Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
J Neurol Surg B Skull Base ; 85(4): 358-362, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38966304

RESUMO

Objective Current transnasal endoscopic techniques for sinus and skull base surgery use a single endoscope to provide visualization from one perspective curtailing depth perception and compromising visualization of the instrument-target interface. The view can be blocked by instruments, and collisions between instruments often occur. The objective of this study was to investigate the use of multiportal retrograde endoscopy to provide more accurate manipulation of the surgical target. Design Maxillary antrostomy and frontal sinusotomy were performed on three different cadavers by three different surgeons. A zero-degree rigid endoscope was introduced through the nose for the standard transnasal approach. A flexible endoscope was introduced transorally, directed past the palate superiorly, and then flexed 180 degrees for the retrograde view. Videos of the standard transnasal view from the rigid endoscope and retrograde view from the flexible endoscope were recorded simultaneously. Results All surgeries were able to be performed with dual-screen viewing of the standard and retrograde view. The surgeons noted that they utilized the retrograde view to adjust the location of ends/tips of their instruments. Four surgeons reviewed the videos and individually agreed that the visualization achieved provided a perspective otherwise not attainable with rigid transnasal endoscopy alone. Conclusion High-quality visualization of surgical targets such as the frontal or maxillary ostia can be challenging with rigid endoscopes alone. Multiportal retrograde endoscopy provides proof of concept that additional views of a surgical target can be achieved. Additional work is needed to further develop indications, techniques, and generalizability to targets beyond those investigated here.

2.
Med Image Anal ; 97: 103246, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38943835

RESUMO

Accurate instrument segmentation in the endoscopic vision of minimally invasive surgery is challenging due to complex instruments and environments. Deep learning techniques have shown competitive performance in recent years. However, deep learning usually requires a large amount of labeled data to achieve accurate prediction, which poses a significant workload. To alleviate this workload, we propose an active learning-based framework to generate synthetic images for efficient neural network training. In each active learning iteration, a small number of informative unlabeled images are first queried by active learning and manually labeled. Next, synthetic images are generated based on these selected images. The instruments and backgrounds are cropped out and randomly combined with blending and fusion near the boundary. The proposed method leverages the advantage of both active learning and synthetic images. The effectiveness of the proposed method is validated on two sinus surgery datasets and one intraabdominal surgery dataset. The results indicate a considerable performance improvement, especially when the size of the annotated dataset is small. All the code is open-sourced at: https://github.com/HaonanPeng/active_syn_generator.

3.
Comput Med Imaging Graph ; 108: 102248, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37315397

RESUMO

Endoscopic endonasal surgery is a medical procedure that utilizes an endoscopic video camera to view and manipulate a surgical site accessed through the nose. Despite these surgeries being video recorded, these videos are seldom reviewed or even saved in patient files due to the size and length of the video file. Editing to a manageable size may necessitate viewing 3 h or more of surgical video and manually splicing together the desired segments. We suggest a novel multi-stage video summarization procedure utilizing deep semantic features, tool detections, and video frame temporal correspondences to create a representative summarization. Summarization by our method resulted in a 98.2% reduction in overall video length while preserving 84% of key medical scenes. Furthermore, resulting summaries contained only 1% of scenes with irrelevant detail such as endoscope lens cleaning, blurry frames, or frames external to the patient. This outperformed leading commercial and open source summarization tools not designed for surgery, which only preserved 57% and 46% of key medical scenes in similar length summaries, and included 36% and 59% of scenes containing irrelevant detail. Experts agreed that on average (Likert Scale = 4) that the overall quality of the video was adequate to share with peers in its current state.


Assuntos
Endoscopia , Base do Crânio , Humanos
4.
Int J Comput Assist Radiol Surg ; 17(2): 249-260, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34888754

RESUMO

PURPOSE: Endoscopic sinus surgery (ESS) is typically guided under preoperative computed tomography (CT), which increasingly diverges from actual patient anatomy as the surgery progresses. Studies have reported that the revision surgery rate in ESS ranges between 28 and 47%. This paper presents a method that can update the preoperative CT in real time to improve surgical completeness in ESS. APPROACH: The work presents and compares three novel methods that use instrument motion data and anatomical structures to predict surgical modifications in real time. The methods use learning techniques, such as nonparametric filtering and Gaussian process regression, to correlate surgical modifications with instrument tip positions, tip trajectories, and instrument shapes. Preoperative CT image sets are updated with modification predictions to serve as a virtual intraoperative CT. RESULTS: The three methods were compared in eight ESS cadaver cases, which were performed by five surgeons and included the following representative ESS operations: maxillary antrostomy, uncinectomy, anterior and posterior ethmoidectomy, and sphenoidotomy. Experimental results showed accuracy metrics that were clinically acceptable with dice similarity coefficients > 86%, with F-score > 92% and precision > 89.91% in surgical completeness evaluation. Among the three methods, the tip trajectory-based estimator had the highest precision of 96.87%. CONCLUSIONS: This work demonstrated that virtually modified intraoperative CT scans improved the consistency between the actual surgical scene and the reference model, and could lead to improved surgical completeness in ESS. Compared to actual intraoperative CT scans, the proposed method has no impact on existing surgical protocols, does not require extra hardware, does not expose the patient to radiation, and does not lengthen time under anesthesia.


Assuntos
Endoscopia , Seios Paranasais , Cadáver , Humanos , Seios Paranasais/diagnóstico por imagem , Seios Paranasais/cirurgia , Tomografia Computadorizada por Raios X
5.
Telemed J E Health ; 28(7): 1050-1057, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34797741

RESUMO

Background: There are well-recognized challenges to delivering specialty health care in rural settings. These challenges are particularly evident for specialized surgical health care due to the lack of trained operators in rural communities. Telerobotic surgery could have a significant impact on the rural-urban health care gap, but thus far, the promise of this method of health care delivery has gone unrealized. With the increasing adoption of telehealth over the past year, along with the maturation of telecommunication and robotic technologies over the past 2 decades, a reappraisal of the opportunities and barriers to widespread implementation of telerobotic surgery is warranted. Here we report the outcome of a rural telerobotic stakeholder workshop to explore modern-day issues critical to the advancement of telerobotic surgical health care. Materials and Methods: We assembled a multidisciplinary stakeholder panel to participate in a 2-day Rural Telerobotic Surgery Stakeholder Workshop. Participants had diverse expertise, including specialty surgeons, technology experts, and representatives of the broader telerobotic health care ecosystem, including economists, lawyers, regulatory consultants, public health advocates, rural hospital administrators, nurses, and payers. The research team reviewed transcripts from the workshop with themes identified and research questions generated based on stakeholder comments and feedback. Results: Stakeholder discussions fell into four general themes, including (1) operating room team interactions, (2) education and training, (3) network and security, and (4) economic issues. The research team then identified several research questions within each of these themes and provided specific research strategies to address these questions. Conclusions: There are still important unanswered questions regarding the implementation and adoption of rural telerobotic surgery. Based on stakeholder feedback, we have developed a research agenda along with suggested strategies to address outstanding research questions. The successful execution of these research opportunities will fill critical gaps in our understanding of how to advance the widespread adoption of rural telerobotic health care.


Assuntos
Robótica , Telemedicina , Atenção à Saúde , Ecossistema , Hospitais Rurais , Humanos
6.
Cardiovasc Digit Health J ; 3(6): 313-319, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36589313

RESUMO

Background: Telerobotic surgery could improve access to specialty procedures such as cardiac catheter ablation in rural and underserved regions in the United States and worldwide. Advancements in telecommunications, internet infrastructure, and surgical robotics are lowering the technical hurdles for this future healthcare delivery paradigm. Nonetheless, important questions remain regarding the safe implementation of telerobotic surgery in rural community hospital settings. Objective: The purpose of this study was to pilot test a system and methods to explore telerobotic cardiac catheter ablation in a rural community hospital setting. Methods: We assembled a portable preclinical telerobotic catheter ablation system from commercial-grade components using third-party vendors. We then carried out 4 telerobotic surgery simulations with an urban surgeon and a rural community hospital operating room (OR) team spanning a distance of more than 2000 miles. Two challenge scenarios were incorporated into the simulations, including loss of network connection and cardiac perforation with subsequent life-threatening tamponade physiology. An ethnographic analysis was then performed. Results: Interviews and observations suggested that rural OR teams readily adapt to the telesurgery context. However, participant perceptions of team trust, communication, and emergency management were significantly altered by the remote location of the surgeon. In addition, most participants believed the OR team would have been better equipped for the challenges had they received formal training or had prior experience with the procedure being simulated. Conclusion: We demonstrate the utility and feasibility of a system and methods for studying specialty telerobotic surgery in a rural hospital OR setting.

7.
Sci Robot ; 6(60): eabi8017, 2021 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-34757801

RESUMO

Robotics is a forward-looking discipline. Attention is focused on identifying the next grand challenges. In an applied field such as medical robotics, however, it is important to plan the future based on a clear understanding of what the research community has recently accomplished and where this work stands with respect to clinical needs and commercialization. This Review article identifies and analyzes the eight key research themes in medical robotics over the past decade. These thematic areas were identified using search criteria that identified the most highly cited papers of the decade. Our goal for this Review article is to provide an accessible way for readers to quickly appreciate some of the most exciting accomplishments in medical robotics over the past decade; for this reason, we have focused only on a small number of seminal papers in each thematic area. We hope that this article serves to foster an entrepreneurial spirit in researchers to reduce the widening gap between research and translation.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica/tendências , Pesquisa Translacional Biomédica/tendências , História do Século XXI , Humanos , Laparoscopia , Desenho de Prótese , Publicações , Pesquisadores , Robótica/história , Pesquisa Translacional Biomédica/história
8.
Sensors (Basel) ; 21(15)2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34372398

RESUMO

Accurate semantic image segmentation from medical imaging can enable intelligent vision-based assistance in robot-assisted minimally invasive surgery. The human body and surgical procedures are highly dynamic. While machine-vision presents a promising approach, sufficiently large training image sets for robust performance are either costly or unavailable. This work examines three novel generative adversarial network (GAN) methods of providing usable synthetic tool images using only surgical background images and a few real tool images. The best of these three novel approaches generates realistic tool textures while preserving local background content by incorporating both a style preservation and a content loss component into the proposed multi-level loss function. The approach is quantitatively evaluated, and results suggest that the synthetically generated training tool images enhance UNet tool segmentation performance. More specifically, with a random set of 100 cadaver and live endoscopic images from the University of Washington Sinus Dataset, the UNet trained with synthetically generated images using the presented method resulted in 35.7% and 30.6% improvement over using purely real images in mean Dice coefficient and Intersection over Union scores, respectively. This study is promising towards the use of more widely available and routine screening endoscopy to preoperatively generate synthetic training tool images for intraoperative UNet tool segmentation.


Assuntos
Endoscopia , Processamento de Imagem Assistida por Computador , Humanos , Semântica
9.
Int J Comput Assist Radiol Surg ; 16(6): 933-941, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34009539

RESUMO

PURPOSE: Computational surgical planning tools could help develop novel skull base surgical approaches that improve safety and patient outcomes. This defines a need for automated skull base segmentation to improve the usability of surgical planning software. The objective of this work was to design and validate an algorithm for atlas-based automated segmentation of skull base structures in individual image sets for skull base surgical planning. METHODS: Advanced Normalization Tools software was used to construct a synthetic CT template from 6 subjects, and skull base structures were manually segmented to create a reference atlas. Landmark registration followed by Elastix deformable registration was applied to the template to register it to each of the 30 trusted reference image sets. Dice coefficient, average Hausdorff distance, and clinical usability scoring were used to compare the atlas segmentations to those of the trusted reference image sets. RESULTS: The mean for average Hausdorff distance for all structures was less than 2 mm (mean for 95th percentile Hausdorff distance was less than 5 mm). For structures greater than 2.5 mL in volume, the average Dice coefficient was 0.73 (range 0.59-0.82), and for structures less than 2.5 mL in volume the Dice coefficient was less than 0.7. The usability scoring survey was completed by three experts, and all structures met the criteria for acceptable effort except for the foramen spinosum, rotundum, and carotid artery, which required more than minor corrections. CONCLUSION: Currently available open-source algorithms, such as the Elastix deformable algorithm, can be used for automated atlas-based segmentation of skull base structures with acceptable clinical accuracy and minimal corrections with the use of the proposed atlas. The first publicly available CT template and anterior skull base segmentation atlas being released (available at this link: http://hdl.handle.net/1773/46259 ) with this paper will allow for general use of automated atlas-based segmentation of the skull base.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Cuidados Pré-Operatórios/métodos , Base do Crânio/diagnóstico por imagem , Software , Adolescente , Adulto , Feminino , Humanos , Masculino , Procedimentos Neurocirúrgicos , Base do Crânio/cirurgia , Adulto Jovem
10.
World Neurosurg ; 142: 29-42, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32599213

RESUMO

In the present report, we have broadly outlined the potential advances in the field of skull base surgery, which might occur within the next 20 years based on the many areas of current research in biology and technology. Many of these advances will also be broadly applicable to other areas of neurosurgery. We have grounded our predictions for future developments in an exploration of what patients and surgeons most desire as outcomes for care. We next examined the recent developments in the field and outlined several promising areas of future improvement in skull base surgery, per se, as well as identifying the new hospital support systems needed to accommodate these changes. These include, but are not limited to, advances in imaging, Raman spectroscopy and microscopy, 3-dimensional printing and rapid prototyping, master-slave and semiautonomous robots, artificial intelligence applications in all areas of medicine, telemedicine, and green technologies in hospitals. In addition, we have reviewed the therapeutic approaches using nanotechnology, genetic engineering, antitumor antibodies, and stem cell technologies to repair damage caused by traumatic injuries, tumors, and iatrogenic injuries to the brain and cranial nerves. Additionally, we have discussed the training requirements for future skull base surgeons and stressed the need for adaptability and change. However, the essential requirements for skull base surgeons will remain unchanged, including knowledge, attention to detail, technical skill, innovation, judgment, and compassion. We believe that active involvement in these rapidly evolving technologies will enable us to shape some of the future of our discipline to address the needs of both patients and our profession.


Assuntos
Inteligência Artificial/tendências , Procedimentos Neurocirúrgicos/tendências , Procedimentos Ortopédicos/tendências , Impressão Tridimensional/tendências , Procedimentos Cirúrgicos Robóticos/tendências , Base do Crânio/cirurgia , Previsões , Engenharia Genética/métodos , Engenharia Genética/tendências , Humanos , Procedimentos Neurocirúrgicos/métodos , Procedimentos Ortopédicos/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Análise Espectral Raman/métodos , Transplante de Células-Tronco/métodos , Transplante de Células-Tronco/tendências
11.
JAMA Facial Plast Surg ; 21(3): 237-243, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30730533

RESUMO

IMPORTANCE: There is no imaging standard to model nasal cartilage for the planning of rhinoplasty procedures. Preoperative visualization of cartilage may improve objective evaluation of nasal deformities, surgical planning, and surgical reconstruction. OBJECTIVES: To evaluate the feasibility of visualizing nasal cartilage using high resolution micro-computed tomography (CT) compared with the criterion standard of pathologic findings in a cadaveric specimen and to evaluate its accuracy compared with various clinical CT protocols. DESIGN, SETTING, AND PARTICIPANTS: Anatomic study at the University of Washington using single human cadaveric nasal specimens performed from July 10, 2017, to March 30, 2018. INTERVENTIONS: A micro-CT acquisition with 60-micron resolution was obtained of a nasal specimen. The specimen was then scanned with 5 different clinical CT protocols to span both clinical care and machine limits. The specimen was then sectioned in 5-mm axial slices for pathologic analysis. MAIN OUTCOMES AND MEASURES: Micro-CT images were registered to pathologic specimen cross-sections using a graphite fiducial system. Cartilage substructures were manually segmented and analyzed. A library of matched images across the micro-CT and various clinical CT protocols was then developed. Region of interest analysis was performed for each of the cartilage structures and their boundaries on clinical CT protocols and micro-CT, with the outcome of mean (SD) density using Hounsfield units. RESULTS: A single human cadaveric nasal specimen was used to obtain the following results. Lower lateral cartilage, upper lateral cartilage, and septal cartilage were accurately delineated on the micro-CT images compared with pathologic findings. The mean absolute deviation from pathologic findings was 0.30 mm for septal cartilage thickness, 0.98 mm for maximal upper lateral cartilage length, and 1.40 mm for maximal lower lateral cartilage length. On clinical CT protocols, only septal cartilage was well discriminated from boundary. Higher radiation dose resulted in more accurate density measurements of cartilage, but it did not ultimately improve ability to discriminate cartilage. CONCLUSIONS AND RELEVANCE: The results of this anatomic study may represent a notable step toward advancing knowledge of the capabilities and pitfalls of nasal cartilage visualization on CT. Nasal cartilage visualization was feasible on the micro-CT compared with pathologic findings. Future research may further examine the barriers to accurately visualizing upper lateral cartilage and lower lateral cartilage, a prerequisite for clinical application. LEVEL OF EVIDENCE: NA.


Assuntos
Cartilagens Nasais/diagnóstico por imagem , Rinoplastia , Tomografia Computadorizada por Raios X/métodos , Microtomografia por Raio-X/métodos , Cadáver , Estudos de Viabilidade , Humanos , Cartilagens Nasais/patologia
12.
Surg Innov ; 25(5): 476-484, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29947581

RESUMO

Successful multidisciplinary treatment of skull base pathology requires precise preoperative planning. Current surgical approach (pathway) selection for these complex procedures depends on an individual surgeon's experiences and background training. Because of anatomical variation in both normal tissue and pathology (eg, tumor), a successful surgical pathway used on one patient is not necessarily the best approach on another patient. The question is how to define and obtain optimized patient-specific surgical approach pathways? In this article, we demonstrate that the surgeon's knowledge and decision making in preoperative planning can be modeled by a multiobjective cost function in a retrospective analysis of actual complex skull base cases. Two different approaches- weighted-sum approach and Pareto optimality-were used with a defined cost function to derive optimized surgical pathways based on preoperative computed tomography (CT) scans and manually designated pathology. With the first method, surgeon's preferences were input as a set of weights for each objective before the search. In the second approach, the surgeon's preferences were used to select a surgical pathway from the computed Pareto optimal set. Using preoperative CT and magnetic resonance imaging, the patient-specific surgical pathways derived by these methods were similar (85% agreement) to the actual approaches performed on patients. In one case where the actual surgical approach was different, revision surgery was required and was performed utilizing the computationally derived approach pathway.


Assuntos
Procedimentos Neurocirúrgicos/educação , Procedimentos Neurocirúrgicos/métodos , Base do Crânio/cirurgia , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Semântica , Base do Crânio/diagnóstico por imagem , Tomografia Computadorizada por Raios X
13.
Int J Med Robot ; 14(1)2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29105281

RESUMO

BACKGROUND: Complete brain tumour resection is an extremely critical factor for patients' survival rate and long-term quality of life. This paper introduces a prototype medical robotic system that aims to automatically detect and clean up brain tumour residues after the removal of tumour bulk through conventional surgery. METHODS: We focus on the development of an integrated surgical robotic system for image-guided robotic brain surgery. The Behavior Tree framework is explored to coordinate cross-platform medical subtasks. RESULTS: The integrated system was tested on a simulated laboratory platform. Results and performance indicate the feasibility of supervised semi-automation for residual brain tumour ablation in a simulated surgical cavity with sub-millimetre accuracy. The modularity in the control architecture allows straightforward integration of further medical devices. CONCLUSIONS: This work presents a semi-automated laboratory setup, simulating an intraoperative robotic neurosurgical procedure with real-time endoscopic image guidance and provides a foundation for the future transition from engineering approaches to clinical application.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Glioma/diagnóstico por imagem , Glioma/cirurgia , Procedimentos Cirúrgicos Robóticos , Técnicas Estereotáxicas , Cirurgia Assistida por Computador/métodos , Encéfalo , Desenho Assistido por Computador , Endoscopia , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Procedimentos Neurocirúrgicos , Processamento de Sinais Assistido por Computador , Software
14.
J Neurol Surg B Skull Base ; 78(6): 490-496, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29134168

RESUMO

Background Most existing objective surgical motion analysis schemes are limited to structured surgical tasks or recognition of motion patterns for certain categories of surgeries. Analyzing instrument motion data with respect to anatomical structures can break the limit, and an anatomical region segmentation algorithm is required for the analysis. Methods An atlas was generated by manually segmenting the skull base into nine regions, including left/right anterior/posterior ethmoid sinuses, frontal sinus, left and right maxillary sinuses, nasal airway, and sphenoid sinus. These regions were selected based on anatomical and surgical significance in skull base and sinus surgery. Six features, including left and right eye center, nasofrontal beak, anterior tip of nasal spine, posterior edge of hard palate at midline, and clival body at foramen magnum, were used for alignment. The B-spline deformable registration was adapted to fine tune the registration, and bony boundaries were automatically extracted for final precision improvement. The resultant deformation field was applied to the atlas, and the motion data were clustered according to the deformed atlas. Results Eight maxillofacial computed tomography scans were used in experiments. One was manually segmented as the atlas. The others were segmented by the proposed method. Motion data were clustered into nine groups for every dataset and outliers were filtered. Conclusions The proposed algorithm improved the efficiency of motion data clustering and requires limited human interaction in the process. The anatomical region segmentations effectively filtered out the portion of motion data that are out of surgery sites and grouped them according to anatomical similarities.

15.
IEEE Robot Autom Lett ; 2(3): 1312-1319, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29130067

RESUMO

Haptic feedback is a critical but a clinically missing component in robotic Minimally Invasive Surgeries. This paper proposes a Gaussian Process Regression(GPR) based scheme to address the gripping force estimation problem for clinically commonly used elongated cable-driven surgical instruments. Based on the cable-driven mechanism property studies and surgical robotic system properties, four different Gaussian Process Regression filters were designed and analyzed, including: one GPR filter with 2-dimensional inputs, one GPR filter with 3-dimensional inputs, one GPR Unscented Kalman Filter (UKF) with 2-dimensional inputs, and one GPR UKF with 3-dimensional inputs. The four proposed methods were compared with the dynamic model based UKF filter on a 10mm gripper on the Raven-II surgical robot platform. The experimental results demonstrated that the four proposed methods outperformed the dynamic model based method on precision and reliability without parameter tuning. And surprisingly, among the four methods, the simplest GPR Filter with 2-dimensional inputs has the best performance.

16.
J Med Imaging (Bellingham) ; 4(3): 034501, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28744478

RESUMO

We present a fully automatic method for segmenting orbital structures (globes, optic nerves, and extraocular muscles) in CT images. Prior anatomical knowledge, such as shape, intensity, and spatial relationships of organs and landmarks, were utilized to define a volume of interest (VOI) that contains the desired structures. Then, VOI was used for fast localization and successful segmentation of each structure using predefined rules. Testing our method with 30 publicly available datasets, the average Dice similarity coefficient for right and left sides of [0.81, 0.79] eye globes, [0.72, 0.79] optic nerves, and [0.73, 0.76] extraocular muscles were achieved. The proposed method is accurate, efficient, does not require training data, and its intuitive pipeline allows the user to modify or extend to other structures.

17.
J Neurol Surg B Skull Base ; 78(3): 222-226, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28603682

RESUMO

Objectives Describe instrument motion during live endoscopic skull base surgery (ESBS) and evaluate kinematics within anatomic regions. Design Case series. Setting Tertiary academic center. Participants A single skull base surgeon performed six anterior skull base approaches to the pituitary. Main Outcomes and Measures Time-stamped instrument coordinates were recorded using an optical tracking system. Kinematics (i.e., mean cumulative instrument travel, velocity, acceleration, and angular velocity) was calculated by anatomic region including nasal vestibule, anterior and posterior ethmoid, sphenoid, and lateral opticocarotid recess (lOCR) regions. Results We observed mean (standard deviation, SD) velocities of 6.14 cm/s (1.55) in the nasal vestibule versus 1.65 cm/s (0.34) near the lOCR. Mean (SD) acceleration was 7,480 cm/s 2 (5790) in the vestibule versus 928 cm/s 2 (662) near the lOCR. Mean (SD) angular velocity was 17.2 degrees/s (8.31) in the vestibule and 5.37 degrees/s (1.09) near the lOCR. We observed a decreasing trend in the geometric mean velocity, acceleration, and angular velocity when approaching the pituitary ( p < 0.001). Conclusion Using a novel method for analyzing instrument motion during live ESBS, we observed a decreasing trend in kinematics with proximity to the pituitary. Additional characterization of surgical instrument motion is paramount for optimizing patient safety and training.

18.
Surg Innov ; 24(4): 405-410, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28412879

RESUMO

OBJECTIVE: To develop a method to measure intraoperative surgical instrument motion. This model will be applicable to the study of surgical instrument kinematics including surgical training, skill verification, and the development of surgical warning systems that detect aberrant instrument motion that may result in patient injury. DESIGN: We developed an algorithm to automate derivation of surgical instrument kinematics in an endoscopic endonasal skull base surgery model. Surgical instrument motion was recorded during a cadaveric endoscopic transnasal approach to the pituitary using a navigation system modified to record intraoperative time-stamped Euclidian coordinates and Euler angles. Microdebrider tip coordinates and angles were referenced to the cadaver's preoperative computed tomography scan allowing us to assess surgical instrument kinematics over time. A representative cadaveric endoscopic endonasal approach to the pituitary was performed to demonstrate feasibility of our algorithm for deriving surgical instrument kinematics. CONCLUSIONS: Technical feasibility of automatically measuring intraoperative surgical instrument motion and deriving kinematics measurements was demonstrated using standard navigation equipment.


Assuntos
Algoritmos , Endoscopia/métodos , Processamento de Imagem Assistida por Computador/métodos , Cavidade Nasal , Procedimentos Neurocirúrgicos/métodos , Base do Crânio , Humanos , Monitorização Intraoperatória , Movimento (Física) , Cavidade Nasal/diagnóstico por imagem , Cavidade Nasal/cirurgia , Base do Crânio/diagnóstico por imagem , Base do Crânio/cirurgia , Cirurgia Assistida por Computador/métodos , Instrumentos Cirúrgicos
19.
Med Phys ; 44(5): 2020-2036, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28273355

RESUMO

PURPOSE: Automated delineation of structures and organs is a key step in medical imaging. However, due to the large number and diversity of structures and the large variety of segmentation algorithms, a consensus is lacking as to which automated segmentation method works best for certain applications. Segmentation challenges are a good approach for unbiased evaluation and comparison of segmentation algorithms. METHODS: In this work, we describe and present the results of the Head and Neck Auto-Segmentation Challenge 2015, a satellite event at the Medical Image Computing and Computer Assisted Interventions (MICCAI) 2015 conference. Six teams participated in a challenge to segment nine structures in the head and neck region of CT images: brainstem, mandible, chiasm, bilateral optic nerves, bilateral parotid glands, and bilateral submandibular glands. RESULTS: This paper presents the quantitative results of this challenge using multiple established error metrics and a well-defined ranking system. The strengths and weaknesses of the different auto-segmentation approaches are analyzed and discussed. CONCLUSIONS: The Head and Neck Auto-Segmentation Challenge 2015 was a good opportunity to assess the current state-of-the-art in segmentation of organs at risk for radiotherapy treatment. Participating teams had the possibility to compare their approaches to other methods under unbiased and standardized circumstances. The results demonstrate a clear tendency toward more general purpose and fewer structure-specific segmentation algorithms.


Assuntos
Algoritmos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Cabeça , Humanos , Pescoço
20.
J Neurol Surg B Skull Base ; 78(1): 99-104, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28180051

RESUMO

Objectives The objective of this study was to evaluate region-specific surgical instrument kinematics among novice and experienced surgeons performing endoscopic endonasal skull base surgery. Design Cadaveric experimental study. Setting Tertiary academic center. Participants Two novice and two experienced surgeons performed eight endoscopic total ethmoidectomies and sphenoidotomies using an optically tracked microdebrider. Main Outcome Measures Time-stamped Euclidian coordinates were recorded. Cumulative instrument travel, mean linear velocity and acceleration, and mean angular velocities were calculated in the anterior ethmoid, posterior ethmoid, and sphenoid sinus regions. Results Mean cumulative instrument travel (standard deviation) was highest in the posterior ethmoid region for both novice and experienced surgeons (9,795 mm [1,664] vs. 3,833 mm [1,080]). There was a trend in mean linear and angular velocities, and acceleration with increasing magnitudes for experienced surgeons compared with novices. Among experienced surgeons, we observed a trend of decreasing yaw velocity during the approach to the surgical target. Conclusions We present a novel method of evaluating surgical instrument motion with respect to anatomical regions of the skull base during endoscopic endonasal skull base surgery. These data may be used in the development of surgical monitoring and training systems to optimize patient safety.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA