Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(5): 994-1004, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501333

RESUMO

INTRODUCTION: When ventricular tachycardia (VT) recurs after standard RF ablation (sRFA) some patients benefit from repeat sRFA, whereas others warrant advanced methods such as intramural needle ablation (INA). Our objectives are to assess the utility of repeat sRFA and to clarify the benefit of INA when repeat sRFA fails in patients with VT due to structural heart disease. METHODS: In consecutive patients who were prospectively enrolled in a study for INA for recurrent sustained monomorphic VT despite sRFA, repeat sRFA was considered first. INA was performed during the same procedure if repeat sRFA failed or no targets for sRFA were identified. RESULTS: Of 85 patients enrolled, acute success with repeat sRFA was achieved in 30 patients (35%), and during the 6-month follow-up, 87% (20/23) were free of VT hospitalization, 78% were free of any VT, and 7 were lost to follow-up. INA was performed in 55 patients (65%) after sRFA failed, or no endocardial targets were found abolished or modified inducible VT in 35/55 patients (64%). During follow-up, 72% (39/54) were free of VT hospitalization, 41% were free of any VT, and 1 was lost to follow-up. Overall, 59 out of 77 (77%) patients were free of hospitalization and 52% were free of any VT. Septal-origin VTs were more likely to need INA, whereas RV and papillary muscle VTs were less likely to require INA. CONCLUSIONS: Repeat sRFA was beneficial in 23% (18/77) of patients with recurrent sustained VT who were referred for INA. The availability of INA increased favorable outcomes to 52%.


Assuntos
Ablação por Cateter , Cicatriz , Recidiva , Reoperação , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Cicatriz/fisiopatologia , Cicatriz/diagnóstico , Cicatriz/cirurgia , Cicatriz/etiologia , Fatores de Tempo , Potenciais de Ação , Agulhas , Frequência Cardíaca , Fatores de Risco , Resultado do Tratamento
2.
JACC Clin Electrophysiol ; 10(3): 487-498, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38206263

RESUMO

BACKGROUND: Desmoplakin (DSP) pathogenic/likely pathogenic (P/LP) variants are associated with malignant phenotypes of arrhythmogenic cardiomyopathy (DSP-ACM). Reports of outcomes after ventricular tachycardia (VT) ablation in DSP-ACM are scarce. OBJECTIVES: In this study, the authors sought to report on long-term outcomes of VT ablation in DSP-ACM. METHODS: Patients with P/LP DSP variants at 9 institutions undergoing VT ablation were included. Demographic, clinical, and instrumental data as well as all ventricular arrhythmia (VA) events were collected. Sustained VAs after the index procedure were the primary outcome. A per-patient before and after ablation comparison of rates of VA episodes per year was performed as well. RESULTS: Twenty-four DSP-ACM patients (39.3 ± 12.1 years of age, 62.5% male, median 6,116 [Q1-Q3: 3,362-7,760] premature ventricular complexes [PVCs] per 24 hours, median 4 [Q1-Q3: 2-11] previous VA episodes per patient at ablation) were included. Index procedure was most commonly endocardial/epicardial (19/24) The endocardium of the right ventricle (RV), the left ventricle (LV), or both ventricles were mapped in 8 (33.3%), 9 (37.5%), and 7 (29.2%) cases, respectively. Low voltage potentials were found in 10 of 15 patients in the RV and 11 of 16 in the LV. Endocardial ablation was performed in 18 patients (75.0%). Epicardial mapping in 19 patients (79.2%) identified low voltage potentials in 17, and 16 received epicardial ablation. Over the following 2.9 years (Q1-Q3: 1.8-5.5 years), 13 patients (54.2%) experienced VA recurrences. A significant reduction in per-patient event/year before and after ablation was observed (1.4 [Q1-Q3: 0.5-2.4] to 0.1 [Q1-Q3: 0.0-0.4]; P = 0.009). Two patients needed heart transplantation, and 4 died (3 of heart failure and 1 noncardiac death). CONCLUSIONS: VT ablation in DSP-ACM is effective in reducing the VA burden of the disease, but recurrences are common. Most VT circuits are epicardial, with both LV and RV low voltage abnormalities. Heart failure complicates clinical course and is an important cause of mortality.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Ablação por Cateter , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Desmoplaquinas , Resultado do Tratamento , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/cirurgia , Cardiomiopatias/etiologia , Ablação por Cateter/métodos , Insuficiência Cardíaca/etiologia
3.
J Arrhythm ; 39(1): 84-87, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36733322

RESUMO

No case of AF ablation after right-sided pneumonectomy has been reported, presumably because the pneumonectomy renders the ablation procedure more difficult than lobectomy because of the marked mediastinal displacement. In the case of catheter ablation of AF after right-sided pneumonectomy, it is extremely important to insert a mapping catheter not only into the PV but also into the SVC to accurately diagnose the site of abnormal electrical activity.

4.
J Interv Card Electrophysiol ; 65(1): 123-131, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35488961

RESUMO

BACKGROUND: An acute cryothermal ablation lesion contains both reversible and irreversible elements. However, differences in lesions created with cryoballoon pulmonary vein isolation (PVI) between the acute and chronic phases have not been fully elucidated. METHODS: We retrospectively analyzed 23 consecutive patients with atrial fibrillation who underwent cryoballoon PVI during the initial procedure followed by a second ablation procedure. In all patients, cryoballoon PVI lesions were evaluated with high-resolution voltage mapping just after PVI (acute phase) and during the second session (chronic phase). We compared the area and width of the non-isolated left atrial posterior wall (NI-LAPW) with voltage ≥ 0.5 mV during both sessions. RESULTS: PVI was successfully achieved in all patients. Cryoballoon PVI lesions were re-evaluated at 11 [2-17] months post-procedure. During the chronic phase, NI-LAPW width became significantly larger at the level of the roof (change, 5.8 ± 5.5 mm; p < 0.001) and at the level of the carina (change, 3.3 ± 7.0 mm; p < 0.05), and NI-LAPW area became significantly larger (change, 1.5 ± 1.9 cm2; p < 0.001) compared with the acute phase. Eight patients without any PV reconnections also had larger NI-LAPW areas (change, 1.3 ± 1.2 cm2; p < 0.05) during the chronic phase. Conduction resumption confined to the right carina was observed in 1 (4.3%) patient who presented with circumferential PVI that included the carina during the first session. CONCLUSION: Acute cryoballoon PVI lesions significantly regressed during the chronic phase. PV reconnections and the isolation area should be carefully re-evaluated during the second procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
5.
BMC Cardiovasc Disord ; 22(1): 57, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35172730

RESUMO

BACKGROUND: Left atrial roof-dependent tachycardias (LARTs) are common macroreentrant atrial tachycardias (ATs). We sought to characterize clinical LARTs using an ultra-high resolution mapping system. METHODS: This study included 22 consecutive LARTs in 21 patients who underwent AT mapping/ablation using Rhythmia systems. RESULTS: Three, 13, 4, and 2 LART patients were cardiac intervention naïve (Group-A), post-roof line ablation (Group-B), post-atrial fibrillation ablation without linear ablation (Group-C), and post-cardiac surgery (Group-D), respectively. The mean AT cycle length was 244 ± 43 ms. Coronary sinus activation was proximal-to-distal or distal-to-proximal in 16 (72.7%) ATs. The activation map revealed 13 (59.1%) clockwise and 9 (40.9%) counter-clockwise LARTs. A 12-lead synchronous isoelectric interval was observed in 10/19 (52.6%) LARTs. The slow conduction area was identified on the LA roof, anterior/septal wall, and posterior wall in 18, 6, and 2 ATs, respectively. Twenty concomitant ATs among 13 procedures were also eliminated, and peri-mitral AT coexisted in 7 of 9 non-group-B patients. In group-B, the conduction gap was predominantly located on the mid-roof. Sustained LARTs were terminated by a single application and linear ablation in 6 (27.3%) and 9 (40.9%), while converting to other ATs in 7 (31.8%) LARTs. Complete linear block was created without any complications in all, however, ablation at the mid-posterior wall was required to achieve block in 4 (18.2%) procedures. During 14.0 (6.5-28.5) months of follow-up, 17 (81.0%) and 19 (90.5%) patients were free from any atrial tachyarrhythmias after single and last procedures. CONCLUSIONS: The LART mechanisms were distinct in individual patients, and elimination of all concomitant ATs was required for the management.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Átrios do Coração/cirurgia , Taquicardia Supraventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
6.
Int Heart J ; 63(1): 49-55, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35095076

RESUMO

The diagnosis of cardiac amyloidosis is frequently delayed because histological confirmation is often challenging. Few studies have attempted to clarify the utility and safety of abdominal fat pad fine-needle aspiration (FPFNA) for an initial screening test in patients with suspected cardiac amyloidosis.This study included 77 consecutive patients with suspected non-ischemic cardiomyopathy who had left ventricular dysfunction and/or hypertrophy. All patients underwent abdominal FPFNA and an endomyocardial biopsy. In all patients, the abdominal FPFNA could be performed within less than 5 minutes with no complications; however, in 1 patient (1.3%), the obtained specimen was too small to evaluate. Among the remaining 76 patients, 5 (6.6%) were positive for amyloid (FPFNA[+]) and 7 (9.2%), including the 5 FPFNA[+], were diagnosed with cardiac amyloidosis (AL = 1, ATTR = 6) by endomyocardial biopsy. Positive abdominal FPFNAs indicated cardiac amyloidosis with high accuracy (sensitivity, 71.4%; specificity, 100%).Positive abdominal FPFNAs are directly linked to diagnoses of cardiac amyloidosis. Abdominal FPFNA is simple and useful for the initial screening test for cardiac amyloidosis in patients with non-ischemic cardiomyopathy.


Assuntos
Gordura Abdominal/patologia , Amiloidose/diagnóstico , Biópsia por Agulha Fina , Cardiopatias/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Endocárdio/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico
7.
Pacing Clin Electrophysiol ; 45(5): 589-597, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34427933

RESUMO

BACKGROUND: Additional benefit of cryoballoon left atrial roof line ablation (CB-RA) beyond cryoballoon pulmonary vein isolation (CB-PVI) is suggested in patients with persistent atrial fibrillation (PsAF). We sought to investigate the feasibility of CB-RA for PsAF and to determine the ablation area. METHODS AND RESULTS: Fifty-three PsAF patients (67[58.5-75.5] years, 36 men, 11 longstanding PsAF) underwent CB-PVI. Subsequently, 44(83.0%) out of 53 patients underwent additional CB-RA. Voltage maps were created in all patients with a high-resolution mapping system. The total number and duration of CB-RAs were 3.9 ± 0.7 and 468 ± 84 s. LA roof areas were complete low voltage areas (LVAs) /scar in 37/44(84.1%) patients ("complete roof modification"). The normal LA posterior wall (LAPW) voltage area was 6.1(4.1-8.4) cm2 , and the %LAPW isolation area was 61.0(47.2-71.7)%. The %LAPW isolation area was significantly greater in CB-RA patients than those without (64.0[54.2-73.2] vs. 45.0[39.5-50.5]%, p = .041) despite significantly larger LAs in the former group. The %LAPW isolation area was significantly greater in patients with transverse LA diameters < 45 mm than those ≥ 45 mm (p < .0001). The single procedure 1-year AF freedom was 87.4% (22.5% on antiarrhythmic drug) and tended to be higher in CB-RA patients than those without. Among the 44 CB-RA patients, it was significantly higher in patients with a complete roof modification than those without (94.4% vs. 75.0%, p = .0049). One CB-RA patient experienced a delayed cardiac tamponade requiring drainage at 4-months post-procedure. CONCLUSIONS: CB-RA significantly expanded the LAPW isolation area, and a complete roof modification resulted in a high arrhythmia freedom in PsAF patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
8.
J Interv Card Electrophysiol ; 63(1): 143-152, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33575920

RESUMO

BACKGROUND: The novel fourth-generation cryoballoon (4th-CB) is characterized by a shorter-tip that potentially facilitates better time-to-isolation (TTI) monitoring. We sought to clarify the advantages and disadvantages of the 4th-CB compared to the second-generation cryoballoon (2nd-CB) in pulmonary vein isolation (PVI). METHODS: Forty-one and 49 consecutive atrial fibrillation patients underwent 2nd-CB and 4th-CB PVIs using 28-mm balloons and short freeze strategies. When effective freezing was not obtained, the CB was switched to the other CB. RESULTS: The rate of successful PVIs was significantly higher for 2nd-CBs than 4th-CBs (162/162[100%] vs. 178/193[92.2%] PVs, p < 0.0001). The difference was significant for lower PVs, especially right inferior PVs (RIPVs)(p = 0.005). In a total of 15 PVs in 11 patients, 4th-CBs were switched to 2nd-CBs, and 14/15(93.3%) PVs were successfully isolated. The balloon temperature tended to reach -55℃ more frequently with 2nd-CBs than 4th-CBs during RIPV ablations (15/41[36.6%] vs. 12/49[24.5%], p = 0.21). The TTI monitoring capability was significantly higher with 4th-CBs than 2nd-CBs (131/188[69.7%] vs. 83/160[51.9%] PVs, p = 0.0007). The difference was significant for right superior and left inferior PVs, but not for left superior PVs. Even if PVs requiring crossover were excluded, the total freeze duration (715±152 vs. 755±215 seconds, p = 0.31) tended to be shorter for 2nd-CBs than 4th-CBs. The incidence of phrenic nerve injury was similar for 2nd-CB and 4th-CB ablation (0/41 vs. 2/49, p = 0.12) CONCLUSIONS: The 4th-CB's shorter balloon tip enabled a significantly higher capability of TTI monitoring; however, it resulted in significantly lower rates of successful PVIs than the 2nd-CB, especially for the RIPVs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Congelamento , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
9.
J Interv Card Electrophysiol ; 64(2): 291-300, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33755817

RESUMO

BACKGROUND: A novel technology able to measure the local impedance (LI) during radiofrequency ablation has become available for clinical use. We investigated the change in the LI characteristics during superior vena cava isolations (SVCIs) using a novel catheter equipped with mini-electrodes. METHODS: Twenty paroxysmal atrial fibrillation patients (68 ± 9 years; 14 males) underwent an SVCI by targeting breakthroughs. Subsequently, dormant conduction provoked by adenosine triphosphate (ATP) was evaluated. RESULTS: Electrical SVCIs were successfully achieved in all with 7.2 ± 3.0 radiofrequency applications (RFA) without any complications. The procedure and fluoroscopic times were 13.1 ± 8.1 and 2.8 ± 2.3 min. No ablation was required at the anteroseptal SVC in 19 (95.0%) patients. The baseline LI and generator impedance (GI) were 125 ± 23 and 105 ± 14Ω. LI drops during RFA were significantly greater than GI drops (17 ± 12 vs. 4 ± 4Ω, p < 0.001). The correlation between the LI drops and GI drops was relatively high (R = 0.69, p < 0.001). LI drops were highest at the septal SVC and lowest at the lateral followed by antero-lateral SVC. The baseline electrogram amplitude between the mini-electrodes and tip-ring electrodes was 1.2 ± 1.4 and 0.8 ± 0.6 mV. The mini-electrode amplitude is more sharply attenuated with a greater magnitude than the tip-ring amplitude (p < 0.001). ATP-provoked dormant conduction was exposed in 10/17 (58.8%) patients and antero-lateral SVC gap locations in 7. Antero-lateral SVC LI drops were similar between patients with and without dormancy. CONCLUSIONS: The LI drop magnitude during RFA significantly differed among the SVC segments. Antero-lateral SVC ATP-provoked dormant conduction was often exposed, and additional applications are recommended following the isolation for a robust SVCI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Trifosfato de Adenosina , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Catéteres , Impedância Elétrica , Humanos , Masculino , Veias Pulmonares/cirurgia , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
10.
J Interv Card Electrophysiol ; 64(3): 581-586, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34292463

RESUMO

BACKGROUND: The time-to-isolation (TTI) may be a physiological predictor of durable isolations, and TTI-guided dosing strategies are widely performed in cryoballoon ablation. We sought to investigate the impact of the order of targeting the pulmonary veins (PVs) on the TTI values of left ipsilateral PVs. METHODS: This study included 144 atrial fibrillation patients who underwent PV isolations using 28-mm fourth-generation cryoballoons. In 101 patients, the left superior PV (LSPV) was targeted and followed by the left inferior PV (LIPV) (group 1), and the LIPV was targeted and followed by the LSPV in the remaining 43 (group 2). RESULTS: The total LSPV and LIPV freeze durations were 193 ± 60 and 171 ± 40 s, respectively. Real-time PV isolation monitoring was capable in 137 (95.1%) LSPVs and 119 (82.6%) LIPVs and in 112 (77.8%) patients (78 in group 1 and 34 in group 2) in both LSPVs and LIPVs. Among them, the LSPV TTI was significantly longer in group 1 than that in group 2 (54.8 ± 32.1 vs. 34.1 ± 17.3 s, p < 0.0001), while the LIPV TTI was significantly shorter in group 1 than that in group 2 (23.7 ± 11.8 vs. 39.2 ± 19.4 s, p < 0.0001). The ΔTTI ((TTI in LSPV)-(TTI in LIPV)) was significantly greater in group 1 than that in group 2 (31.1 ± 31.4 vs. - 5.0 ± 25.9 s, p < 0.0001). In 5 patients (3 in group 1 and 2 in group 2), initially targeted left PVs were not isolated despite complete vein occlusions, while they were by subsequent applications at the other ipsilateral PVs. CONCLUSIONS: In CB ablation, the order of targeting PVs highly influenced the TTI of the left PVs owing to the presence of electrical connections between left ipsilateral PVs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Congelamento , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
11.
Int J Cardiol ; 350: 41-47, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34954279

RESUMO

BACKGROUND: Data on additional substrate modification using a cryoballoon beyond cryoballoon pulmonary vein isolation (CB-PVI) is limited. We sought to evaluate the efficacy and safety of substrate modification on the left atrial roof area using CBs (LAR-CBs) for atrial fibrillation (AF) patients. METHODS: Eighty-one AF patients (70.0[62.5-77.0] years, 33 paroxysmal AF[PAF], 48 non-PAF) underwent LAR-CBs following CB-PVIs. Voltage maps were created with a high-resolution mapping system. Roof line conduction block was evaluated during the repeat procedure. RESULTS: The total number of applications for the CB-PVI and LAR-CB were 5.0 ± 1.2 and 3.8 ± 0.7, and both were significantly greater in non-PAF than PAF patients. LA roof areas had continuous scar in 61/79(77.2%) patients, and the mean balloon temperature was significantly lower in patients with continuous scar than those without (-39.3 ± 3.8 vs. -36.0 ± 4.6 °C, p = 0.004). The single procedure 1-year AF freedom was 87.6% (7.5% on antiarrhythmic drug) and was similar between PAF and non-PAF patients (p = 0.14). Twelve (14.8%) patients underwent a second procedure 5.5(2.2-7.5) months later, and a mean of 1.3 ± 0.5 PVs were reconnected in 7/12(58.3%) patients. Electrical conduction block across the roof line was proven in 3/12(25.0%) patients. There were 6(7.4%) complications related to the procedures, including iatrogenic roof dependent atrial tachycardia, takotsubo cardiomyopathy, and severe pericarditis in 1, 1, and 2 patients, respectively. CONCLUSIONS: LA roof area substrate modification using CBs yielded a high arrhythmia freedom after single procedures. However, a low incidence of electrical conduction block across the line during the chronic phase and delayed complications were the major concerns.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Estudos de Viabilidade , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 32(9): 2418-2423, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34258810

RESUMO

BACKGROUND: In cryoballoon ablation, applications for right superior pulmonary veins (RSPVs) inevitably need to be interrupted for some safety reasons. We retrospectively investigated the RSPV isolation durability after single interrupted short freezes. METHODS: Data from 30 patients who underwent repeat procedures 8.2 (4.1-13.8) months after an inevitably interrupted single short freeze (<180 s) for RSPVs during the index cryoballoon procedures were analyzed. It was interrupted by active deflation due to phrenic nerve injury (PNI) (Group 1: n = 14) or passive deflation due to a balloon temperature of -60°C (Group 2: n = 16). RESULTS: The freezing time was 145 (107-166) and 142 (127-160) s and nadir balloon temperature -50.7 ± 3.6 and -60°C in Groups 1 and 2, respectively. Pulmonary vein isolation was achieved after interrupted freezing in all except in one patient requiring touch-up ablation in Group 1. All PNI was asymptomatic and recovered during the follow-up. Eight/13 (61.5%) and 16/16 (100%) RSPVs were durable during the second procedure in Groups 1 and 2. In Group 1, the freezing time was significantly longer in durable than reconnected RSPVs (p = .032), and the optimal cutoff point for the freezing duration to predict the durability was 94.0 s (sensitivity 100%, specificity 60.0%). When the freezing time was ≥120 s, 80% of the RSPVs were durable. However, when the freezing time was ≤68 s, all RSPVs were reconnected. CONCLUSIONS: The feasibility of second cryoapplications for RSPVs should be discussed considering the freezing time of the interrupted initial applications in Group 1, however, it was not necessary in Group 2.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Congelamento , Humanos , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
13.
Intern Med ; 60(22): 3543-3549, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34092728

RESUMO

Objectve To assess the impact of glycemic variability on blood pressure in hospitalized patients with cardiac disease. Methods In 40 patients with cardiovascular disease, the glucose levels were monitored by flash continuous glucose monitoring (FGM; Free-Style Libre™ or Free-Style Libre Pro; Abbott, Witney, UK) and self-monitoring blood glucose (SMBG) for 14 days. Blood pressure measurements were performed twice daily (morning and evening) at the same time as the glucose level measurement using SMBG. Results The detection rate of hypoglycemia using the FGM method was significantly higher than that with the 5-point SMBG method (77.5% vs. 5.0%, p<0.001). Changes in the systolic blood pressure from evening to the next morning [morning - evening (ME) difference] were significantly correlated with night glucose variability (r=0.63, P<0.001). A multiple regression analysis showed that night glucose variability using FGM was more closely correlated with the ME difference [r=0.62 (95% confidence interval, 0.019-0.051); p<0.001] than with the age, body mass index, or smoking history. Night glucose variability was also more closely associated with the ME difference in patients with unstable angina pectoris (UAP) than in those with acute myocardial infarction (AMI) or heart failure (HF) (r=0.83, p=0.058). Conclusion Night glucose variability is associated with the ME blood pressure difference, and FGM is more accurate than the 5-point SMBG approach for detecting such variability.


Assuntos
Automonitorização da Glicemia , Cardiopatias , Glicemia , Pressão Sanguínea , Glucose , Humanos
14.
J Am Heart Assoc ; 10(5): e017267, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33599136

RESUMO

Background Medical castration, gonadotropin-releasing hormone agonists, and antiandrogens have been widely applied as a treatment for prostate cancer. Sex steroid hormones influence cardiac ion channels. However, few studies have examined the proarrhythmic properties of medical castration. Methods and Results This study included 149 patients who underwent medical castration using gonadotropin-releasing hormones with/without antiandrogen for prostate cancer. The changes in the ECG findings during the therapy and associations of the electrocardiographic findings with malignant arrhythmias were studied. The QT and corrected QT (QTc) intervals prolonged during the therapy compared with baseline (QT, 394±32 to 406±39 ms [P<0.001]; QTc, 416±27 to 439±31 ms [P<0.001]). The QTc interval was prolonged in 119 (79.9%) patients during the therapy compared with baseline. In 2 (1.3%) patients who had no structural heart disease, torsade de pointes (TdP) and ventricular fibrillation (VF) occurred ≥6 months after starting the therapy. In patients with TdP/VF, the increase in the QTc interval from the pretreatment value was >80 ms. However, in patients without TdP/VF, the prevalence of an increase in the QTc interval from the pretreatment value of >50 ms was 11%, and an increase in the QTc interval from the pretreatment value >80 ms was found in only 4 (3%) patients. Conclusions Medical castration prolongs the QT/QTc intervals in most patients with prostate cancer, and it could cause TdP/VFs even in patients with no risk of QT prolongation before the therapy. An increase in the QTc interval from the pretreatment value >50 ms might become a predictor of TdP/VF. Much attention should be paid to the QTc interval throughout all periods of medical castration to prevent malignant arrhythmias.


Assuntos
Antagonistas de Androgênios/farmacologia , Arritmias Cardíacas/epidemiologia , Castração/efeitos adversos , Eletrocardiografia , Hormônio Liberador de Gonadotropina/antagonistas & inibidores , Neoplasias da Próstata/tratamento farmacológico , Medição de Risco/métodos , Idoso , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/fisiopatologia , Castração/métodos , Seguimentos , Humanos , Japão/epidemiologia , Masculino , Estudos Retrospectivos , Fatores de Risco
15.
Heart Vessels ; 36(7): 1027-1034, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33507357

RESUMO

Reported mapping procedures of left atrial (LA) low-voltage areas (LVAs) vary widely. This study aimed to compare the PentaRay®/CARTO®3 (PentaRay map) and Orion™/Rhythmia™ (Orion map) systems for LA voltage mapping. This study included 15 patients who underwent successful pulmonary vein isolation (PVI) for atrial fibrillation. After PVI, PentaRay and Orion maps created for all patients were compared. LVAs were defined as sites with ≥ 3 adjacent low-voltage points < 0.5 mV. LVAs were indicated in 8 (53%) among 15 patients, and the average values of the measured LVAs was comparable between the systems (PentaRay map = 5.4 ± 8.7 cm2; Orion map = 4.3 ± 6.4 cm2, p = 0.69). However, in 2 of 8 patients with LVAs, the Orion map indicated LVAs at the septum and posterolateral sites of the LA, respectively, whereas the PentaRay map indicated no LVAs. In those patients, sharp electrograms of > 0.5 mV were properly recorded at the septum and posterolateral sites during appropriate beats in the PentaRay map. The PentaRay map had a shorter procedure time than the Orion map (12 ± 3 min vs. 23 ± 8 min, respectively; p < 0.01). Our study results showed a discrepancy in the LVA evaluation between the PentaRay and Orion maps. In 2 of 15 patients, the Orion map indicated LVAs at the sites where > 0.5-mV electrograms were properly recorded in the PentaRay map.


Assuntos
Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo/fisiologia , Mapeamento Potencial de Superfície Corporal/métodos , Átrios do Coração/fisiopatologia , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia
16.
Heart Rhythm ; 18(2): 189-198, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33007441

RESUMO

BACKGROUND: Perimitral atrial tachycardias (PMATs) are common atrial tachycardias (ATs), yet their mechanisms vary. OBJECTIVE: The purpose of this study was to characterize clinical spontaneous PMATs using an ultra-high-resolution (UHR) mapping system. METHODS: The study included 32 consecutive PMATs in 31 patients who had undergone AT mapping/ablation using a UHR mapping system. RESULTS: Six, 10, 11, and 5 PMATs occurred in cardiac intervention-naïve (group A), post-lateral/posterior mitral isthmus linear ablation (group B), post-atrial fibrillation ablation without mitral isthmus linear ablation (group C), and post-cardiac surgery (group D) patients, respectively. Group A patients tended to be older, more likely were female, and had sinus node or atrioventricular conduction disturbances more frequently. A 12-lead synchronous isoelectric interval was observed in 15 PMATs (46.9%). Coronary sinus activation was proximal to distal or distal to proximal except in 3 PMATs with straight patterns due to epicardial gaps. Left atrial anterior/septal wall (LAASW) low-voltage areas were smallest in group B. Slow conduction areas (SCAs) were identified in 26 PMATs (81.2%) and were located on the LAASW in all group A and group D patients. Conduction velocity in the SCAs was slowest in group B. In group B, all PMATs were terminated by single applications, and the gaps were located epicardially in 5 of 10 (50%). Anterior (n = 23) or lateral/posterior (n = 9) mitral isthmus linear block was successfully created without any complications in all. Twenty-five concomitant ATs among 18 patients (58.1%) also were eliminated. During a median of 20.0 (11.0-40.0) months of follow-up, 28 patients (90.3%) were free from any atrial tachyarrhythmias. CONCLUSION: An UHR mapping-guided approach with identification of the individual tachycardia mechanism should be the preferred strategy given the distinct and complex arrhythmia mechanisms.


Assuntos
Função Atrial/fisiologia , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Frequência Cardíaca/fisiologia , Imageamento Tridimensional/métodos , Taquicardia Supraventricular/cirurgia , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
17.
JACC Clin Electrophysiol ; 6(9): 1067-1072, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32972540

RESUMO

Air embolisms can lead to lethal results; however, few reports have systemically investigated this issue. Of 348 consecutive patients with atrial fibrillation who underwent cryoballoon ablation, procedures were performed conventionally in 251 patients. In the remaining 97 patients, a water bucket was used while inserting the cryoballoon into the sheath. A total of 10 coronary air embolisms with ST-segment elevation in the inferior leads were observed among 9 (2.6%) patients. Multiple air bubbles were identified in 2 patients on emergent coronary angiography. All recovered under conservative treatment without any sequela. The incidence decreased when using the water bucket (1 of 97 [1.03%] vs. 8 of 251 [3.2%], p = 0.454).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Embolia Aérea , Veias Pulmonares , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Embolia Aérea/etiologia , Embolia Aérea/prevenção & controle , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Água
19.
J Cardiovasc Electrophysiol ; 31(5): 1075-1082, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32108407

RESUMO

BACKGROUND: Atrial linear lesions are generally created with radiofrequency energy. We sought to evaluate the feasibility of cryothermal atrial linear ablation. METHODS AND RESULTS: Twenty-one atrial fibrillation (AF) patients underwent linear ablation on the left atrial (LA) roof, mitral isthmus (MI), and cavotricuspid isthmus (CTI) with 8-mm-tip cryocatheters following pulmonary vein isolation. The data were compared with those of 31 patients undergoing linear ablation with irrigated-tip radiofrequency catheters. Conduction block was successfully created in 18 of 20 (90%), 9 of 21 (43%), and 20 of 20 (100%) on the LA roof, MI, and CTI by endocardial cryoablation alone with 19.0 (12.0-24.0), 30.0 (23.0-34.0), and 14.0 (14.0-16.0) minute cryo applications, respectively. The presence of either an interposed circumflex artery or pouch at the MI was significantly associated with failed MI block (P = .04). Conduction block was created in 25 of 31 (83.9%), 27 of 31 (87.1%), and 30 of 31 (96.8%) on the roof, MI, and CTI, respectively, by radiofrequency ablation. During the 17.5 (13.0-31.7) months of follow-up, freedom from AF/atrial tachycardia (AT) was significantly higher in the cryo group (P = .05); especially, recurrent AT was more frequent in the RF group (8/31 vs 1/21; P = .03). Conduction block across the roof, MI, and CTI was durable in 6 of 12 (50.0%), 4 of 12 (33.3%), and 9 of 12 (75.0%) patients during second procedures. All nine patients (except one) with recurrent ATs had at least one roof or MI conduction resumption. CONCLUSIONS: Cryoablation is effective for creating a roof and CTI linear block, however, creating MI block by endocardial ablation alone was often challenging. Conduction resumption of LA linear block is common and recurrent arrhythmias, especially iatrogenic ATs, are more frequently observed after radiofrequency linear ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo
20.
Am Heart J ; 221: 29-38, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31901798

RESUMO

BACKGROUND: In patients with paroxysmal atrial fibrillation (PAF), 10%-15% of patients require repeat procedures after second-generation cryoballoon pulmonary vein isolation (CB-PVI). We sought to explore the mechanisms of recurrences after cryoballoon ablation. METHODS: The data of 122 PAF patients who underwent second procedures for recurrent arrhythmias 7.0 (4.0-12.0) months after the CB-PVI were analyzed. During second procedures, non-PV AF foci were explored with isoproterenol, adenosine, and repetitive cardioversions. RESULTS: In total, 378/487 (77.6%) PVs remained isolated, and reconnections were not observed in any PVs in 59 (48.4%) patients. PV reconnections were associated with recurrences in 38 (31.1%) patients, of whom 33 (86.8%) had reconnections of at least 1 upper PV. In 6 (4.9%) patients, non-PV AF foci were identified in the upper PV antra where cryoballoons cannot isolate but within the circumferential radiofrequency PVI line. Non-PV AF foci were identified in the superior vena cava, right atrial body, left atrial body, and atrial septum in 28 (23.0%), 18 (14.7%), 4 (3.3%), and 5 (4.1%) patients, respectively. Twelve (9.8%) patients had multiple non-PV AF foci. Four (3.3%), 3 (2.4%), and 8 (6.5%) patients underwent second procedures for atrioventricular nodal reentrant tachycardia, atrial flutter, and atrial tachycardias. During 16.0 (8.0-24.0) months of follow-up, freedom from any atrial arrhythmia at 1 year and 2 years after the second procedure was 79.2% and 60.6%. Nineteen (15.5%) patients had antiarrhythmic drug therapy at the last follow-up. CONCLUSIONS: Our study suggested that improvement in the upper PV PVI durability, eliminating arrhythmogenic superior vena cavae and coexisting atrial arrhythmias, and bonus cryoballoon applications at PV antra might improve the single procedure outcome in cryoballoon ablation.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/fisiopatologia , Criocirurgia/métodos , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Taquicardia Supraventricular/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Flutter Atrial/cirurgia , Septo Interatrial/fisiopatologia , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Taquicardia Supraventricular/cirurgia , Veia Cava Superior/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA