Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Foot Ankle Surg ; 57(5): 931-937, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30001938

RESUMO

The initial assessment and postoperative monitoring of patients with various abnormalities of the foot in clinical routine practice is primarily based on the analysis of radiographs taken in the weightbearing position. Conventional x-ray imaging, however, only provides a 2-dimensional projection of 3-dimensional (3D) bony structures, and the clinical parameters assessed from these images can be affected by projection biases. In the present work, we addressed this issue by proposing an accurate 3D reconstruction method of the foot in the weightbearing position from low-dose biplanar radiographs with clinical index measurement assessment for clinical routine practice. The accuracy of the proposed reconstruction method was evaluated for both shape and clinical indexes by comparing 3D reconstructions of 6 cadaveric adult feet from computed tomographic images and from biplanar radiographs. For the reproducibility study, 3D reconstructions from the biplanar radiographs of the foot of 6 able-bodied subjects were considered, with 2 observers repeating each measurement of anatomic landmarks 3 times. Baseline assessment of important 3D clinical parameters was performed on 17 subjects (34 feet; mean age 27.7, range 20 to 52 years). The average point to surface distance between the 3D stereoradiographic reconstruction and the computed tomographic scan-based reconstruction was 1 mm (range 0mm to 6mm). The selected radiographic landmarks were highly reproducible (95% confidence interval <2.0 mm). The greatest interindividual variability for the clinical parameters was observed for the twisting angle (mean 87°, range 73° to 100°). Such an approach opens the way for routine 3D quantitative analysis of the foot in the weightbearing position.


Assuntos
Deformidades do Pé/diagnóstico por imagem , Deformidades do Pé/cirurgia , Imageamento Tridimensional , Tomografia Computadorizada por Raios X , Suporte de Carga , Adulto , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
2.
Int Orthop ; 36(8): 1567-73, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22434132

RESUMO

PURPOSE: Acetabular component malalignment in total hip arthroplasty can lead to potential complications such as dislocation, component impingement and excessive wear. Computer-assisted orthopaedic surgery systems generally use the anterior pelvic plane (APP). Our aim was to investigate the reliability of anatomical landmarks accessible during surgery and to define new potential planes of reference. METHODS: Three types of palpations were performed: virtual, on dry bones and on two cadaveric specimens. Four landmarks were selected, the reproducibility of their positioning ranging from 0.9 to 2.3 mm. We then defined five planes and tested them during palpations on two cadaveric specimens. RESULTS: Two planes produced a mean orientation error of 5.0° [standard deviation (SD 3.3°)] and 5.6° (SD 2.7°). CONCLUSIONS: Even if further studies are needed to test the reliability of such planes on a larger scale in vivo during surgery, these results demonstrated the feasibility of defining a new plane of reference as an alternative to the APP.


Assuntos
Acetábulo/anatomia & histologia , Artroplastia de Quadril/métodos , Articulação do Quadril/anatomia & histologia , Cirurgia Assistida por Computador/métodos , Acetábulo/cirurgia , Mau Alinhamento Ósseo/prevenção & controle , Cadáver , Feminino , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Masculino , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA