Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Orthod Dentofacial Orthop ; 146(3): 319-27, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25172254

RESUMO

INTRODUCTION: The aim was to study nickel-titanium closed-coil springs in a clinically relevant test setting with respect to the accuracy of the "preactivation" for nickel-titanium closed-coil springs application and whether it is possible to keep activation forces constant during the whole time of treatment. METHODS: We tested 10 types of springs from 5 manufacturers under clinically relevant conditions, allowing us to study the interactions between load and temperature over time. Hystereses were compared using t tests. RESULTS: Springs with a large mechanical hysteresis also showed a large thermal hysteresis. After heating shock, these springs showed intensive force spikes and persistent high loads. Some springs showed negligible thermal and mechanical hysteresis. Such springs never showed any clinically significant persistent high loads. CONCLUSIONS: Springs with a large hysteresis were unable to keep activation forces constant during the whole time of treatment even after any preactivation, and they might cause persistently high loads and possibly overloading. Only springs with minor hysteresis, low temperature dependence of force, and a clinically useful plateau have the following clinical advantages: reduced chair time, optimal rates of tooth movement, reproducible clinical results, and conservation of anchorage.


Assuntos
Ligas Dentárias/química , Níquel/química , Fios Ortodônticos , Titânio/química , Temperatura Baixa , Análise do Estresse Dentário/instrumentação , Elasticidade , Temperatura Alta , Humanos , Teste de Materiais , Fenômenos Mecânicos , Estresse Mecânico , Termodinâmica , Torção Mecânica
2.
Amyloid ; 21(1): 57-61, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24479650

RESUMO

We present a case study of an elderly woman with systemic lambda-type AL amyloidosis that featured unusually extensive cutaneous involvement. The case initially presented with a sudden hyper ß-carotenemia with carotenoderma that instigated the clinical examination including skin biopsy. A diagnosis of systemic amyloidosis was made. Immunohistochemistry and Western-blot analysis indicated the presence of lambda light chain proteins in skin amyloid deposits. However, notable co-deposition of wild-type apoA-I and transthyretin was observed which caused initial diagnostic confusion. Proteomic analysis of microdissected skin amyloid deposits by mass spectrometry confirmed lambda light chain proteins in amyloid deposits and co-deposition of apolipoprotein A-IV and serum amyloid P-component. The patient died from renal failure caused by amyloid nephropathy combined with analgesic nephropathy. The autopsy disclosed vascular, cardiac, renal and pulmonary amyloid deposition. While all amyloid deposits were positive for lambda light chain proteins, the immunodetection of apoA-I and transthyretin varied significantly among the visceral amyloid deposits. Although the patient exhibited a 1000-fold increase in serum ß-carotene levels, only a mild increase in retinol and lutein concentrations was observed. Increased ß-carotene values were also found in the liver and the skin. The mechanisms underlying this hyper ß-carotenemia remain undetermined.


Assuntos
Amiloidose/diagnóstico , Hiperpigmentação/diagnóstico , Idoso , Amiloide/metabolismo , Amiloidose/sangue , Evolução Fatal , Feminino , Humanos , Hiperpigmentação/sangue , Pigmentação da Pele , beta Caroteno/sangue
3.
J Appl Clin Med Phys ; 14(3): 4203, 2013 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-23652250

RESUMO

The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired once a week immediately after the alignment. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed 1 cm safety margin. Alternative plans assuming smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with initial ones. While the margin reduction in case of BL setup makes the prostate coverage significantly worse (p = 0.0003, McNemar's test), in case of FM setup with the reduced 7 mm margin, the prostate coverage is even better compared to BL setup with 10 mm margin (p = 0.049, Fisher's exact test). Moreover, partial volumes of organs at risk irradiated with a specific dose can be significantly lowered (p < 0.0001, unpaired t-test). Reducing of safety margin is not acceptable in case of BL setup, while the margin can be lowered from 10 mm to 7 mm in case of FM setup.


Assuntos
Adenocarcinoma/radioterapia , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Marcadores Fiduciais , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
4.
Rep Pract Oncol Radiother ; 17(3): 134-40, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-24377014

RESUMO

AIM: To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. BACKGROUND: Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. MATERIALS AND METHODS: Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. RESULTS: In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. CONCLUSION: Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA