater papillary muscle contribution to total LVM (13±1 vs 6±0.5%, p<0.001), even in the absence of left ventricular hypertrophy (LVH). Late gadolinium enhancement (LGE) was present in 15 Fabry subjects (9/21 males and 6/23 females). The most common site for LGE was the basal inferolateral wall (93%, 14/15). There was a positive association between LVM index and LGE. Despite this, there were two males and three females with no LVH that displayed LGE. Of Fabry subjects who were not on enzyme replacement therapy at enrolment (n=28), six were reclassified as having cardiac involvement (four LVH-negative/LGE-positive, one LVH-positive/LGE-positive and one LVH-positive/LGE-negative). CONCLUSIONS: CMR was able to detect cardiac involvement in 48% of this Fabry cohort, despite the overall mild disease phenotype of the cohort. Of those not on ERT, 21% were reclassified as having cardiac involvement allowing improved risk stratification and targeting of therapy.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Doença de Fabry/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Adulto , Cardiomiopatias/tratamento farmacológico , Cardiomiopatias/genética , Diagnóstico Precoce , Terapia de Reposição de Enzimas , Doença de Fabry/tratamento farmacológico , Doença de Fabry/genética , Feminino , Predisposição Genética para Doença , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/genética , Masculino , Pessoa de Meia-Idade , New South Wales , Fenótipo , Valor Preditivo dos Testes , Queensland , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença
17.
Ann Cardiothorac Surg ; 4(4): 341-51, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26309843

RESUMO

OBJECTIVE: Percutaneous valve intervention for severe mitral regurgitation (MR) using the MitraClip is a novel technology. Quantitative assessment of residual MR by transthoracic echocardiography (TTE) is challenging, with multiple eccentric jets and artifact from the clips. Cardiovascular magnetic resonance (CMR) is the reference standard for left and right ventricular volumetric assessment. CMR phase-contrast flow imaging has superior reproducibility for quantitation of MR compared to echocardiography. The objective of this study was to establish the feasibility and reproducibility of CMR in quantitating residual MR after MitraClip insertion in a prospective study. METHODS: Twenty-five patients underwent successful MitraClip insertion. Nine were excluded due to non-magnetic resonance imaging (MRI) compatible implants or arrhythmia, leaving 16 who underwent a comprehensive CMR examination at 1.5 T (Siemens Aera) with multiplanar steady state free precession (SSFP) cine imaging (cine CMR), and phase-contrast flow acquisitions (flow CMR) at the mitral annulus atrial to the MitraClip, and the proximal aorta. Same-day echocardiography was performed with two-dimensional (2D) visualization and Doppler. CMR and echocardiographic data were independently and blindly analyzed by expert readers. Inter-rater comparison was made by concordance correlation coefficient (CCC) with 95% confidence intervals (CIs), and Bland-Altman (BA) methods. RESULTS: Mean age was 79 years, and mean LVEF was 44%±11% by CMR and 54%±16% by echocardiography. Inter-observer reproducibility of echocardiographic visual categorical grading by expert readers was poor, with a CCC of 0.475 (-0.7, 0.74). Echocardiographic Doppler regurgitant fraction reproducibility was modest (CCC 0.59, 0.15-0.84; BA mean difference -3.7%, -38% to 31%). CMR regurgitant fraction reproducibility was excellent (CCC 0.95, 0.86-0.98; BA mean difference -2.4%, -11.9 to 7.0), with a lower mean difference and narrower limits of agreement compared to echocardiography. Categorical severity grading by CMR using published ranges had good inter-observer agreement (CCC 0.86, 0.62-0.95). CONCLUSIONS: CMR performs very well in the quantitation of MR after MitraClip insertion, with excellent reproducibility compared to echocardiographic methods. CMR is a useful technique for the comprehensive evaluation of residual regurgitation in patients after MitraClip. Technical limitations exist for both techniques, and quantitation remains a challenge in some patients.

19.
J Cardiovasc Magn Reson ; 17: 22, 2015 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-25890002

RESUMO

BACKGROUND: Sphingolipid deposition in Fabry disease causes left ventricular (LV) hypertrophy, of which the accurate assessment is essential. Cardiovascular magnetic resonance (CMR) has been proposed as the gold standard. However, there is debate in the literature as to whether papillary muscles and trabeculations (P&T) should be included in LV mass (LVM). METHODS/RESULTS: We examined the accuracy of 2 CMR methods of assessing LVM and LV volumes, including (M inc P&T) or excluding (M ex P&T) P&T, in a cohort of Fabry disease subjects (n = 20) compared to a matched control group (n = 20). Significant differences between the two measurement methods were observed for LV end-diastolic volume, LV end-systolic volume, LVM, and LV ejection fraction (LVEF) in both groups. These differences were significantly greater in the Fabry group compared to controls, except for LVEF. P&T contributed to a greater percentage of LVM in Fabry subjects than controls (20 ± 1% vs 13 ± 2%, p = 0.01). In the control group, both volume-derived methods (M inc P&T or MexP&T) provided accurate SV measurements compared with the internal reference of velocity-encoded aortic flow. In the Fabry group, inclusion of P&T (M inc P&T) resulted in good concordance with phase contrast flow imaging (difference between flow and volume techniques: 1 ± 3 ml, p = 0.7). CONCLUSION: The volumetric contribution of P&T in Fabry disease is markedly increased relative to healthy controls. Failure to account for this results in significant underestimation of LVM and results in misclassification of a proportion of subjects.


Assuntos
Doença de Fabry/diagnóstico , Ventrículos do Coração/patologia , Hipertrofia Ventricular Esquerda/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Músculos Papilares/patologia , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Doença de Fabry/patologia , Doença de Fabry/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/patologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Músculos Papilares/fisiopatologia , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Reprodutibilidade dos Testes , Volume Sistólico , Função Ventricular Esquerda , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA