Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Anesth Analg ; 138(6): 1242-1248, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38180886

RESUMO

BACKGROUND: Perioperative treatment of hypotension by intravenous administration of norepinephrine in a peripheral vein can lead to adverse events, for example, tissue necrosis. However, the incidence and severity of adverse events during perioperative administration are unknown. METHODS: This was a prospective observational study conducted at 3 Swedish hospitals from 2019 to 2022. A total of 1004 patients undergoing surgery, who met the criteria for perioperative peripheral norepinephrine administration, were included. The infusion site was inspected regularly. If swelling or paleness of skin was detected, the infusion site was changed to a different peripheral line. Systolic blood pressure and pulse frequency were monitored during the infusion time and defined as adverse events at >220 mm Hg and <40 beats•min -1 . In case of adverse events, patients were observed for up to 48 hours. The primary outcome was prevalence of extravasation, defined as swelling around the infusion site. Secondary outcomes were all types of adverse events and associations between predefined clinical variables and risk of adverse events. RESULTS: We observed 2.3% (95% confidence interval [CI], 1.4%-3.2%) extravasation of infusion and 0.9% (95% CI, 0.4%-1.7%) bradycardia. No cases of tissue necrosis or severe hypertension were detected. All adverse events had dissipated spontaneously within 48 hours. Proximal catheter placement was associated with more adverse events. CONCLUSIONS: Extravasation of peripherally administrated norepinephrine in the perioperative period occurred at similar rates as in previous studies in critically ill patients. In our setting, where we regularly inspected the infusion site and shifted site in case of swelling or paleness of skin, we observed no case of severe adverse events. Given that severe adverse events were absent, the potential benefit of this preventive approach requires confirmation in a larger population.


Assuntos
Norepinefrina , Vasoconstritores , Humanos , Norepinefrina/administração & dosagem , Norepinefrina/efeitos adversos , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Vasoconstritores/administração & dosagem , Vasoconstritores/efeitos adversos , Suécia/epidemiologia , Infusões Intravenosas , Hipotensão/induzido quimicamente , Hipotensão/diagnóstico , Hipotensão/epidemiologia , Cateterismo Periférico/efeitos adversos , Adulto , Fatores de Risco
2.
PLoS One ; 18(4): e0282724, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37011083

RESUMO

BACKGROUND: High frequency jet ventilation (HFJV) can be used to minimise sub-diaphragmal organ displacements. Treated patients are in a supine position, under general anaesthesia and fully muscle relaxed. These are factors that are known to contribute to the formation of atelectasis. The HFJV-catheter is inserted freely inside the endotracheal tube and the system is therefore open to atmospheric pressure. AIM: The aim of this study was to assess the formation of atelectasis over time during HFJV in patients undergoing liver tumour ablation under general anaesthesia. METHOD: In this observational study twenty-five patients were studied. Repeated computed tomography (CT) scans were taken at the start of HFJV and every 15 minutes thereafter up until 45 minutes. From the CT images, four lung compartments were defined: hyperinflated, normoinflated, poorly inflated and atelectatic areas. The extension of each lung compartment was expressed as a percentage of the total lung area. RESULT: Atelectasis at 30 minutes, 7.9% (SD 3.5, p = 0.002) and at 45 minutes 8,1% (SD 5.2, p = 0.024), was significantly higher compared to baseline 5.6% (SD 2.5). The amount of normoinflated lung volumes were unchanged over the period studied. Only a few minor perioperative respiratory adverse events were noted. CONCLUSION: Atelectasis during HFJV in stereotactic liver tumour ablation increased over the first 45 minutes but tended to stabilise with no impact on normoinflated lung volume. Using HFJV during stereotactic liver ablation is safe regarding formation of atelectasis.


Assuntos
Ventilação em Jatos de Alta Frequência , Neoplasias Hepáticas , Atelectasia Pulmonar , Humanos , Ventilação em Jatos de Alta Frequência/efeitos adversos , Ventilação em Jatos de Alta Frequência/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Tomografia Computadorizada por Raios X , Atelectasia Pulmonar/diagnóstico por imagem , Atelectasia Pulmonar/etiologia
3.
Acta Anaesthesiol Scand ; 65(9): 1248-1253, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34028010

RESUMO

BACKGROUND: High-frequency jet ventilation is necessary to reduce organ movements during stereotactic liver ablation. However, post-operative hypertensive episodes especially following irreversible electroporation ablation compared with microwave ablation initiated this study. The hypothesis was that hypertensive episodes could be related to ventilation or ablation method. METHODS: The aim of this retrospective study was to assess the proportion of patients with hypertensive events during recovery following liver ablation under general anaesthesia and to analyse the relation to ventilation and ablation technique. A medical chart review of 134 patients undergoing either high-frequency jet ventilation and microwave ablation (n = 45), high-frequency jet ventilation and irreversible electroporation (n = 44), or conventional ventilation and microwave ablation (n = 45) was performed. The proportion of patients with at least one episode of systolic arterial pressure 140-160, 160-180 or >180 mmHg during early recovery and the impact of ventilation method was studied. RESULTS: Out of 134 patients, 100, 75 and 34 patients had at least one episode of mild, moderate and severe hypertension. Microwave ablation, as well as high frequency jet ventilation, was associated with an increased odds ratio for post-operative hypertension. The proportion of patients with at least one severe hypertensive event was 18/45, 9/44 and 7/45, respectively. CONCLUSION: Both ventilation and ablation technique had an impact on post-operative hypertensive episodes. The microwave ablation/high-frequency jet ventilation combination increased the risk as compared with irreversible electroporation/high-frequency jet ventilation and microwave ablation/conventional ventilation.


Assuntos
Ventilação em Jatos de Alta Frequência , Hipertensão , Neoplasias Hepáticas , Humanos , Hipertensão/epidemiologia , Neoplasias Hepáticas/cirurgia , Estudos Retrospectivos
4.
Shock ; 54(1): 119-127, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31425404

RESUMO

INTRODUCTION: Suprarenal aortic cross clamping (SRACC) and reperfusion may cause acute pulmonary hypertension and multiple organ failure. HYPOTHESIS: The organic mononitrites of 1,2-propanediol (PDNO), an nitric oxide donor with a very short half-life, are a more efficient pulmonary vasodilator and attenuator of end-organ damage and inflammation without significant side effects compared with nitroglycerin and inorganic nitrite in a porcine SRACC model. METHODS: Anesthetized and instrumented domestic pigs were randomized to either of four IV infusions until the end of the experiment (n = 10 per group): saline (control), PDNO (45 nmol kg min), nitroglycerin (44 nmol kg min), or inorganic nitrite (a dose corresponding to PDNO). Thereafter, all animals were subjected to 90 min of SRACC and 10 h of reperfusion and protocolized resuscitation. Hemodynamic and respiratory variables as well as blood samples were collected and analysed. RESULTS: During reperfusion, mean pulmonary arterial pressure and pulmonary vascular resistance were significantly lower, and stroke volume was significantly higher in the PDNO group compared with the control, nitroglycerin, and inorganic nitrite groups. In parallel, mean arterial pressure, arterial oxygenation, and fraction of methaemoglobin were similar in all groups. The serum concentration of creatinine and tumor necrosis factor alpha were lower in the PDNO group compared with the control group during reperfusion. CONCLUSIONS: PDNO was an effective pulmonary vasodilator and appeared superior to nitroglycerin and inorganic nitrite, without causing significant systemic hypotension, impaired arterial oxygenation, or methaemoglobin formation in an animal model of SRACC and reperfusion. Also, PDNO may have kidney-protective effects and anti-inflammatory properties.


Assuntos
Hipertensão Pulmonar/tratamento farmacológico , Nitroglicerina/farmacologia , Propilenoglicóis/farmacologia , Artéria Pulmonar/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Animais , Modelos Animais de Doenças , Feminino , Hipertensão Pulmonar/fisiopatologia , Infusões Intravenosas , Masculino , Nitritos/administração & dosagem , Nitritos/farmacologia , Nitroglicerina/administração & dosagem , Propilenoglicol/administração & dosagem , Propilenoglicol/farmacologia , Propilenoglicóis/administração & dosagem , Suínos
5.
F1000Res ; 8: 386, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31583085

RESUMO

Background: Stereotactic ablation of tumours in solid organs is a promising curative procedure in clinical oncology. The technique demands minimal target organ movements to optimise tumour destruction and prevent injury to surrounding tissues. High frequency jet ventilation (HFJV) is a novel option during these procedures, reducing the respiratory-associated movements of the liver. The effects of HFJV via endotracheal catheter on gas exchange during liver tumour ablation is not well studied. Methods: The aim of this explorative study was to assess lung function and the effects on blood gas and lactate during HFJV in patients undergoing stereotactic liver ablation. Blood gases were analysed in 25 patients scheduled for stereotactic liver ablation under general anaesthesia pre-induction, every 15 minutes during HFJV and following extubation in the recovery room. The HFJV was set at fixed settings. Results: None of the patients developed hypoxia or signs of increased lactate production but a great variation in PaO 2/FiO 2 ratio was found; from 13.1 to 71.3. An increase in mean PaCO 2 was observed, from a baseline of 5.0 to a peak of 7.1 at 30 minutes (p <0.001) and a decrease was found in median pH, from a baseline of 7.44 to 7.31 at 15 minutes (p=0.03). We could not see any clear association between a decrease in PaO 2/FiO 2 ratio and PaCO 2 elevation. Conclusions: HFJV during general anaesthesia in patients undergoing stereotactic liver ablation is feasible and it did not cause hypoxemia or signs of increased lactate production. A reversible mild to moderate impairment of gas exchange was found during HFJV.


Assuntos
Ventilação em Jatos de Alta Frequência , Neoplasias Hepáticas , Anestesia Geral , Gasometria , Feminino , Humanos , Neoplasias Hepáticas/terapia , Masculino , Respiração
6.
Eur J Radiol Open ; 6: 1-8, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30547062

RESUMO

BACKGROUND: Ablation therapies for tumours are becoming more used as ablation modalities evolve and targeting solutions are getting better. There is an increasing body of long-term results challenging resection and proving lower morbidities and costs. The aim of this paper is to share the experiences from a high-volume centre in introducing computer assisted targeting solutions and efficient ablation modalities like microwave generators and irreversible electroporation. MATERIAL AND METHODS: One thousand consecutive treatments in one high-volume centre were evaluated retrospectively from prospectively collected data. RESULTS: The purpose of this paper is to present the benefits of going into computer assisted targeting techniques and microwave technology; pitfalls and overview of outcomes. The main target organ was the liver and the main indications were ablation of hepatocellular carcinomas and colorectal liver metastases. With the assistance of computer assisted targeting the local recurrence rate within 6 months has dropped from 30 to near 10%. The survival of patients with hepatocellular carcinoma and colorectal liver metastases is not worse if the tumour can be retreated after a local recurrence. Multiple colorectal liver metastases can be treated successfully. DISCUSSION: The incorporation of computer assisted targeting technologies for ultrasound-, ct guided- and laparoscopic tumour ablation has been very successful and without a noticeable learning curve. The same is true for switching from radiofrequency energies to microwave generators and irreversible electroporation. CONCLUSION: It is well worthwhile upgrading ablation and targeting technologies to achieve excellent and reproducible results and minimizing operator dependency.

7.
F1000Res ; 7: 773, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30271582

RESUMO

Background: Computer-assisted navigation during thermal ablation of liver tumours, may help to correct needle placement and improve ablation efficacy in percutaneous, laparoscopic and open interventions. The potential advantage of using high frequency jet-ventilation technique (HFJV) during the procedure is by minimising the amplitude of respiration-related upper-abdominal organs movements. The aim of this clinical methodological trial was to establish whether HFJV would give less ventilatory induced liver movements than conventional ventilation, during stereotactic navigated ablation of liver metastases under open surgery. Methods: Five consecutive patients scheduled for elective, open liver ablation under general propofol and remifentanil anaesthesia were included in the study protocol. During the stereotactic targeting of the tumours, HFJV was chosen for intraoperative lung ventilation. For tracking of liver movement, a rigid marker shield was placed on the liver surface and tracked with an optical position measurement system. A 4D position of the marker shield was measured for HFJV and conventional tidal volume lung ventilation (TV). At each time point the magnitude of liver displacement was calculated as an Euclidean distance between translational component of the marker shield's 3D position and previously estimated centroid of the translational motion. Results: The mean Euclidean liver displacement was 0.80 (0.10) mm for HFJV and 2,90 (1.03) mm for TV with maximum displacement going as far as 12 mm on standard ventilation (p=0.0001). Conclusion: HFJV is a valuable lung ventilation method for patients undergoing stereotactic surgical procedures in general anaesthesia when reduction of organ displacement is crucial.


Assuntos
Ventilação em Jatos de Alta Frequência , Neoplasias Hepáticas/radioterapia , Radiocirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/patologia , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Volume de Ventilação Pulmonar
8.
Int J Immunopathol Pharmacol ; 32: 394632017751486, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29376749

RESUMO

This study evaluated the effects of inhaled nitric oxide (iNO) therapy combined with intravenous (IV) corticosteroids on hemodynamics, selected cytokines, and kidney messenger RNA toll-like receptor 4 (mRNA TLR4) expression in ischemia-reperfusion injury animal model. The primary endpoint was the evaluation of circulatory, respiratory, and renal function over time. We also investigated the profile of selected cytokines and high-mobility group box 1 (HMGB1) protein, as well as renal mRNA TLR4 activation determined by quantitative real-time polymerase chain reaction analysis. Pigs (n = 19) under sevoflurane AnaConDa anesthesia/sedation were randomized and subjected to abdominal laparotomy and alternatively suprarenal aortic cross-clamping (SRACC) for 90 min or sham surgery: Group 1 (n = 8) iNO (80 ppm) + IV corticosteroids (25 mg ×3) started 30 min before SRACC and continued 2 h after SRACC release, followed with decreased iNO (30 ppm) until the end of observation, Group 2 (n = 8) 90 min SRACC, Group 3 (n = 3)-sham surgery. Renal biopsies were sampled 1 hr before SRACC and at 3 and 20 h after SRACC release. Aortic clamping increased TLR4 mRNA expression in ischemic kidneys, but significant changes were recorded only in the control group ( P = 0.016). Treatment with iNO and hydrocortisone reduced TLR4 mRNA expression to pre-ischemic conditions, and the difference observed in mRNA expression was significant between control and treatment group after 3 h ( P = 0.042). Moreover, animals subjected to treatment with iNO and hydrocortisone displayed an attenuated systemic inflammatory response and lowered pulmonary vascular resistance plus increased oxygen delivery. The results indicated that iNO therapy combined with IV corticosteroids improved central and systemic hemodynamics, oxygen delivery, and diminished the systemic inflammatory response and renal mRNA TLR4 expression.


Assuntos
Aorta Abdominal/patologia , Hidrocortisona/administração & dosagem , Óxido Nítrico/administração & dosagem , Traumatismo por Reperfusão/tratamento farmacológico , Traumatismo por Reperfusão/patologia , Administração por Inalação , Administração Intravenosa , Animais , Animais Recém-Nascidos , Aorta Abdominal/cirurgia , Constrição , Quimioterapia Combinada , Rim/irrigação sanguínea , Rim/patologia , Distribuição Aleatória , Traumatismo por Reperfusão/fisiopatologia , Suínos , Resultado do Tratamento
9.
F1000Res ; 6: 756, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28649372

RESUMO

Various forms of high-frequency ventilation (HFV) have been described. HFV is broadly defined as artificial ventilation of the lungs with sub-deadspace tidal volumes delivered using supra-physiological frequencies. HFV has been used in anaesthesia and intensive care for special procedures and conditions since the 1960s. Clinical interest in the use and the technical evolution of HFV has developed over time. There is a renewed interest in HFV for avoiding parenchymal movement during stereotactic tumour ablation. The present paper aims to give an overview of the fundamental physiology, technical aspects, and clinical challenges of HFV in ablation procedures during general anaesthesia, where HFV is used to minimise the movements of the ablation target.

10.
AJR Am J Roentgenol ; 208(1): 193-200, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27762601

RESUMO

OBJECTIVE: The purpose of the present study is to evaluate the accuracy and safety of antenna placement performed with the use of a CT-guided stereotactic navigation system for percutaneous ablation of liver tumors and to assess the safety of high-frequency jet ventilation for target motion control. MATERIALS AND METHODS: Twenty consecutive patients with malignant liver lesions for which surgical resection was contraindicated or that were not readily visible on ultrasound or not accessible by ultrasound guidance were included in the study. Patients were treated with percutaneous microwave ablation performed using a CT-guided stereotactic navigation system. High-frequency jet ventilation was used to reduce liver motion during all interventions. The accuracy of antenna placement, the number of needle readjustments required, overall safety, and the radiation doses were assessed. RESULTS: Microwave ablation was completed for 20 patients (28 lesions). Performance data could be evaluated for 17 patients with 25 lesions (mean [± SD] lesion diameter, 14.9 ± 5.9 mm; mean lesion location depth, 87.5 ± 27.3 mm). The antennae were placed with a mean lateral error of 4.0 ± 2.5 mm, a depth error of 3.4 ± 3.2 mm, and a total error of 5.8 ± 3.2 mm in relation to the intended target. The median number of antenna readjustments required was zero (range, 0-1 adjustment). No major complications were related to either the procedure or the use of high-frequency jet ventilation. The mean total patient radiation dose was 957.5 ± 556.5 mGy × cm, but medical personnel were not exposed to irradiation. CONCLUSION: Percutaneous microwave ablation performed with CT-guided stereotactic navigation provides sufficient accuracy and requires almost no repositioning of the needle. Therefore, it is technically feasible and applicable for safe treatments.


Assuntos
Ablação por Cateter/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Técnicas Estereotáxicas , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Viabilidade , Feminino , Hepatectomia/métodos , Ventilação em Jatos de Alta Frequência/métodos , Humanos , Masculino , Micro-Ondas/uso terapêutico , Segurança do Paciente , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Intensificação de Imagem Radiográfica/métodos , Resultado do Tratamento
11.
Case Rep Oncol ; 9(2): 400-404, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27721758

RESUMO

This is a case report of microwave energy being used to ablate an inoperable metastasis of a Wilms' tumour in a 6-year-old boy using state-of-the-art navigated computed tomography targeting and high-frequency jet ventilation to reduce organ displacement and the potential risk of procedure-related pneumothorax. After the ablation, the young boy had high-dose chemotherapy followed by an autologous stem cell transplantation with rapid reduction of three recurrent right-sided lung metastases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA