Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
1.
Surg Case Rep ; 10(1): 87, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625458

RESUMO

CASE PRESENTATION: A 61-year-old female was referred to our hospital with a neoplastic lesion in the duodenum. Computed tomography with contrast enhancement revealed a 10-mm tumor in the duodenum. Upper gastrointestinal endoscopy revealed a submucosal tumor-like lesion in the descending part of the duodenum. Endoscopic ultrasound revealed a well-defined hypoechoic tumor. Biopsy and immunohistochemical findings including negative Synaptophysin and Chromogranin A staining and positive Trypsin and BCL10 staining suggested a carcinoma with acinar cell differentiation. Pancreatoduodenectomy was performed, and the resected specimen had a 15-mm solid nodule in the submucosal layer of the duodenum. Pancreatogram of the resected specimen revealed a tumor localized in the accessory papilla region. In histopathological examination, the tumor was found in the submucosa of the duodenum with pancreatic tissue present nearby, and these were separated from the pancreatic parenchyma by the duodenal muscle layer. These findings led to a diagnosis of acinar cell carcinoma originating from the accessory papilla of the duodenum. CONCLUSION: Acinar cell carcinoma originating from the accessory papilla of the duodenum is exceptionally rare, with no reported cases to date. The origin was considered to be pancreatic tissue located in the accessory papilla region.

2.
Clin Endosc ; 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38549245

RESUMO

Background/Aims: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) performed at the intrahepatic bile duct segment 3 (B3) is widely used for biliary drainage. Although performing post-puncture procedures is easier in the intrahepatic bile duct segment 2 (B2) when using a conventional oblique-viewing (OV) EUS scope, this method may cause transesophageal puncture and severe adverse events. We evaluated the safety and efficacy of B2 puncture using a novel OV-EUS scope. Methods: In this single-center retrospective study, we prospectively enrolled and collected data from 45 patients who consecutively underwent EUS-HGS procedures with a novel OV-EUS scope between September 2021 and December 2022 at our cancer center. Results: The technical success rates of B2-EUS-HGS and EUS-HGS were 93.3% (42/45) and 97.8% (44/45), respectively. The early adverse event rate was 8.9% (4/45) with no cases of scope changes or transesophageal punctures. The median procedure time was 13 minutes (range, 5-30). Conclusions: B2-EUS-HGS can be performed safely with the novel EG-740UT (Fujifilm) OV-scope without transesophageal puncture and with a high success rate. B2-EUS-HGS using this novel OV scope may be the preferred strategy for EUS-HGS.

3.
Dig Endosc ; 2024 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-38433315

RESUMO

OBJECTIVES: This consensus was developed by the Asian EUS Group (AEG), who aimed to formulate a set of practice guidelines addressing various aspects of endoscopic ultrasound-guided tissue acquisition (EUS-TA). METHODS: The AEG initiated the development of consensus statements and formed an expert panel comprising surgeons, gastroenterologists, and pathologists. Three online consensus meetings were conducted to consolidate the statements and votes. The statements were presented and discussed in the first two consensus meetings and revised according to comments. Final voting was conducted at a third consensus meeting. The Grading of Recommendations, Assessment, Development, and Evaluation system was adopted to define the strength of the recommendations and quality of evidence. RESULTS: A total of 20 clinical questions and statements regarding EUS-TA were formulated. The committee recommended that fine-needle biopsy (FNB) needles be preferred over conventional fine-needle aspiration (FNA) needles for EUS-TA of subepithelial lesions. For solid pancreatic masses, rapid on-site evaluation is not routinely recommended when FNB needles are used. For dedicated FNB needles, fork-tip and Franseen-tip needles have essentially equivalent performance. CONCLUSION: This consensus provides guidance for EUS-TA, thereby enhancing the quality of EUS-TA.

4.
Clin Endosc ; 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38356172

RESUMO

Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is a standard diagnostic method for biliary tract cancer (BTC), and samples obtained in this manner may be used for comprehensive genomic profiling (CGP). This study evaluated the utility of EUS-TA for CGP in a clinical setting and determined the factors associated with the adequacy of CGP in patients with BTC. Methods: CGP was attempted for 105 samples from 94 patients with BTC at the Aichi Cancer Center, Japan, from October 2019 to April 2022. Results: Overall, 77.1% (81/105) of the samples were adequate for CGP. For 22-G or 19-G fine-needle biopsy (FNB), the sample adequacy was 85.7% (36/42), which was similar to that of surgical specimens (94%, p=0.45). Univariate analysis revealed that 22-G or larger FNB needle usage (86%, p=0.003), the target primary lesions (88%, p=0.015), a target size ≥30 mm (100%, p=0.0013), and number of punctures (90%, p=0.016) were significantly positively associated with CGP sample adequacy. Conclusions: EUS-TA is useful for CGP tissue sampling in patients with BTC. In particular, the use of 22-G or larger FNB needles may allow for specimen adequacy comparable to that of surgical specimens.

5.
J Med Ultrason (2001) ; 51(2): 253-260, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38281237

RESUMO

Advances in next-generation sequencing have made comprehensive genomic profiling (CGP) using tumor tissue specimens and liquid biopsy using blood samples feasible in routine clinical practice. In the context of pancreaticobiliary cancer, it is necessary to consider CGP in formulating individualized treatment strategies. Performing CGP with tumor tissue specimens requires a sufficient number of high-quality samples. EUS-guided tissue acquisition (EUS-TA) is expected to play a significant role in this regard, and endosonographers need to address this role. Here, we review the current status of EUS-TA for CGP focusing on pancreatic cancer and biliary tract cancer.


Assuntos
Neoplasias do Sistema Biliar , Endossonografia , Genômica , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/diagnóstico por imagem , Endossonografia/métodos , Neoplasias do Sistema Biliar/genética , Neoplasias do Sistema Biliar/diagnóstico por imagem , Genômica/métodos , Ultrassonografia de Intervenção/métodos , Sequenciamento de Nucleotídeos em Larga Escala/métodos
6.
J Hepatobiliary Pancreat Sci ; 31(3): 183-192, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38084510

RESUMO

BACKGROUND: We compared the results of preoperative pancreatic juice cytology (PJC) and final pathological diagnosis after resection in patients who underwent resection of intraductal papillary mucinous neoplasm (IPMN) of the pancreas to determine whether preoperative PJC can help determine therapeutic strategies. METHODS: Of 1130 patients who underwent surgical resection IPMN at 11 Japanese tertiary institutions, the study included 852 patients who underwent preoperative PJC guided by endoscopic retrograde cholangiopancreatography (ERCP). RESULTS: The accuracy of preoperative PJC for differentiation between cancerous and noncancerous lesions were 55% for IPMN overall; 59% for the branch duct type; 49% for the main pancreatic duct type; 53% for the mixed type, respectively. On classifying IPMN according to the diameters of the mural nodule (MN) and main pancreatic duct (MPD), the corresponding values for diagnostic performance were 40% for type 1 (MN ≥5 mm and MPD ≥ 10 mm); 46% for type 2 (MN ≥5 mm and MPD < 10 mm); 61% for type 3 (MN < 5 mm and MPD ≥ 10 mm); 72% for type 4 (MN < 5 mm and MPD < 10 mm), respectively. CONCLUSIONS: PJC in IPMN is not a recommended examination because of its low overall sensitivity and no significant difference in diagnostic performance by type, location, or subclassification. Although the sensitivity is low, the positive predictive value is high, so we suggest that pancreatic juice cytology be performed only in cases where the patient is not sure about surgery.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Humanos , Suco Pancreático , Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/cirurgia , Carcinoma Ductal Pancreático/patologia , Neoplasias Intraductais Pancreáticas/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/patologia , Ductos Pancreáticos/cirurgia , Estudos Retrospectivos
7.
Dig Endosc ; 36(2): 206-214, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37186389

RESUMO

OBJECTIVES: Endoscopic ultrasound-guided fine-needle aspiration and fine-needle biopsy (EUS-FNA/FNB) is not fully established as a pathological sampling tool for gallbladder lesions due to limited evidence. We therefore aimed to clarify the effectiveness and safety of this procedure in a large-population cohort. METHODS: This study retrospectively evaluated the diagnostic yield of EUS-FNA/FNB for accurately differentiating between benign and malignant gallbladder lesions. Puncture targets included the gallbladder mass, lymph node, and liver mass. Adverse events and factors associated with diagnostic accuracy were analyzed as well. RESULTS: In 187 patients with gallbladder lesions undergoing EUS-FNA/FNB, 18 benign lesions and 169 malignant lesions were identified. Overall sampling adequacy was 98% (184/187). The diagnostic accuracy of EUS-FNA/FNB was 97% (182/187), sensitivity was 97% (164/169), and specificity was 100% (18/18). A single postprocedural complication (minor bleeding) was recorded in one patient. In the 169 cases of malignancy, 203 sites were punctured for pathological sampling of the primary mass (n = 94), lymph node (n = 79), and metastatic liver mass (n = 30). No significant difference was found for diagnostic accuracy among the puncture sites (P = 0.70). In cases having specimens obtained from the primary mass, the accuracy of those targeting liver invasion sites was significantly higher than that of other sites (98% vs. 83%, P < 0.01). CONCLUSION: EUS-FNA/FNB demonstrated clinical usefulness and safety for the pathological diagnosis of gallbladder lesions, with high diagnostic yield and a low incidence of adverse events. Targeting the site of liver infiltration may improve the diagnostic rate of EUS-FNA/FNB in the primary mass.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas , Humanos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Vesícula Biliar/patologia , Estudos Retrospectivos , Neoplasias Pancreáticas/patologia
8.
Clin Endosc ; 57(2): 246-252, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37743069

RESUMO

BACKGROUND/AIMS: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) is useful for patients with biliary cannulation failure or inaccessible papillae. However, it can lead to serious complications such as bile peritonitis in patients with ascites; therefore, development of a safe method to perform EUS-HGS is important. Herein, we evaluated the safety of EUS-HGS with continuous ascitic fluid drainage in patients with ascites. METHODS: Patients with moderate or severe ascites who underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after the procedure at our institution between April 2015 and December 2022, were included in the study. We evaluated the technical and clinical success rates, EUS-HGS-related complications, and feasibility of re-intervention. RESULTS: Ten patients underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after completion of the procedure. Median duration of ascites drainage before and after EUS-HGS was 2 and 4 days, respectively. Technical success with EUS-HGS was achieved in all 10 patients (100%). Clinical success with EUS-HGS was achieved in 9 of the 10 patients (90 %). No endoscopic complications such as bile peritonitis were observed. CONCLUSION: In patients with ascites, continuous ascites drainage, which is initiated before EUS-HGS and terminated after completion of the procedure, may prevent complications and allow safe performance of EUS-HGS.

9.
Clin Endosc ; 2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37743070

RESUMO

Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is a highly accurate method for diagnosing pancreatic neuroendocrine tumors (PNETs); however, some PNETs are difficult to diagnose. Recently, the efficacy of needle-based confocal laser endomicroscopy (nCLE) in diagnosing solid pancreatic masses has been reported. However, the efficacy of nCLE in the diagnosis of PNETs remains unknown and only a small number of cases have been reported. Hence, this study aimed to evaluate the efficacy of nCLE in the diagnosis of PNETs. Methods: This single-center retrospective study evaluated 30 consecutive patients with suspected PNETs on contrast-enhanced computed tomography, who consented to nCLE combined with EUS-FNA and were diagnosed using EUS-FNA or surgical resection. The diagnostic criteria for PNETs using nCLE were based on the nesting and trabecular and glandular arrangement of tumor cell clusters surrounded by capillary vessels and fibrosis, as reported in previous studies. Results: The diagnosis using nCLE was classified into three categories: misdiagnosis in three cases (10%), non-diagnostic in six cases (20%), and diagnostic in 21 cases (70%). nCLE was able to diagnose PNET in one of the two cases with inconclusive EUS-FNA. Conclusions: Although further development of the resolution and optimization of the diagnostic criteria are required, nCLE may constitute a useful diagnostic option in cases of inconclusive EUS-FNA for PNETs.

10.
Pancreatology ; 23(5): 550-555, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37286439

RESUMO

BACKGROUND/OBJECTIVES: The detection of malignancy is a major concern in the management of intraductal papillary mucinous neoplasm (IPMN). The height of the mural nodule (MN), estimated using endoscopic ultrasound (EUS) and computed tomography (CT), has been considered crucial for predicting malignant IPMN. Currently, whether surveillance using CT or EUS alone is sufficient for detecting MNs remains unclear. This study aimed to compare the ability of CT and EUS to detect MNs in IPMN. METHODS: This multicenter, retrospective observational study was conducted in 11 Japanese tertiary institutions. Patients who underwent surgical resection of IPMN with MN after CT and EUS examinations were eligible to participate. The MN detection rates between CT and EUS were examined. RESULTS: Two-hundred-and-forty patients who underwent preoperative EUS and CT had pathologically confirmed MNs. The MN detection rates of EUS and CT were 83% and 53%, respectively (p < 0.001). Additionally, the MN detection rate of EUS was significantly higher than that of CT regardless of morphological type (76% vs. 47% in branch-duct-type IPMN; 90% vs. 54% in mixed IPMN; 98% vs. 56% in main-duct-type IPMN; p < 0.001). Further, pathologically confirmed MNs ≥5 mm were more frequently observed on EUS than on CT (95% vs. 76%, p < 0.001). CONCLUSIONS: EUS was superior to CT for the detection of MN in IPMN. EUS surveillance is essential for the detection of MNs.


Assuntos
Adenocarcinoma Mucinoso , Carcinoma Ductal Pancreático , Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Humanos , Carcinoma Ductal Pancreático/patologia , Japão , Adenocarcinoma Mucinoso/diagnóstico por imagem , Adenocarcinoma Mucinoso/cirurgia , Adenocarcinoma Mucinoso/patologia , Neoplasias Pancreáticas/patologia , Tomografia Computadorizada por Raios X , Estudos Retrospectivos
11.
Clin Endosc ; 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37157964

RESUMO

Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) through ducts B2 or B3 is effective in most patients with biliary obstruction, because B2 and B3 commonly join together. However, in some patients, B2 and B3 do not join each other due to invasive hilar tumors; therefore, single-route drainage is insufficient. Here, we investigated the feasibility and efficacy of EUS-HGS through both B2 and B3 simultaneously in seven patients. We decided to perform EUS-HGS through both B2 and B3 to achieve adequate biliary drainage because these two ducts were separate from each other. Here, we report a 100% technical and overall clinical success rate. Early adverse effects were closely monitored. Minimal bleeding was reported in one patient (1/7) and mild peritonitis in one patient (1/7). None of the patients experienced stent dysfunction, fever, or bile leakage after the procedure. EUS-HGS through both B2 and B3 simultaneously is safe, feasible, and effective for biliary drainage in patients with separated ducts.

12.
DEN Open ; 3(1): e227, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37064420

RESUMO

Objectives: We surveyed and reported low protective equipment usage and insufficient knowledge among endoscopy-fluoroscopy departments in Japan in 2020. Two years later, we conducted a follow-up survey of doctors, nurses, and technologists in Japan. Methods: We conducted a questionnaire survey on radiation protection from May to June 2022. The participants were medical staff, including doctors, nurses, and radiological and endoscopy technicians in endoscopy-fluoroscopy departments. The questionnaire included 17 multiple-choice questions divided into three parts: background, equipment, and knowledge. Results: We surveyed 464 subjects from 34 institutions. There were 267 doctors (58%), 153 nurses (33%), and 44 technologists (9%). The rate of wearing a lead apron was 98% in this study. The rates of wearing a thyroid collar, lead glasses, and radiation dosimeter were 27%, 35%, and 74%, respectively. The trend of the protective equipment rate was similar to that of our previous study; however, radiation dosimetry among doctors was still low at 58%. The percentage of subjects who knew the radiation exposure (REX) dose of each procedure was low at 18%. Seventy-six percent of the subjects attended lectures on radiation protection, and 73% knew about the three principles of radiation protection; however, the concept of diagnostic reference levels was not well known (18%). Approximately 60% of the subjects knew about the exposure dose increasing cancer mortality (63%) and the 5-year lens REX limit (56%). Conclusions: There was some improvement in radiation protection equipment or education, but relatively little compared to the 2020 survey of endoscopy departments.

13.
Clin Endosc ; 56(2): 221-228, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36879539

RESUMO

BACKGROUND/AIMS: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is essential for the diagnosis of pancreatic cancer. The feasibility of comprehensive genomic profiling (CGP) using samples obtained by EUS-TA has been under recent discussion. This study aimed to evaluate the utility of EUS-TA for CGP in a clinical setting. METHODS: CGP was attempted in 178 samples obtained from 151 consecutive patients with pancreatic cancer at the Aichi Cancer Center between October 2019 and September 2021. We evaluated the adequacy of the samples for CGP and determined the factors associated with the adequacy of the samples obtained by EUS-TA retrospectively. RESULTS: The overall adequacy for CGP was 65.2% (116/178), which was significantly different among the four sampling methods (EUS-TA vs. surgical specimen vs. percutaneous biopsy vs. duodenal biopsy, 56.0% [61/109] vs. 80.4% [41/51] vs. 76.5% [13/17] vs. 100.0% [1/1], respectively; p=0.022). In a univariate analysis, needle gauge/type was associated with adequacy (22 G fine-needle aspiration vs. 22 G fine-needle biopsy [FNB] vs. 19 G-FNB, 33.3% (5/15) vs. 53.5% (23/43) vs. 72.5% (29/40); p=0.022). The sample adequacy of 19 G-FNB for CGP was 72.5% (29/40), and there was no significant difference between 19 G-FNB and surgical specimens (p=0.375). CONCLUSION: To obtain adequate samples for CGP with EUS-TA, 19 G-FNB was shown to be the best in clinical practice. However, 19 G-FNB was not still sufficient, so further efforts are required to improve adequacy for CGP.

14.
Sci Rep ; 13(1): 3262, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36828831

RESUMO

Diagnosing distal bile duct obstruction remains challenging. This study aimed to examine the diagnostic ability of artificial intelligence (AI) based on clinical biomarkers in diagnosing malignant distal bile duct obstruction. A total of 206 patients with distal bile duct obstruction were included in this study. Clinical laboratory parameters were collected from the patients and evaluated using AI. All clinical parameters were input into the AI algorithm, and the AI value for malignant distal bile duct obstruction was calculated. The benign and malignant diagnostic capabilities of AI and other factors (alkaline phosphatase [ALP], intrahepatic bile duct [IHBD] diameters, and total bile duct [CBD] diameters) were compared. Benign and malignant bile duct obstruction were diagnosed in 142 and 64 patients, respectively. The median AI value of malignant distal bile duct obstruction was significantly greater than that of benign distal bile duct obstruction (0.991 vs. 0.002, p < 0.001). The area under the receiver operating characteristic curve of AI, ALP, IHBD diameter, and CBD diameter were 0.908, 0.795, 0.794, and 0.775, respectively. AI showed a sensitivity, specificity, and accuracy of 83.1%, 87.2%, and 85.9%. AI-based on clinical biomarkers could serve as an auxiliary for diagnosing malignant bile duct obstruction.


Assuntos
Inteligência Artificial , Colestase , Humanos , Colestase/patologia , Ductos Biliares/patologia , Biomarcadores , Curva ROC , Estudos Retrospectivos
15.
Clin Endosc ; 56(3): 367-374, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36600657

RESUMO

BACKGROUND/AIMS: Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) using oblique-view EUS in patients with a surgically altered anatomy (SAA) of the upper gastrointestinal tract is limited because of difficult scope insertion due to the disturbed anatomy. This study aimed to investigate the efficiency of forward-view (FV)-EUS in performing FNA in patients with a SAA. METHODS: We retrospectively investigated 32 patients with a SAA of the upper gastrointestinal tract who visited Aichi Cancer Center Hospital in Nagoya, Japan, between January 2014 and December 2020. We performed-upper gastrointestinal EUS-FNA using FV-EUS combined with fluoroscopic imaging to confirm tumor recurrence or to make a decision before chemotherapy or after a failure of diagnosis by radiology. RESULTS: We successfully performed EUS-FNA in all studied patients (100% technical success), with the specificity, sensitivity, and accuracy of 100%, 87.5%, and 87.8%, respectively, with no complications. CONCLUSION: EUS-FNA using FV-EUS combined with fluoroscopic imaging is an effective and safe technique for tissue acquisition in patients with a SAA.

16.
Endoscopy ; 55(2): 140-149, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35688454

RESUMO

BACKGROUND : There are several types of pancreatic mass, so it is important to distinguish between them before treatment. Artificial intelligence (AI) is a mathematical technique that automates learning and recognition of data patterns. This study aimed to investigate the efficacy of our AI model using endoscopic ultrasonography (EUS) images of multiple types of pancreatic mass (pancreatic ductal adenocarcinoma [PDAC], pancreatic adenosquamous carcinoma [PASC], acinar cell carcinoma [ACC], metastatic pancreatic tumor [MPT], neuroendocrine carcinoma [NEC], neuroendocrine tumor [NET], solid pseudopapillary neoplasm [SPN], chronic pancreatitis, and autoimmune pancreatitis [AIP]). METHODS : Patients who underwent EUS were included in this retrospective study. The included patients were divided into training, validation, and test cohorts. Using these cohorts, an AI model that can distinguish pancreatic carcinomas from noncarcinomatous pancreatic lesions was developed using a deep-learning architecture and the diagnostic performance of the AI model was evaluated. RESULTS : 22 000 images were generated from 933 patients. The area under the curve, sensitivity, specificity, and accuracy (95 %CI) of the AI model for the diagnosis of pancreatic carcinomas in the test cohort were 0.90 (0.84-0.97), 0.94 (0.88-0.98), 0.82 (0.68-0.92), and 0.91 (0.85-0.95), respectively. The per-category sensitivities (95 %CI) of each disease were PDAC 0.96 (0.90-0.99), PASC 1.00 (0.05-1.00), ACC 1.00 (0.22-1.00), MPT 0.33 (0.01-0.91), NEC 1.00 (0.22-1.00), NET 0.93 (0.66-1.00), SPN 1.00 (0.22-1.00), chronic pancreatitis 0.78 (0.52-0.94), and AIP 0.73 (0.39-0.94). CONCLUSIONS : Our developed AI model can distinguish pancreatic carcinomas from noncarcinomatous pancreatic lesions, but external validation is needed.


Assuntos
Carcinoma Ductal Pancreático , Aprendizado Profundo , Neoplasias Pancreáticas , Pancreatite Crônica , Humanos , Endossonografia/métodos , Diagnóstico Diferencial , Estudos Retrospectivos , Inteligência Artificial , Neoplasias Pancreáticas/patologia , Carcinoma Ductal Pancreático/diagnóstico , Pancreatite Crônica/diagnóstico por imagem , Neoplasias Pancreáticas
17.
Intern Med ; 62(2): 159-167, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-35705270

RESUMO

Objective The effectiveness of everolimus for the management of pancreatic neuroendocrine neoplasms (PNENs), including the G3/NEC types, remains unclear. We therefore investigated the effectiveness of the drug for the management of PNENs. Methods We analyzed the progression-free survival (PFS) and overall survival (OS) associated with everolimus and factors influencing the PFS and OS. Results One hundred patients were evaluated. The PFS associated with the G1/G2 types tended to be significantly longer than that associated with the G3/NEC types [hazard ratio (HR), 0.45; p=0.005]. A multivariate analysis showed that the significant factors influencing the PFS were age (<65 years old; HR, 0.44; p=0.002), grade (G1/G2; HR, 0.42; p=0.006), everolimus treatment line (≤2nd; HR, 0.55; p=0.031), and presence of treatment with metformin (yes; HR, 0.29; p=0.044). The median OS was 63.8 months. In the multivariate analysis, the significant factors influencing the OS were grade (G1/G2; HR, 0.21; p<0.001), volume of liver metastasis (≤25%; HR, 0.27; p<0.001), everolimus treatment line (≤2nd; HR, 0.27; p<0.001), and presence of primary tumor resection (yes; HR, 0.33; p=0.005). Conclusion The effectiveness of everolimus in the management of G3/NEC types and prognoses tended to be poorer than those associated with the G1/G2 types. Everolimus combined with metformin and early-line treatment with everolimus may be effective for managing advanced PNENs.


Assuntos
Metformina , Tumores Neuroendócrinos , Neoplasias Pancreáticas , Humanos , Idoso , Everolimo/uso terapêutico , Prognóstico , Neoplasias Pancreáticas/patologia , Tumores Neuroendócrinos/cirurgia , Metformina/uso terapêutico
18.
Cancers (Basel) ; 14(22)2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36428761

RESUMO

BACKGROUND: The clinical outcomes of everolimus rechallenge in patients with pancreatic neuroendocrine neoplasms (PNENs) are unknown. This study aimed to investigate the treatment outcomes and safety of everolimus rechallenge treatment with PNENs. METHODS: Clinical data of everolimus-treated patients with PNENs at two institutions were collected. Patients who underwent everolimus rechallenge were included in the study. We analyzed the progression-free survival (PFS) and treatment response associated with everolimus rechallenge and the adverse events. RESULTS: Between 2008 and 2020, 117 patients received initial treatment with everolimus, of which 14 patients received everolimus rechallenge. With regard to the grade of PNENs, there were 2 cases of G1, 11 cases of G2, and 1 case of G3. The median rechallenge PFS was 5.7 months. The objective response rate was 21.4%. the disease control rate was 71.4%. The only major grade 3 or 4 adverse event was neutropenia (n = 1, 7.1%). No other severe adverse event was observed. CONCLUSION: The outcomes and safety of everolimus rechallenge were verified, and it was deemed an acceptable treatment. Everolimus rechallenge may provide a new drug therapy for patients with advanced PNENs for whom no other drug treatment option is available.

19.
Nagoya J Med Sci ; 84(2): 374-387, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35967946

RESUMO

Helicobacter pylori infection is a significant risk factor for gastric cancer. The infection is acquired mainly in early childhood and is influenced by environmental factors, including socioeconomic status and sibling number. However, the impact of socioeconomic status and sibling number on Helicobacter pylori infection has not been well studied in Japan. We conducted a cross-sectional study to evaluate the impact of socioeconomic status, represented by education level, and sibling number on the prevalence of Helicobacter pylori infection among 3,423 non-cancer subjects who visited Aichi Cancer Center between 2005 and 2013. We calculated odds ratios (ORs) and 95% confidence intervals (CIs) using a logistic regression model adjusted for potential confounding variables. Of the 3,423 subjects, 1,459 (42.6%) were Helicobacter pylori-positive. The prevalence of Helicobacter pylori infection linearly decreased with increasing socioeconomic status [ORs (95% CIs) of moderate and high socioeconomic status relative to low socioeconomic status of 0.67 (0.53-0.84) and 0.43 (0.34-0.54), respectively; P trend=9.7×10-17]. In contrast, the prevalence of Helicobacter pylori infection linearly increased with increasing sibling number [ORs (95% CIs) of SN 3-4 and ≥5 relative to sibling number ≤2 of 1.74 (1.47-2.06) and 2.54 (2.12-3.04), respectively; P trend=1.2×10-24]. This study showed that socioeconomic status and sibling number were significantly associated with the prevalence of Helicobacter pylori infection.


Assuntos
Infecções por Helicobacter , Helicobacter pylori , Pré-Escolar , Estudos Transversais , Infecções por Helicobacter/epidemiologia , Humanos , Japão/epidemiologia , Prevalência , Irmãos , Classe Social
20.
Endosc Ultrasound ; 11(4): 319-324, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35848655

RESUMO

Background and Objectives: EUS-guided hepaticogastrostomy (EUS-HGS) is in widespread use; however, there are few dedicated devices. The B2 route is technically easier than the B3 route for guidewire insertion, dilation, and stenting but if performed with conventional oblique-viewing (OV) EUS, B2 puncture can cause transesophageal puncture and severe adverse events. The aim of this study was to assess the efficacy of forward-viewing (FV) EUS, which we have developed to improve safety for B2 puncture in EUS-HGS (B2-EUS-HGS). Patients and Methods: This single-center retrospective study included 61 consecutive patients who underwent B2-EUS-HGS with FV between February 2020 and March 2021 at Aichi Cancer Center, Japan. The patients were prospectively enrolled, and clinical data were retrospectively collected for these 61 cases. Results: The overall technical success rate of EUS-HGS was 98.3% (60/61). The rate of EUS-HGS with FV was 95.0% (58/61) after three cases converted to OV, and that of B2-EUS-HGS with FV was 88.5% (54/61). The early adverse event rate was 6.5% (4/61). There were no instances of transesophageal puncture. Median procedure time was 24 min (range, 8-70), and no patient required cautery dilation. Conclusions: B2-EUS-HGS can be performed safely using FV, without transesophageal puncture, and supportability of the device is improved as FV is coaxial with the guidewire. FV was efficacious in B2-EUS-HGS, which shows promise for clinical application in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA