Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Endourol ; 35(8): 1223-1228, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33559523

RESUMO

Introduction and Objective: "Clinically insignificant residual fragments" are an independent predictive factor for recurrence of nephrolithiasis. To improve the stone-free rates (SFR), we tested the viability of a novel bioadhesive system for intrarenal embedding and retrieval of residual fragments <1 mm in a kidney model. Materials and Methods: All procedures were performed in a standardized setting, including a kidney model (Kidney module right, Samed GmbH, Dresden) in a plastic basin filled with water. We used a Viper URF flexible ureterorenoscope (fURS) (6.6/8F, Richard Wolf, Knittlingen). A mean amount of 138 mg (standard deviation [SD] ±32.2 mg) of sand grains (range, 0.2-0.8 mm) was inserted in renal calices of the kidney model. We assessed the extraction efficacy of fURS using the bioadhesive system. In total, eight different surgeons performed each one trial, respectively. The endoscopic and macroscopic SFR, the level of the surgeons' experience, and the overall time of stone retrieval were evaluated. Additionally, a survey of the participants was conducted, to assess the contentment with this novel system. Results: The extraction of the sand grains was only possible using the bioadhesive system, otherwise they were too small sized to grab with a retrieval basket. The total SFR was 84% (SD ±11.7%). The operation time (p = 0.052) and the percentage of extracted sand grains (p = 0.194) were not significantly different between experienced and less experienced surgeons. All participants stated that it was a promising technique, which they could imagine using on a daily basis. Conclusions: The bioadhesive system improves the SFR with fragments from 0.2 to 0.8 mm (0% vs 84%). Also, the performance of this operation is not dependent on the surgeon's experience level. This method might improve the SFR in difficult anatomic conditions, that is, lower calices or anomalous kidneys.


Assuntos
Cálculos Renais , Ureteroscopia , Adesivos , Poeira , Humanos , Rim/cirurgia , Cálculos Renais/cirurgia , Resultado do Tratamento
2.
J Endourol ; 31(3): 314-319, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27981854

RESUMO

INTRODUCTION & OBJECTIVES: Transurethral enucleation of the prostate for the management of benign prostatic obstruction (BPO) involves two steps: the enucleation and morcellation procedure. The aim of our study was to assess the efficacy of a morcellator device using disposable and reusable blades with different settings of morcellation speed. METHODS: A prospective randomized study was initiated for patients with symptomatic BPO undergoing Thulium laser enucleation of the prostate. Mechanical tissue morcellation was performed using the Piranha™ morcellator (R. Wolf, Knittlingen, Germany) with disposable or reusable blades at 850 (n = 24) or 1500 revolutions per minute (rpm) (n = 24). Patient characteristics, intraoperative complications, and the morcellation rate (g/min) were recorded. Data are expressed as median and interquartile range (IQR). RESULTS: Forty-eight patients were randomized using disposable (n = 24) or reusable blades (n = 24). For reusable blades, the morcellation rate did not increase when changing the morcellation speed from 850 to 1500 rpm (5 vs 4.53 g/min, p = 0.843). The morcellation rate increased significantly when changing the morcellation speed from 850 to 1500 rpm using single-use blades (4.77 vs 10 g/min, p ≤ 0.014). The morcellation rate was not different at 850 rpm between reusable and single-use blades (5 vs 4.77 g/min, p = 0.671). Conversely, the morcellation rate was significantly different at 1500 rpm between reusable and single-use blades (4.53 vs 10 g/min, p ≤ 0.017). The total morcellation rate (at 850 and 1500 rpm) was significantly increased using single-use blades compared to reusable blades (7.67 vs 4.8 g/min, p ≤ 0.026). Interestingly, enucleated weight (g) and the morcellation rate (g/min) correlated inversely using single-use blades at 1500 rpm (r = -0.742, p ≤ 0.004). Only one superficial bladder injury occurred at 1500 rpm, which needed no further interventions. CONCLUSIONS: The Piranha morcellator facilitates efficient tissue removal with single-use and reusable blades. Disposable morcellator blades increase tissue removal significantly at 1500 rpm.


Assuntos
Equipamentos Descartáveis , Reutilização de Equipamento , Terapia a Laser/métodos , Morcelação/instrumentação , Hiperplasia Prostática/cirurgia , Ressecção Transuretral da Próstata/instrumentação , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA