Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38555029

RESUMO

Obesity and overweight affect almost one third of the European population. Obesity and its associated conditions, including type 2 diabetes, significantly impact healthcare systems, life expectancy and quality of life. The emergence of glucagon-like peptide-1 (GLP-1) receptor agonists for the treatment of obesity, with or without diabetes, has provided an effective alternative to metabolic surgery and dietary interventions. We are now beginning to understand their pleiotropic effects beyond weight loss, such as their favourable impact on cardiovascular profiles. The aim of this review is to summarize available preclinical and clinical data on the beneficial effects of GLP-1 receptor agonists on atherosclerosis and cardiovascular disease which has the potential to substantially broaden the scope of their clinical applications.

2.
J Clin Med ; 13(2)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38276098

RESUMO

Transcatheter aortic valve implantation (TAVI) is now well established as the treatment of choice for patients with native aortic valve stenosis who are high or intermediate risk for surgical aortic valve replacement. Recent data has also supported the use of TAVI in patients at low surgical risk and also in anatomical subsets that were previously felt to be contra-indicated including bicuspid aortic valves and aortic regurgitation. With advancements and refinements in procedural techniques, the application of this technology has now been further expanded to include the management of degenerated bioprosthesis. After the demonstration of feasibility and safety in the management of degenerated aortic bioprosthetic valves, mitral and tricuspid bioprosthetic valve treatment is now also well-established and provides an attractive alternative to performing redo surgery. In this review, we appraise the latest clinical evidence and highlight procedural considerations when utilising TAVI technology in the management of degenerated aortic, mitral or tricuspid prosthesis.

3.
Antioxidants (Basel) ; 11(2)2022 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-35204154

RESUMO

We aimed to investigate if major vascular surgery induces LDL oxidation, and whether circulating antibodies against malondialdehyde-modified LDL (MDA-LDL) alter dynamically in this setting. We also questioned relationships between these biomarkers and post-operative cardiovascular events. Major surgery can induce an oxidative stress response. However, the role of the humoral immune system in clearance of oxidized LDL following such an insult is unknown. Plasma samples were obtained from a prospective cohort of 131 patients undergoing major non-cardiac vascular surgery, with samples obtained preoperatively and at 24- and 72 h postoperatively. Enzyme-linked immunoassays were developed to assess MDA-LDL-related antibodies and complexes. Adverse events were myocardial infarction (primary outcome), and a composite of unstable angina, stroke and all-cause mortality (secondary outcome). MDA-LDL significantly increased at 24 h post-operatively (p < 0.0001). Conversely, levels of IgG and IgM anti-MDA-LDL, as well as IgG/IgM-MDA-LDL complexes and total IgG/IgM, were significantly lower at 24 h (each p < 0.0001). A smaller decrease in IgG anti-MDA-LDL related to combined clinical adverse events in a post hoc analysis, withstanding adjustment for age, sex, and total IgG (OR 0.13, 95% CI [0.03-0.5], p < 0.001; p value for trend <0.001). Major vascular surgery resulted in an increase in plasma MDA-LDL, in parallel with a decrease in antibody/complex levels, likely due to antibody binding and subsequent removal from the circulation. Our study provides novel insight into the role of the immune system during the oxidative stress of major surgery, and suggests a homeostatic clearance role for IgG antibodies, with greater reduction relating to downstream adverse events.

4.
Antioxidants (Basel) ; 10(8)2021 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-34439546

RESUMO

Oxidized low-density lipoproteins play an important role in tissue pathology. In this study, we report a sensitive novel enzyme-linked immunosorbent assay for the detection of malondialdehyde-modified low-density lipoprotein (MDA-LDL), a key component of oxidized LDL. The assay is capable of measuring a variable presence of MDA-LDL within human plasma and serum. We demonstrate the robust nature of the assay on samples stored for over 20 months, as well as high inter-operator reproducibility (r = 0.74, p < 0.0001). The assay was capable of detecting dynamic changes in patient blood samples after coronary artery bypass graft surgery, indicating synthesis or release of MDA-LDL with the oxidative stress of surgery, followed by homeostatic clearance. This robust, sensitive and specific assay for circulating MDA-LDL will serve as a valuable translational tool for the improved detection of oxidative forms of LDL in response to a range of physiological or pathological stimuli, with potential clinical applicability.

5.
Arq. bras. cardiol ; 115(6): 1154-1161, dez. 2020. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1152938

RESUMO

Resumo Fundamento Nos últimos anos, o recente aumento no número de procedimentos intervencionistas tem resultado em crescente preocupação em relação à exposição radiológica por pacientes e equipe médica. A avaliação da exposição dos níveis de radiação em crianças é difícil devido à grande variabilidade no peso corporal. Portanto, os valores de referência de radiação não estão bem definidos para essa população. Objetivos Avaliar e validar a razão do produto dose-área (DAP) em relação ao peso corporal como uma medida de referência de radiação em cateterismos cardíacos em crianças. Métodos Estudo multicêntrico observacional com dados do Registro Brasileiro de Cateterismo Cardíaco em Cardiopatias Congênitas (CHAIN) de março de 2013 a junho de 2014. Os critérios de inclusão foram: pacientes <18 anos submetidos a procedimentos hemodinâmicos para cardiopatia congênita, com DAP devidamente registrado. Foram considerados diferenças estatísticas significativas os valores de p < 0,05. Resultados Este estudo avaliou 429 pacientes com idade e peso medianos de 50 (10, 103) meses e 15 (7, 28) kg, respectivamente. O DAP mediano foi de 742,2 (288,8, 1.791,5) μGy.m2. Houve uma boa correlação entre o DAP e o produto peso/tempo de fluoroscopia (rs=0,66). Não foi observada diferença estatisticamente significativa na relação DAP/peso entre procedimentos terapêuticos e diagnósticos. Houve ampla variação da relação DAP/peso entre os procedimentos terapêuticos (p<0.001). Conclusões A proporção DAP/peso é a medida mais simples e aplicável para avaliar a exposição radiológica em uma população pediátrica. Apesar da escassa literatura disponível, as doses obtidas no presente estudo foram semelhantes àquelas encontradas anteriormente. Estudos de validação e comparação são importantes na avaliação do impacto de estratégias para redução da exposição radiológica nessa população. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background In recent years the increasing number of interventional procedures has resulted in growing concerns regarding radiation exposure for patients and staff. The evaluation of radiation exposure in children is difficult due to the great variability in body weight. Therefore, reference levels of radiation are not well defined for this population. Objectives To study and validate the ratio of dose-area product (DAP) to patient weight as a reference measurement of radiation for hemodynamic congenital heart disease procedures in children. Methods This observational multicenter study uses data obtained from a Brazilian registry of cardiac catheterization for congenital heart disease from March 2013 to June 2014. Inclusion criteria were all patients aged <18 years old undergoing hemodynamic procedures for congenital heart disease, with recorded DAP doses. P-value < 0.05 was considered as statistically significant. Results This study evaluated 429 patients with median age and weight of 50 (10, 103) months and 15 (7, 28) kg, respectively. Median DAP was 742.2 (288.8, 1,791.5) μGy.m2. There was a good correlation between DAP and weight-fluoroscopic time product(rs=0.66). No statistically significant difference was observed in DAP/weight ratio between therapeutic and diagnostic procedures. There was a wide variation in the DAP/weight ratio among the therapeutic procedures (p<0.001). Conclusions The DAP/weight ratio is the simplest and most applicable measurement to evaluate radiation exposure in a pediatric population. Although there is limited literature available, the doses obtained in the present study were similar to those previously found. Ongoing research is important to evaluate the impact of strategies to reduce radiation exposure in this population (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Assuntos
Humanos , Pré-Escolar , Criança , Adolescente , Idoso , Exposição à Radiação/efeitos adversos , Cardiopatias Congênitas , Doses de Radiação , Brasil , Fluoroscopia , Cateterismo Cardíaco/efeitos adversos , Radiografia Intervencionista , Sistema de Registros
6.
Arq Bras Cardiol ; 115(6): 1154-1161, 2020 12.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33084745

RESUMO

BACKGROUND: In recent years the increasing number of interventional procedures has resulted in growing concerns regarding radiation exposure for patients and staff. The evaluation of radiation exposure in children is difficult due to the great variability in body weight. Therefore, reference levels of radiation are not well defined for this population. OBJECTIVES: To study and validate the ratio of dose-area product (DAP) to patient weight as a reference measurement of radiation for hemodynamic congenital heart disease procedures in children. METHODS: This observational multicenter study uses data obtained from a Brazilian registry of cardiac catheterization for congenital heart disease from March 2013 to June 2014. Inclusion criteria were all patients aged <18 years old undergoing hemodynamic procedures for congenital heart disease, with recorded DAP doses. P-value < 0.05 was considered as statistically significant. RESULTS: This study evaluated 429 patients with median age and weight of 50 (10, 103) months and 15 (7, 28) kg, respectively. Median DAP was 742.2 (288.8, 1,791.5) µGy.m2. There was a good correlation between DAP and weight-fluoroscopic time product(rs=0.66). No statistically significant difference was observed in DAP/weight ratio between therapeutic and diagnostic procedures. There was a wide variation in the DAP/weight ratio among the therapeutic procedures (p<0.001). CONCLUSIONS: The DAP/weight ratio is the simplest and most applicable measurement to evaluate radiation exposure in a pediatric population. Although there is limited literature available, the doses obtained in the present study were similar to those previously found. Ongoing research is important to evaluate the impact of strategies to reduce radiation exposure in this population (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).


FUNDAMENTO: Nos últimos anos, o recente aumento no número de procedimentos intervencionistas tem resultado em crescente preocupação em relação à exposição radiológica por pacientes e equipe médica. A avaliação da exposição dos níveis de radiação em crianças é difícil devido à grande variabilidade no peso corporal. Portanto, os valores de referência de radiação não estão bem definidos para essa população. OBJETIVOS: Avaliar e validar a razão do produto dose-área (DAP) em relação ao peso corporal como uma medida de referência de radiação em cateterismos cardíacos em crianças. MÉTODOS: Estudo multicêntrico observacional com dados do Registro Brasileiro de Cateterismo Cardíaco em Cardiopatias Congênitas (CHAIN) de março de 2013 a junho de 2014. Os critérios de inclusão foram: pacientes <18 anos submetidos a procedimentos hemodinâmicos para cardiopatia congênita, com DAP devidamente registrado. Foram considerados diferenças estatísticas significativas os valores de p < 0,05. RESULTADOS: Este estudo avaliou 429 pacientes com idade e peso medianos de 50 (10, 103) meses e 15 (7, 28) kg, respectivamente. O DAP mediano foi de 742,2 (288,8, 1.791,5) µGy.m2. Houve uma boa correlação entre o DAP e o produto peso/tempo de fluoroscopia (rs=0,66). Não foi observada diferença estatisticamente significativa na relação DAP/peso entre procedimentos terapêuticos e diagnósticos. Houve ampla variação da relação DAP/peso entre os procedimentos terapêuticos (p<0.001). CONCLUSÕES: A proporção DAP/peso é a medida mais simples e aplicável para avaliar a exposição radiológica em uma população pediátrica. Apesar da escassa literatura disponível, as doses obtidas no presente estudo foram semelhantes àquelas encontradas anteriormente. Estudos de validação e comparação são importantes na avaliação do impacto de estratégias para redução da exposição radiológica nessa população. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).


Assuntos
Cardiopatias Congênitas , Exposição à Radiação , Adolescente , Idoso , Brasil , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Fluoroscopia , Humanos , Doses de Radiação , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA