J Orthop Surg Res ; 19(1): 259, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659060

RESUMO

PURPOSE: The purpose of the study was to describe a novel growth guidance system, which can avoid metal debris and reduce the sliding friction forces, and test the durability and glidability of the system by in vitro test. METHOD: Two major modifications were made to the traditional Shilla system, including the use of ultra-high molecular weight polyethylene (UHMWPE) gaskets to avoid direct contact between the screw and rod, and polishing the surface of the sliding part of the rod. We tested the durability of the system by a fatigue test, which the samples were test on the MTS system for a 10 million cycle of a constant displacement. Pre and post-testing involved weighing the UHMWPE gaskets and observing the wear conditions. The sliding ability were measured by a sliding displacement test. The maximum sliding displacement of the system was measured after a 300 cycles of dynamic compressive loads in a sinusoidal waveform. RESULTS: After the fatigue test, all the UHMWPE gaskets samples showed some of the fretting on the edge of the inner sides, but its still isolated and avoided the friction between the screws and rods. There was no production of metallic fretting around the sliding screws and rods. The average wear mass of the UHMWPE gaskets was 0.002 ± 0.001 g, less than 1.7% of the original mass. In the sliding test, the novel growth guidance system demonstrated the best sliding ability, with an average maximum sliding distance(AMSD) of 35.75 ± 5.73 mm, significantly better than the group of the traditional Shilla technique(AMSD 3.65 ± 0.46 mm, P < 0.0001). CONCLUSION: In conclusion, we modified the Shilla technique and designed a novel growth guidance system by changing the friction interface of sliding screw and rod, which may significantly reduce the metallic debris and promote spine growth. The fatigue test and sliding dislocation test demonstrated the better durability and glidability of the system. An in vivo animal experiment should be performed to further verify the system.


Assuntos
Teste de Materiais , Polietilenos , Escoliose , Humanos , Teste de Materiais/métodos , Fricção , Parafusos Ósseos , Técnicas In Vitro
2.
Front Cell Dev Biol ; 11: 1282573, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37965575

RESUMO

Growing rod implantation, a surgery treatment for EOS (early onset scoliosis), may cause a kind of chronic inflammation called metalosis and all other implant-related complications because of the metal debris released by the implants as a result of fraction and corrosion. There is no complete explanation of immunologic mechanisms of metalosis up to now. This review demonstrates the researches on metalosis from the clinical issues down to basic immunologic mechanisms. Adverse reactions of metal implants are mainly the formation of NLRP3 (nod-like receptor protein 3) inflammasome, primed by TLR4 (toll-like receptor protein 4), activated by phagocytosis and often accompanied by type Ⅳ hypersensitive reaction. Recent studies found that TNF-α (tumor necrosis factor α) also participates in priming, and activation of inflammasome requires disturbance of lysosome and release of cathepsin B. Ca-074Me and MCC950 are therapeutic interventions worth exploring in aseptic loosening of orthopedic implants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA