Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39189765

RESUMO

BACKGROUND AND OBJECTIVES: As advancements in cancer treatments have allowed patients with a high burden of disease to live longer, the number of patients who present with debilitating refractory pain has increased. Anterolateral cordotomy has long been used for the treatment of intractable unilateral cancer pain using either an imaging-guided percutaneous approach or an open surgical approach. In this report, we describe a novel minimally invasive modification to the open surgical approach. It combines the benefits of both approaches by providing direct visualization for lesioning without the collateral tissue damage of an open approach. METHODS: This retrospective study evaluated medical records, operative reports, and imaging studies of patients who underwent a minimally invasive cordotomy at a single institute between 2018 and 2022. The surgical technique involved a microscope-assisted C2 hemilaminectomy using microtubular retractors followed by dural opening and anterolateral cordotomy under direct visualization and with intraoperative neurophysiological monitoring. RESULTS: Eleven patients were included in the study. None were converted to an open approach, and no wound-related postoperative complications were observed. A clinically significant decrease in pain was observed after the procedure, and 10 of the 11 patients (91%) were ambulatory by the time of analysis. CONCLUSION: Compared with image-guided percutaneous cordotomy, anterolateral cervical cordotomy with microtubular retractors potentially improves the safety of the procedure through direct visualization while being less invasive than a conventional open approach. Our preliminary experience with this technique demonstrates the feasibility of the approach, as it was both safe and effective.

2.
J Orthop Surg Res ; 18(1): 364, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37194059

RESUMO

BACKGROUND: Anterior cervical corpectomy and fusion (ACCF) is an effective technique to address multi-level degenerative cervical myelopathy. However, as the number of surgical levels increases, the outcomes worsen with respect to complication rates, range of motion and length of surgery. This study aimed to determine the clinical outcome of ACCF procedures performed using a new distally curved and shielded drilling device. METHODS: A retrospective study was conducted on 43 ACCF procedures in which the device was used for osteophyte removal. Patient files were reviewed to assess the early clinical results and complications following ACCF. Clinical outcomes were evaluated using patient neck and arm pain scores and SF-36 questionnaires. Hospitalization characteristics were compared with historical controls. RESULTS: All procedures were uneventful and without major complications or neurological deterioration. Single-level ACCF procedures required an average of 71 min and followed by an average hospitalization of 3.3 days. Osteophyte removal, verified by intraoperative imaging, was satisfactory. Average neck pain score was improved by 0.9 points (p = 0.24). Average arm pain score was improved by 1.8 points (p = 0.06). SF-36 scores were improved in all domains. CONCLUSIONS: The new curved device enabled safe and efficient removal of osteophytes sparing adjacent vertebral removal in ACCF procedures, thus improving the clinical outcome.


Assuntos
Osteófito , Fusão Vertebral , Espondilose , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Espondilose/diagnóstico por imagem , Espondilose/cirurgia , Espondilose/complicações , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Discotomia/efeitos adversos , Discotomia/métodos , Cervicalgia/etiologia , Cervicalgia/cirurgia , Fusão Vertebral/métodos
3.
J Clin Med ; 12(2)2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36675466

RESUMO

Minimization of the surgical approaches to spinal extradural metastases resection and stabilization was advocated by the 2012 Oncological Guidelines for Spinal Metastases Management. Minimally invasive approaches to spine oncology surgery (MISS) are continually advancing. This paper will describe the evolution of minimally invasive surgical techniques for the resection of metastatic spinal lesions and stabilization in a single institute. A retrospective analysis of patients who underwent minimally invasive extradural spinal metastases resection during the years 2013-2019 by a single surgeon was performed. Medical records, imaging studies, operative reports, rates of screw misplacement, operative time and estimated blood loss were reviewed. Detailed description of the surgical technique is provided. Of 138 patients operated for extradural spinal tumors during the study years, 19 patients were treated in a minimally invasive approach and met the inclusion criteria for this study. The mortality rate was significantly improved over the years with accordance of improve selection criteria to better prognosis patients. The surgical technique has evolved over the study years from fluoroscopy to intraoperative 3D imaging and navigation guidance and from k-wire screw insertion technique to one-step screws. Minimally invasive spinal tumor surgery is an evolving technique. The adoption of assistive devices such as intraoperative 3D imaging and one-step screw insertion systems was safe and efficient. Oncologic patients may particularly benefit from the minimization of surgical decompression and fusion in light of the frailty of this population and the mitigated postoperative outcomes associated with MIS oncological procedures.

4.
J Neurol Surg A Cent Eur Neurosurg ; 84(5): 498-505, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35453164

RESUMO

BACKGROUND: Ventral thoracic meningiomas may pose a technical challenge owing to a limited surgical corridor and the presence of long-standing ventral cord compression. Unopposed dorsal spinal cord migration may occur following a laminectomy resulting in immediate neurologic injury. We discuss the possible mechanism underlying such a phenomenon, suggesting alternative approach to prevent neurologic injury. METHODS: Two patients operated on for ventral thoracic meningioma and sustained neurologic compromise were retrospectively evaluated. Image editing software was used for 3D modeling to simulate the possible underlying mechanism of injury. Cases where ventral thoracic meningiomas were approached via unilateral hemilaminectomy, performed in 2020, were retrospectively analyzed and compared with the laminectomy approach cohort. RESULTS: Two patients sustained postoperative neurologic function decline following resection of ventral thoracic meningioma via the laminectomy approach. Both exhibited permanent abolishment of transcranial motor evoked potentials (MEPs) following laminectomy. Based on the extrapolated 3D models for these two cases, dorsal cord migration was postulated as the cause for the acute neurologic compromise. CONCLUSION: Laminectomy for resection of thoracic ventral meningioma may lead in some cases to dorsal cord migration resulting in grave neurologic deterioration. Unilateral approach to these tumors restricts the dorsal migration and may mitigate neurologic outcomes.


Assuntos
Neoplasias Meníngeas , Meningioma , Humanos , Meningioma/cirurgia , Laminectomia/efeitos adversos , Laminectomia/métodos , Estudos Retrospectivos , Neoplasias Meníngeas/cirurgia , Imageamento por Ressonância Magnética
5.
Br J Neurosurg ; 37(6): 1624-1627, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35341430

RESUMO

PURPOSE: The upper cervical spine region is densely populated by neural and vascular structures impeding the approach for fusion surgery. Technological advancement simplify the approach to C1-C2 fusion, thus reduce risks. The current paper purpose is to describe initial experience with a novel technique modification for C1 lateral screw insertion that incorporates cannulated-navigated screw system with intra-operative 3D imaging. METHODS: A single-center single surgeon database was reviewed to identify all patients who underwent placement of C1 lateral mass screw insertion using the novel technique modification described below, on 2020. This cohort was retrospectively analyzed and compared with a cohort of patients who were operated on by the same surgeon with non-cannulated, navigated screws with intra-operative 3D imaging (O-arm, Medtronic, USA) between 2011 and 2019. Following navigated starting hole and drilling of the C1 lateral mass, a blunt guide-wire is used to palpate the hole and cannulated screw is advanced to the correct position over the wire. After initial purchase, a navigated screw driver is used for final screw depth position. RESULTS: Twelve C1 lateral mass screws were inserted in six patients using this novel cannulated-navigated screw placement technique and compared to 24 patients operated using navigated non-cannulated screws. Minimal Estimated Blood Loss (EBL) was recorded in five of six cases undergoing the novel cannulated navigated placement of C1 lateral mass screws. Comparison to non-cannulated cohort demonstrated an EBL of 83CC vs. 354CC (Not significant). Mean surgery time was 97min and 118min for the cannulated-navigated and navigated only procedures (p = 0.03, statistically significant) respectively. In the current cohort, all screws were rated in optimal position and no repositioning procedures were performed. CONCLUSION: The new method presented allows for faster and possibly safer and more accurate C1 lateral mass screw insertion.


Assuntos
Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X , Fusão Vertebral/métodos , Parafusos Ósseos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia
6.
Br J Neurosurg ; 37(1): 86-89, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35943396

RESUMO

OBJECTIVE: To ameliorate the clinical decision-making process when debating between a ventral or dorsal cervical approach by elucidating whether post-operative dysphagia be regarded as a complication or a transient side effect. METHODS: A literature review of studies comparing complication rates following ventral and dorsal cervical approaches was performed. A stratified complication rate excluding dysphagia was calculated and discussed. A retrospective cohort of patients operated for degenerative cervical myelopathy in a single institution comprising 665 patients was utilized to analyze complication rates using a uniform definition for dysphagia. RESULTS: Both the ventral and the dorsal approach groups exhibited comparable neurological improvement rates. Since transient dysphagia was not considered a complication, the dorsal approach was associated with higher level of overall complications. CONCLUSIONS AND RELEVANCE: Inconsistencies in the definition of dysphagia following ventral cervical surgery impedes the interpretation of trials comparing dorsal and ventral complication rates. A uniform definition for complications and side effects may enhance the validity of medical trials.


Assuntos
Transtornos de Deglutição , Fusão Vertebral , Humanos , Estudos Retrospectivos , Vértebras Cervicais/cirurgia , Discotomia/efeitos adversos , Fusão Vertebral/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/cirurgia , Resultado do Tratamento
7.
Neurosurg Focus ; 53(5): E10, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36321290

RESUMO

OBJECTIVE: Stereotactic body radiotherapy (SBRT) is a precise and conformal treatment modality used in the management of metastatic spine tumors. Multiple studies have demonstrated its safety and efficacy for pain and tumor control. However, no uniform quantitative imaging methodology exists to evaluate response to treatment in these patients. This study presents radiographic local control rates post-SBRT, systematically compares measurements acquired according to WHO and Response Evaluation Criteria in Solid Tumors (RECIST) criteria, and explores the relationship to patient outcome. METHODS: The authors performed a retrospective review of prospectively obtained data from a cohort of 59 consecutive patients (81 metastatic isocenters) treated with SBRT and followed with serial MRI scans. Measurements were performed by a neuroradiologist blinded to the patients' clinical course. Local control status was determined according to both WHO and RECIST measurements, and agreement between the measuring methodologies was calculated and reported. RESULTS: Eighty-one isocenters (111 vertebral bodies) were treated with SBRT. The mean treatment dose was 13.96 Gy and the median follow-up duration was 10.8 months, during which 408 MRI scans were evaluated with both WHO and RECIST criteria for each scan point. Imaging demonstrated a mean unidimensional size decrease of 0.2 cm (p = 0.14) and a mean area size decrease of 0.99 cm2 (p = 0.03). Although 88% of the case classifications were concordant and the agreement was significant, WHO criteria were found to be more sensitive to tumor size change. The local control rates according to WHO and RECIST were 95% and 98%, respectively. CONCLUSIONS: Although WHO volumetric measurements are admittedly superior for tumor size measurement, RECIST is simpler, reproducible, and for the first time is shown here to be comparable to WHO criteria. Thus, the application of RECIST methodology appears to be a suitable standard for evaluating post-SBRT treatment response. Moreover, using comprehensive and consistent measuring approaches, this study substantiates the efficacy of SBRT in the treatment of spine metastases.


Assuntos
Radiocirurgia , Neoplasias da Coluna Vertebral , Humanos , Radiocirurgia/métodos , Neoplasias da Coluna Vertebral/cirurgia , Resultado do Tratamento , Coluna Vertebral/patologia , Estudos Retrospectivos
8.
Neurol Neurochir Pol ; 56(5): 404-409, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35801653

RESUMO

INTRODUCTION: Degenerative cervical myelopathy (DCM) is a common condition often treated by surgical decompression and fusion. The objective of this paper was to compare short-term post-operative complication rates of patients with multi-level DCM treated with decompression and fusion using either an anterior or a posterior cervical approach. MATERIAL AND METHODS: A retrospective evaluation of patients' charts, imaging studies and operative reports of patients operated for multilevel subaxial DCM from 2011 to 2016 at a single institution was performed. Patients who were operated upon for the treatment of three stenosed spinal levels or above and who underwent anterior cervical discectomy and fusion, or anterior cervical corpectomy and fusion, or posterior cervical laminectomy and fusion, were included. Short-term post-operative complications were compared between the anterior and posterior approaches. RESULTS: Overall, 207 patients were included in this study. 156 were operated via an anterior approach and 51 via a posterior approach. The mean number of treated levels was 3.4 and 4.3 for the anterior and posterior approach groups, respectively (p < 0.001). In the posterior approach group, the proportion of stenosed spinal levels within all operated levels was significantly lower than in the anterior approach group (p = 0.025). Early post-operative neurological status change was favourable for both groups. Deep wound infection rate was significantly higher in the posterior approach group (7.8% vs. none; p = 0.001). CONCLUSIONS: Posterior cervical laminectomy and fusion is significantly associated with an increased rate of deep wound infection and wound revision surgery compared to the anterior approach. We recommend the anterior approach as the valid option in treating multi-level DCM.


Assuntos
Doenças da Medula Espinal , Fusão Vertebral , Infecção dos Ferimentos , Humanos , Vértebras Cervicais/cirurgia , Estudos Retrospectivos , Fusão Vertebral/métodos , Resultado do Tratamento , Descompressão Cirúrgica/métodos , Laminectomia/métodos , Complicações Pós-Operatórias/cirurgia , Infecção dos Ferimentos/cirurgia
9.
World Neurosurg ; 164: e1226-e1232, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35671991

RESUMO

OBJECTIVE: This pilot study was undertaken to evaluate the safety, performance, and usability of the Xvision-Spine (XVS) System (Augmedics, Arlington Heights, IL) during open spinal fixation procedures in patients requiring pedicle screw placement in the lumbosacral spine. METHODS: The XVS System is an augmented reality head-mounted display (HMD) based on a computer navigation system designed to assist surgeons in accurately placing pedicle screws. It uses an HMD-mounted tracking camera to provide optical tracking technology, and provides the surgeon a translucent direct near-eye display of the navigated surgical instrument's location relative to the computed tomographic image. We report the preliminary results of a prospective series of all consecutive patients who underwent augmented reality-assisted pedicle screw placement in the lumbosacral vertebrae at 3 institutions. Clinical accuracy for each pedicle screw was graded with Gertzbein-Robbins scores by 2 independent and blinded neuroradiologists. RESULTS: The 19 study participants included 8 men and 11 women with a mean age of 59.13 ± 12.09 and 59.91 ± 12.89 years, respectively. Seventeen procedures were successfully completed via the XVS System. Two procedures were not completed due to technical issues with the system's intraoperative scanner. A total of 86 screws were inserted. The accuracy of the XVS System was 97.7%. CONCLUSIONS: The XVS System's performance in accurate placement of pedicle screws in the lumbosacral vertebrae had an overall accuracy of 97.7%. These preliminary results were comparable to the accuracy of other manual computer-assisted navigation systems reported in the literature.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Idoso , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos
10.
World Neurosurg ; 164: e1-e7, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34332151

RESUMO

BACKGROUND: A definitive diagnosis of brain lesions not amenable to surgery is mainly made by stereotactic needle biopsy. The diagnostic yield and safety of the frameless versus frame-based image-guided stereotactic techniques is unclear. Our objective was to evaluate the safety and accuracy of frameless versus frame-based stereotactic brain biopsy techniques. METHODS: A total of 278 patients (153 men; mean age: 65.5 years) with intra-axial brain lesions underwent frame-based (n = 148) or frameless image-guided stereotactic brain biopsy (n = 130) using a minimally invasive twist drill technique during 2010-2016 at Sheba Medical Center. Demographic, imaging, and clinical data were retrospectively analyzed. RESULTS: The diagnostic yield (>90%) did not differ significantly between groups. Overall morbidity (6.8% vs. 8.5%), incidence of permanent neurologic deficits (2.1% vs. 1.6%), mortality rate (0.7% vs. 0.8%), and postoperative computed tomography-detected asymptomatic (14.2% vs. 16.1%) and symptomatic (2.0% vs. 1.6%) bleeding also did not differ significantly between the frame-based and frameless cohorts, respectively. The diagnostic yield and complication rates related to the biopsy technique were not significantly associated with sex, age, entry angle to the skull and skull thickness, lesion location or depth, or radiologic characteristics. Diagnostic yield was significantly associated with the mean lesion volume. Smaller lesions were less diagnostic than larger lesions in both techniques (P = 0.043 frame-based and P = 0.048 frameless). CONCLUSIONS: The frameless biopsy technique is as efficient as the frame-based brain biopsy technique with a low complication rate. Lesion volume was the only predictive factor of diagnostic yield. The minimally invasive twist drill technique is safe and efficient.


Assuntos
Neoplasias Encefálicas , Neuronavegação , Idoso , Biópsia/efeitos adversos , Biópsia/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Encéfalo/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Humanos , Biópsia Guiada por Imagem , Masculino , Neuronavegação/métodos , Estudos Retrospectivos , Técnicas Estereotáxicas
11.
Neurosurg Focus ; 50(5): E21, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33932929

RESUMO

OBJECTIVE: The use of intraoperative neuromonitoring (IONM) has become an imperative adjunct to the resection of intramedullary spinal cord tumors (IMSCTs). While the diagnostic utility of IONM during the immediate postoperative period has been previously studied, its long-term diagnostic accuracy has seldom been thoroughly assessed. The aim of this study was to evaluate long-term variations in the diagnostic accuracy of transcranial motor evoked potentials (tcMEPs), somatosensory evoked potentials (SSEPs), and D-wave recordings during IMSCT excision. METHODS: The authors performed a retrospective evaluation of imaging studies, patient charts, operative reports, and IONM recordings of patients who were operated on for gross-total or subtotal resection of IMSCTs at a single institution between 2012 and 2018. Variations in the specificity, sensitivity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative functional outcome (McCormick Scale) were analyzed at postoperative day 1 (POD1), 6 weeks postoperatively (PO-6 weeks), and at the latest follow-up. RESULTS: Overall, 28 patients were included. The mean length of follow-up was 19 ± 23.4 months. Persistent motor attenuations occurred in 71.4% of the cohort. MEP was the most sensitive modality (78.6%, 87.5%, and 85.7% sensitivity at POD1, PO-6 weeks, and last follow-up, respectively). The specificity of the D-wave was the most consistent over time (100%, 83.35%, and 90% specificity at the aforementioned time points). The PPV of motor recordings decreased over time (58% vs 33% and 100% vs 0 for tcMEP and D-wave at POD1 and last follow-up, respectively), while their NPV consistently increased (67% vs 89% and 70% vs 100% for tcMEP and D-wave at POD1 and last follow-up, respectively). CONCLUSIONS: The diagnostic accuracy of IONM in the resection of IMSCTs varies during the postoperative period. The decrease in the PPV of motor recordings over time suggests that this method is more predictive of short-term rather than long-term neurological deficits. The increasing NPV of motor recordings indicates a higher diagnostic accuracy in the identification of patients who preserve neurological function, albeit with an increased proportion of false-negative alarms for the immediate postoperative period. These variations should be considered in the surgical decision-making process when weighing the risk of resection-associated neurological injury against the implications of incomplete tumor resection.


Assuntos
Monitorização Neurofisiológica Intraoperatória , Neoplasias da Medula Espinal , Potencial Evocado Motor , Potenciais Somatossensoriais Evocados , Humanos , Procedimentos Neurocirúrgicos , Estudos Retrospectivos , Neoplasias da Medula Espinal/diagnóstico , Neoplasias da Medula Espinal/cirurgia
12.
Proc Natl Acad Sci U S A ; 118(6)2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33526664

RESUMO

We studied correlated firing between motor thalamic and cortical cells in monkeys performing a delayed-response reaching task. Simultaneous recording of thalamocortical activity revealed that around movement onset, thalamic cells were positively correlated with cell activity in the primary motor cortex but negatively correlated with the activity of the premotor cortex. The differences in the correlation contrasted with the average neural responses, which were similar in all three areas. Neuronal correlations reveal functional cooperation and opposition between the motor thalamus and distinct motor cortical areas with specific roles in planning vs. performing movements. Thus, by enhancing and suppressing motor and premotor firing, the motor thalamus can facilitate the transition from a motor plan to execution.


Assuntos
Sincronização Cortical/fisiologia , Atividade Motora/fisiologia , Córtex Motor/fisiologia , Tálamo/fisiologia , Animais , Feminino , Macaca fascicularis , Neurônios/fisiologia , Análise e Desempenho de Tarefas
13.
Neurol Neurochir Pol ; 55(2): 202-211, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33559873

RESUMO

BACKGROUND: To determine the utility of an intraoperative magnetic resonance imaging (iMRI) system, the Polestar N30, for enhancing the resection control of non-enhancing intra-axial brain lesions. MATERIALS AND METHODS: Seventy-three patients (60 males [83.3%], mean age 37 years) with intra-axial brain lesions underwent resection at Sheba Medical Centre using the Polestar between February 2012 and the end of August 2018. Demographic and imaging data were retrospectively analysed. Thirty-five patients had a non-enhancing lesion (48%). RESULTS: Complete resection was planned for 60/73 cases after preoperative imaging. Complete resection was achieved in 59/60 (98.3%) cases. After iMRI, additional resection was performed in 24/73 (32.8%) cases, and complete resection was performed in 17/60 (28.8%) cases in which a complete resection was intended. In 6/13 (46%) patients for whom incomplete resection was intended, further resection was performed. The extent of resection was extended mainly for non-enhancing lesions: 16/35 (46%) as opposed to only 8/38 (21%) for enhancing lesions. Further resection was not significantly associated with sex, age, intended resection, recurrence, or affected side. Univariate analysis revealed non-eloquent area, intended complete resection, and enhancing lesions to be predictive factors for complete resection, and non-enhancing lesions and scan time to be predictive factors for an extended resection. Non-enhancement was the only independent factor for extended resection. CONCLUSIONS: The Polestar N30 is useful for evaluating residual non-enhancing intra-axial brain lesions and achieving maximal resection.


Assuntos
Neoplasias Encefálicas , Glioma , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Monitorização Intraoperatória , Recidiva Local de Neoplasia , Estudos Retrospectivos
14.
Br J Neurosurg ; 35(6): 753-756, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32522043

RESUMO

OBJECTIVE: To describe a novel technique modification and evaluate initial results of pedicle screw insertion in minimally invasive transforaminal lumbar interbody fusion (MITLIF), using self-drilling self-tapping one-step screws. PATIENTS AND METHODS: All patients who were operated for MITLIF using the one-step technique over the last 6 months period at a single institute, were retrospectively identified. The surgical technique is described and depicted. Outcome evaluation was performed, including screw misplacement, screw insertion time, and post-operative complications. RESULTS: We describe a novel technique modification in which self-drilling self-tapping navigated screws incorporate an embedded K-wire that enables a one-step insertion which obviates the need for instrument exchange. The first four patients in whom this technique was implemented were included (mean age was 55). All patients had been previously operated at the fused level. The mean surgical duration was 142 minutes and the calculated mean screw insertion time was 8.2 minutes. The mean estimated blood loss was 66 cc. An intraoperative 3D scan demonstrated no screw pedicle breach. There were no neurological complications or wound healing disturbances. The clinical course was uneventful for all patients. CONCLUSION: To our knowledge, the use of one-step navigation-assisted self-drilling self-tapping pedicle screws with an embedded K-wire has not been previously described. Our initial experience with this novel technique modification was efficient and safe. Navigated surgery allows for newer and safer techniques to be incorporated into the surgeon's toolbox. Further studies should be performed to thoroughly evaluate this technique.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Vértebras Lombares/cirurgia , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Retrospectivos , Resultado do Tratamento
15.
World Neurosurg ; 147: e354-e362, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33346051

RESUMO

BACKGROUND: Spinal dural arteriovenous fistulas (SDAVFs) are rare vascular malformations. Digital subtraction angiography is the modality of choice to demonstrate the malformation before endovascular embolization or open surgical repair. Angiographically occult SDAVFs have been previously reported. Surgical considerations in SDAVFs with misleading angiography findings have not yet been assessed. METHODS: A retrospective evaluation of charts and imaging files of patients operated on for SDAVF in 2018-2019 at a single institution was performed. All patients were referred to surgery following failure of endovascular embolization or owing to clinical and radiographic deterioration in the presence of an angiographically occult lesion. Cases were comprehensively reviewed and evaluated for surgical considerations in these lesions. RESULTS: This case series included 4 cases. Two patients underwent embolization before surgical repair but continued to deteriorate neurologically, and 2 patients had a failed embolization attempt owing to a torturous vascular network. In all 4 patients, exploration was successful, yielding either improvement or stabilization of neurological status. Indocyanine green injection for microscopically integrated fluorescent angiography contributed to the identification of the supplying vessels and confirmed the SDAVF closure. CONCLUSIONS: SDAVFs should be treated promptly after diagnosis. In cases with high suspicion for SDAVF with occult or misleading angiography findings, spinal exploration should be pursued with no delay. Indocyanine green-assisted microscopic angiography may contribute to exploratory spine surgery for SDAVF closure.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/cirurgia , Medula Espinal/cirurgia , Coluna Vertebral/cirurgia , Falha de Tratamento , Idoso , Angiografia Digital/métodos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
16.
Global Spine J ; 10(8): 1022-1026, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32875823

RESUMO

STUDY DESIGN: Retrospective cohort study. OBJECTIVES: The learning curve associated with the implementation of minimally invasive spinal surgery (MIS) has been the center of attention in numerous publications. So far, these studies referred to a single MIS procedure. In our view, minimally invasive surgical skills are acquired simultaneously through a variety of procedures that share common features. The aim of this study was to analyze the skills progression of a single surgeon implementing diverse minimally invasive techniques. METHODS: We retrospectively collected all patients who underwent spinal surgery for thoracic or lumbar pathology by a single surgeon between 2012 and 2015 at a single institute. Both minimally invasive as well as open surgical techniques were analyzed; these groups were compared on the basis of surgical indications and outcomes. Skills progression analysis in reference to minimally invasive technique was performed. RESULTS: A total of 230 patients met the inclusion criteria for this study. MIS group included higher percentage of lumbar discectomy and the open-surgery group included higher percentage of tumor resection surgery. Learning curve evaluation demonstrated increased surgical complexity, evaluated by number of levels treated, over the 4-year period, which corresponded with decreased complication rates. DISCUSSION: A gradual increase in surgical complexity over 4 years, together with careful patient selection, enables the surgeon to maintain the rate of complication within acceptable limits. The main challenge facing the MIS community is constructing an education program for MIS surgeons in order to reduce the learning curve-induced complications. CONCLUSION: Advancement of educational aids for MIS surgical skill improvement, including spine models, virtual and augmented reality aids and surgical simulators may reduce the learning curve of spine surgeons.

17.
Neurol India ; 67(6): 1431-1436, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31857529

RESUMO

AIMS AND OBJECTIVES: To review a series of patients with brain metastases from ovarian cancer at a single institution. To describe treatment modalities, their outcomes and to determine prognostic factors. PATIENTS AND METHODS: Between January 1995 and December 2014, 25 patients with ovarian cancer brain metastases were treated at The Sheba Medical Center. The medical records were retrospectively reviewed to collect demographic, clinical, and imaging data as well as the information on the treatment modalities used and their outcomes. RESULTS: Mean patient age at the time of brain metastasis diagnosis was 62.7 years. The median interval between the diagnosis of primary cancer and brain metastasis was 42.3 months. Neurologic deficits, headache, and seizure were the most common symptoms. The brain was the only site of metastasis in 20% of the patients. Active ovarian cancer at the time of diagnosis of brain metastasis was observed in half of the patients with systemic disease. Multiple brain metastases were observed in 25% of the patients. We treated 11 patients with surgery plus radiation therapy protocols in various orders: surgery followed by complementary whole-brain radiation therapy (WBRT), surgery followed by stereotactic radiosurgery (SRS), and surgery followed by WBRT and then by adjuvant SRS. Five patients underwent surgery alone and nine patients were treated with radiation alone (WBRT, SRS, or both). Univariate analysis for predictors of survival demonstrated that age above 62.7 years at the time of central nervous system involvement was a significant risk factor and leptomeningeal disease was a poor prognostic factor in reference to supra-tentorial lesions. Multivariate analysis for predictors of survival, however, showed that multiple brain lesions (>4) were a poor prognostic factor, and multivariate analysis of the time to progression revealed that combined treatments of surgery and radiation resulted in longer median periods of progression-free survival than each modality alone. CONCLUSION: We conclude that the only significant predictors of survival or progression-free survival in our cohort were the number of brain metastases and the treatment modality.


Assuntos
Neoplasias Encefálicas/secundário , Irradiação Craniana , Cistadenocarcinoma Seroso/secundário , Procedimentos Neurocirúrgicos , Neoplasias Ovarianas/patologia , Idoso , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/terapia , Terapia Combinada , Cistadenocarcinoma Seroso/mortalidade , Cistadenocarcinoma Seroso/terapia , Bases de Dados Factuais , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/mortalidade , Neoplasias Ovarianas/terapia , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
18.
J Neurosurg Spine ; : 1-8, 2019 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-30925479

RESUMO

OBJECTIVE Augmented reality (AR) is a novel technology that has the potential to increase the technical feasibility, accuracy, and safety of conventional manual and robotic computer-navigated pedicle insertion methods. Visual data are directly projected to the operator's retina and overlaid onto the surgical field, thereby removing the requirement to shift attention to a remote display. The objective of this study was to assess the comparative accuracy of AR-assisted pedicle screw insertion in comparison to conventional pedicle screw insertion methods. METHODS Five cadaveric male torsos were instrumented bilaterally from T6 to L5 for a total of 120 inserted pedicle screws. Postprocedural CT scans were obtained, and screw insertion accuracy was graded by 2 independent neuroradiologists using both the Gertzbein scale (GS) and a combination of that scale and the Heary classification, referred to in this paper as the Heary-Gertzbein scale (HGS). Non-inferiority analysis was performed, comparing the accuracy to freehand, manual computer-navigated, and robotics-assisted computer-navigated insertion accuracy rates reported in the literature. User experience analysis was conducted via a user experience questionnaire filled out by operators after the procedures. RESULTS The overall screw placement accuracy achieved with the AR system was 96.7% based on the HGS and 94.6% based on the GS. Insertion accuracy was non-inferior to accuracy reported for manual computer-navigated pedicle insertion based on both the GS and the HGS scores. When compared to accuracy reported for robotics-assisted computer-navigated insertion, accuracy achieved with the AR system was found to be non-inferior when assessed with the GS, but superior when assessed with the HGS. Last, accuracy results achieved with the AR system were found to be superior to results obtained with freehand insertion based on both the HGS and the GS scores. Accuracy results were not found to be inferior in any comparison. User experience analysis yielded "excellent" usability classification. CONCLUSIONS AR-assisted pedicle screw insertion is a technically feasible and accurate insertion method.

19.
Br J Neurosurg ; 32(6): 599-603, 2018 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-29745733

RESUMO

PURPOSE: Application of the anterior sub-axial cervical approach to the axial spine or the high thoracic spine has been previously described. Evaluation methods to determine the feasibility of these approaches were also described but alternative method was utilized in the current study. We describe our experience expanding the boundaries of anterior cervical approach utilizing a novel algorithm for approach selection. MATERIALS AND METHODS: A retrospective analysis of patients' files and imaging data of all anterior cervical approach to treat pathologies above C2-3 disc space or below C7-D1 disc space. The decision to proceed with standard approach was based on CT or MRI scans and the pre-operative cervical range of motion. Post-operative course and surgical complications will be discussed. RESULTS: During a two year period 13 patients had undergone anterior cervical approach to the axial spine (3 patients) or the thoracic spine (10 patients). Ten patients were treated for tumour resection, one for trauma, one for myelopathy and the last for infective osteomyelitis with epidural abscess. Three patients were previously operated in another hospital via the posterior approach with remaining compressive mass necessitating anterior decompression. Complications were recorded in 30% of the patients. CONCLUSIONS: Approach to the axial or the high thoracic spine is more challenging and harbors approach-related complication. Pre-operative evaluation of patients imaging allows harnessing the standard approach for treatment of extreme levels with relative safety and efficiency. Spine surgeons' awareness to this technique may increase surgical efficacy while reducing the complication rates.

20.
Cell Rep ; 23(5): 1275-1285, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29719244

RESUMO

In higher mammals, motor timing is considered to be dictated by cerebellar control of motor cortical activity, relayed through the cerebellar-thalamo-cortical (CTC) system. Nonetheless, the way cerebellar information is integrated with motor cortical commands and affects their temporal properties remains unclear. To address this issue, we activated the CTC system in primates and found that it efficiently recruits motor cortical cells; however, the cortical response was dominated by prolonged inhibition that imposed a directional activation across the motor cortex. During task performance, cortical cells that integrated CTC information fired synchronous bursts at movement onset. These cells expressed a stronger correlation with reaction time than non-CTC cells. Thus, the excitation-inhibition interplay triggered by the CTC system facilitates transient recruitment of a cortical subnetwork at movement onset. The CTC system may shape neural firing to produce the required profile to initiate movements and thus plays a pivotal role in timing motor actions.


Assuntos
Atividade Motora/fisiologia , Córtex Motor , Rede Nervosa , Transmissão Sináptica/fisiologia , Animais , Feminino , Macaca fascicularis , Masculino , Córtex Motor/citologia , Córtex Motor/fisiologia , Rede Nervosa/citologia , Rede Nervosa/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA