Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Arthroplasty ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38972434

RESUMO

INTRODUCTION: In orthopaedic surgery, particularly total knee arthroplasty (TKA), the management of surgical wounds is critical for optimal wound healing and successful patient outcomes. Despite advances in surgical techniques, challenges persist in effectively managing surgical wounds to prevent complications and infections. This study aimed to identify and address the critical evidence gaps in wound management in TKA, including preoperative optimization, intraoperative options, and for the avoidance of postoperative complications. These are important issues surrounding wound management, which is essential for improving patient recovery and the overall success of the surgery. METHODS: Utilizing the Delphi method, this study brought together 20 experienced orthopaedic surgeons from Europe and North America. Conducted from April to September 2023, the process involved three stages: an initial electronic survey, a virtual meeting, and a concluding electronic survey. The panel reviewed and reached a consensus on 26 specific statements about wound management in TKA based on a comprehensive literature review. During these three stages and after further panel review, an alternative goal of the Delphi panel was to also identify critical evidence gaps in the current understanding of wound management practices for TKA. RESULTS: While the panel reached consensus on various wound management practices, they highlighted several major evidence gaps. Also, there was general consensus on issues such as wound closure methods including the use of mesh-adhesive dressings, skin glue, staples, sutures (including barbed sutures),and negative-pressure wound therapy (NPWT). However, it was deemed necessary that further evidence needs to be generated to address the cost-effectiveness of each and develop best practices for promoting patient outcomes. The identification of these gaps points to areas requiring more in-depth research and improvements to enhance wound care in TKA. DISCUSSION: The identification of these major evidence gaps underscores the need for targeted research in wound management surrounding TKA. Addressing these evidence gaps is crucial for the future development of more effective, efficient, and patient-friendly wound care strategies. Future research should prioritize these areas, focusing on comparative effectiveness studies and further developing clear guidelines for the use of emerging technologies. Bridging these gaps has the potential to improve patient outcomes, reduce complications, and elevate the overall success rate of TKA surgeries.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38829243

RESUMO

PURPOSE: Restricted inverse kinematic alignment (iKA) is a contemporary alignment strategy for total knee arthroplasty (TKA), commonly performed with robotic assistance. While superior clinical results are reported for kinematic-type alignment strategies, registry data indicate no survivorship benefit for navigation or robotic assistance. This study aimed to determine the efficacy of an instrumented, restricted iKA technique for achieving patient-specific alignment. METHODS: Seventy-nine patients undergoing 84 TKAs (five bilateral procedures) using an iKA technique were included for preoperative and postoperative lower limb alignment analysis. The mean age was 66.5 (range: 43-82) with 33 male and 51 female patients. Artificial intelligence was employed for radiographic measurements. Alignment profiles were classified using the Coronal Plane Alignment of the Knee (CPAK) system. Preoperative and postoperative alignment profiles were compared with subanalyses for preoperative valgus, neutral and varus profiles. RESULTS: The mean joint-line convergence angle (JLCA) reduced from 2.5° to -0.1° postoperatively. The mean lateral distal femoral angle (LDFA) remained unchanged postoperatively, while the mean medial proximal tibial angle (MPTA) increased by 2.5° (p = 0.001). By preservation of the LDFA and restoration of the MPTA, the mean hip knee ankle angle (HKA) moved through 3.5° varus to 1.2° valgus. The CPAK system was used to visually depict changes in alignment profiles for preoperative valgus, neutral and varus knees; with 63% of patients observing an interval change in classification. CONCLUSION: Encouraged by the latest evidence supporting both conventional instrumentation and kinematic-type TKA strategies, this study describes how a restricted, conventionally instrumented iKA technique may be utilised to restore constitutional lower limb alignment. LEVEL OF EVIDENCE: Level III.

3.
J Arthroplasty ; 39(6): 1524-1529, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38325531

RESUMO

BACKGROUND: This modified Delphi study aimed to develop a consensus on optimal wound closure and incision management strategies for total hip arthroplasty (THA). Given the critical nature of wound care and incision management in influencing patient outcomes, this study sought to synthesize evidence-based best practices for wound care in THA procedures. METHODS: An international panel of 20 orthopedic surgeons from Europe, Canada, and the United States evaluated a targeted literature review of 18 statements (14 specific to THA and 4 related to both THA and total knee arthroplasty). There were 3 rounds of anonymous voting per topic using a modified 5-point Likert scale with a predetermined consensus threshold of ≥ 75% agreement necessary for a statement to be accepted. RESULTS: After 3 rounds of voting, consensus was achieved for all 18 statements. Notable recommendations for THA wound management included (1) the use of barbed sutures over non-barbed sutures (shorter closing times and overall cost savings); (2) the use of subcuticular sutures over skin staples (lower risk of superficial infections and higher patient preferences, but longer closing times); (3) the use of mesh-adhesives over silver-impregnated dressings (lower rate of wound complications); (4) for at-risk patients, the use of negative pressure wound therapy over other dressings (lower wound complications and reoperations, as well as fewer dressing changes); and (5) the use of triclosan-coated sutures (lower risk of surgical site infection) over standard sutures. CONCLUSIONS: Through a structured modified Delphi approach, a panel of 20 orthopedic surgeons reached consensus on all 18 statements pertaining to wound closure and incision management in THA. This study provides a foundational framework for establishing evidence-based best practices, aiming to reduce variability in patient outcomes and to enhance the overall quality of care in THA procedures.


Assuntos
Artroplastia de Quadril , Técnica Delphi , Humanos , Consenso , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/etiologia , Cicatrização , Técnicas de Fechamento de Ferimentos , Europa (Continente) , Canadá , Suturas , Estados Unidos
4.
J Arthroplasty ; 39(4): 878-883, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38244638

RESUMO

BACKGROUND: The purpose of this modified Delphi study was to obtain consensus on wound closure and dressing management in total knee arthroplasty (TKA). METHODS: The Delphi panel included 20 orthopaedic surgeons from Europe and North America. There were 26 statements identified using a targeted literature review. Consensus was developed for the statements with up to three rounds of anonymous voting per topic. Panelists ranked their agreement with each statement on a five-point Likert scale. An a priori threshold of ≥ 75% was required for consensus. RESULTS: All 26 statements achieved consensus after three rounds of anonymous voting. Wound closure-related interventions that were recommended for use in TKA included: 1) closing in semi-flexion versus extension (superior range of motion); 2) using aspirin for venous thromboembolism prophylaxis over other agents (reduces wound complications); 3) barbed sutures over non-barbed sutures (lower wound complications, better cosmetic appearances, shorter closing times, and overall cost savings); 4) mesh-adhesives over other skin closure methods (lower wound complications, higher patient satisfaction scores, lower rates of readmission); 5) silver-impregnated dressings over standard dressings (lower wound complications, decreased infections, fewer dressing changes); 6) in high-risk patients, negative pressure wound therapy over other dressings (lower wound complications, decreased reoperations, fewer dressing changes); and 7) using triclosan-coated over non-antimicrobial-coated sutures (lower risks of surgical site infection). CONCLUSIONS: Using a modified Delphi approach, the panel achieved consensus on 26 statements pertaining to wound closure and dressing management in TKA. This study forms the basis for identifying critical evidence supported by clinical practice for wound management to help reduce variability, advance standardization, and ultimately improve outcomes during TKA. The results presented here can serve as the foundation for knowledge, education, and improved clinical outcomes for surgeons performing TKAs.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Bandagens , Técnica Delphi , Reoperação , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/etiologia , Suturas
5.
Injury ; 55(2): 111185, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38070327

RESUMO

INTRODUCTION: Hip fractures have become a major public health priority due to their increasing incidence. Intramedullary (IM) nailing has gained popularity as a surgical technique for managing these fractures. However, comparative studies with extramedullary devices indicate potentially increased mechanical complications associated with IM nailing. Specifically, there have been recent reports of early implant fracture associated with the TFNA system. This study compares the rate of mechanical complications between 3 implants. Secondarily, we analysed the factors associated with implant fracture and all other mechanical complications. METHODS: This retrospective study included 803 IM nails performed between 2008-2021 for the fixation of proximal femur fractures at a level 1 trauma centre. We recorded patient demographics, AO fracture classification, implant specification and intra-operative parameters such as tip-apex distance, Cleveland index, reduction quality, presence of medial calcar integrity, neck-shaft angle. The outcomes analysed included implant fracture, lag screw cut-out, >10 mm backing out, autodynamisation, periprosthetic fracture, non-union at 6 months and time to revision surgery. RESULTS: The overall implant fracture rate was 3.1 % (25/803), with no statistically significant difference between the three devices (p = 0.51). The TFNA group included 183 patients with a median follow-up of 1.6 years. The TFNA fracture rate was 2.2 % (4/183) which occurred at 207 +/- 16.66 days post-operatively. The rate of all mechanical complications was 4.9 % in the TFNA group, 12.9 % in the InterTAN group and 17 % in the IMHS group. Non-union (p < 0.001) and increasing lag screw length (p < 0.02) were identified as risk factors for implant fracture and other mechanical complications. The reverse oblique fracture pattern (AO 31 A3.1) was associated with mechanical complications only (p < 0.01). The cumulative survival rates without revision for the TFNA, InterTAN, IMHS groups were 97.8 %, 95.5 % and 87.9 % respectively at 2.5 years. DISCUSSION: The rates of implant fracture were comparable between the three nailing systems. The TFNA provides effective fixation for proximal femur fractures using a traditional screw without cement augmentation. The TFNA was associated with an overall reduction in mechanical complications compared to the InterTAN and IMHS. Previously reported mechanical complications associated with IM Nails may relate to older device designs.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Fraturas Proximais do Fêmur , Humanos , Fixação Intramedular de Fraturas/métodos , Pinos Ortopédicos/efeitos adversos , Estudos Retrospectivos , Parafusos Ósseos
6.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 4773-4781, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37516985

RESUMO

PURPOSE: The Attune® total knee arthroplasty system was introduced in 2013 to address lingering issues of patient dissatisfaction. However, recent literature reports concerns of early tibial tray debonding. The aim of this study was to compare the incidence of radiolucent lines, survivorship and patient reported outcome-measures between the Attune® system and the well-established Triathlon® system. METHODS: This retrospective database review was conducted at a single institution in Cork, Ireland. All primary Attune® (N = 445) and Triathlon® (N = 285) systems implanted between 2015 and 2016 were reviewed. Radiolucent lines were assessed for those with a minimum two-year radiological follow-up (Attune® = 338; Triathlon® = 231). X-rays were taken post op, at 6 months, 2 years and 5 years. Radiolucent lines were documented using the Modern Knee Society Radiographic System. Five-year survival was assessed using Kaplan-Meier analysis with the Log Rank method to determine statistical significance. The Oxford Knee Score and EQ-5D-5L, were collected pre-op, at 6 months, 2 years and 5 years post-operatively and compared using the Kruskal-Wallis Test. RESULTS: The Attune® had a higher proportion of radiolucent lines at the tibial tray [87.1% (54/62) vs 61.4% (27/44); p = 0.001] and at the implant-cement interface [62.9% (39/62) vs 43.2% (19/44); p = 0.02]. Conversely, the Triathlon® had a higher proportion AT the femur [38.6% (17/44) vs 12.9% (8/62); p = 0.001] and at the cement-bone interface [56.8% (25/44) vs 37.1% (23/62); p = 0.02]. The overall frequency of radiolucent lines was similar in both the Attune® and Triathlon® groups [17.8%, (60/338) vs 17.7%, (41/231); p = 0.49]. There was no difference in revision-free survival analysis at 5 years (Attune® 97.8% vs Triathlon® 95.8%; p = 0.129). The Attune® performed better at 5 years in the Oxford Knee Score [Attune® = 42.6 (SD 5.2) vs Triathlon® = 41 (SD 6.4); p = 0.001] and in the EQ-5D [Attune® = 0.773 (SD 0.187) vs Triathlon® = 0.729 (SD 0.218); p = 0.013]. There was no difference at 5 years in the EQ-VAS [Attune® = 80.4 (SD 13.7) vs Triathlon® = 78.5 (SD 15.3); p = 0.25]. CONCLUSION: The Attune® system exhibited a higher incidence of  radiolucent lines at the tibial tray. However, this did not lead to decreased survivorship at medium term follow-up compared to the Triathlon®. Furthermore, improvements in patient reported outcomes modestly favoured the Attune® system. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Articulação do Joelho/cirurgia , Radiografia , Desenho de Prótese , Cimentos Ósseos , Falha de Prótese , Resultado do Tratamento
7.
Eur J Orthop Surg Traumatol ; 33(8): 3469-3474, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37191887

RESUMO

PURPOSE: In this study, we aim to evaluate whether the functional outcome of Distal Radius Fractures (DRFs) could be enhanced by shortening the period of immobilisation from six weeks to four weeks. METHODS: This study is a single blinded randomised controlled trial. Four week plaster cast immobilisation was compared with six week plaster cast immobilisation in adult patients (older than 18 years) with adequately reduced DRFs. The primary outcome parameters were functional outcome measured by Quick DASH score after 1-year follow-up. Secondary outcomes were: Quick DASH after three months, 6 months, range of motion, and complications (such as number of re-interventions, secondary displacement, delayed and non-union). RESULTS: 80 patients (16 male and 64 female, mean age, 61.76 years) were included and randomized. 65 patients completed the 1-year follow-up. After 1-year follow up, no significant differences were found between the two groups in the QUICK DASH score (P = 0.55). Moreover, no significant differences in DASH Score after three and six months (P = 0.24, 0.28, respectively). The complication rate among both cohorts was almost similar, (P = 0.51). CONCLUSION: Reduction in the time of cast immobilisation in patients with DRFs in accepted position reported similar outcomes. Of note, the complication rate in the four and six weeks was also the same. Thus, 4 weeks in cast is a safe immobilisation period. Clinical Trials Number Trial registration number and date of registration for prospectively registered trials at http://ClinicalTrials.gov (NCT05012345), on 19/08/2021.


Assuntos
Moldes Cirúrgicos , Fraturas do Rádio , Humanos , Masculino , Adulto , Feminino , Pessoa de Meia-Idade , Moldes Cirúrgicos/efeitos adversos , Amplitude de Movimento Articular , Fraturas do Rádio/terapia
8.
J Biomed Opt ; 27(1)2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34984863

RESUMO

SIGNIFICANCE: Orthopedic surgery currently comprises over 1.5 million cases annually in the United States alone and is growing rapidly with aging populations. Emerging optical sensing techniques promise fewer side effects with new, more effective approaches aimed at improving patient outcomes following orthopedic surgery. AIM: The aim of this perspective paper is to outline potential applications where fiberoptic-based approaches can complement ongoing development of minimally invasive surgical procedures for use in orthopedic applications. APPROACH: Several procedures involving orthopedic and spinal surgery, along with the clinical challenge associated with each, are considered. The current and potential applications of optical sensing within these procedures are discussed and future opportunities, challenges, and competing technologies are presented for each surgical application. RESULTS: Strong research efforts involving sensor miniaturization and integration of optics into existing surgical devices, including K-wires and cranial perforators, provided the impetus for this perspective analysis. These advances have made it possible to envision a next-generation set of devices that can be rigorously evaluated in controlled clinical trials to become routine tools for orthopedic surgery. CONCLUSIONS: Integration of optical devices into surgical drills and burrs to discern bone/tissue interfaces could be used to reduce complication rates across a spectrum of orthopedic surgery procedures or to aid less-experienced surgeons in complex techniques, such as laminoplasty or osteotomy. These developments present both opportunities and challenges for the biomedical optics community.


Assuntos
Procedimentos Ortopédicos , Humanos , Microcirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Procedimentos Neurocirúrgicos
9.
Ir J Med Sci ; 191(1): 163-168, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33587233

RESUMO

Advancement in cancer treatment has prolonged the survival of cancer patients; as a result, there are an increased number of patients with bone metastases and pathological fractures referred to orthopaedic surgeons for surgical intervention for a better quality of life. Metastasis around the hip joint can be painful and intervene with patients' daily activity, and reconstruction of the hip joint with periacetabular metastasis is complex and challenging especially longer cancer survivals might out-live their fixation. Several acetabular reconstruction techniques and implants have been described to overcome this problem; acetabular reconstruction and total hip arthroplasty still remains the standard surgical treatment, to relief pain and to improve function and quality of life. Harrington reconstruction of periacetabular metastatic disease combined with hip arthroplasty is one of the options that can address this clinical scenario safely; it is reproducible and cost-effective. In this review, we present case series of patients treated in our institution using Harrington rod technique for acetabular pathological lesions with good outcome.


Assuntos
Artroplastia de Quadril , Neoplasias Ósseas , Acetábulo/cirurgia , Neoplasias Ósseas/cirurgia , Humanos , Dor , Qualidade de Vida , Resultado do Tratamento
10.
Arch Orthop Trauma Surg ; 142(5): 851-859, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33825970

RESUMO

BACKGROUND: Both Patellofemoral Arthroplasty (PFA) and Total Knee Arthroplasty (TKA) are accepted surgical options for end-stage isolated patellofemoral osteoarthritis (PFOA). We performed a systematic review and meta-analysis to compare outcomes of PFA and TKA by evaluation of the patient-reported outcome measures (PROMs). METHODS: We systematically identified publications reporting on patients that underwent either TKA or modern PFA for isolated PFOA. Meta-analysis software was used to screen for potential articles with at least two years' follow-up. Data were extracted and analysed for all PROMs operating time, postoperative inpatient time, complications and cost. We included five studies in our cumulative meta-analysis and reviewed them using Review Manager V.5.0. We computed the risk ratio as a measure of the treatment effect, taking into account heterogeneity. We used random-effect models. RESULTS: No significant difference was found between both TKA and PFA in the context of operating time. No significant difference after five years' follow-up was found between the two treatment options in terms of UCLA score and patient satisfaction. PFA showed significant improvement in WOMAC score at five-year follow-up, less postoperative inpatient time, better cost-effectiveness and significantly less blood loss. CONCLUSION: PFA seems to be a viable alternative to TKA for treatment of isolated PFOA in appropriately selected patients. PFA showed less postoperative inpatient time and blood loss with similar PROMs to the TKA. Moreover, it is an economically beneficial joint-preserving procedure.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Articulação Patelofemoral , Artroplastia do Joelho/métodos , Humanos , Osteoartrite do Joelho/cirurgia , Articulação Patelofemoral/cirurgia , Satisfação do Paciente , Estudos Retrospectivos , Resultado do Tratamento
11.
Bone Jt Open ; 2(10): 825-833, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34619989

RESUMO

AIMS: The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking. METHODS: Patients were treated in a single level I trauma centre over a 2.5-year period. Group allocation was not randomized; both the micromotion nail and standard-of-care static locking nails (control group) were commercially available and selected at the discretion of the treating surgeons. Injury risk levels were quantified using the Nonunion Risk Determination (NURD) score. Radiological healing was assessed until 24 weeks or clinical union. Low-dose CT scans were acquired at 12 weeks and virtual mechanical testing was performed to objectively assess structural bone healing. RESULTS: A total of 37 micromotion patients and 46 control patients were evaluated. There were no significant differences between groups in terms of age, sex, the proportion of open fractures, or NURD score. There were no nonunions (0%) in the micromotion group versus five (11%) in the control group. The proportion of fractures united was significantly higher in the micromotion group compared to control at 12 weeks (54% vs 30% united; p = 0.043), 18 weeks (81% vs 59%; p = 0.034), and 24 weeks (97% vs 74%; p = 0.005). Structural bone healing scores as assessed by CT scans tended to be higher with micromotion compared to control and this difference reached significance in patients who had biological comorbidities such as smoking. CONCLUSION: In this pilot study, micromotion fixation was associated with improved healing compared to standard tibial nailing. Further prospective clinical studies will be needed to assess the strength and generalizability of any potential benefits of micromotion fixation. Cite this article: Bone Jt Open 2021;2(10):825-833.

12.
Acta Orthop Belg ; 87(1): 93-102, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34129762

RESUMO

Knee osteochondral defects are a common problem among people, especially young and active patients. So effective joint preserving surgeries is essential to prevent or even delay the onset of osteoarthritis for these group of patients. This study aims to critically appraise and evaluate the evidence for the results and effectiveness of femoral condyle resurfacing (HemiCAP/ UniCAP) in treatment of patients with focal femoral condyle cartilage defect. Using the search terms : HemiCAP, UniCAP, Episurf, focal, femoral, condyle, inlay and resur-facing, we reviewed the PubMed and EMBASE and the Cochrane Database of Systematic Reviews (CDSR) to find any articles published up to March 2020. The short term follow-up of the HemiCAP shows (6.74 %) revision rate. However, 29.13 % loss of follow up let us consider these results with caution especially if the revision rate progressively increased with time to 19.3 % in 5-7 years with no enough evidence for the long term results except the data from the Australian Joint Registry 2018, where the cumulative revision rate was 40.6 % (33.5, 48.4) at ten years. The UniCAP that used for defect more than 4 cm 2 has a high revision rate (53.66 %) which is considered unacceptable revision rate in com-parison to another similar prosthesis such as Uni-Knee Arthroplasty (UKA). The evidence from published studies and our meta- analysis suggests that partial resurfacing of the femoral condyle (HemiCAP) doesn't support its usage as a tool to treat the focal cartilage defect in middle- aged patients. The UniCAP as femoral condyle resurfacing has very high revision rate at 5-7 years (53.66 %) which make us recommend against its usage.


Assuntos
Cartilagem Articular , Prótese do Joelho , Idoso , Austrália , Cartilagem , Cartilagem Articular/cirurgia , Fêmur/cirurgia , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Reoperação , Resultado do Tratamento
13.
Arthroplast Today ; 8: 283-288.e1, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34095405

RESUMO

We report a case of a fracture through the polyethylene (PE) insert cone in a rotating-platform (RP) primary total knee arthroplasty (TKA) implant. This is the first reported case of cone fracture with this particular implant. This case highlights a 65-year-old female presenting with a 4-month history of knee pain and symptoms of instability 10 years after primary RP TKA. At the time of revision surgery, the PE insert cone was found to be fractured 10 mm from the inferior surface of the PE liner. Analysis suggests that the cone fracture occurred by fatigue failure which caused loosening of the tibial tray. Clinicians should be aware that this is a potential cause of failure with an RP TKA in the setting of symptoms including instability and pain.

14.
BMJ Case Rep ; 14(2)2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-33542017

RESUMO

A 74-year-old patient presented to the emergency department with acute atraumatic hip pain 9 years after her primary left total hip arthroplasty (THA). Plain radiographic imaging demonstrated lateralisation of the femoral head within the acetabular shell-indicating an issue with the polyethylene liner. The patient required revision of the acetabular component and the femoral head, as well as a new polyethylene liner. A detailed analysis of the components removed was performed by DePuy Synthes Engineering. Between 2009 and 2020, 8 publications have documented 52 cases of liner dissociation with the Pinnacle acetabular component and Marathon polyethylene liner. Various theories have been proposed in the literature as all of these components appear to fail in the same way, with shearing of the locking tabs in the polyethylene liner. In spite of a manufacturer analysis of the components, no root cause was identified as to why the polyethylene liner failed.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Polietileno/efeitos adversos , Falha de Prótese , Idoso , Feminino , Humanos , Radiografia , Reoperação
15.
J Arthroplasty ; 36(5): 1740-1745, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33468343

RESUMO

BACKGROUND: Paprosky type IIIa and IIIb acetabular defects remain technically challenging during revision hip arthroplasty. Numerous surgical options exist to counter extensive acetabular bone loss with high postoperative complication and revision rates reported. Our aim was to report comprehensive long-term outcomes of our experience with Trabecular Metal (TM) augments for these difficult cases. METHODS: 38 patients underwent revision total hip arthroplasty at our institution from 2009 to 2014 where a TM augment was used for acetabular deficiency. Prospective radiographic and Patient-Reported Outcome Measures were recorded and analyzed to a mean of 7.3 years (range: 5.4 to 10.8). RESULTS: No patient was excluded or lost to follow-up. Complications included 3 intraoperative fractures, 1 early infection requiring washout with implant retention, 1 early revision due to allograft resorption, and 6 patients who required late repeat revision surgery: 3 for late infection, 2 for aseptic loosening with augment fracture or dislocation, and 1 for recurrent dislocation. The estimated mean implant survivorship was 8.99 years. 93.5% of augments remaining were well osseointegrated while 97% of the acetabular shells were osseointegrated. Hip center of rotation was restored by a mean of 14 mm inferiorly without significant medialization. Short Form-12 (SF-12) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were significantly reduced postoperatively to a level comparable to the average individual. CONCLUSION: This long-term study details our experience of TM augments for the most severe acetabular defects. For such cases, no excellent surgical solution exists; in comparison to alternative methods, we advocate that this technique is reasonably safe and effective.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Ontário , Estudos Prospectivos , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
16.
Ir J Med Sci ; 190(2): 647-652, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32815116

RESUMO

BACKGROUND: Patellar instability is a disabling condition that limits the functional ability and physical aspirations of patients. There are multiple anatomical structures which stabilize the patella and surgical treatment is tailored to repair the underlying aetiology. AIMS: To evaluate the clinical and radiological outcome of patellar stabilization procedures in patients with recurrent patellar instability. METHODS: We analysed 34 patients (36 knees) (mean age, 26.6) with recurrent patellar instability who underwent patellar stabilization surgery from June 2009 to September 2014. Type of procedure was dependent on the concomitant aetiological factors; tibial tuberosity osteotomy (61.76%), medial patellofemoral ligament reconstruction (67.64%), lateral release (5.88%) and trochleoplasty (2.94%). Mean follow-up was 3 years (range 9 months-6 years). RESULTS: At follow-up, 77% of patients were satisfied with the overall outcome of the procedure. The mean IKDC was 66.7, Lysholm 74.9. Mean patellar height decreased significantly (P < .05) to anatomical values. Pre-operatively, the mean tibial tuberosity-trochlear groove distance was 14.66 mm (55.6% at borderline/abnormal level) and 81% showed evidence of trochlear dysplasia. Complications were found in 3 patients (8.33%), 2 of which had further episodes of instability. CONCLUSIONS: Patellar stabilization surgery is an effective method of treating patellar instability, resulting in stability of the knee in 94.4%. Despite this, patient dissatisfaction rates are quite high suggesting that this patient group, whilst mostly stable, remains significantly symptomatic from their knee. These positive results which are reflected in the recent literature represent a strong case for consideration of primary surgical stabilization in cases of patellar instability.


Assuntos
Instabilidade Articular/cirurgia , Patela/patologia , Luxação Patelar/cirurgia , Radiografia/métodos , Adulto , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos
17.
HSS J ; 16(Suppl 1): 92-96, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33041725

RESUMO

BACKGROUND: The effect of COVID-19 on pediatric trauma rates is still largely under investigation. With the potential need to reallocate human and financial resources at this challenging time, it will be useful to have detailed descriptions of the rates of pediatric trauma and understanding of how the pandemic affects these rates. QUESTIONS/PURPOSES: We sought to describe the effect of the COVID-19 pandemic on the number of acute pediatric trauma admissions and procedures performed in a level-I trauma center in Cork University Hospital, Ireland. METHODS: We compared the number of acute traumatic pediatric admissions and procedures that occurred during the first 4 weeks of a nationwide lockdown due to COVID-19 with that of the same 4-week period in each of the preceding 11 years. Seasonal variables were measured and controlled for using multivariate regression analysis. RESULTS: A total of 545 pediatric patients (under 16 years of age) were included. Over 12 years, the lowest number of acute traumatic pediatric admissions and procedures was recorded during the 2020 pandemic. There was a significant correlation between the number of school days and the number of acute traumatic admissions, as well as the procedures performed. The relationship between the number of school days and the number of trauma procedures was evident even when controlling for confounder variables of seasonal variation. CONCLUSION: The COVID-19 pandemic significantly reduced the number of acute traumatic pediatric admissions and procedures performed in our level-I trauma center, likely because of a reduction in school days. With the reopening of schools, playgrounds, and sporting events, an increase in pediatric trauma admissions is anticipated. The results of this study can help prepare institutions and regulatory bodies to plan appropriately for this new phase.

18.
Knee Surg Relat Res ; 32(1): 36, 2020 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-32698908

RESUMO

INTRODUCTION: Polyethylene (PE) spinout is a known but uncommon complication when using a mobile-bearing (MB) total knee arthroplasty (TKA) design. Sacrificing the posterior cruciate ligament (PCL) is within the manufacturer's recommendations for the Attune® Cruciate-Retaining Rotating-Platform (CR RP) knee design. AIM: To discuss the potential aetiology and prevention of spinout in the Attune® CR RP knee. METHODS: We used a retrospective radiological review from two centres reporting a higher rate of spinout in the Attune® CR RP knee using a cruciate-sacrificing and measured-resection technique when compared to a gap-balancing technique. Three hundred and thirty-two patients were evaluated over a 3-year period. RESULTS: There were 8 out of 279 (2.86%) cases of spinout in our first cohort of patients using a measured-resection technique. There were 0 out of 53 cases of spinout in our second cohort of patients where a gap-balancing technique was used. One spinout was reduced closed, the other seven were initially revised to a thicker RP insert of the same design. Of these seven, three underwent a further revision TKA and one patient required a knee fusion/arthrodesis. CONCLUSIONS: This study reports a higher incidence of PE spinout in the Attune® CR RP TKA when a measured-resection technique in combination with PCL resection is performed. We recommend a gap-balancing technique with conservative soft-tissue release if the surgeon is planning to sacrifice the PCL in the Attune® CR RP.

19.
Ir J Med Sci ; 189(4): 1323-1329, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32445117

RESUMO

BACKGROUND: The rate of ACL injury in adolescents has been rising in recent years. Surgical options include transphyseal and physeal-sparing ACL reconstruction. AIMS: In this study, we performed a transphyseal ACL reconstruction and followed up patients to assess functional outcomes and to assess for growth disturbance. METHOD: There were 22 patients seen at follow-up between the age of 12 and 16. Skeletal age assessment was performed using an MRI atlas with an average skeletal age of 14.7 (range 12-16). The mean follow-up time was 36 months (range 14-63 months). Clinical examination was performed to assess for leg length discrepancy, and leg length radiographs were used to assess for angular deformity. Patients' post-surgery functionality was assessed with the IKDC score and the Tegner Lysholm score. RESULTS: The mean IKDC and Lysholm scores at follow-up were found to be 91 and 94, respectively. The median Tegner score prior to injury was 8.5 and postoperatively was 7.5. There were no cases of leg length discrepancy found on clinical examination, and there were no cases of significant angular deformity. Four patients ruptured again and went on to have repeat ACL reconstruction. CONCLUSIONS: Midterm results at an average follow-up of 3 years after the surgery showed good functional outcomes using the transphyseal ACL reconstruction technique with good return to activity. There were no cases of leg length discrepancy or angular deformity. Transphyseal ACL reconstruction is a viable method of treatment for adolescent ACL tears.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Adolescente , Feminino , Seguimentos , Humanos , Irlanda , Masculino , Estudos Retrospectivos , Resultado do Tratamento
20.
J Arthroplasty ; 35(8): 2195-2199, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32327285

RESUMO

BACKGROUND: We describe the intraoperative parameters that affect stem subsidence rates in tapered modular femoral stems for revision total hip arthroplasty (THA). We also determine the effect of the stem bicortical contact on subsidence rates and whether there is a minimum threshold bicortical contact that must be achieved to avoid the complication of subsidence. METHODS: This is a retrospective cohort study consisting of 109 hips in 105 patients (53 males and 52 females) at a minimum of 2 years of follow-up. All revisions were carried out for Paprosky type 3A and 3B femoral deficits. Clinical outcomes included the indication for revision, aseptic re-revision surgery, specifications of the stem inserted, and specifications of the femoral head and acetabular components implanted. Radiographic outcome measures included subsidence (mm) and bicortical contact (mm). RESULTS: Using multivariate regression analysis, 3 parameters were associated with an increased rate of stem subsidence. A reduced bicortical contact distance (P < .001) and a stem length of ≤155 mm (P < .001) were both associated with higher subsidence rates. We also demonstrated a novel threshold of 20-mm bicortical contact which must be achieved to significantly reduce subsidence rates in these modular femoral stems for revision THA. CONCLUSION: Subsidence rates of modular tapered femoral stems for revision THA can be significantly reduced by increasing the initial bicortical contact of the stem within the diaphysis and the overall length of the femoral stem >155 mm. We describe a minimum threshold bicortical contact distance of 20 mm that should ideally be exceeded to significantly reduce the risk of stem subsidence within the femoral canal.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA