Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Oper Neurosurg (Hagerstown) ; 19(6): E605, 2020 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-32678908

RESUMO

Minimally invasive surgery (MIS) approaches for the correction of adult spinal deformity have gained popularity in the past decade. MIS approaches can result in decreased hospitalization times and decreased morbidity. However, compared to open techniques, MIS approaches are challenging in the setting of fixed sagittal deformity and strategic surgical staging. Combined MIS and miniopen techniques are described as "hybrid" techniques. We report on the surgical approach for a fixed sagittal deformity using both MIS and miniopen techniques, specifically a miniopen pedicle subtraction osteotomy (PSO) and an anterior column release (ACR). The patient gave written informed consent for surgical treatment; institutional review board approval was not required. The patient first underwent the placement of percutaneous modular pedicle screws from T12 to the pelvis as well as a mini-PSO across the previously fused L5 vertebral body, with the placement of a temporary rod. The following day, the patient underwent lateral transpsoas interbody fusion and ACR at L2/3; a percutaneous rod was then passed from T12 to the pelvis for segmental fixation. The patient recovered well and was discharged home without complication 6 d after the initial day of surgery. The combined use of surgical staging and traditional open techniques in a selective, minimalistic fashion and adherence to minimally invasive principles provide for a powerful set of surgical techniques that capitalize on less invasive approaches to deformity management. Used with permission from Barrow Neurological Institute, Phoenix, Arizona.

2.
J Clin Neurosci ; 65: 145-147, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31040034

RESUMO

BACKGROUND AND IMPORTANCE: Minimally invasive transpsoas approach to treat lumbar spondylolisthesis is associated with increased clinical benefits. CLINICAL PRESENTATION: Robotic and navigation aided deformity correction for grade II spondylolisthesis was performed using transpsoas approach with pedicle screw placement in lateral decubitus position. CONCLUSION: Keeping the patient in the lateral decubitus position, we supplemented interbody cage placement with screws. Single position lateral transpsoas approach provides grade II spondylolisthesis improvement.


Assuntos
Vértebras Lombares/cirurgia , Robótica , Espondilolistese/cirurgia , Adulto , Idoso , Suplementos Nutricionais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos , Parafusos Pediculares , Fusão Vertebral
3.
Oper Neurosurg (Hagerstown) ; 17(4): 389-395, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30753599

RESUMO

BACKGROUND: Minimally invasive surgery (MIS) and anterior (ALIF), transforaminal (TLIF), or lateral lumbar interbody fusion (LLIF) often require percutaneous pedicle screw fixation (PSF) to achieve circumferential fusion. Robotic guidance technology may augment workflow to improve screw placement and decrease operative time. OBJECTIVE: To report surgical experience with robotically assisted percutaneous screw placement following LLIF. METHODS: Data from fusions with robotically assisted PSF in prone or lateral decubitus positions was reviewed. A CT-guided robotic guidance arm was used for screw placement (Excelsius GPS™, Globus Medical Inc, Audubon, Pennsylvania). Postoperative CT imaging facilitated screw localization. 3-dimensional and 2-dimensional coordinates of the screw tip and tail were calculated and compared with a target trajectory to calculate targeting errors. Breach was defined as a violation of the lateral or medial pedicle wall. RESULTS: Robotic-guided screw placement was successful in 28/31 patients. In those patients, 116/116 screws were successfully implanted. The breach rate was 3.4% (4/116). Across 17 patients (70 screws), mean 3-D accuracy was 5.0 ± 2.4 mm, mean 2-D accuracy was 2.6 ± 1.1 mm, and mean angular offset was 5.6 ± 4.3° with corresponding intraclass correlation coefficients (ICC) of 0.775 and 0.693. 3-dimensional accuracy correlated with age (R = 0.306, P = .011) and BMI (R = 0.252, P = .038). Accuracy did not significantly differ among vertebral body levels (P > .22). Mean operative time for MIS-TLIF and percutaneous screws was 277 ± 52 and 183 ± 54 min, respectively. Operative time did not significantly decrease across either group (P > .187). CONCLUSION: The Excelsius GPS™ robotic guidance system allows accurate PSF in most cases with 2 mm 2-D accuracy. Future studies are needed to demonstrate the utility of this novel guidance system and workflow improvement.


Assuntos
Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos/métodos , Fusão Vertebral/métodos , Espondilolistese/cirurgia , Idoso , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
4.
World Neurosurg ; 122: e1037-e1040, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30414525

RESUMO

BACKGROUND: A comparative evaluation of operative costs between single-level transforaminal interbody fusion (TLIF) and stand-alone lateral transpsoas interbody fusion (LIF) has not yet been done. We analyzed the costs, operative parameters, and early outcomes of single-level stand-alone LIF versus single-level TLIF. METHODS: Ten patients who underwent single-level TLIF and 10 patients who underwent single-level stand-alone LIF were included in the analysis. Total, variable, and fixed costs from perioperative data were available from a single institution. In addition, patient demographics, length of hospital stay, and 30-day outcomes and readmission rates were reviewed. RESULTS: Total cost, variable cost, and fixed costs were significantly lower in the LIF group, and there was no difference in outcomes. CONCLUSIONS: Single-level stand-alone LIF may prove to be more cost-effective and provide cost savings with analogous 30-day outcomes compared with single-level TLIF procedures.


Assuntos
Análise Custo-Benefício/tendências , Vértebras Lombares/cirurgia , Músculos Psoas/cirurgia , Fusão Vertebral/economia , Fusão Vertebral/tendências , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Degeneração do Disco Intervertebral/economia , Degeneração do Disco Intervertebral/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Projetos Piloto , Estudos Retrospectivos , Espondilolistese/economia , Espondilolistese/cirurgia , Fatores de Tempo , Resultado do Tratamento
5.
World Neurosurg ; 110: e636-e641, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29180081

RESUMO

BACKGROUND: In some fluoroscopy machines, the dose-rate output of the fluoroscope is tied to a selectable patient size. Although patient size may play a significant role in visceral or cardiac procedures, head morphology is less variable, and high dose outputs may not be necessary even in very obese patients. We hypothesized that very small patient size setting can be used to reduce dose for cerebral angiography without compromising image quality. METHODS: Patients who underwent endovascular neurosurgical procedures during the 2015-2016 academic year were identified, and estimated procedural air kerma (AK) was tabulated retrospectively. Technologists were instructed to begin using the very small patient size setting for all procedures performed using our Philips Allura Xper FD20 biplane fluoroscopy system beginning in March 2016. No changes were made in a second procedure room using a Toshiba Infinix system. Student t tests and logistic regression models were used to compare radiation exposure before and after March 1, 2016, for both machines. RESULTS: For diagnostic cerebral angiograms performed on the Philips system (n = 302), AK was reduced by approximately 17% (1277 vs. 1061 mGy; P = 0.0006.) Changes in table height, total fluoroscopy time, patient weight, and body mass index did not contribute to this difference. No significant change was seen in total AK using the Toshiba system (n = 237). Blinded review by a neuroradiologist did not demonstrate any change in image quality. CONCLUSIONS: Using the very small patient size reduces fluoroscopy dose by 17% for cerebral angiography without impacting image quality.


Assuntos
Peso Corporal , Angiografia Cerebral , Procedimentos Endovasculares , Fluoroscopia , Procedimentos Neurocirúrgicos , Cirurgia Assistida por Computador , Angiografia Cerebral/instrumentação , Angiografia Cerebral/métodos , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Humanos , Modelos Logísticos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos
6.
Proc Natl Acad Sci U S A ; 109(6): 2060-5, 2012 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-22308460

RESUMO

Studies of tumors from human familial adenomatous polyposis, sporadic colon cancer, and mouse and rat models of intestinal cancer indicate that the majority of early adenomas develop through loss of normal function of the Adenomatous polyposis coli (APC) gene. In murine models of familial adenomatous polyposis, specifically the multiple intestinal neoplasia mouse (Min) and the polyposis in the rat colon (Pirc) rat, most adenomas have lost their WT copy of the Apc gene through loss of heterozygosity by homologous somatic recombination. We report that large colonic adenomas in the Pirc rat have no detectable copy number losses or gains in genomic material and that most tumors lose heterozygosity only on the short arm of chromosome 18. Examination of early mouse and rat tumors indicates that a substantial subset of tumors shows maintenance of heterozygosity of Apc in genomic DNA, apparently violating Knudson's two-hit hypothesis. Sequencing of the Apc gene in a sampling of rat tumors failed to find secondary mutations in the majority of tumors that maintained heterozygosity of Apc in genomic DNA. Using quantitative allele-specific assays of Apc cDNA, we discovered two neoplastic pathways. One class of tumors maintains heterozygosity of Apc(Min/+) or Apc(Pirc/+) RNA expression and may involve haploinsufficiency for Apc function. Another class of tumors exhibits highly biased monoallelic expression of the mutant Apc allele, providing evidence for a stochastic or random process of monoallelic epigenetic silencing of the tumor suppressor gene Apc.


Assuntos
Alelos , Inativação Gênica , Haploinsuficiência/genética , Neoplasias Intestinais/genética , Processamento Alternativo/genética , Animais , Sequência de Bases , DNA Complementar/genética , Epigênese Genética , Dosagem de Genes/genética , Regulação Neoplásica da Expressão Gênica , Genes APC , Loci Gênicos/genética , Genoma/genética , Heterozigoto , Humanos , Imuno-Histoquímica , Neoplasias Intestinais/patologia , Camundongos , Camundongos Endogâmicos C57BL , Modelos Genéticos , Dados de Sequência Molecular , Mutação/genética , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Ratos , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA