Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 60(3): 662-668, 2021 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-33956958

RESUMO

OBJECTIVES: Our goal was to evaluate results of endovascular aortic arch repair using the Relay Branch system. METHODS: Forty-three patients with thoracic aortic pathology involving the aortic arch have been treated with the Relay Branch system (Terumo Aortic, Sunrise, FL, USA) in 10 centres. We assessed in-hospital mortality, neurological injury, treatment success according to current reporting standards and the need for secondary interventions. In addition, outcome was analysed according to the underlying pathology: non-dissective disease versus residual aortic dissection (RAD) (defined as remaining dissection after previous type A repair, chronic type B aortic dissections). RESULTS: In-hospital mortality was 9% (0% in patients with RAD). Disabling stroke occurred in 7% (0% in patients with RAD); non-disabling stroke occurred in 19% (7% in patients with RAD). Early type IA and B endoleak formation occurred in 4%. Median follow-up was 16 ± 18 months. During the follow-up period, 23% of the patients died. Aortic-related deaths were low (3% in patients with RAD). CONCLUSIONS: The results of endovascular aortic arch repair using the Relay Branch system in a selected patient population with regard to technical success are good. In-hospital mortality is acceptable, the number of disabling strokes is low and technical success is high. Non-disabling stroke is a major concern, and every effort has to be taken to reduce this to a minimum. The best outcome is seen in patients with underlying RAD. Finally, more data are needed.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Stents , Resultado do Tratamento
2.
Eur J Cardiothorac Surg ; 53(5): 1007-1012, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29351610

RESUMO

OBJECTIVES: Our goal was to assess the results after orthotopic branched endovascular aortic arch repair using a new double-branch endoprosthesis in patients with thoracic aortic disease affecting the aortic arch who cannot undergo classical surgery. METHODS: Within a 4-year period, 15 patients with thoracic aortic disease affecting the aortic arch were treated with the Bolton Relay plus double-branch endoprosthesis (Bolton Medical, Sunrise, FL, USA). We assessed clinical outcome, occurrence of endoleaks and the need for secondary interventions. The median logistic EuroSCORE I level was 13.6 (4.2; 22.8). RESULTS: The in-hospital mortality rate was 6.7%. A disabling stroke was observed in 1 (6.7%) patient, whereas non-disabling strokes occurred in 2 (13.3%) patients. Type I and III endoleaks occurred in 6.7%. The median follow-up period was 263 (1st quartile 84; 2nd quartile 564) days. Four patients died during the follow-up period. Aortic-related survival was 100%. CONCLUSIONS: Orthotopic branched endovascular aortic arch repair using the Bolton Relay Plus double-branch endoprosthesis is a safe and feasible technique enriching the armamentarium to treat patients with thoracic aortic disease who cannot undergo classical surgery. Aortic-related survival is excellent, and the occurrence of disabling stroke and endoleaks warranting treatment is low. Further studies are needed to assess the long-term durability of this new method.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Estudos de Coortes , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Resultado do Tratamento
3.
J Vasc Surg ; 58(2): 478-81, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23402874

RESUMO

Suprarenal pathologies can be treated with immediately available devices with the chimney technique, which offers a bail-out in patients not eligible for a branched or fenestrated stent graft. We present an adjusted chimney technique for total renal and visceral revascularization in a patient with a suprarenal aneurysm. Although short-term results look promising, longer follow-up is anticipated.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Artéria Renal/cirurgia , Idoso , Aneurisma Aórtico/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Humanos , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA